HV connectivity tests after Barrel connection

Similar documents
Fuse Box Layout. Duke Atlas Group

SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1)

Contents. Formula Student UK Appendix FSUK-C-2

Solar Inverter/Charger

Feature Description. Version History

O2 Sensor Testing. If your engine has unexpectedly started to run poorly, an O2 Sensor Test should be performed.

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

620 Magnolia Avenue Suite B Ontario, CA (909) Diagnostic and Troubleshooting. Golf Cart. Revision: A Date:

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

Battery Control Center - Diesel

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter

Grounding Systems. Resistance. Resistance Grounding Systems Contents

A/C-HEATER SYSTEM - AUTOMATIC

TIME OF FLIGHT Components from:

HV/LV Memo. ECE 492 Spring Abstract. Latest Revision: 16 May Prepared by: Brendan Flood

Pectel T2 ECU Technical documentation Release 1.00 INTRODUCTION

TIME OF FLIGHT Components from:

Low and High Voltage Power Supplies

C1000 Series Automatic Cap Bank

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

STEVAL-IHM028V2. 2 kw 3-phase motor control evaluation board featuring the STGIPS20C60 IGBT intelligent power module. Description.

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

INSTALLATION INSTRUCTIONS THERMOCOUPLE EXPANSION MODULE

Introduction. Exploded View. Conveyor System - Troubleshooting Guide LAST UPDATED: 09/19/2018

CONFIGURATION DIAGRAMS

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8


LED Flasher. R1 R2 100 F + C1 100 F +

Layout Diagrams. Section CONTENTS. General Layout Diagram Floor / Roof Engine Compartment Door

Virtual Ground for HV Boosters Calibration

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

DTCM - Diagnostic Trouble Code Memory

Name Period. (c) Now replace the round bulb(s) with long bulb(s). How does the brightness change?

Electrical. The following slide shows the entire electrical overview. Take a moment to study the overview and become familiar with the components.

ADJUSTABLE PEDAL SECTION AP CONTENTS I BODY AP-1

Phaser 4600/4620 Laser Printer. Service Manual. Xerox Internal-Use Only

Solar Power Owner s Manual

POWER PROFET A simpler solution with integrated protection for switching high-current applications efficiently & reliably

Powering Schemes for the Strip Trackers

Total solder points: 126 Difficulty level: beginner advanced POWER DIMMER 230V) K8038 ILLUSTRATED ASSEMBLY MANUAL

Troubleshooting Guide

A/C Generator Systems

LS-1 Series Tungsten Halogen Light Sources

Powering Schemes for the Strip Trackers

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Zone Selective Interlock Module. For GE Circuit Breakers

SUBJECT: EB e-stroke GEN 3 Post Install Functionality Test

APSX WIDEBAND D2 AFR CONTROLLER GAUGE. Installation and User Manual. APSX WIDEBAND D2 Manual V1.0

CONTACTING CIRRUS LOGIC SUPPORT

WARNING. Trouble Shooting Slide Out Control Box For In-wall Slim Rack Systems. Content. Table of Contents:

REPAIR MANUAL HWH COMPUTER-CONTROLLED HYDRAULIC LEVELING SYSTEM 400 SERIES FEATURING: PADDLE SWITCH CONTROL AUTOMATIC LEVELING VERTICAL

15.0 SLICE Trouble-Shooting Guide

Reading on meter (set to ohms) when the leads are NOT touching

OVEN PARTS For Models: JMW9530DAW30, JMW9530DAS30 (White) (Stainless)

IM /2017 REV01 POWER WAVE S700 CE

Product Manual MNX10010 / REV B MODEL PS03

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

7. Oil Pump OIL PUMP PS-46. 7) Place the oil pump bracket in a vise, remove the two bolts from front side of oil pump. CAUTION:

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

WARNING. Trouble Shooting Control Box or For In-Wall Slim Rack Systems

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

output Output Voltage min (ma)

2002 Ford Explorer STARTING & CHARGING SYSTEMS' 'Generators & Regulators - Explorer & Mountaineer STARTING & CHARGING SYSTEMS

1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

PHOENIX42-IFT. Service Parts. Part number list on following page. 10/ True View

JConn Inv. PID Controller Instruction Manual

Product Datasheet P MHz RF Powerharvester Receiver

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

DC/DC power modules basics

Letter No. A-137 Issue Date: March 9, 2011

T-630 with John Deere Electronic Engines Troubleshooting

Document number: BL-2330 (V1.0) SERVO DRIVE UNIT. MAINTENANCE MANUAL BLIV-D Type A (1st Edition) Pub. No E (SE R1) Apr.

Maxi and Mini DC-DC Converter Evaluation Board

20-pin ECU Technical Specs. Engine Control Unit. (ECU) Technical Spec ECOTRONS LLC COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED

SUPPLEMENTAL RESTRAINT SYSTEM (SRS)

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

Section 7 - Troubleshooting Guide

Switch Machines Installation & Wiring

Lift-N-Glide Manual. Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No:

MODEL NUMBER AND IDENTIFICATION. Pag. 5 CHARACTERISTICS CHARACTERISTIC POWER, TORQUE AND SPECIFIC CONSUMPTION CURVES

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

DC/DC Power Modules Basics

Installation Manual. Trailer Edition Precedent. Battery Charger Kits and Supplemental Power Package Retrofit Kits

Jet Dispensing Underfills for Stacked Die Applications

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Idle Free Systems, Inc. Reference Guide System Component Information

Auger System - Troubleshooting Guide

SERVICE MANUAL. Pallet Trucks

MICROPROCESSOR BASED CONTROLLER

1998 Acura 3.5RL. F - BASIC TESTING' '1998 ENGINE PERFORMANCE Acura - Basic Diagnostic Procedures

APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection

Freeman 380/385 Hydro PTO Operator Controls and Baler Connection Instructions

C1219 C1219-STEERING ANGLE SENSOR ERRATIC PERFORMANCE RAM Pickup 6.7L Eng Search. 7/13/2015 Printer Friendly View

Section Five - Troubleshooting Procedures

Tip: - Control of the Heljan Container Terminal using TrainController Gold Date: Created

CABIN 400 TROUBLE-SHOOT-LIST

Transcription:

TRT detector high voltage system ATLAS Project Document Institute Document No. Created: 07/09/2006 Page 1 of 11 Modified: REV.: 1.00 HV connectivity tests after Barrel connection Procedure 1.2.8 Abstract TRT barrel. This document describes the tests performed after the initial HV harnesses connection to the Introduction HV Layout Test Procedures Chiho Wang Prepared by: Checked by: Jack Fowler Harold Ogren Seog Oh Anatoli Romaniouk Approved by:

Distribution List Page:2 of 11

Page: 3 of 11 History of Changes Rev. No. Date Pages Description of changes

Page: 4 of 11 Table of Contents Introduction HV Layout Test Procedures Appendix 1: HV Mapping from HV PS Channels to Straws

Page: 5 of 11 1 Introduction: This procedure covers the TRT barrel HV check after the HV connection is made. Testing of harnesses from USA15 to PPB1 is described in procedure 1.1.4 and should have been performed before hand. This procedure extends the tests to the detector itself. All tests are performed remotely from USA15. Some repair and trouble shooting may require access to detector front. 2 HV Layout A brief description of the TRT barrel HV connections is available in procedure 1.1.4. Detailed pin-out and mapping informations are available at TRT Barrel Twiki page https://uimon.cern.ch/twiki/bin/view/atlas/trtbarrelhv. From PPB1, a HV harness splits into individual HV coax cables and feed into 6 fuse boxes; 2 for each type of module. There are 22 HV coax for a stack of 3 modules: 6 for type 1, 6 for type 2 and 10 for type 3. Inside a fuse box, after a filter circuit, a HV line fans out to several fuses, ranging from 6 to 10 depending on module type and line position. Each fuse serves one trace on the module HV Kapton that feeds 8 straws. The HV ground in the fuse box are commoned after filter circuits and connected to the module tension plate through module HV kapton. A capacitor between tension plate and HV plate separates the high voltage on the straws from its ground. The tension plate ground is also electronics analog ground and is common to all barrel modules throught space frame. Individual grounds in HV coax are also commoned at USA15 on the face of HV PS crate. Some reference drawings and mapping information at the detector side are listed in Appendix 1 2.1 Pre-condition Complete and final connection of HV harnesses to TRT barrel. 3 Test procedures After HV harnesses are connected to TRT barrel the followings are tested from USA15 for the barrel HV integrity: 1. A capacitance and resistance measurement to check HV connectiveity from HV PS to straws. 2. A HV test at 500V to check sense wire wellness. 3.1 Capacitance measurement Tools: 1. Capacitance meter 2. Lemo connector distribution box (Figure 1) 3. Excel spread sheet for data recording.

Page: 6 of 11 Figure 1, Lemo distribution box Steps: 1. Disconnect lemo conectors from HV PS and connect to distribution box. The connector and the HV PS should have been clearly marked. If not they should be marked before continuing Do 1 stack of 8 connectors at a time. The 8 th connector is a mix from 3 stacks (Apendex 1) 2. Measure capacitance for each HV line with capacitance meter 3. Record in excel spread sheet. 4. Switch meter to resistance and check that resistance is infinity. 5. Compare measurement with data from procedure 1.1.4 and previous measurement in SR1 https://uimon.cern.ch/twiki/pub/atlas/trtbarrelhv/2006-07-13-barrel_capacitances1.xls 6. Repair any broken wire, or fuse. Comments: The capacitance value measured should be (SR1 data) + (procedure 1.1.4) 1.6nF (type 2 cable capacitance) If capacitance is above normal possibility of connected HV islands. o Check passport for record of connected HV islands o Measure resistance between HV lines (should be infinity if no connection) If capacitance is below normal (by 1-2 nf) possibility of broken fuse. o Apply 50V and measure from dummy fuse box side to determine which fuse causes problem. o Open fuse box to check/repair fuses If capacitance is very low possibility of broken line or bad resistors in the fuse box. o Since all ground lines are commoned at the distribution box, and at the detector front. No line should show a broken ground symptom, e.g. < ~8 nf. At this stage it s most likely a broken HV line unless all ground lines from this stack are broken!

Page: 7 of 11 3.2 HV test Tools: 1. HV PS crate and control software 2. Current readout and recording mechanism (excel spread sheet) Steps: 1. Check interlock for proper connection. 2. Raise HV to 500V for each stack 3. Record/observe current draw for 10 sec. 4. Diagose and repair any short circuit or excessive current draw Comment: Measure resistance from dummy side HV trace to ground to find out which HV island is shorted. The only way to find out which wire is broken is through electronics readout, or remove roof board!!

Page: 8 of 11 Appendix 1: HV Mapping from HVPS channels to Straw: The mapping table is available in excel format at TRT Barrel Wiki page: https://uimon.cern.ch/twiki/pub/atlas/trtbarrelhv/hv-straws-mapping.xls Naming convention in the table and the actual locations are explained in the following supporting figures. The HV PS side of mapping is explained in procedure 1.1.4 apendix 1.

Page: 9 of 11

Page: 10 of 11

Page: 11 of 11