GTEC Transfer switch Open transition

Similar documents
GTEC Transfer switch open transition

Transfer switch GTEC open or delayed transition

Transfer switch OTEC open or delayed transition

OTEC Transfer switch open transition

Transfer switch OTEC and OTECSE open transition

OTPC-SE Service entrance transfer switch open transition

Transfer switch OTPC open, closed, or delayed transition

Diesel generator set C17D5T series

BTPC Bypass isolation transfer switch open or closed transition

Transfer switch OHPC open or delayed transition

OTPC Transfer switch open and closed transition

CHPC Transfer switch closed transition

OHPC/CHPC Transfer Switches

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel Generator Set S3.8 Series Engine

Transfer switch OT III open or delayed transition, non-automatic

Complete Power Systems. Accountability for Every Aspect of Onsite Power Delivery

Paralleling Equipment

Automatic Transfer Switches. Global

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

Digital generator set control PowerCommand 3100

Quick Start Guide TS 910

.3 Section Waste Management and Disposal.

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

Quick Start Guide TS 910 & TS 920

Rental Power QSL9 series engine

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

PowerCommand 2.2 control system

Ground fault indication relay - H550, H666, H667, H668

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

Electropneumatic Timing Relays Series 7000 Industrial

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Cummins delivers reliable power in one easy-to-use system

Diesel generator set QSL9 series engine

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

SECTION MOTOR CONTROL

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

ASCO SERIES 185 Power Transfer Switches

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

Horizontal Circuit Switchers

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Diesel generator set QSK60 series engine

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Bypass Isolation Transfer Switches Amperes

Rental Power QSB7 series engine

GENSET CONTROL MODULE A121A / A241A

Florham Park, NJ USA Call (ASCO) for sales or service

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Bolted contact switches. Pringle switches

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

PowerCommand 2.2 control system

Diesel generator set 4BT3.3 series engine

Cutler-Hammer May 2001

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Horizontal Circuit Switchers

Bypass/Isolation Switches RTS-03 SERIES

Technical Information

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Zenith ZBTS/ ZBTSD/ZBTSCT

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Spark-ignited generator set

General + Definite Purpose Contactors

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

Diesel generator set QSX15 series engine

Safety Interlock Switch with Guard Door Locking. Narrow profile enables mounting to 2 in. square tubing or in applications with space restrictions

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Rental Power KTA50 G3 series engine

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

and Refrigeration Institute). CNX Special Purpose Contactors

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

PowerCommand 500/550 Remote Monitoring System

Power Connect TM Series RX60

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Diesel generator set 6BT5.9 series engine

Diesel generator set QSL9 series engine

QSK60 Series Gas Powered Generator Sets

Diesel generator set QSK60 series engine

Diesel generator set QSK95 series engine

Diesel generator set QSK60 series engine

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Vigilant Automatic Transfer Switches

SECTION MOTOR CONTROLLERS

PD-Series Ground Fault Circuit Protection

Transcription:

GTE Transfer switch Open transition 40-2000 amp Description GTE transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator set, or between two generators. The microprocessor control monitors utility and emergency standby generator power. When utility power fails or is unsatisfactory, the control starts the generator, then transfers the load from the utility to the generator. When stable utility power returns, the switch automatically transfers the load back to the utility. For genset-to-genset applications, the genset that is connected to the utility side of the control is the lead genset. If the lead genset goes down or is taken offline, the transfer switch starts the second genset and transfers the load. The control can be programmed to alternate between the two gensets at a set interval up to 300 hours. The fully integrated controller is designed for practical functionality, with LED indicators and digital pushbuttons for ease of operator use. ll switches meet IE 60947-6-1 31. ll switches bear the E mark. 40 1250 amp switches are certified by the hina Quality ertification entre. Features Microprocessor control - Easy-to-use, standard control. LEDs displays transfer switch status; pushbuttons allow operator to activate control test, exercise timing and transfer mode. dvanced transfer switch mechanism True transfer switch mechanism with break-before-make action. Manual operation Standard removable handle can be used to manually operate the switch after the power source has been properly disconnected. Positive interlocking - Mechanical and electrical interlocking prevent source-to-source connection through the power or control wiring. Main contacts -Silver alloy contacts with multi-leaf arc chutes are rated for 100% load interruption. They require no routine contact maintenance and provide 100% continuous current ratings. Easy to service Single-plug harness connection and compatible terminal markings simplify servicing. ccess space is ample. Door-mounted controls are fieldprogrammable; no tool is required. omplete product line - ummins Power Generation offers a wide range of equipment, accessories and services to suit virtually any backup power application. Warranty and service - Products are backed by a comprehensive warranty and a worldwide network of distributors with factory-trained service technicians. This transfer switch is designed and manufactured in facilities certified to ISO9001.

Transfer switch mechanism powerful, economical solenoid operates GTE transfer switches. Independent break-before-make action is used for 2-pole, 3-pole and 4- pole switches. On 4-pole/switched neutral switches, this action prevents the objectionable ground currents and nuisance ground fault tripping that can result from overlapping designs. mechanical interlock prevents simultaneous closing of normal and emergency contacts. Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. High-pressure silver alloy contacts resist burning and pitting. Separate arcing surfaces further protect the main contacts. ontacts are mechanically held in both normal and emergency positions for reliable, quiet operation. ontact wear is reduced by multiple leaf arc chutes that cool and quench the arcs. arriers separate the phases to prevent interphase flashover. transparent protective cover allows visual inspection. Specifications Voltage rating rc interruption Neutral bar uxiliary contacts Up to 480V, 50 or 60 Hz Operating temperature -30 (-22 F) to 60 (140 F) Storage temperature -40 (-40 F) to 60 (140 F) Humidity ltitude Total transfer time (sourceto-source) Manual operating handle Multiple leaf arc chutes provide dependable arc interruption. full current-rated neutral bar is standard on enclosed 3-pole transfer switches. Two isolated contacts (one for each source) indicating switch position are provided for customer use. ontacts are normally open, and close to indicate connection to the source. Wired to terminal block for easy access. Rated at 5 amps continuous at 100V or 2.5 amps continuous at 200V. Up to 95% at 20 Up to 2,000 m (6,561 ft) without derating Will not exceed 100 msec with normal voltage applied to the actuator and without programmed transition enabled. Transfer switches are equipped with a removable operating handle which allows operation during servicing to facilitate troubleshooting with sources of power disconnected.

Microprocessor control Simple, easy-to-use control provides transfer switch information and operator controls LED lamps for source availability and source connected indication, exercise mode, and test mode. LED status lamps also provided for control set-up and configuration Pushbutton controls for initiating test, overriding time delays and setting exercise time Field-configurable for open or programmed transition Integral exerciser clock ontrol is prototype-tested to withstand voltage surges per EN 60947-6-1 Gold-flashed generator start contacts ontrol functions Under-voltage sensing: ll phases on the normal source, and single phase on generator source. Normal source pickup: adjustable 80-95% Dropout: adjustable 70-90% of nominal voltage Generator source pickup: 90% Dropout: 75% of nominal voltage. Over-voltage sensing: ll phases on the normal source. Source pickup: 120% Dropout: 125% Under-frequency sensing: Default setting is OFF. Generator source pickup: 90% of nominal frequency Dropout: 85% of nominal frequency Normal source pickup: 80% Dropout: 70% Over-frequency sensing: Default setting is OFF Normal source pickup: 130% Dropout: 140%. Genset-to-genset sensing: Same functions as above, for lead and secondary generators. Exercise mode: The control exerciser clock can be set to operate on a 7, 14, 21 or 28-day cycle with a fixed exercise period duration of 20 minutes. convenient 12-hour offset feature offsets the exercise time by 12 hours, without having to reprogram the timer. The control can be programmed to exercise the generator with or without load. Test mode: When manually or remotely activated from the control panel, the control will start the generator and run until stopped. an be configured to test with or without load. Transition modes Open transition/programmed: ontrols the time required for the device to switch from source to source, so that the load-generated voltages decay to a safe level before connecting to an energized source. Recommended by NEM MG-1 to prevent nuisance-tripping breakers and load damage. djustable 0-10 seconds, default 0 seconds. Open transition/in-phase: Initiates open transition transfer when in-phase monitor senses both sources are in phase. Operates in a break-before-make sequence. Includes ability to enable programmed transition as a back-up. If sources are not in phase within 120 seconds, the system will transfer using programmed transition. Time-delay functions Engine start: Prevents nuisance genset starts due to momentary power system variation or loss. djustable 0-10 seconds, default 3 seconds. Transfer normal to emergency: llows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. llows staggered transfer of loads in multiple transfer switch systems. For genset-to-genset applications, delays transfer of load from lead to secondary generator. djustable 0-300 seconds, default 5 seconds. Re-transfer emergency to normal: llows the utility to stabilize before re-transfer of load. Prevents needless power interruption if return of normal source is momentary. llows staggered transfer of loads in multiple transfer switch systems. For genset-to-genset applications, delays re-transfer of load from secondary back to lead generator. djustable 0-30 minutes, default 10 minutes. Engine stop: Maintains availability of the genset for immediate reconnection if the normal source fails shortly after transfer. llows gradual genset cool down by running unloaded. djustable 0-30 minutes, default 10 minutes. Elevator signal relay: Requires optional elevator signal relay (M032). Delays transfer for specified interval to prevent a power interruption during elevator operation. Options Elevator signal relay: Provides relay output contacts for sending a load-disconnect warning signal to the elevator control. Transfer/re-transfer delay time is selectable for 0, 1, 2, 3, 5, 30, 120 or 300 seconds. (M032). Programmable exerciser clock: Provides a fullyprogrammable 7-day clock to provide greater flexibility in scheduling exercise periods than standard integral exerciser. Peaking function feature allows for generator operation during periods of high utility rates. (J030) Manual restore: Provides a key switch on the front door to allow the operator to control when the switch transfers to the available normal source.

Electrical performance The transfer switches listed below must be protected by fuses. The following WR ratings are available when protecting the transfer switch with a fuse. Short circuit ratings are stated in symmetrical RMS amperes. Transfer switch ampere Overload current (make-break test) 40, 63 95 amps 100, 125 188 amps 160, 200, 225, 250 375 amps 350, 400, 500 750 amps 630, 800 1200 amps 1000, 1250 1875 amps 1600, 2000 3000 amps Endurance cycles at current (operational performance capability) 4500 at 0 amps Operating frequency Fuse protection WR at 480V max with current limiting fuse Max fuse, size and type 1500 at 63 amps 1 per minute 26,000 amps RT16NT-00 63 amp 5000 at 0 amps 1000 at 125 amps 1 per minute 26,000 amps RT16NT-00 125 amp 5000 at 0 amps 1000 at 125 amps 1 per minute 38,000 amps RT16NT-2 250 amp 2500 at 0 amps 500 at 500 amps 1 per minute 50,000 amps RT16NT-3 500 amp 2500 at 0 amps 500 at 800 amps 1 per minute 55,000 amps RT16NT-4 800 amp 2500 at 0 amps 500 at 1250 amps 1 per 3 minutes 65,000 amps RT16NT-4 1250 amp 1500 at 0 amps 500 at 2000 amps 1 per 6 minutes 120,000 amps KRP- 3000 amp Enclosures The transfer switch and control are mounted in a key-locking enclosure. Enclosures meet IE 60947-6-1 standard. 40-500 amp switches are front-connected. 630-2000 amps are rear-connected. Standard enclosure is gray. Green is available as an option (P152). Dimensions - IP32 mp rating Height Width Door closed Door open Weight 3-pole type Outline drawing in mm in mm in mm in mm lb kg 40, 63 31.4 800 23.6 600 8.8 226 31.4 800 101.4 46 0500-6004 100, 125 31.4 800 23.6 600 8.8 226 31.4 800 105.8 48 0500-6004 160, 200, 225, 250 39.3 1000 31.4 800 8.8 226 39.3 1000 125.6 57 0500-6005 350, 400, 500 39.3 1000 31.4 800 8.8 226 39.3 1000 143.3 65 0500-6005 630, 800 53.9 1370 29.2 742 24.8 631 53.0 1348 385.8 175 0500-6006 1000, 1250 53.9 1370 29.2 742 24.8 631 53.0 1348 405.6 184 0500-6006 1600, 2000 78.7 2000 39.4 1000 44.3 1126 83.7 2126 888.9 400 0281839 Dimensions - IP54 mp rating Height Width Door closed Door open Weight Outline drawing in mm in mm in mm in mm lb kg 40, 63 34.0 864 23.3 598 11.6 296 31.4 800 110.2 50 0500-4559 100, 125 34.0 864 23.3 598 11.6 296 31.4 800 114.6 52 0500-4559 160, 200, 225, 250 41.8 1064 31.6 804 11.6 296 39.3 1000 143.3 65 0500-4560 350, 400, 500 41.8 1064 31.6 804 11.6 296 39.3 1000 160.9 73 0500-4560 630, 800 53.9 1370 29.5 750 26.6 676 53.0 1348 414.4 188 0500-4561 1000, 1250 53.9 1370 29.5 750 26.6 676 53.0 1348 434.3 197 0500-4561 1600, 2000 78.7 2000 39.4 1000 44.3 1126 83.7 2126 892.9 405 026M050

GTE Open construction 40 to 1250 amps Description The open construction GTE transfer switch combines reliability and flexibility for a variety of load transfer applications. The open construction switch has the same rugged switch mechanism, din rails, relays, and control as the standard GTE. Dimensions Front connection Rear connection Open construction Height Width Depth 2-pole Transfer switch ampere onnection Weight (kg) Outline drawing 40, 63 front 193 192 112 4.0 306-5010 100, 125 front 193 209 112 4.5 306-5011 160, 200, 225, 250 front 194 219 112 6.0 306-5012 350, 400, 500 front 290 280 132 11.0 306-5013 630, 800 rear 390 340 210 25.0 306-5014 1000, 1250 rear 390 370 250 31.0 306-5015 Height Width Depth 3-pole Transfer switch ampere onnection Weight (kg) Outline drawing 40, 63 front 193 214 112 5.0 306-4992 100, 125 front 193 239 112 6.5 306-4990 160, 200, 225, 250 front 194 254 112 8.0 306-4968 350, 400, 500 front 290 340 132 14.0 306-4970 630, 800 rear 390 405 210 33.0 306-4983 1000, 1250 rear 390 450 250 40.0 306-4985 Height Width Depth 4-pole Transfer switch ampere onnection Weight (kg) Outline drawing 40, 63 front 193 235 112 6.5 306-4993 100, 125 front 193 269 112 8.0 306-4991 160, 200, 225, 250 front 194 269 112 10.0 306-4969 350, 400, 500 front 290 400 132 18.0 306-4971 630, 800 rear 390 470 210 42.0 306-4984 1000, 1250 rear 390 530 250 51.0 306-4986

Submittal detail options mperage ratings 40 63 100 125 160 200 225 250 350 400 500 630 800 1000 1250 1600 2000 Voltage ratings R971 110 R972 115 R973 120 R974 127 R975 139 R976 220 R977 230 R978 240 R979 255 R980 277 Pole onfiguration 027 Poles - 2 (solid neutral) 028 Poles - 3 (solid neutral) 029 Poles - 4 (switched neutral) Frequency 044 60 Hertz 045 50 Hertz pplication 035 Utility-to-genset 037 Genset-to-genset System Options 041 Single phase, 2-wire or 3-wire 042 Three phase, 3-wire or 4-wire Enclosure 004 Open construction: no enclosure - includes automatic transfer switch and controls (1600 2000 amp open construction not available) 901 IP32 general purpose indoor 014 IP54 general purpose outdoor P152 Optional paint colour: Onan green M048 Perspex protective shield ontrol voltage M033 12V, Genset starting voltage M034 24V, Genset starting voltage ontrol options J030 dd-on programmable exercise clock M032 Elevator signal relay S006 Manual restore switch attery chargers K001 2 amps, 12/24 volts uxiliary relays Relays are factory installed. ll relays provide two sets of form (DPDT) contacts rated 5 amps at 250V. Relay terminals accept one 0.75 mm to two 4 mm wires per terminal. L101 24 VD oil - installed, not wired (for customer use). L102 24 VD oil - emergency position - relay energized when GTE in Source 2 (emergency) position. L103 24 VD oil - normal position - relay energized when GTE in Source 1 (normal) position L201 12 VD coil installed, not wired (for customer use) L202 12 VD coil - emergency position - relay energized when GTE in Source 2 (emergency) position L203 12 VD coil - normal position - relay energized when GTE in Source 1 (normal) position Warranty Warranty: 12 months from commissioning to a maximum 18 months after date of sale. ccessories -176 Specification sheet ummins Power Generation North merica 1400 73rd venue N.E. Minneapolis, MN 55432 US Phone 763 574 5000 Fax 763 574 5298 razil Rua Jati, 310 Guarulhos Sao Paulo EP 07180-140 Phone 55 11 2186 4195 Fax 55 11 2186 4729 Europe, IS, Middle East and frica Manston Park olumbus ve. Manston Ramsgate Kent T 12 5F United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 sia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399