ARCHITECT S SUPPLEMENTAL INSTRUCTIONS

Similar documents
View Point Terrace Apartments SECTION DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY

DESIGN!!GUIDELINES!!!!!

B) The University shall check the installation of finish hardware at the completion of the Project.

Design Guidelines and Standards Manual University of Cincinnati

FINISH HARDWARE

DIVISION 8 OPENINGS SECTION DOOR HARDWARE

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION

22 Series. Exit device

SECTION FINISH HARDWARE

Qty Description Catalog Number Finish Mfr 6 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE 2 EA SURFACE BOLT SB360 12" T 604 IVE 1 EA STOREROOM

5000 & F5000 Rim Type Panic And Fire Exit Devices 5000V & F5000V Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 2

A. Hardware for new doors. B. Keying of new hardware into existing hardware keying system.

Adams rite. Exit Devices & parts exit devices series exit device parts

98/99 Series Exit Devices

SERIES 700 TECHNICAL DETAILS MONDAY, JANUARY 21, 2008

9827/9927 Surface mounted vertical rod device. 9827/9927 Surface mounted vertical rod device. Specifications Device functions

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

W Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

33A/35A Series Exit Devices

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

Light/Medium-Duty Knob Locksets. CK4700 Series

CL3500 Series. Heavy-Duty Cylindrical Lever Lockset

SERIES 500 TECHNICAL DETAILS THURSDAY, JANUARY 24, 2008

JUNE 9, 2017 SECTION SECTION DOOR HARDWARE

3400 Series

Continuous Hinges Hager McKinney Markar

626 FAL REQUIRED 1 EA STOREROOM LOCK T581 Q X IC - F2 MECH & 626 FAL

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

CAL-ROYAL & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156.

October 2014 Page 1 of 12

UC DAVIS Campus Standards & Design Guide DIVISION 08 OPENINGS

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

Optional Latchbolts /8" (60 mm) Square or Round Corner, Dead Latch /4" (70 mm) Square or Round Corner, Dead Latch - Standard

MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks

T H E F A L C O N D I F F E R E N C E

K Series. Grade 1 cylindrical lever locks

Locksets. Requirements. Approved Manufacturers. Schlage D Series Rho Trim No Substitution Cylinders Medeco No Substitution

DIAMOND DOOR PRODUCTS TECHNICAL DETAILS MARCH 2010

.1 Append the Hardware Schedule attached to this addendum to the end of the Section.

5/8" Radius Corner Hinges

33A/35ATM. Series. Exit Devices

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES DOORS AND OPENINGS - DIVISION 08 Hardware

HARDWARE SCHEDULE PROJECT XYZ

33A/35A Series. Exit devices

X Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series

Table of Contents 20 Series Exit Device

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

3800 Series

CK4400 Series. Standard Duty Cylindrical Knob Locksets

F A L C O N T S E R I E S F E A T U R E S

Recessed. Touch bar exit devices

22 Series. Exit device

W Series Cylindrical Lever. W Series cylindrical lever lock

Dor-O-Matic Exit Devices

ABS-AMERICAN BUILDING SUPPLY, INC. Von Duprin

EXTRUDED ALUMINUM BALANCED DOORS AND ENTRANCES

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

GRADE 2 HEAVY & STANDARD DUTY CYLINDRICAL LOCKS

22 Series. Exit device

S U B M I T T A L T R A N S M I T A L

E-Plex 5700 Series E-PLEX

33A/35A Series. Exit devices

7 LINE CYLINDRICAL LEVER LOCK

20 Series. Exit Device

33A/35A Series. Exit devices

7KC SERIES: MEDIUM DUTY CYLINDRICAL LOCKS LEVERS. 7KC Series. Medium Duty Cylindrical Locks Levers. BEST: Setting the Standard for Security

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview

98/99 Series. Exit devices

Auxiliary Locks. Deadlocks and Deadbolts. Falcon Monarch Dor-O-Matic

Simplex. Cylindrical Knob Series. Grade 1 Extra Heavy Duty Cylindrical Knob

Entry. Entry. Entry. Entry

351 Series Door Closers Models: Finishes: BHMA BHMA Description

S200-SERIES. Interconnected Entrance Locks

CL3200 Series. Security Bolt Lever Lockset

Non-handed, pre-assembled for left hand door installation easily changed in the field

98/99 Series. Exit devices

9849/9949 Concealed Vertical Cable Device

350/500 Heavy Wall TM Entrances 1

Cylinders & Key Blanks

BULLDOG. Commercial Hardware

22 Series. Exit device

Table Of Contents. 30 Series Exit Device. On The Cover

Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800

Retrofit Locks and Trim. Product Catalog

DC3000 Series. Door Closers

ARCHITECTURAL DOOR HARDWARE EXIT DEVICE CATALOG

GRADE 1 HEAVY DUTY CYLINDRICAL LOCKS

a. Classroom function, Guardbolt deadlocks latchbolt b. Latchbolt retracted by either trim unless outside trim is locked by key

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device

FEATURES & SPECIFICATIONS. 100% internal parts quality inspection provides security, reliability and durability

Electronic Standalone Pushbutton Locking

22 Series Exit Devices

ED5000 Series. Pushpad Exit Devices

98/99 Series. Exit devices

HARDWARE SCHEDULE SHELDON CHILD CEVELOPMENT CENTER TOPEKA PUBLIC SCHOOLS PART OF ADDENDUM NO. 2 ITEM NO

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

E-Plex 5700 Series E-PLEX

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS:

268, 269 & 278. Concealed Door Closers

Transcription:

ARCHITECT S SUPPLEMENTAL INSTRUCTIONS This document is based on AIA DOCUMENT G710 OWNER ARCHITECT CONSULTANT CONTRACTOR FIELD OTHER PROJECT: 3939 SW View Point Terrace Portland, OR 97239 ARCHITECT S SUPPLEMENTAL INSTRUCTION NO. 038 OWNER: VPT llc DATE OF ISSUANCE: CONTRACTOR: Pavilion Construction 4700 SW Macadam Ave Portland, OR 97239 ARCHITECT: COLAB Architecture + Urban Design llc 421 SW 6th Ave, Suite 1250 Portland, OR 97204 503.827.5339 CONTRACT FOR: CONTRACT DATED: General Construction ARCHITECT S PROJECT NO.: 1309 09/30/2014 The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time. DESCRIPTION: (Provide all material and labor to perform the following) Door hardware clarification @ main entry door 101 ATTACHMENTS: Item: Pages: Date: Viewpoint Terrace Project Manual section 08 71 00 14 ISSUED BY: ARCHITECT: Jessica Molinar COLAB Architecture + Urban Design llc

SECTION 087100 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. Work under this section includes the complete finish hardware requirements for the project. Quantities listed are for the contractor s convenience only and are not guaranteed. Items not specifically mentioned, but necessary to complete the work shall be furnished, matching the items specified in quality and finish. B. Related Sections: 1. Section 08110 Metal Doors and Frames 2. Section 08210 Wood Doors and Frames 3. Section 08410 Aluminum Doors and Frames 1.2 QUALITY ASSURANCE A. Product Qualification: 1. To assure a uniform high quality of materials for the project, it is intended that only specified items be furnished. Comparable products may be accepted upon prior approval of architect. 2. Hardware to be new, free of defects, blemishes and excessive play. Obtain each kind of hardware (Mechanical latch and locksets, exit devices, hinges and closers) from one manufacturer except where specified. 3. Fire-Rated opening in compliance with NFPA80. Hardware UL10C/UBC-7-2 (positive pressure) compliant for given type/size opening and degree of label. Provide proper latching hardware, non-flaming door closers, approved bearing hinges and smoke seal. Furnish openings complete. B. Supplier Qualifications: 1. Hardware supplier will be a direct factory contract supplier who employs a certified Architectural Hardware Consultant (AHC) available at all reasonable times during the course of the work for project hardware consultation to owner, architect and contractor. 2. Supplier will be responsible for detailing, scheduling and ordering of finish hardware. 3. Conduct pre-installation conference at jobsite. Initiate and conduct with supplier, installer and related trades. Coordinate materials and techniques and sequence complex hardware items and systems installation. 4. Key Conference shall be initiated and conducted with owner to determine system, keyway(s) and structure. C. Installer Qualifications: 1. Installer to have not less than 3 years experience specializing in installation of work in this section. Company must maintain qualified personnel trained and experienced in installing hardware. DOOR HARDWARE 087100-1

1.3 REFERENCES A. NFPA80 Fire Doors and Windows B. NFPA101 Life Safety Code C. NFPA105 Smoke and Draft Control Door Assemblies D. ANSI A117.1 Specifications for making Buildings usable by physically handicapped people. 1.4 SUBMITTALS A. Hardware schedule: Submit digitally or six copies of schedule. Organize vertically formatted schedule into Hardware Sets with index of doors and headings, indication complete designations of every item required for each door or opening. Include the following: 1. Type, style, function, size, quantity and finish of hardware items. 2. Name, part number and manufacture of each item. 3. Fastenings and other pertinent information. 4. Explanation of abbreviations, symbols and codes contained in schedule. 5. Door and frame sizes, materials and degrees of swing. B. Product Data: Submit four copies for each product indicated. C. Templates: Obtain and distribute templates for doors, frames, and other works specified to be prepared for installing door hardware. D. Wiring/Riser diagrams: As required for electric hardware indicated. E. Maintenance Data: For each type of door hardware to include in maintenance manuals specified in Division 1. F. Keying Schedule: Prepared by or under the supervision of supplier, after receipt of the approved finish hardware schedule, detailing Owner s final keying instructions for locks. G. Samples: Upon request submit material samples. 1.5 DELIVERY, STORAGE, AND HANDLING A. Deliver, store, handle and protect products to project site under provisions of Division 1 and as specified herein. B. Tag each item or package separately, with identification related to the final Door Hardware Schedule, and include basic installation instructions with each item or package. C. Deliver keys to Owner by registered mail. 1.6 WARRANTY A. The finish hardware shall have a limited warranty against defects in workmanship and operation for a period of one year from date of substantial completions and the following items are as shown: DOOR HARDWARE 087100-2

1. Closers: Ten Years 2. Exit Devices: Ten Years 3. Locksets: Ten years PART 2 - PRODUCTS 2.1 MATERIAL AND FABRICATION A. Provide all door hardware for complete work, in accordance with the drawings and as specified herein. B. Provide items and quantities not specifically mentioned to ensure a proper and complete operational installation. 2.2 MANUFACTURERS A. Approval of products from manufacturers indicated as Acceptable Manufacturer is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer s product. ITEM SCHEDULED MANUFACTURER ACCEPTABLE MANUFACTURER Hinges Ives (IVE) Hager, McKinney, Flush Bolts & Coordinators Ives (IVE) Burns, Rockwood Locksets & Deadlocks Falcon (FAL) Best, Sargent Exit Devices & Mullions Falcon (FAL) Precision, Sargent Electric Strikes Von Duprin (VON) HES, Folger Adam Cylinders & Keying Schlage (SCH) Best, Corbin-Russwin Door Closers Falcon (FAL) Corbin/Russwin, Sargent Door Trim Ives (IVE) Burns, Rockwood Protection Plates Ives (IVE) Burns, Rockwood Overhead Stops Glynn-Johnson (GLY) Rixson, Sargent Thresholds & Weatherstrip National Guard Products (NGP) Pemko, Zero 2.3 HANGING A. Conventional Hinges: Hinge open width minimum, but of sufficient throw to permit maximum door swing. Steel or stainless steel pins: 1. Three hinges per leaf to 7 feet, 6-inch height. Add one for each additional 30 inches in height or any fraction thereof. 2. Provide 4 ½ x 4 ½ for 1 3/4 thick doors up to 36. Provide 5 x 4 ½ on doors over 36. 3. Provide 4 x 4 for 1 3/8 thick doors. 4. Exterior outswing doors to have non removable (NRP) pins. 5. Pin tips, flat button, finish to match leaves 6. Interior doors over 36 Heavy weight 7. Interior doors up to 36 Standard weight DOOR HARDWARE 087100-3

2.4 LOCKSETS, LATCHSETS, DEADBOLTS A. Extra Heavy Duty Cylindrical Locks: Falcon T Series 1. Provide cylindrical locks conforming to ANSI A156.2 Series 4000, Grade 1. Cylinders: Refer to KEYING article, herein. 2. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with a 1/2 inch (13 mm) latch throw. Provide proper latch throw for UL listing at pairs. 3. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws. 4. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag. 5. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim. 6. Lever Trim: Solid cast levers without plastic inserts, and wrought roses on both sides. a. Lever Design: Falcon Quantum. B. Cylindrical Locks: Falcon W Series 1. Provide cylindrical locks conforming to ANSI A156.2 Series 4000, Grade 2. Cylinders: Refer to KEYING article, herein. 2. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with 1/2 inch (13 mm) latch throw. Provide 2-3/8 inches (60 mm) backset where noted of if door or frame detail requires. Provide proper latch throw for UL listing at pairs. 3. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws. Provide levers that operate independently, and have internal return springs to prevent lever sag. 4. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim. 5. Lever Trim: Solid cast levers without plastic inserts, and wrought roses on both sides. a. Lever Design: Falcon Quantum C. Tubular Locks: Schlage F Series 1. Provide tubular locks conforming to ANSI A156.2 Series 4000, Grade 2. Cylinders: Refer to KEYING article, herein. 2. Provide locks with standard 2-3/8 inches (60 mm) adjustable to 2-3/4 inches (70 mm) backset with 1/2 inch (13 mm) latch throw. Provide 2 ¾ inches (70 mm) backset, unless 2-3/8 inches (60 mm) is required by door or frame detail, or noted otherwise. 3. Provide locksets that fit standard 2-1/8 inches (54 mm) diameter bore without use of thrubolts. 4. Standard Rose Size: 2-1/2 inches (64 mm) in diameter. 5. Door Thickness: Locksets adjustable to fit in 1-3/8 inches (35 mm) or 1-3/4 inches (44 mm) door thickness. 6. Provide standard T-strikes unless extended lip strikes are necessary to protect trim. 7. Lever Trim: Solid cast levers without plastic inserts, and wrought roses on both sides. a. Lever Design: Schlage Jazz D. Interconnected Locks: Schlage CS210 Series 1. Provide interlocked locksets conforming to ANSI A156.12 Series 5000, Grade 2 with simultaneous retraction of deadbolt and latch for single motion egress. Cylinders: Refer to KEYING article, herein. 2. Provide locks with 2-3/4 inches backset, based on door detail, with 1/2 inch latch throw latchbolt and 1 inch throw deadbolt. 3. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag. DOOR HARDWARE 087100-4

4. Provide manufacturers standard T-strike, unless extended lip strike is necessary to protect trim, and deadbolt strike. a. Lever Design: Schlage Neptune 2.5 EXIT DEVICES A. Rated and Non-Rated Exit Devices: Falcon 24/25 Series 1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1, and UL listed for Panic Exit or Fire Exit Hardware. Cylinders: Refer to KEYING article, herein. 2. Exit Devices: Touchpad type, fabricated of brass, bronze, stainless steel, or aluminum, plated to standard architectural finishes to match balance of door hardware. 3. Touchpad: Extend minimum of one half of door width. Match exit device finish or provide compatible finish. Provide compression springs in devices, latches, and outside trims or controls, tension springs also acceptable. 4. Provide devices with deadlatching feature for security and for future addition of alarm kits and other electrical requirements. 5. Provide manufacturer's standard strikes. 6. Provide exit devices cut to door width and height. Locate exit devices at height recommended by exit device manufacturer, allowable by governing building codes, and approved by Architect. 7. Mount mechanism case flush on face of doors, or provide spacers to fill gaps behind devices. Where glass trim or molding projects off face of door, provide glass bead kits. 8. Provide hex key dogging at non-fire-rated exit devices. 9. Where lever handles are specified as outside trim for exit devices, provide heavy-duty lever trims with forged or cast escutcheon plates. Provide vandal-resistant levers that will travel to 90-degree down position when more than 35 pounds of torque are applied, and which can easily be re-set. a. Lever Style: Match lever style of locksets. 10. Provide UL labeled fire exit hardware for fire rated openings. 2.6 KEYS, KEYING, AND KEY CONTROL A. See Keying Requirements in this section 2.7 CLOSERS A. Heavy Duty Surface Closers: Falcon SC70 Series 1. Provide door closers certified to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. ISO 9000 certify closers. Stamp units with date of manufacture code. 2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder. 3. Closer Body: 1-1/2 inch (38 mm) diameter with 11/16 inch (17 mm) diameter heat-treated pinion journal. 4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F. 5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards. DOOR HARDWARE 087100-5

6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck. 7. Pressure Relief Valve (PRV) Technology: Not permitted. 8. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting. B. Medium Duty Surface Closers: Falcon SC80 Series 1. Provide door closers certified to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. 2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder. 3. Closer Body: 1-1/4 inch (32 mm) diameter, with 5/8 inch (16 mm) diameter pinion journal. 4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F. 5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards. 6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck. 7. Pressure Relief Valve (PRV) Technology: not permitted. 8. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting. C. Light Duty Surface Closers: Falcon SC60 Series 1. Provide door closers certified to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. 2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder. 3. Closer Body: 1-1/8 inch (29 mm) diameter with 5/8 inch (16 mm) diameter pinion journal. 4. Hydraulic Fluid: Fireproof, passing requirements of UL10C. 5. Pressure Relief Valve (PRV) Technology: Not permitted. 6. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting. 2.8 OTHER HARDWARE A. Door stops: Provide stops to protect walls, casework or other hardware. 1. Except as otherwise indicated, provide stops (wall, floor or overhead) at each leaf of every swinging door leaf. 2. Where wall or floor stops are not appropriate, provide overhead holders. B. Weatherstrip and Gasket 1. Provide continuous weather-strip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated or scheduled. 2. Provide non-corrosive fasteners as recommended by the manufacturer for application indicated. C. Thresholds DOOR HARDWARE 087100-6

1. Except as otherwise indicated, provide standard metal threshold unit of type, size and profile as detailed or scheduled. D. Silencers 1. Interior hollow metal frames, 3 for single doors, 2 for pairs of doors. E. Kickplates 1. Four beveled edges,.050 inches minimum thickness, height and width as scheduled. Sheet-metal screws of bronze or stainless steel to match other hardware. 2.9 HARDWARE FINISH A. Provide the following finishes unless noted differently in hardware groups: Hinges Locksets Exit Devices Closers Kickplates Other Hardware Thresholds Weatherstrip/Sweeps 630 Stainless Steel Exterior, 262 Dull Chrome Interior 626 Dull Chrome 626 Dull Chrome 689 Aluminum 630 Stainless Steel 626 Dull Chrome Aluminum Aluminum 2.10 KEYING REQUIREMENTS A. All keyed cylinders shall be subject to a new Schlage Masterkey system. B. Furnish cylinders with construction cores. Following construction supply permanent keyed cores. C. Cylinders to be furnished with visual key control with key code. Stamped on the face of the keys and marked on the back or side of the cylinders. D. Key Quantities 6 EA Master Keys 4 EA Control Keys 2 EA Construction Control Keys 10 EA Construction Keys 3 EA Change Keys per keyed alike group PART 3 - EXECUTION 3.1 ACCEPTABLE INSTALLERS: A. Factory trained, certified, and carries a factory-issued card certifying that person as a Certified Installer. Alternative: can demonstrate suitably equivalent competence and experience. DOOR HARDWARE 087100-7

3.2 PREPARATION A. Ensure that walls and frames are square and plumb before hardware installation. B. Locate hardware per SDI-100 and applicable building, fire, life-safety, accessibility, and security codes. Notify Architect of any code conflicts before ordering materials. 3.3 INSTALLATION A. Do not install surface mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate for proper installation and operation. B. Locate floor stops not more than 4 inches from the wall. C. Drill pilot holes for fasteners in wood doors and/or frames. 3.4 ADJUSTING A. Adjust and check for proper operation and function. Replace units, which cannot be adjusted to operate freely and smoothly. B. Hardware damaged by improper installation or adjustment methods to be repaired or replaced to Owner s satisfaction. 3.5 FOLLOW UP INSPECTION A. Installer to provide letter of agreement to Owner that approximately 6 months after substantial completion, installer will visit project with representative of the manufacturers of the locking devices and door closers to accomplish the following: 1. Re-adjust locks and closers 2. Evaluate maintenance procedures and recommend changes or additions, and instruct Owner s personnel. 3. Identify items that have deteriorated or failed. 4. Submit written report identifying problems and likely future problems. 3.6 DEMONSTRATION A. Demonstrate electrical, electronic and pneumatic hardware system including adjustment and maintenance procedures 3.7 PROTECTION/CLEANING A. Cover installed hardware, protect from paint, cleaning agents, weathering, carts/barrows, etc. Remove covering materials and clean hardware just prior to substantial completion. Clean adjacent wall, frame and door surfaces soiled from installation/reinstallation process. DOOR HARDWARE 087100-8

3.8 DOOR HARDWARE GROUPS HW SET: 01 1 EA PANIC HARDWARE 22-NL-OP-110MD 689 VON 1 EA RIM CYLINDER 20-057-ICX 1 EA PERMANENT CORE 23-030 BALANCE OF HARDWARE BY GATE MANUFACTURER FABRICATE GATE TO ACCOMMODATE PROPER INSTALLATION OF PANIC DEVICE. FIELD DRILL WEEP HOLES FOR PANIC DEVICE PUSH PAD. HW SET: 02 1 EA K-I-L CYLINDER 21-020 HARDWARE BY DOOR / FRAME MANUFACTURER VERIFY CYLINDER REQUIREMENTS WITH DOOR/FRAME MANUFACTURER HW SET: 03 3 EA HINGE 5BB1 5 X 4.5 NRP 630 IVE 1 EA STOREROOM LOCK T581P QUA 626 FAL KEYED ALIKE FOR CONSTRUCTION 1 EA PERMANENT CYL FOR 24-031 FALCON T LOCK 1 EA SURFACE CLOSER SC71 HDPA 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP 1 EA DOOR SWEEP C627A CL NGP 1 EA THRESHOLD 659 MS/LA AL NGP HW SET: 04 DOOR HARDWARE 087100-9

2 EA PIVOT SET 7226F SET 630 IVE 2 EA INTERMEDIATE PIVOT 7226F INT 630 IVE 1 EA POWER TRANSFER EPT10 689 FAL 1 EA PANIC HARDWARE 24-C-EO 626 FAL 1 EA ELEC PANIC EL-24-C-C-718 626 FAL HARDWARE 1 EA RIM CYLINDER 20-057-ICX 1 EA PERMANENT CORE 23-030 2 EA 90 DEG OFFSET PULL 8190HD 10" O 630 IVE 2 EA OVERHEAD STOP 100S ADJ 630 GLY 2 EA SURFACE CLOSER SC71 HDPA 689 FAL 2 EA TOP RAIL DROP PLATE SC70-18PA 689 FAL 2 EA BLADE STOP SPACER SC70-61 689 FAL 1 EA POWER SUPPLY PS914 900-2RS LGR FAL ACCESS CONTROL - WORK OF DIVISION 28 CARD READER - WORK OF DIVISION 28 PERIMETER SEALS BY DOOR SUPPLIER OPERATIONAL DESCRIPTION VALID CREDENTIAL WILL MOMENTARILY RETRACT LATCHBOLT OF RHR LEAF, DOOR CAN BE OPENED FROM OUTSIDE. ALWAYS FREE EGRESS. HW SET: 05 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK W581P QUA 626 FAL KEYED ALIKE FOR CONSTRUCTION 1 EA K-I-L CYLINDER 21-020 1 EA OH STOP 90S 630 GLY 1 EA SURFACE CLOSER SC81 REG FC 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP HW SET: 06 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA FIRE EXIT HARDWARE F-25-R-L-BE-510-QUA 630 FAL 1 EA SURFACE CLOSER SC71 SS 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP DOOR HARDWARE 087100-10

HW SET: 07 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PASSAGE SET W101S QUA 626 FAL 1 EA SURFACE CLOSER SC81 REG FC 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP HW SET: 08 1 EA POWER TRANSFER EPT10 689 FAL 1 EA DELAYED PANIC CX-98-L-BE-17 626 VON HARDWARE 1 EA MORTISE CYLINDER 20-061-ICX 1 EA PERMANENT CORE 23-030 1 EA SURFACE CLOSER SC71 REG 689 FAL 1 EA WALL STOP WS406/407CCV 630 IVE 1 EA DOOR CONTACT 679-05HM BLK SCE 1 EA POWER SUPPLY PS914 LGR FAL ACCESS CONTROL - WORK OF DIVISION 28 BALANCE OF HARDWARE BY DOOR SUPPLIER 2 EA CARD READER - WORK OF DIVISION 28 PERIMETER SEALS BY DOOR SUPPLIER OPERATIONAL DESCRIPTION DELAYED EGRESS SYSTEM: DEPRESSING PUSHBAR OF PANIC DEVICE BEGINS 15 SECOND IRREVERSIBLE ALARM CYCLE. UPON COMPLETION OF ALARM CYCLE FREE EGRESS IS ALLOWED. LEVER TRIM NORMALLY LOCKED. DEVICE CAN BE ARMED, RESET OR DISARMED BY KEY OR ACCESS CONTROL. PRESENTATION OF VALID CARD WILL TEMPORARILY SHUNT ALARM AND ALLOW ACCESS FROM PUSH AND PULL SIDES OF DOOR. DOOR WILL UNLOCK UPON POWER LOSS, SIGNAL FROM SPRINKLER OR FIRE DETECTION SYSTEM, OR BY SIGNAL FROM THE FIRE COMMAND CENTER. HW SET: 09 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK W581P QUA 626 FAL KEYED ALIKE FOR CONSTRUCTION 1 EA K-I-L CYLINDER 21-020 1 EA SURFACE CLOSER SC81 REG FC 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE DOOR HARDWARE 087100-11

1 EA WALL STOP WS406/407CCV 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP HW SET: 10 1 EA MORTISE CYLINDER 20-013 114 BALANCE OF HARDWARE BY DOOR SUPPLIER VERIFY CYLINDER REQUIREMENTS WITH DOOR/FRAME MANUFACTURER HW SET: 11 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ENTRANCE LOCK CS210TD NEP PLY 1 EA PERMANENT CORE 23-030 1 EA SURFACE CLOSER SC61 REG SLIM 689 FAL 1 EA KICK PLATE 8400 6" X 2" LDW B4E 630 IVE 1 EA BASE SPRING STOP 061 652 IVE USE IVES 70 HINGE PIN STOP WHERE WALL IS NOT AVAILABLE 1 EA DOOR VIEWER U698 626 IVE PERIMETER SEALS BY DOOR SUPPLIER NOTE: TRANSITION STRIP PROVIDED BY OTHERS. COORDINATE DOOR UNDERCUT WITH DOOR SHOE, FLOORING, AND TRANSITION STRIP. HW SET: 12 3 EA HINGE ***5PB1 RC1 4 X 4 652 IVE 1 EA PASSAGE SET F10 JAZ 1 EA BASE SPRING STOP 061 652 IVE USE IVES 70 HINGE PIN STOP WHERE WALL IS NOT AVAILABLE 3 EA SILENCER SR65 GRY IVE ***PROVIDE 4 ½ X 4 ½ HINGE AT 1 ¾ THICK DOORS HW SET: 13 DOOR HARDWARE 087100-12

3 EA HINGE ***5PB1 RC1 4 X 4 652 IVE 1 EA PRIVACY LOCK F40 JAZ 1 EA BASE SPRING STOP 061 652 IVE USE IVES 70 HINGE PIN STOP WHERE WALL IS NOT AVAILABLE 3 EA SILENCER SR65 GRY IVE ***PROVIDE 4 ½ X 4 ½ HINGE AT 1 ¾ THICK DOORS HW SET: 14 1 EA MULTIPLE BYPASS 111MD JOH PACK 3 EA FLUSH PULL 221 626 IVE HW SET: 15 1 EA POCKET DOOR 1500 JOH ASSEMBLY 1 EA FLUSH PULL 221 626 IVE 1 EA DOOR EDGE PULL 230 626 IVE HW SET: 16 6 EA HINGE ***5PB1 RC1 4 X 4 652 IVE 2 EA ROLLER LATCH RL30A 626 IVE 2 EA SINGLE DUMMY TRIM F170 JAZ 619 SCH 2 EA BASE SPRING STOP 061 USE IVES 70 HINGE PIN STOP WHERE WALL IS NOT AVAILABLE 652 IVE ***PROVIDE 4 ½ X 4 ½ HINGE AT 1 ¾ THICK DOORS HW SET: 17 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK W581P QUA 626 FAL KEYED ALIKE FOR CONSTRUCTION 1 EA K-I-L CYLINDER 21-020 1 EA SURFACE CLOSER SC81 HDPA FC 689 FAL DOOR HARDWARE 087100-13

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 SET SEALS 5050B (HEAD & JAMBS) BRN NGP End of Section DOOR HARDWARE 087100-14