DZ-03 Base Installation and Operation Manual

Similar documents
The 4-Lamp Mega Fixture Built-in Barndoors Removable Reflector, Louver and Lamp Harness Twist-on Locking Center Mount True Match daylight, tungsten

Differential Pressure Sensors

Differential Pressure Sensors

Part No Series 12 to 144 Volt TSM Series. High Efficiency Intelligent Charger. Offered by Lithionics Battery for Use in Conjunction

BUTTON CELL CR2450S BRIEF SPECIFICATION

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

THREE-PHASE FOUR-WIRE, CT TYPE, 1.5(6A) User Manual for SGE-353

CH4100 Series High Efficiency Intelligent Charger. ThunderStruck User Manual Ver. 1.02

TSM2500 Series High Efficiency Intelligent Charger. ThunderStruck User Manual Ver. 1.05

Rotary actuators for ball valves

COIN CELL CR2477 BRIEF SPECIFICATION

TS93 EMF T/PT/TDE. Surface applied door closer

Low Pressure Sensor. Overview. Specifications. Installation and Operation

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

AV-W. Wind Speed and Wind Speed & Direction Sensors

D-Drive Controller Retrofit Instructions

TECHNICAL INFORMATION

PDI PowerWave 2 Bus System

SPARE PARTS CATALOGUE 2013

2003 Chevrolet Impala LS

SUB-WOOFER SYSTEM OPERATING INSTRUCTIONS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES... 3

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Electronic Circuit Breaker ESS20-0..

INSTRUCTION MANUAL SINKER. By HAY

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

blocks Interconnection fuses &

Catch Eco Range : Technical Specification Sheet

NUMBER: S.M. REF.: Listed in Table ENGINE: EPA04 MBE 4000 DATE: September 2009

Foreword. Manual instruction

CAST PIPE FITTINGS COUPLINGS

Differential Pressure Sensors

Differential Pressure Sensors

Condensation monitor

TECHNICAL INFORMATION

: B3; B5; B14; B34; B35; V1

HBDBM High Bay Series

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

INSTALLATION MANUAL FSS1 HIGH SECURITY DOOR MONITORING SENSOR

January 2018 PRICE SCHEDULE B 1.5 Maximum Security Slide Gate Operators

PSL2 Assembly guide. PSL2 Assembly guide. Resistors. Test pins. Document revision 1.1 Last modification : 30/05/08

Product Data Sheet. Damper Interface. Features

Predator Model Number Nomenclature

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

HomeWorksR QS Wired MaestroR Architectural Local Controls

Showering in comfort and safety

GS-AQ1000 VOC Indoor Air Quality Sensors

MTF. Technical features

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

EEMB CO., LTD. Lithium Manganese Dioxide Battery Specification. Button Type. Prepared Checked Approved. Signature Checked Approved

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Installation & Operating Instructions

Differential Pressure Switch QBM81-

470nF REG1 LM2940. VR3 100k 10k VR1 100 F. 470pF. 100nF. 100nF RELUCTOR Q2 BC k. 10k TP GND. 2.2nF TO RELUCTOR. 470nF REG1 LM2940 REG1 LM2940

The answer of power supply from Luci. Luci Power Supply AC100v-242v. series

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

MODEL HM A01

Model 124 Filter Minder & Model 124

ZIP LIGHT LED LUMINAIRE

FlowCon Energy FIT System

Drawing A Crankcase, Cylinder

Multi Pad for NLX/iMD Installation Manual

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

INSTALLATION, OPERATION + MAINTENANCE

Simple Eurorack Row. Kit Builder's Guide. 4mspedals.com

ADN-W L 10. Battery Charger. Instruction manual

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

DBR3, 4500W, 9R, TS - BRAKING RESISTOR

7100SZ Series SafeZone Installation and Instruction Manual

TA V TA V

Dinosaur Flexible Wiring Duct

ALD Dimmer Enclosures

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

MCD Pump Application Module

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Direct Coupled Damper Actuator Model MY6050A1001

NEW. MAGNASPHERE L2C HSS Technology. Only concealed contact to meet UL 634 Level 2 High Security Standard

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

1800/1000 Frame RC Snubber Board IS200RCSAG1A

Cybex Arc Trainer 610A Service Manual. Main Assembly

HS6B Series Subminiature Interlock Switch

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

R O M ROLL-UP SHUTTER TM D00R SERIES III INSTALLATION INSTRUCTIONS

Advanced Materials The Key to Progress

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

SPARE PARTS LIST PAGE 1

User Manual. Solar Charge Controller 3KW

Product discontinuation. Notices. Measuring / Motor Protective Relays. Discontinuation Notice of Single-phase Voltage Relay K8AB-VW[].

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

SCM CLOCK MOVEMENT 03 USER MANUAL

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Magnetic Contacts. GE Security. Specialty Mount Magnapull contact mini Magnapull magnetic pull-apart cord

R-BBU BATTERY BACK-UP UNIT INSTRUCTION MANUAL

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

WIRING THE HEATER POWER SUPPLY

MVSS. Technical features

MS.RAJA ELGADFY/ELECTROMAGENETIC PAPER3

Transcription:

(Issue 1.0, August 2004)

CONTENTS I General... 1 II Technical Specifications... 1 III Mounting and... 1 IV Cautions... 3

I General is used to mount conventional and intelligent smoke, heat and combination detectors as their conductive base. It s made of flame-resistant plastic ABS, which is a UL94 listed material. It features attractive appearance, novel structure and stable performance. Its flame class is V-0. During installation, you can easily fix the base before connecting cables, and then twist the detector onto the base. II Technical Specifications 1. : Polarized two-wire with power cable. 2. Operating Environment: Temperature 0 +37.8 (UL268) -10 +50 (GB4715-93) Relative Humidity 95% no condensation 3. Dimension Diameter 103mm Height 14mm 4. Material and Color ABS ivory white 5. Flame Class V-0 6. Weight About 54g 7. Mounting Hole Distance 45mm 75mm 8. According to Standard UL268 III Mounting and 1. Appearance GB4715-93 Appearance of the base is shown in Fig. 1. Record Label A B Description Label Mounting Hole Anti-tamper Hole Fig. 1 Appearance of 2. Mounting Method DZ-03 base can be fixed on an embedded box through its mounting hole with two Page 1

M4X12 cross recessed pan head screws. If an embedded box is not used, it can also be mounted on relatively soft structures like wood or ceiling with two M4X25 wood screws, or on hard structures like brick or cement with two plastic sleeves, as shown in Fig. 2 (a) and 2 (b). 6 expansion bolts with Hole Tube Embedded Box Base Tube Base Fig. 2 a Mounting with embedded box Fig. 2 b Mounting without embedded box 3. 1) Method As shown in Fig. 2, there are four terminals with numbers on the base, 1 connects with the anode of the output end of compatible controller, 2 connects with terminal No. 1 of the next base as output, 3 connects with terminal No. 3 of the next base and the cathode of the output end of compatible controller, 4 doesn t connect to any wires but is used to fix the detector accessorily. 4.7k/1W terminal resistor can be connected between terminal 2 and 3 of the last base in a loop. Connection of the base into the system is shown in Fig. 3. There are two marks on point A and B of the orientation base, to ensure there is only one installing position. Output+ Compatible Controller Output- 4.7k Terminal Resistor Fig. 3 System Connection The base can be prevented from tamper by twisting a ST2.9 6.5 cross recessed pan head tap screw into the anti-tamper hole on one side of the base after mounting the detector onto the base. This screw can only be removed by special screw driver. Please note to use this function where necessary to avoid difficulty in maintenance. 2) Wires 227 IEC 06 cable with cross section not less than 1.0mm 2 can be used. Page 2

IV Cautions 1. Be careful not to damage the base during maintenance. 2. Please mount and maintain the base according to manufacturer s instruction or relative national code to ensure it works properly. 3. The base should be checked at least once every year to ensure good contact with the detector. Page 3