ECHOTEL 961/962 LOOP POWERED

Similar documents
ECHOTEL MODELS 915-P / 915-W

ECHOTEL 961/962 LINE POWERED

ECHOTEL 961/962 LOOP POWERED

ECHOTEL 961/962 LOOP POWERED

SOLITEL. Vibrating Rod. Level Switch. for Solids. Installation and Operating Manual. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx

VIZUAL. Magnetic. Level. Indication. Installation and Operating Manual For the Magnetic Level Indicator (MLI) 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx.

Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

INSTALLATION / INSTRUCTION MANUAL

Series V. Electric. switch mechanisms. and housings. Installation and Operating Manual

Installation and Operating Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

THERMATEL MODEL TD1/TD2

Tuffy Liquid Level Controls with Pneumatic Switch

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

OPTISWITCH 4000/5000. Vibration level switches for liquids

Level Measurement Point level measurement - RF Capacitance switches

EZ Modulevel. Displacer. Operated. Level/Interface. Measurement. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx. Installation and Operating Manual

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Series K Pneumatic Switch Mechanism

Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

THERMATEL THERMAL DISPERSION

F10. Vane type flow switches INSTRUCTION MANUAL AND PARTS LIST AGENCY APPROVALS DESCRIPTION OPERATING PRINCIPLE

Echotel Trident 91S/92S Ultrasonic Level Switches

Flap-Type Flow Meter Prall

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

SITRANS P measuring instruments for pressure

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Point level measurement Capacitance switches

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

J52 Refrigerant Level Switches

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

For Hazardous Locations

Type MR 783 Magnetic level switch

Thermatel. Model TD1/TD2. Thermal Dispersion Flow/Level/Interface Switch. Installation and Operating Manual. with spherical probe

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

SATRON VT Pressure Transmitter

Level Measurement Point level measurement - RF Capacitance switches

Material pressure (bar) (Cv (US) kv x 1,2 Seat

KENCO ENGINEERING COMPANY

Tuffy Liquid Level Switches

Thermatel Model TD1/TD2

SATRON VDt Differential Pressure Transmitter

Mobrey MSM400 Ultrasonic sludge density measurement system

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

BM 26 BASIC/ADVANCED Technical Datasheet

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

SATRON VVFe Pressure Transmitter

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Ultrasonic Two-Wire Point Level Control

Series 3730 Electropneumatic Positioner Type

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Capacitive level sensors CLS 23

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Solenoid Valves Type 3963

Compact System NRGS 11-2 NRGS Original Installation Instructions English

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Ar-Mite TM Low Flow Armored Flowmeter

Level Limit Switch liquiphant FTL 365 / FTL 366

Masoneilan Series

DIAMOND POINT VIBRATING PROBES

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

RS85 Vibrating fork level switch

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

GA 24 Heavy-duty variable area flowmeter

Operating Instructions April 2008 SITRANS LVL200E

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Overview. Specifications. Applications

BM 26 BASIC/ADVANCED Technical Datasheet

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

JUMO dtrans p20 DELTA

TORRIX Magnetostrictive level sensor

Insertion magnetic inductive flowmeter

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output

RF Point Level Control with Sensor Monitor

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

PPT 802, Proximity Probe Transducer System

Design and application

FICHA TÉCNICA DE PRODUTO

Electronic Limit Switch Type

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Instruction Manual September 2010 SITRANS LVL200S

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Transcription:

ECHOTEL 961/962 LOOP POWERED Installation and Operating Manual Ultrasonic Contact Level Switch 7xxx 6xxx 5xxx 4xxx 3xxx 2xxx 1xxx

UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours. Check the contents of the carton/crates against the packing slip and report any discrepancies to Magnetrol. Check the nameplate model number (Model number/approvals as per inserted separate sheet) to be sure it agrees with the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. Nameplate: - part number - serial n These units are in compliance with: 1. The EMC directive 89/336/EEC. The units have been tested to EN 61000-6-4 & EN 61000-6-2. 2. Directive 94/9/EC (ATEX 95A) for equipment or protective system intended for use in potentially explosive atmospheres. EC-type examination certificate number ISSeP06ATEX011X - intrinsically safe and ISSeP06ATEX008 - explosion proof. 3. The PED Directive 97/23/EC (pressure equipment directive). Safety accessories per category IV module H1. Special conditions for ATEX Intrinsically safe use: Materials marked as Category 1 equipment and used in hazardous areas requiring this category, shall be installed in such a way that, even in the event of rare incidents, the aluminium enclosure cannot be an ignition source due to impact or friction. MOUNTING Ambient temperature: -40 C (-40 F) to +70 C (+160 F) Filling line Hi/Hi alarm Pump control High alarm High alarm Low alarm Max pressure: metal transducer: 138 bar (2000 PSIG) plastic transducer: 7 bar (100 PSIG) Max temp: metal transducer: +165 C (+325 F) plastic transducer: +120 C (+250 F) Min temp: -80 C (-110 F) Auto fill or empty pump control min 8 cm (3") max 318 cm (125") Pump protection Pump Threaded 1" BSP connection Welded flange ANSI/DIN connection Varivent connection Sanitary 3A connection 2

WIRING Echotel 961 electronics Echotel 962 electronics MODEL 962 FAULT TEST Hi 21 Lo 3.6 MODEL 961 LOOP TEST 8 16 F TIME A DELAY U L T + External grounding screw, only for ATEX explosion proof units. FAULT LOOP TEST TEST Hi 21 Lo 3.6 TIME DELAY 8 12 16 + Cable gland Ground + Plugged entry Shield to green grounding screw Shield not connected Standard shielded twisted pair cable (recommended but not needed when wired as per NAMUR NE 21 for field strengths up to 10 V/m). HAZARDOUS AREA SAFE AREA Standard trip amplifier card Important: Connect the unit to the ground for avoiding earth potential drifts. USER INTERFACE Echotel 961 Echotel 962 FAULT TEST Hi 21 Lo 3.6 LOOP TEST MODEL 961 8 16 F A U L T TIME DELAY + Time delay potentiometer FAULT TEST Hi 21 Lo 3.6 LOOP TEST MODEL 962 8 12 16 TIME DELAY + Time delay potentiometer Testing fault signal Testing loop signal Safe green LED (8 ma) Alarm yellow LED (16 ma) Separate fault red LED Testing fault signal Testing loop signal Safe green LED (8 ma) Lower gap yellow LED (12 ma) Upper gap red LED (16 ma) 3

SET UP AND FUNCTIONS Set up High Low Level Failsafe selection: ➀ In «Hi» position, the current will shift to 12/16 ma (report alarm) when the transducer is wet. In «Lo» position, the current will shift to 12/16 ma (report alarm) when the transducer is dry. In both positions, the current will stay at 8 ma to report a safe condition. Fault selection: Select for which signal the unit should report a malfunction 21 ma (±1 ma) or 3,6 ma Time delay setting: Turning the potentiometer clockwise will increase the time delay from 0,5 s to 45 s. Time delay is typically used where turbulence, boiling or splashing can cause false level alarms. Indication Echotel 961 Failsafe ➀ mode Level Output signal 8 ma green LED 16 ma yellow LED Fault red LED «Hi» High Level Failsafe 8 ma (± 1 ma) ON OFF OFF 16 ma (± 1 ma) OFF ON OFF «Lo» Low Level Failsafe 8 ma (± 1 ma) ON OFF OFF 16 ma (± 1 ma) OFF ON OFF Fault LED is ON = Fault indication Echotel 962 Failsafe mode Level Output signal 8 ma green LED 12 ma yellow LED 16 ma red LED 8 ma (± 1 ma) ON OFF OFF «Hi» High Level Failsafe 12 ma (± 1 ma) OFF ON OFF 16 ma (± 1 ma) OFF OFF ON 8 ma (± 1 ma) ON OFF OFF «Lo» Low Level Failsafe 12 ma (± 1 ma) OFF ON OFF 16 ma (± 1 ma) OFF OFF ON All LED s OFF = Fault indication ➀ Use the following settings to replace Echotel 915 series with the new Echotel 961 series: For High Level Failsafe, use «Lo» setting = low current draw (from 16 ma (safe) to 8 ma (alarm)) For Low Level Failsafe, use «Hi» setting = high current draw (from 8 ma (safe) to 16 ma (alarm)) 4

MAINTENANCE Manual Testing Loop Test: (8 ma / 12mA / 16mA): Pressing the Loop Test pushbutton, will manually test the loop and connected actuators/indicators. The loop test forces the output and corresponding LED s to shift from 8 ma to 12 ma (only 962) to 16 ma back to 8 ma. The time delay setting is not active during testing. Fault Test (3.6 ma /21 ma): Pressing the Fault Test pushbutton for min 2 s, will manually test the fault output and connected actuators/indicators. The fault test simulates a circuit failure and forces the output to either 3.6 ma or 21 ma. The time delay setting is not active during testing. Troubleshooting Problem Action/Indication Solution No loop signal No LED s are ON Check wiring / input power Check for malfunction (962). See below No change in output between wet gap / dry gap Gap may be plugged by solids / dense foam Clean the transducer Gap is out of reach of liquid Check mounting section on page 2 and relocate the unit or check blocking valves. Chattering output Excessive aeration / Turbulence Introduce a time delay Check input power Relocate the switch Fault LED is ON (961) All LED s OFF (962) A system fault has been detected Press «Loop Test» pushbutton to identify the problem: Check input power * --- * : 1 flash (red LED) Check wiring between transducer and electronics or replace transducer. ** --- ** : 2 flashes (red LED) Replace electronics *** --- *** : 3 flashes (red LED) The unit senses excessive noise interference. Check shield connection or eliminate interference from a walktietalkie, radio, mechanical vibration from a nearby source 5

REPLACEMENT PARTS Replacing electronics/transducer Echotel electronics can be removed in the field under process conditions. Follow below steps to exchange electronics/transducer: Note: Adjust set up of the replacing electronics following the settings of the old electronics (see configuration section) 1. Disconnect power before removing the housing cover 2. Remove power/output wires (a) 3. Click out the protection cap of the electronics (b) 4. Remove the 2 bracket screws and slide out electronics (c) 5. Remove the transducer wires (see Wiring section) (d) 6. Re-assemble following the same procedure in opposite way. Make sure that the tip on the bracket of the electronic block is seated properly in the corresponding recess in the housing base - (e) Replacement parts No. Description Part Number 1 Cast aluminium cover Blind With window Deep drawn stainless steel cover Blind With window 004-9192-009 036-4410-010 036-5702-003 036-5702-002 2 O -Ring 012-2201-237 3 Remote transducer housing 004-9193-002 4 Electronic module for industrial housing (cast aluminium or cast SST) 961 - Exi/Exd 961 - GP 962 - GP/Exi/Exd Electronic module for sanitary housing (deep drawn 304 SST) 961 962 089-7259-005 089-7259-003 089-7258-003 089-7256-003 089-7257-003 5 Transducer See model identification b c 1 2 4 3 a 4 d 4 e 5 6

MODEL IDENTIFICATION A complete measuring system consists of: 1. Echotel 961/962 electronics 2. Echotel 9M1/9M2 transducer 1. Code for Echotel 961/962 electronics BASIC MODEL NUMBER 9 6 1 Echotel 961 electronics for single setpoint 9M1 transducers 9 6 2 Echotel 962 electronics for dual setpoint 9M2 transducers INPUT POWER 5 0 A 2-wire loop powered with current shift output ACCESSORIES 0 Blind housing cover 1 Housing cover with glass window (for aluminium housings only) MOUNTING 0 Integral mount electronics APPROVALS A ATEX II 1 G EEx ia IIC T5, intrinsically safe (except deep drawn SST housing) 1 General purpose (& I.S. FM/CSA) C ATEX II 1/2 G EEx d IIC T6, explosion proof HOUSING / CABLE ENTRY 1 Cast aluminium housing with M20 x 1,5 cable entry (2 entries one plugged) 0 Cast aluminium housing with 3/4" NPT cable entry (2 entries one plugged) 3 Cast stainless steel with M20 x 1,5 cable entry (2 entries one plugged) 2 Cast stainless steel with 3/4" NPT cable entry (2 entries one plugged) 5 Deep drawn steel with M20 cable entry (2 entries one plugged) ➀ 4 Deep drawn steel with 1/2"NPT cable entry (2 entries one plugged) ➀ ➀ Only for model 961 9 6 5 0 A 0 complete Code for Echotel 961/962 electronics 7

MODEL IDENTIFICATION 2. Code for Echotel 961/962 transducer BASIC MODEL NUMBER 9 M 1 Echotel 961 transducer with single setpoint 9 M 2 Echotel 962 transducer with dual setpoints TRANSDUCER MATERIALS (use only metal transducers for hazardous area) A 316/316 L (1.4401/1.4404) stainless steel for 961/962 ➀ B Hastelloy C (2.4819) for 961 C Monel (2.4360) for 961 P CPVC for 961/962 R Kynar (PVDF) for 961 S 316/316L (1.4401/1.4404) with 0,5 µm (Ra 20) sanitary finish for 961 ➀ Low temperature sensor (min -80 C) is only available in 316/316L SST for 961 units PROCESS CONNECTION Threaded (Plastic transducers are only available with 3/4" NPT connection) 1 1 threaded 3/4" NPT connection 2 1 threaded 1" NPT connection 2 2 threaded G1 (1" BSP) connection ANSI RF Flanges 2 3 1" 150 lbs Raised face 2 4 1" 300 lbs Raised face 2 5 1" 600 lbs Raised face 3 3 1 1/2" 150 lbs Raised face 3 4 1 1/2" 300 lbs Raised face 3 5 1 1/2" 600 lbs Raised face 4 3 2" 150 lbs Raised face 4 4 2" 300 lbs Raised face 4 5 2" 600 lbs Raised face CPVC flanges for CPVC transducers. Kynar cladded SST flanges for Kynar transducers Use only 150 lbs / PN 16 order codes for plastic transducers EN/DIN Flanges B A DN 25 PN 16 EN 1092-1 Type A B B DN 25 PN 25/40 EN 1092-1 Type A B C DN 25 PN 63/100 EN 1092-1 Type B2 C A DN 40 PN 16 EN 1092-1 Type A C B DN 40 PN 25/40 EN 1092-1 Type A C C DN 40 PN 63/100 EN 1092-1 Type B2 D A DN 50 PN 16 EN 1092-1 Type A D B DN 50 PN 25/40 EN 1092-1 Type A D D DN 50 PN 63 EN 1092-1 Type B2 D E DN 50 PN 100 EN 1092-1 Type B2 Sanitary (use only in combination with sanitary transducer material code S ) 3 T 1" / 1 1 /2" Tri-Clamp 16 AMP fitting 4 T 2" Tri-Clamp 16 AMP fitting V V DN 65 Varivent flange SENSOR TYPE A Standard sensor: min -40 C / max +165 C (-40 F / +325 F) C Low temperature sensor: min -80 C / max +105 C (-110 F / +220 F) only for 961 with 316/316L sensor ACTUATION LENGTH specify in cm (per 0.39") increments Total insertion length = actuation length + 6 mm (0.25") 9M1 transducers 0 0 3 Min 30 mm (1.2") 0 0 4 Min 40 mm (1.5") - for 1" BSP (G1) / flanged and sanitary units 3 3 0 Max 3300 mm (130") 9M2 transducers "A" length, specify "B" length separately 0 1 3 Min 130 mm (5.1") 0 1 5 Min 150 mm (5.9") - for 1" BSP (G1) / flanged units 3 3 0 Max 3300 mm (130") 9 M complete code for Echotel 961/962 transducers 8

DIMENSIONS IN mm (inches) 102 (4) 102 (4) 113 (4.43) without window 123 (4.85) with window 113 (4.43) without window 123 (4.85) with window 46 (1.8) Typical 60 (2.35) Typical Actuation length for BSP (G1) connection Actuation length for NPT connection Actuation length 6 (0.25) Ø 22 (.875) Threaded connection 6 (0.25) Ø 22 (.875) Flanged connection 79 (3.12) 54 (2.12) 102 (4) 58 (2.30) 113 (4.43) without window 123 (4.85) with window 146 (5.75) 26 (1.05) Typical 69 (2.70) Typical Actuation length for Tri-Clamp fitting Actuation length for Varivent fitting 6 (0.25) 6 (0.25) Ø 22 (.875) Tri-Clamp 16 AMP fitting Ø 22 (.875) Flanged connection 102 (4) 102 (4) 113 (4.43) without window 123 (4.85) with window 113 (4.43) without window 123 (4.85) with window 46 (1.8) Typical 60 (2.35) Typical Actuation length A for BSP (G1) connection Actuation length B for BSP (G1) connection Actuation length B for NPT connection Actuation length A for NPT connection Actuation length B min 80 (3) max 3180 (125) Actuation length A 6 (0.25) Ø 22 (.875) Threaded connection 6 (0.25) Ø 22 (.875) Flanged connection 9

SPECIFICATIONS Physical/Functional specifications ➀ Description Input Voltage Power Consumption Signal Output Indication Selftest Housing material Approvals ➀ Automatic Manual SIL (Safety Integrity Level) Electrical data Equivalent data Shock/Vibration Net Weight Specification 2 wire loop powered, 11-35 V DC < 1 Watt Only available with cast aluminium or cast stainless steel housings. 961: 8 ma (safe), 16 ma (alarm) ± 1 ma 962: 8 ma (safe), 12 ma (lower gap alarm), 16 ma (upper gap alarm) ± 1 ma 961/962: 3,6 or 21 ma error signal LED s for process alarm status, malfunction (error of transducer, electronics or electrical noise interference) and wet/dry status of transducer (961 with relay only) Continuously verifies electronics, transducer and noise interference Via pushbutton for checking alarm output(s) and error output/function. IP66, cast aluminium, cast stainless steel or deep drawn 304 stainless steel ATEX, II 1 G, EEx ia IIC T5, intrinsically safe (current shift units with metal transducers) ATEX, II 1/2 G, EEx d IIC T6, explosion proof (units with metal transducers) FM/CSA, non incendive, intrinsically safe and explosion proof Overfill prevention TÜV - WHG 19 / VLAREM II 5.17.7 Functional safety to SIL 2/3 in accordance to IEC 61508 SFF > 90 % full FMEDA report and declaration sheets available upon request Ui = 28,4 V, li = 94 ma, Pi = 0,67 W (ma version) Ci = 10,4 nf (961) / Ci = 60 nf (962), Li = 400 µh (ma version) ANSI/ISA-S71.03 Class SA1 (shock), ANSI/ISA-S71.03 Class VC2 (vibration) 1.5 kg (3 lbs) with 50 mm (2") transducer Performance specifications Description Specification Response time 0,5 s typical Repeatability ± 2 mm (0.078") Ambient Temperature -40 C up to +70 C (-40 F to +160 F) Humidity 0-99 %, non condensing Electromagnetic Compatibility Meets CE requirements (EN 61326) and NAMUR NE 21 Transducers specifications Description Plastic transducers Metal transducers Transducer materials Mounting CPVC Kynar (PVDF) Threaded (NPT) Flanged (ANSI - EN/DIN) 316/316L SST (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) Actuation length From 50 mm up to 3300 mm (2" up to 130") From 30 mm up to 3300 mm (1" up to 130") Max process temp. (consult temp/ press. graphs) -40 C up to 120 C (-40 F up to 250 F) PVDF -40 C up to 80 C (-40 F up to 180 F) CPVC -40 C up to 165 C (-40 F up to 325 F) -80 C up to +105 C (-110 F up to +220 F) 316/316L SST Max pressure (consult temp/ press. graphs) Max viscosity 14 bar @ +40 C (200 psi @ +10 0 F) for NPT threaded units 138 bar (2000 psi): 5 cm transducers except Monel 103 bar (1500 psi): > 5 cm transducers except Monel 83 bar (1200 psi) for Monel transducers Flanged models are downrated to the design pressure of the selected flange 10.000 cp 10

PRESSURE / TEMPERATURE RATINGS Kynar Transducer Ratings Process pressure (bar) 30 25 20 15 10 5 0-40 0 40 80 120 Process temperature ( C) Range with 3/4" NPT Range with 150# flange Range with PN16 flange CPVC Transducer Ratings Process pressure (bar) 30 25 20 15 10 5 0-40 0 40 80 120 Process temperature ( C) Metal Transducer Ratings Process pressure (bar) 160 120 80 40 5 cm transducer > 5 cm transducer 138 bar 103 bar 83 bar 316/316L (1.4404) ➀ Hastelloy c (2.4819) -40 0 40 80 120 165 Process temperature ( C) Monel C ➀ For low temperature sensor: from -80 C up to +105 C 11

IMPORTANT SERVICE POLICY Owners of Magnetrol products may request the return of a control; or, any part of a control for complete rebuilding or replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to the purchaser, (or owner) other than transportation cost if: a. Returned within the warranty period; and, b. The factory inspection finds the cause of the malfunction to be defective material or workmanship. If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour and the parts required to rebuild or replace the equipment. In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of our warranty. No claims for misapplication, labour, direct or consequential damage will be allowed. RETURNED MATERIAL PROCEDURE So that we may efficiently process any materials that are returned, it is essential that a Return Material Authorisation (RMA) form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is available through Magnetrol s local representative or by contacting the factory. Please supply the following information: 1. Purchaser Name 2. Description of Material 3. Serial Number and Ref Number 4. Desired Action 5. Reason for Return 6. Process details Any unit that was used in a process must be properly cleaned in accordance with the proper health and safety standards applicable by the owner, before it is returned to the factory. A material Safety Data Sheet (MSDS) must be attached at the outside of the transport crate or box. All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments. All replacements will be shipped FOB factory. UNDER RESERVE OF MODIFICATIONS BULLETIN N : BE 51-646.3 EFFECTIVE: JUNE 2007 SUPERSEDES: April 2007 www.magnetrol.com BENELUX Heikensstraat 6, 9240 Zele, België Tel. +32 (0)52.45.11.11 Fax. +32 (0)52.45.09.93 E-Mail: info@magnetrol.be DEUTSCHLAND Alte Ziegelei 2-4, D-51491 Overath Tel. 02204 / 9536-0 Fax. 02204 / 9536-53 E-Mail: vertrieb@magnetrol.de FRANCE 40-42, rue Gabriel Péri, 95130 Le Plessis Bouchard Tél. 01.34.44.26.10 Fax. 01.34.44.26.06 E-Mail: magnetrolfrance@magnetrol.fr ITALIA Via Arese 12, I-20159 Milano Tel. (02) 607.22.98 (R.A.) Fax. (02) 668.66.52 E-Mail: mit.gen@magnetrol.it UNITED Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL KINGDOM Tel. (01444) 871313 Fax (01444) 871317 E-Mail: sales@magnetrol.co.uk INDIA C-20 Community Centre, Janakpuri, New Delhi - 110 0058 Tel. 91 (11) 41661840 Fax 91 (11) 41661843 E-Mail: info@magnetrolindia.com