Tidal Series 5. Level Control For Dry Bulk Materials

Similar documents
Drop Forged Chain For Conveyors & Elevators

MUCON KEK GARDNER PPS. kemutec. Specialists in Powder Processing Technology. Iris Valves. Iris Valves. Iris Valves

COS BEN. Product Catalogue. E Q U I P M E N T S

Schenck Process industrial air filters the smart dust collection solution

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

UNIDIRECTIONAL Knife Gate Valve

Product information MBA200. A Level Indicator with Rotating Paddle for Bulk Material TYPE MAIHAK MADE IN GERMANY

PKL Pneumatic Impactors

Syntron Pneumatic Vibrators

HA Thickness Gauge IS:2386 (part 1)- 1963

ANSI Z50.1. Safety Standards

TROUGH SCREW CONVEYOR NEXT LEVEL 1 TROUGH SCREW CONVEYOR. Next Level! Technical Data for Trough Screw Conveyors Next Level!

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

HOPPER SHAPE KNIFE GATE VALVE

Quality in vibrators. Pneumatic vibrators for industries. Conveying Filling Compacting Separating. Detailed technical data:

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

EXTRACTAVATOR PRODUCT CATALOG ADAPTIVE MIXING TECHNOLOGY

BIDIRECTIONAL WAFER Knife Gate Valve

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

BIDIRECTIONAL WAFER Knife Gate Valve

Controls F792 Switchbox LP Series

KNIFE GATE VALVE Product Ref. : KG02W/KG02L

Dalamatic Dust Collectors

BULK SOLIDS FEEDING. Distributor of. Rotary Valve RV RVR RVR

Mucon Iris Valves PROCESSCOMPONENTS MUCON KEK GARDNER PPS

BIDIRECTIONAL Knife Gate Valve

ROTARY PADDLE LEVEL SWITCHES

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

POWTEK. Top Quality in Pneumatic Vibrators

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

MFKG Single-Shaft Continuous Mixer. Intensive mixing of fine materials

BLOWING SEAL VALVES. everything under control...

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

KNIFE GATE VALVES -- MODEL A

INFASTAUB. Breathe The Difference: Pure Air. INFA-JET Pocket filter

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

The Cement Industry. How can Kinetrol help your business? Cement Manufacturing Process. Pneumatic Vehicle Unloading. Silo Discharge.

Valve Solutions for the Bulk Material Industry

Bucket Elevator Belt Bucket Conveyor

HOPPER SHAPE KNIFE GATE VALVE

Bulletin No Vibrating Conveyors. For Bulk Material Flow, Batch Loading and Unit Handling

UNIDIRECTIONAL WAFER Knife Gate Valve

RAPIDMIX 400CW. Length of Machine (19.5m) Length when erected Width of Machine 9-10 (3.00 m) Width Same

VSR BLASTER air cannons for pneumatic activation of bulk materials in silos and processing plants

Vibftlting Conveyo,s Vibftlting peedeps

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF

1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications

INFASTAUB. Breathe The Difference: Pure Air. INFA-JETRON Silo filter / Dust collector

Volumetric Feeders, AccuRate Series

SERIES TECHNICAL SPECIFICATIONS MIDWEST COMPACULOADER I INTERNALLY VENTED TOP FEED DRY BULK LOADING MODULE MCL I

Engineered Gate Technologies SLIDE GATES PLUG VALVES DIVERTER VALVES

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

PROCAP Capacitance Level Sensors

IEC Limit Switches Selection Guide

KLINGER BALLOSTAR KHE

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Warning. Document ref: A October 2015

KNIFE GATE VALVES -- MODEL D

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

UAHT BRAKE CYLINDERS. operation & maintenance instruction , S.12 NOVEMBER, Supersedes issue dated November, 1986

Hazardous Factory Sealed Control Devices

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Soliswitch FTE30. Technical Information

Silo Description. From 1200cf to 4800cf Featured Options. Specifications Storage in Cubic Ft

UNIDIRECTIONAL WAFER Knife Gate Valve

Mobile recleanable HEPA filter units for a flow of m 3 / h

Installation & Technical Guide. Domestic & Commercial.

Geo. Robson & Co. (Conveyors) Ltd Coleford Road, Sheffield, S9 5PA Tel. +44 (0) Fax. +44 (0) Registered in England No.

Dry Chemical Feed Systems

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms.

UNIDIRECTIONAL Knife Gate Valve

INSTALLATION, OPERATION AND MAINTENANCE MANUAL OF KNIFE GATE DURGA VALVES PVT. LTD. ICHAPUR ROAD, CANAL SIDE, SANTRAGACHI, HOWRAH

PROCAP Capacitance Level Sensors

GDP Mechanical Diaphragm Pumps

VSR BLASTER air cannons for pneumatic activation of bulk materials in silos and processing plants

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

ACOUSTIC CLEANING SYSTEMS. Information Brochure.

Technical changes kept in reserve THROUGH CONDUIT KNIFE GATE VALVE

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Performance. Sound Levels. Impellers. Motors. Accessories

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

IEC Limit Switches Selection Guide

Reverse Pulse Bag Filters

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Pressure switch for gas, GW 500 A4 GW 500 A4/2

AERZEN BULK VEHICLE BLOWER

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

L15 HEAVY DUTY KNIFE GATE VALVE STANDARD PARTS LIST

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

DRY BULK MATERIAL HANDLING COMPONENTS. AFTER-MARKET SPARE PARTS. PNEUMATIC CONVEYING EQUIPMENT. PNEUMATIC CONVEYING COMPONENTS & SPARE PARTS

UNIDIRECTIONAL Round Guillotine Damper

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Operating Instructions

Transcription:

Tidal Series 5 Level Control For Dry Bulk Materials

Introduction Members of the Schenck Process Group, Stock Redler Ltd are leading providers of feeding, automation and bulk solids handling solutions. The Schenck Process Group are global market leaders for solutions in measuring and process technologies in industrial weighing, feeding, screening and automation. Always close to the customer, with an unrivalled global network of operating companies we are your competent global partner for weighing, feeding, screening and automation solutions throughout the process industries. Our philosophy is based on... Continuous product development Best practice approach to applications Raising industry standards Capabilities Single machine Multiple machines System solutions Installation & commissioning Plant layout & integration Engineering & contract management Professional customer service approach Industries Power, Coal, Steel, Cement, Mineral Chemical, Grain Processing, Brewing/Malting Flour/Feed Food, Particle board, Water Treatment The Schenck Process Group develops, manufactures and markets a full range of solutions, products and turnkey systems on the basis of combining process engineering expertise, reliable components and field-proven technology. Members of the Schenck Process Group are: How the Tidal Operates The Tidal Control Unit consists of a diaphragm whose movements are transmitted by a lever to an electrical switch which is enclosed in a housing of which the diaphragm forms one side. Bolted to the side of the chute, hopper or bunker, the movement of the diaphragm caused by accumulation of material, is used to actuate the switch to stop or start machinery or operate signal lamps and hooters. Units are readily available for working in conjunction with most powdered or granular materials up to 40-50mm ( 2-2 ) in size with a minimum loose bulk density of approximately 300kg/m 3 (20lb/ft 3 ). The characteristics of the material should be such that it will flow sufficiently well to exert a side pressure against the diaphragm without any tendency to cling or bind together and that it will fall freely away without undue sticking or caking over the diaphragm as the level of the material drops in the bin. The largest lumps of material should not be so large as to be likely to bridge across the diaphragm. The customer should satisfy himself that his particular material fulfils the above requirements but should there be any doubt we would be pleased to supply a unit on sale or return for test purposes. The diaphragm reacts to air pressure and we do not recommend the use of these units for pneumatically fed installations unless a customer is satisfied that he can satisfactorily balance the pressure both sides of the diaphragm.

Specifications The housing The housing is of aluminium to BS 490:988, the body to LM25 and the cover to LM6, both of which are gravity die castings having a high resistance to corrosion, painted a silver grey hammer finish. An epoxy painted version for additional protection against corrosion is also available to order. One conduit entry is provided tapped M20 x.5. The breather hole adjacent to the conduit entry is tapped /8 BSP enabling client to fit a pipe between the housing and the bin, via a manometer or other form of dust trap, to balance any differential pressure such as with pneumatically fed installations. A filter is usually fitted in the breather hole to prevent the ingress of dust from a normal atmosphere. This should be removed when making pipe connections. A gasket and four M0 x 6 hex. set screws are supplied for mounting. Diaphragms Nitrile Rubber Diaphragms For general use within the range of -20ºC to + 00ºC (intermittent + 30ºC). Resistant to mineral and vegetable oils and acids; odourless, tasteless and suitable therefore for use with foodstuffs. Silicone Rubber Diaphragms Suitable for use within the range -70ºC to + 205ºC (intermittent + 250ºC). Resistant to animal, vegetable and heavy lubricating oils. Polyurethane Diaphragms Abrasion resistant material with dry temperature range -40ºC to + 80ºC (intermittent + 00ºC). For moist environments the temperature should not exceed 50ºC Resistant to petrol and lubricating oils, grease, most solvents and weak acids. Diaphragms are normally secured to the face of the housing by a polypropylene ring but mild steel rings are also used with silicone rubber and polyurethane diaphragms. The Switch Both the standard switch and the heat resisting switch are single pole changeover micro switches. Each has three contacts, two fixed and one movable which alternately contacts one or other of the fixed contacts. One fixed contact is normally closed, the other normally open. Pressure on the Tidal Control diaphragm opens the normally closed circuit and closes the normally open circuit. Release of the diaphragm permits the switch automatically to return to its original position. The appropriate connections are marked on the switch. The standard switch is suitable for the temperature range of -40ºC to +85ºC. A heat resistant switch up to +250ºC is also available. Although units can be supplied to order fitted with two standard micro switches it is difficult to ensure simultaneous operation on both switches and it is therefore recommended that relays are employed to obtain any additional contacts. The unit is not certified as flameproof. Where conditions allow the use of intrinsically safe apparatus, the Tidal Control may be used in these areas providing it is connected to an approved intrinsically safe circuit. Loads (amps) Typical Installation Arrangements This method is satisfactory with a low head of material, but the feed to the hopper should be arranged so that lumps cannot drop on to the Tidal Control diaphragm. When considerable pressure is expected the unit may be mounted vertically. The shelf above the unit can be hooded to prevent accumulation of dead material. Conveyor High Tidal Low Tidal Normal Tidal Control Switch Type Heat Resisting Volts up to 250 AC 380 AC 480 AC up to DC 30 DC 50 DC 75 DC 25 DC 250 DC up to 480 AC up to 75 DC 25 DC 250 DC Resistive 5.25 0.75 0.50 0.25 0.5 0.25 Inductive 5 4 0 5.25 0.30 0.05 0.03 To keep bunker full between high & low Tidals automatically Stopped by Tidal Control on discharge chute to prevent choking of conveyor or elevator The decision to use the Tidal Control Unit for low level indication must take into account the fact that low level units are covered for much of the time by material. Some materials have the ability to agglomerate and interfere with the free movement of the diaphragms, and also low level units are subjected to rapid wear by the frequent sliding of abrasive materials across their diaphragms

265mm (0.4 ) 250mm (9.84 ) 70mm (6.69 ) 250mm (9.85 ) 70mm (6.69 ) TIDAL CONTROL 6 Holes mm Dia equi-spaced on 240mm P.C Dia for M0 x 6 Hex. set screws 58mm (2.2 ) 25mm (4.92 ) Planning In Detail 73mm (2.87 ) 0mm (0.39 ) 2.5mm (0.49 ) 22mm (8.35 ) Dia. 26mm (8.5 ) Dia. hole required in bin wall Conduit entry tapped M20 x.5.5mm (0.06 ) thick gasket Bunker side 6mm (0.25 ) thick mounting plate Typical Wiring Diagrams Normal Tidal Control Stopped by Tidal Control. On discharge chute to prevent choking of conveyor or elevator Conveyor High Tidal Low Tidal Stopped by Tidal Control on. L On bunker to stop abstracting conveyor when bunker is empty To keep bunker full between high and low Tidals automatically Tidal Control Normal L Tidal Control Stop Start No - Volt Circuit D.T.L Contactor Starter Tidal Control High Tidal L Opens Lock Stop When Covered Stop Start No - Volt Circuit D.T.L Contactor Starter Opens When Covered Low Tidal Start L2 L2 Conveyor Contactor L2 Features and Benefits Control flow and storage of product within a bulk handling system. Assists with the control of product Readily fitted Robust aluminium body Choice of diaphragms Adjustable for operational pressure Low cost installation Important Safety Information Caution: The Tidal Control Unit is not suitable for wash down with high pressure water jets. The unit is not certified as flameproof, the Tidal Control Unit may be used in these areas providing it is connected to an approved intrinsically safe circuit. Tidal Unit Control Range Diaphragm Type Nitrile Rubber Silicone Rubber Silicone Rubber Polyurethane Silicone Rubber Retained By Polypropylene Ring Polypropylene Ring Mild Steel Ring Mild Steel Ring Mild Steel Ring Micro Switch Type Heat Resistant One Switch 042/072 042/075 042/074 042/073 042/082 Unit Assy. Ref. No. with Two Switch 042/078 042/08 042/080 042/079 -

Drop Forged Chain For Conveyors & Elevators RoCon Rotational Control Unit Installation The Tidal Control Unit should be mounted either on a vertical face or at an inclination such the accumulating material will exert sufficient pressure to depress the diaphragm and receding material will freely gravitate clear. Units mounted on an inclined face are suitable with a limited head of material but the feed should be such that the material does not drop directly on to the diaphragm. The gasket provided should be fitted between the Tidal Control Unit and mounting face. The Tidal Control Unit MUST be electrically earthed, a suitable earthing point is provided and marked in the unit, and the circuit to which the unit is connected MUST be suitably protected The Tidal Control Unit MUST be positioned with the cable entry pointing downwards and if a cable gland is used it must be sized to suit the cable. Maintenance The Tidal Control Unit MUST be electrically isolated before removing the cover to access the limit switch or adjust the pressure spring If the unit is used on a silo, ensure the material level in the silo is below the mounting position BEFORE removing the unit from its fixings. Periodic inspection should be carried out, particularly of the diaphragm, which should be replaced if wear or loss of flexibility is apparent. The diaphragm is secured by a ring screwed to the face of the housing, one hole of which is offset to ensure that the position of the ring remains constant and when refitting a diaphragm it is therefore important to ensure that all holes match before inserting the screws. The breather vent provided adjacent to the cable entry is essential for correct operation of the unit. Check regularly for any dust build-up that impair its efficiency. Adjustment for Pressure A coil spring maintains a constant pressure against the lever operating the switch and frees the switch actuator lever when the depressed diaphragm is relived of pressure. The pressure of the spring is variable by means of a nut. When the Tidal Control has been installed the nut may be adjusted, if necessary, so that the switch or switches operate when the diaphragm is between a half and three quarters covered with material The Tidal Control Unit MUST be eclectically isolated before removing the cover to access the limit switch or adjust the pressure spring Container Loading System Circular Bin Discharger Bulk Reception Unit Tidal Control Unit

Stock Redler Limited Redler House Dudbridge, Stroud Gloucestershire GL5 3EY England T +44 (0) 453 763 6 F +44 (0) 453 763 582 sales@redler.com www.redler.com Publication No. 27/03 Schenck Process GmbH Pallaswiesenstraße 00 64293 Darmstadt Germany T +49 6 5-32 0 28 F +49 6 5-32 72 sales@schenckprocess.com www.schenckprocess.com