Sturdy Truck Body Poultry Shipping Truck - Operations Manual August 2003

Similar documents
Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Combined Ventilation Controller RVWS-T-224HA

CHAPTER 10 ELECTRIC SYSTEM

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Technical Information and Diagnostic Guide

Third Generation NITE Phoenix

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

Module 4: Climate Control

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

VAL6 KBE5S. Service Manual

SECTION A Engine Cooling

Service Manual for Battery Control Center

3.10 Air Conditioning (A/C) Contents

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

Deicer Operating Instructions Table of Contents

TC Series Cooling Systems

Jeep Wrangler TJ 4.0 LITER Installation instructions

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

A/C-HEATER SYSTEM - AUTOMATIC

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Xebra Electrical Component Locations

Temperature Controller OVATION 214 User's Guide

8. Remote Control Panel P4 Control

DESCRIPTION AND OPERATION

FULL AUTO TEMPERATURE CONTROL GENERAL 1. SPECIFICATIONS FULL AUTO TEMPERTURE CONTROL REXTON

Rev: Flow Max 115V AC Fluid Pump

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

2006 MINI Cooper GENINFO Maintenance - Overview - MINI

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Battery Control Center - Diesel

Electrical Systems - Machine Electrical System. Electrical System Components Diagram Electrical System Components

ECONOMIZERS. 5/2012 Supersedes

6 Litre Oil-Less Air Compressor

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Diesel Cooker X 100. Installation Instructions

3.5 Air Conditioning (A/C) Contents

AIR CONDITIONER SECTION AC CONTENTS AUTO

A/C-HEATER SYSTEM - AUTOMATIC


Antifreeze Type SYC1025 (Long life coolant) Mixing ratio (water:antifreeze) Cooling fan module Type Electric Capacity

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

An ISO 9001:2008 Registered Company

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Maintenance of Pleasureboat Diesel Engine GM Series

ENGINE COOLING SECTION GENERAL DESCRIPTION / 1 ENGINE COOLING. Figure 1 - Cooling System Flow

Climate Control System

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

Section 3 Technical Information

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

ARTICLE BEGINNING * PLEASE READ THIS FIRST * DESCRIPTION OPERATION ATC COMPUTER BLEND-AIR DOOR ACTUATOR CONTROL PANEL

Mitsubishi EVO VII-IX Intercooler Waterspray System

ELECTRIC VEHICLE DISMANTLING MANUAL

13A-1 FUEL CONTENTS MULTIPOINT FUEL INJECTION (MPI) FUEL SUPPLY... 13B

an ISO 9001:2008 Registered Company 1964 CHEVY IMPALA WITHOUT FACTORY AIR REV C 7/8/14, 1964 IMPALA wo AC EVAP INST PG 1 OF 25

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

CHAPTER 10 STEAM CATAPULTS General

Engine Cooling. Cooling System Component Layout.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

12 amp RMS Battery Charger

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

CX-SERIES ADVANCED BATTERY CHARGER

Safety & Installation Instructions

Subject Underhood G System Error Codes and Symptoms System or Parts affected

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Idle Free Systems, Inc. Reference Guide System Component Information

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

HOW - TO EMISSION CONTROL BASICS EMISSION CONTROL BASICS

Part 1 OPERATION OF INSTRUMENTS AND CONTROLS

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

CHEM-TEX POWER MAX 25 GOLD EDITION TRUCK MOUNT MANUAL

1994 ENGINE PERFORMANCE TOYOTA SYSTEM & COMPONENT TESTING

Technical FAQs Technical and Basic Pool Information

Direct Gas-Fired Heating

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

HVAC System: Engine Cooling, Controls and Communication

1. SPECIFICATIONS 01-2

R & D SPECIALTIES ROTROL I USER'S MANUAL

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

COOLING SYSTEM. Return to Main Table of Contents

AHE S - 12 VDC AHE X - 12 VDC AHE X - 12 VDC

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

WILDFIRE OPERATOR TRAINING MANUAL

Tecomotive - tinycwa - User Manual Intercooler Version

DAVIES, CRAIG PROPRIETARY LIMITED A.B.N A.C.N MELBOURNE AUSTRALIA

Accessories. Series REC

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

Transcription:

1.0 Introduction The Sturdy ventilation controller is designed to automatically control indoor air quality including: temperature, relative humidity, carbon dioxide and oxygen in the interior of the vehicle under various exterior and interior conditions. The primary purpose of the system is for the control of indoor air quality while shipping live poultry. This manual outlines the control system and general procedures to follow during operation. 2.0 General Operation Control Modes and Overrides The control has two modes of operation: AUTO and MANUAL. Selection Between modes is done on the Dash Panel (see photo below). Mode Selection Switch Control Dash Panel Auto Control The control should be operated in the auto mode during normal operation between the time when the truck is loaded until unloading. During auto control, the user has no direct control over any of the components of the ventilation system. The user should only have to monitor the sensor feedback on the visual Sturdy Truck Body (1972) Limited 1

display. Several conditions require the user to operate the system manually by switching the control to manual. Refer to the manual section below. Manual Control Once the system is turned to manual, the operation of each of the ventilation components are operated at the choice of the user. Several of the situations where the user will operate the system on manual control are listed as follows: preheat control malfunction electrical malfunction washing System Overrides With the introduction of the Series 2003 system, there are now two overrides switches located on the dash panel. The first is for the Spray Pump. With the switch in the ON position, the LED will be green, and the Pump will be manually activated. This feature may be used to utilize our evaporative cooling features while running in Auto mode. In the middle position (OFF) the spray pump is disconnected. This feature may be used in the winter under extreme cold conditions if there are fears of freezing lines. In the DASH position, the Spray pump is under the control of the dash panel, as in previous models. In DASH mode, under Manual mode of operation, the Spray pump button will activate the spray pump. The other override switch is for the Auxiliary Heater. This function identically to the Spray pump override, and may be used to disconnect the heater during warm weather months to prevent it from starting for short periods of time. Preheat The cargo area should be preheated to target temperature prior to loading. The heater will automatically turn on until the thermostat temperature is reached. The length of time required for preheat will depend on exterior conditions, temperatures and storage of shipping truck. If the cargo temperature is below target, the time for preheating the cargo area can be decreased by: ensuring heater thermostat is set equal to target temperature switching the control to manual turning on the inlet fan fully closing the damper fully opening the mixing valve switching the control to auto when the cargo area temperature reaches 85 F. Manual Control Sturdy Truck Body (1972) Limited 2

In the event of a control malfunction, turn main switch off, wait 10 seconds, then turn to auto to see if problem has corrected itself. If not, the following procedures should be followed: switch the control to manual turn on the inlet fan adjust the damper and mixing valve to suit conditions (see Table 2 on page 9) if heat is required, turn on the auxiliary heater. Turn off when the target temperature is reached. turn misters on if the interior relative humidity is less than 50% and/or the temperature is more than 90 F. Washing The controller can be turned to off during washing. If required, to decrease drying time and to prevent freezing, the following components can be manually operated: ensure heater thermostat is set equal to target temperature turn on the inlet fan open the mixing valve Mist Tank Refill The mist tank requires filling when empty. Actual time of mist operation will determine the time required to empty the mist tank. The tank should be refilled prior to loading an empty truck. A spigot is located outside of the front of the unit on the passenger side to fill the mist tank. Attach a water hose and fill the tank. Water will flow out of an overflow hose (and onto the ground) when the tank is full. Additionally, there is a cap on the tank to permit the addition of ice to the water if required. Mist Tank refill Spigot Mist Tank located inside control compartment. 3.0 Control Logic The controller operates by a series of conditions dependent on feedback from positioning of components, sensor readings, thermostat setting, and target set points. The controller will adjust system components as required to satisfy the set points. 4.0 Controller Components Sturdy Truck Body (1972) Limited 3

Dome Light Exhaust (Outlet) Fans Mix Valve Linear Actuator Water Tank Mist Pump Inlet Fans Webasto Auxiliary Heater Inlet Fans The inlet fans provide the required airflow for ventilation. There are intake fans located at the front centre of the cargo area and exhaust fans located at the front along the sides. The intake fans blow air down the centre along the length of the cargo area and the exhaust fans suck air from the sides of the cargo area. The INLET FAN switch controls the operation of the intake fans only. Mist Pump The mist pump provides pressure to operate the misters. Misters are used for two purposes: relative humidity control and evaporative cooling. Mist nozzles are located in front of the intake fans. There are 4 mist nozzles each rated at 1.5 gal/hr for a total of 6 gal/hr. The fresh water holding tank for mist water is 42 U.S. gallons. The holding tank capacity will provide continuous spraying for approximately 7 hours. Auxiliary Heater The auxiliary heater is the Webasto heater located on the floor in the control compartment. This heater is used to boost the temperature of the heating fluid coming from the truck. The auxiliary heater is diesel fired and has an auxiliary pump to increase fluid flow. Note: the pump will operate for 1 or 2 minutes after the heater shuts down in order to cool the heater. Dome Lights Control compartment cross section. Sturdy Truck Body (1972) Limited 4

Four dome lights are located in the cargo and control areas of the truck for lighting. The lights can be turned on during loading/unloading, maintenance, etc.. The dome light switch also controls a light located inside the electrical panel. Damper The damper is the top/front intake baffle door which regulates the amount of fresh air allowed into the cargo area. Side baffle doors are connected to the top/front by rods so they open and close at the same time. The side doors regulate the amount of exhaust from the cargo area. The damper is operated by an actuator. As the damper opens, more fresh air is brought into the cargo area and more air from the cargo area is exhausted to the outside. As the damper closes, less fresh air is brought into the cargo area and more air from the cargo area is re-circulated. When the control is on auto the damper will not close less than a minimum specified setting (ie., 10%) to ensure oxygen requirements are maintained. When operating in Manual Mode, DO NOT under any circumstances operate the vehicle with the damper closed below 10% when the box contains chicks. Damper exterior view Damper with actuator interior view Mixing Valve The mixing valve regulates the amount of heat that can enter the cargo area from the heater. If heat is required in the cargo area, the mixing valve will open to allow heated fluid from the heater to enter the radiator of the cargo area. The mixing valve position is operated by an actuator. Sturdy Truck Body (1972) Limited 5

Sensors Four environmental sensors are installed for monitoring and control. TEMP.1 - is a temperature sensor located near the front of the cargo area (passenger side). TEMP.2 - is a temperature sensor located near the middle of the cargo area (passenger side). TEMP.3 - is a temperature sensor located near the back of the cargo area (passenger side). OUT.TEMP - is a temperature sensor located outside of the front damper (passenger side). HUMIDITY - is a relative humidity sensor located just above TEMP.2'. Exterior mounted Temperature sensor (located on the front of the body, beside the damper door) Interior mounted sensors are located on the access doors on the passenger side of the vehicle. Sturdy Truck Body (1972) Limited 6

Displays Dash Panel (LED Display) The Series 2003 dash panel is equipped with two LED displays. The first (green), is a voltmeter, that will provide feedback to the operator of system voltage to ensure maximum operation of the system, and to assist in troubleshooting. The second (red) display shows the settings or readouts of each of the control components and sensors. The position of the damper and mixing valve (from 0 to 100% open) are also shown on the display. If this display shows and 8 or Lo, this indicates a low voltage situation. The dash panel requires a minimum of 10.5 volts to start the system, and 13 plus volts to get maximum performance from the fans. LED Voltmeter Display LED Status Display Control Dash Panel Fuses This systems uses standard automotive relays and ATO style fuses for safety. All fuses are located in the Electrical Panel (located in the truck cab, between the seats). Under no circumstances change the value of any fuses in the panel. If a fuses repeatedly is blowing, contact Sturdy Truck Body for further technical advice. Changing values of fuses will result in the damaging of the Dash Panel, or other electrically sensitive components, and may void warranty on these items. Fuses and control relays are located inside the Electrical Panel. This panel is in the cab of the truck. 5.0 Troubleshooting Sturdy Truck Body (1972) Limited 7

Several problems have been listed that may occur during normal operation of the shipping truck ventilation system and have been included in the following table. It is generally recommended to first check if the problem is control related by switching to Manual to determine if ventilation components will operate outside of the controller. If a voltage problem exists, however, some components may operate outside of the controller but not operate with the controller. Contact Sturdy Truck Body technical support for further details. Table 1: Troubleshooting # Problem Possible Cause Remedy & Explanation 1 One or more fans stop working. 2 Temperature in cargo area below or above target but system does not appear operational or to move toward target. - fuse blown. - low voltage to control/fans. a) low voltage to controller b) controller computer stalled. Switch to Manual to determine if system operates outside of controller. Check fuses and replace if necessary. Check voltage meter and locate problem of low voltage and/or charge batteries. a) Switch to Manual to determine if system operates outside of controller. Check voltage meter and locate problem of low voltage and/or charge batteries. b) Switch controller OFF for 10 seconds then turn on again. 3 Temperature in cargo is below or above target but misters not working. - mist water holding tank is empty. - mist nozzles clogged. - mist pump not operating. - fuse blown. Check mist tank and fill if necessary. Check nozzles for dirt and clean if required. Check fuse for mist pump and replace if needed. Switch to Manual to determine if pump is operational outside of control. 4 Temperature below target, damper is closed to minimum, & mix valve fully open but aux. heater not working. 5 Ventilation components not responding to control. 6 The number 8 or Lo displays on the digital readout and display doesn t change when buttons are pushed. - fuse is blown. - low voltage. - low voltage - fuses blown Switch to Manual to determine if heater is operational outside of control. Heater must have a minimum voltage of 10.5V in order to maintain operation. The controller must have a minimum of 10.5V in order to maintain operation. Switch to OFF then Auto to reset. Replace fuses if blown. - low voltage a) Switch to Off b) Start truck and charge batteries c) Switch to Manual and/or Auto and ensure all components are functioning properly. 7 The number 0 displays on the readout for target temperature, and it will not change. - The system has internally reset the programming. - turn key to set target temperature, and press the up and down at the same time. Sturdy Truck Body (1972) Limited 8

Table 2: Manual Damper and Mix Valve Control Should you need to manually run the system, use the below parameters to set the Damper and Mix Valve. # Outside Environmental Conditions Damper Setting Mix Valve Setting 1 Outside Temperature is at target temperature or higher. 100% 0% 2 Outside Temperature is 20 F below target temperature 3 Outside Temperature is more than 20 F below target temperature. 50% 50% 10% 100% Sturdy Truck Body (1972) Limited 9

6.0 Daily Check List Table 3: User Daily Checklist # Description Complete 1 Ensure body heating coil is clean. (inspect from both sides) 2 Fill mist tank. 3 Fill truck tank. 4 Check operation of inlet fans. 5 Check operation of mist pump. 6 Check operation of heater. 7 Check operation of damper. 8 Check operation of mix valve. 9 Preheat cargo area minimum 1 hour prior to loading depending on outside temperature. Make sure cargo area temperature is at target prior to loading. 10 Switch to AUTO once loading is complete. 11 Check and record temperature and humidity sensor readings. 12 Check and record voltage meter reading. 13 Check tailgate operation (if applicable) and follow maintenance instructions in manual provided 14 15 16 17 Inspected By: Date: Sturdy Truck Body (1972) Limited 10

7.0 Preventive Maintenance Every Two Weeks start heater with mixing valve fully open and let it run for 15 minutes check battery fluid check chick body charging system and replace alternator as necessary (see detailed instructions section 8.0) Every 3 Months replace any fan motors that draw more than 13 amps after running for one minute Every 12 Months replace antifreeze as recommended by chassis manufacturer check electrical panel fans Sturdy Truck Body (1972) Limited 11

8.0 Chick Body Charging System Check Equipment Required volt meter clamp style amp meter hydrometer Expected Alternator Output @ 1000 engine r.p.m. Amps cold = 215 amps hot = 190 amps Volts no load = 14.9 volts under load = 14.0 volts To Test Amps must have all truck and body systems turned on must test at output cables at alternator add output from both cables To Test Volts no load under load => engine running but nothing turned on => engine running with all truck and body systems turned on To Test Batteries Use hydrometer with truck turned off Must test each cell of each battery Notes voltage tested at equipment (e.g. fans, etc), should be about 13 volts a bad battery will cause alternator voltage output to drop Sturdy Truck Body (1972) Limited 12