To maximize energy savings in any type of buildings

Similar documents
Luxa. Wide range. Luxa has many options so it is suitable for any type of installation: Emergency light fittings

Beam lights & conversion kits

7 Lighting Technology

Emergency lighting units EM LED Light Engines

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch

MANUFACTURED IN THE UK

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Self Contained Emergency Lighting

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

MANUFACTURED IN THE UK

Exiway Easyled. Emergency lighting

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Compact Sheet-Steel Light Fittings Series 6114/1

19" XL VDI wall mounting cabinets and accessories

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Lens Series / LED Technology

6 Linergy LED+ Industrial IP20 CONTROLS

Twin Spots. Emergency Lighting

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Compact Sheet-Steel Light Fittings Series 6114

Outdoor emergency lighting

Easy and safe installation

T8 Retrofit. LED Tubes

5 Linergy LED. Industrial. Mains lighting IP20

5 Linergy LED. Industrial. Mains lighting IP20

Plexo IP 55 to IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES

SLIM LIGHT SERIES FOR NON MAINTAINED / MAINTAINED LUMINAIRE

CoreLine Recessed the clear choice for LED

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

A fully. Steel is a green totally recyclable material. All products. Steel has come together in the development of a

RUBIX RECESSED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

energy waste Putting a stop to

RADIANCE SUSPENDED RECESSED SURFACE MOUNTED RECESSED (PLASTERBOARD CEILING) Jul. 18

PRODUCT GUIDE MAKING SMART SOLUTIONS SIMPLE

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

ETC310-FS LED

Industrial Linergy LED

innovative and powerful Medical lamps

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING?

Beghelli PRÄZISA. SicuroLED. Decentral Power System

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

ADDRESSABLE SELF TESTING NON MAINTAINED SPOT LIGHT EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED

LIGHTING SPECIFICATIONS

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

EMERGENCY ONE-LED TM UNITY-LED TM LED MAINS/EMERGENCY DRIVER

Sheet Steel Emergency Light Fitting Series 6018

FORMULA. w w w. b e g h e l l i. c o m PROFESSIONAL EMERGENCY LUMINAIRE

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Let yourself be guided by the light

LED Ceiling Mount Luminaires

10 lighting. 2 Work Lights 5 Lamps & Mounting Accessories 5 LED Lamps & Mounting Accessories 9 Work Lamps 10 Incandescent Lamps 12 Bulbs

MLD-44S/g V AC/50-60Hz. MLD-28S/g. MLD-34S/g

7 Lighting Technology

Type Scope of delivery Order unit Order No.

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Specification Sheet for 2D LED Light

RESIDENTIAL BUILDINGS & HOTEL EQUIPMENT

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

LUCERI LUCERI 220 WITH ANTI-DAZZLE CROSS-BLADE LOUVRE LUCERI 150 WITH LENTICULAR THERMOPLASTIC SCREEN

Emergency. Lighting CATALOGUE V. 01. Decentrally and centrally supplied and self contained luminaires

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Self-contained. BX-LED has a simple practical design suitable for general interior or exterior use.

Norwich Hostry Norwich, UK. Downlight Lighting

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Lighting conditions. Always one idea ahead.

LIGHTINGS For Furnitures LED, Halogen & Flourescent

DPX moulded case circuit breakers

Emergency Light Fitting for Fluorescent Lamps Series 6009

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

Battens & special purpose

PIB5 PIB6 PIB7. Pg

Emergency lighting units PC COMBO

Stefano Orlati. LED Lighting

7 Lighting Technology

Central Battery Systems Loadstar AC/DC Systems

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

Light is reliable LED Lamps and Luminaires

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

High quality die cast aluminium with glass diffuser

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

Emergency 830 MAESTRO 1.0

TARO MINI RECESSED LUMINAIRES

CANILO SUSPENDED LUMINAIRES

Laser. New. Laser fixed frame / minimal page 140. Laser fixed frame / minimal page 140. Wide Flood optic. Wide Flood optic. Medium optic.

ETC330-FS LED

CANILO SUSPENDED LUMINAIRES - LED. Pan/tilt range. 3-P-Ad m Deckenbaldachin H11_EN, ceiling canopy H11, recessed plate H12

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

Transcription:

To maximize energy savings in any type of buildings THEY HAVE SPECIFIED AND INSTALLED ENERGY SAVING PRODUCTS: Diamond 2 & 3 Dubai Residence Evelyn Singapore The Soil Marine Bay Singapore Tribeca by the Waterfront Singapore Infrared detector

TRAFFIC DETECTION, AUTOMATIC DETECTOR DIGITAL PASSAGE DETECTION POWER PACKS DETECTION (See p. 909) Automatically switch on or off the light when user is detected (See p. 909) Can be switched on manually or switched off, automatically override with remote control DETECTORS (See p. 909) To complete installation from 47 to 186 m 2 areas POWER PACKS (See p. 909) Where several circuits are required or for large areas Lighting management selection chart (See p. 909) 3 TECHNOLOGIES The choice of your solution depends on the surface of rooms, the walls and how the rooms are used for (passage, long stay...) PASSIVE INFRARED TECHNOLOGY Passive infrared (PIR) technology senses occupancy by detecting the difference between heat emitted from the human body in motion and background space ULTRASONIC TECHNOLOGY Using the Doppler principle, ultrasonic occupancy sensors work by boucing ultrasonic sound waves off objects in an area and measuring the time it takes for the waves to return DUAL TECHNOLOGY A combination that takes advantage of the best features of both PIR and ultrasonic technologies. Using the Dual Sensing Verification Principle, both sensing technologies must detected occupancy to turn lighting on, while continued detection by only one technology will hold lighting on OTHER LEGRAND SYSTEMS AND RANGES FOR YOUR PROJECTS International standards wiring accessories See p. 486-487 Solutions for office equipment See p. 772-773 Solutions for shared work areas See p. 790-791 VDI equipment and emergency lighting systems See p. 866-867 and 914-915 907

select your emergency lighting luminaire Emergency Battery Emergency Cat.Nos Mode IP duration type Lighting source lumen output (in lm) Arcor TM 2 Auto-test Auto-test Addressable 625 40 625 42 M IP 20 1h Ni-Cd Cold cathod 625 41 625 43 NM IP 20 1h Ni-Cd fluorescent tube 45 G5 Standard Auto-test Addressable 617 41 617 70 NM IP 42 1h Ni-Cd 1 x 8 W 210 617 44 617 73 NM IP 42 1h Ni-Cd 1 x 11 W 500 617 36 617 64 C IP 42 1h Ni-Cd 2 x 8 W 200 617 38 617 66 C IP 42 1h Ni-Cd 2 x 8 W 310 617 42 617 71 NM IP 42 3h Ni-Cd 1 x 8 W 155 617 72 NM IP 42 1h Ni-Cd 1 x 8 W 345 617 37 617 65 C IP 42 3h Ni-Cd 2 x 8 W 120 617 30 (1) - NM IP 42 1h Ni-Cd 1 x 8 W 90 617 31 (1) 617 60 (1) NM IP 42 1h Ni-Cd 1 x 8 W 210 617 33 (1) 617 62 (1) NM IP 42 1h Ni-Cd 1 x 8 W 345 617 34 (1) 617 63 (1) NM IP 42 1h Ni-Cd 1 x 11 W 500 617 32 (1) 617 61 (1) NM IP 42 3h Ni-Cd 1 x 8 W 155 617 46 (2) 617 74 (2) C IP 42 1h Ni-Cd 2 x 8 W 235 617 47 (2) 617 75 (2) C IP 42 3h Ni-Cd 2 x 8 W 145 617 76 C IP 42 1h Ni-Cd 2 x 8 W 310 Strio 2 Standard Auto-test Addressable 660 20 660 30 NM IP 41 1h Ni-Cd 1 x 8 W 200 660 21 660 31 M IP 41 1h Ni-Cd 1 x 8 W 170 660 22 660 32 C IP 41 1h Ni-Cd 2 x 8 W 200 660 23 660 33 NM IP 41 3h Ni-Cd 1 x 8 W 130 660 24 660 34 M IP 41 3h Ni-Cd 1 x 8 W 140 660 25 660 35 C IP 41 3h Ni-Cd 2 x 8 W 130 S8 Standard 660 00 NM IP 42 1h Ni-Cd 1 x 8 W 140 660 01 M IP 42 1h Ni-Cd 1 x 8 W 140 660 02 C IP 42 1h Ni-Cd 2 x 8 W 140 660 03 NM IP 42 3h Ni-Cd 1 x 8 W 110 660 04 M IP 42 3h Ni-Cd 1 x 8 W 110 660 05 C IP 42 3h Ni-Cd 2 x 8 W 110 L31 Standard Auto-test Addressable 6610 02 NM IP 42 1h Ni-Mh 1 x 6 W 100 6610 05 6610 21 NM IP 42 1h Ni-Mh 2 x 6 W 250 6610 06 6610 22 NM IP 42 2h Ni-Mh 1 x 6 W 160 6610 07 NM IP 42 1h Ni-Mh 2 x 6 W 315 6610 00 NM IP 42 1h Ni-Cd 1 x 6 W 70 6610 01 6610 19 NM IP 42 1h Ni-Cd 1 x 6 W 100 6610 03 NM IP 42 1h Ni-Cd 1 x 6 W 160 6610 04 6610 20 NM IP 42 1h Ni-Cd 1 x 6 W 200 6610 08 6610 24 C IP 42 1h Ni-Cd 2 x 6 W 200 6610 09 6610 23 C IP 42 2h Ni-Cd 2 x 6 W 110 6610 10 NM IP 42 3h Ni-Cd 1 x 6 W 75 6610 30 (3) NM IP 42 1h Ni-Cd 1 x 6 W 100 6610 31 (3) 6610 33 (3) NM IP 42 1h Ni-Cd 2 x 6 W 200 6610 32 (3) NM IP 42 3h Ni-Cd 1 x 6 W 75 U21 Standard 617 10 NM IP 42 1h Ni-Cd 1 x 6 W 45 617 02 NM IP 42 1h Ni-Cd 1 x 6 W 100 617 07 NM IP 42 1h Ni-Cd 1 x 6 W 300 617 08 C IP 42 1h Ni-Cd 2 x 6 W 85 617 11 NM IP 42 3h Ni-Cd 1 x 6 W 120 5108 Standard B65 / NT65 Twin spot light 6432 50 M IP 20 1h Ni-Cd 1 x 8 W 70/190 6432 52 M IP 20 3h Ni-Cd 1 x 8 W 30/50 Standard Auto-test Addressable 615 61 - NM IP 65 1h Ni-Cd 1 x 6 W 90 615 62 615 67 NM IP 65 1h Ni-Cd 1 x 6 W 165 615 66 - C IP 65 1h Ni-Cd 2 x 6 W 155 618 34 - C IP 65 1h Ni-Cd 2 x 8 W 435-618 35 NM IP 65 1h Ni-Cd 1 x 11 W 715 639 92 NM IP 20 1h Ni-Cd 2 x 20 W 2 x 400 639 93 NM IP 20 3h Ni-Cd 2 x 20 W 2 x 400 6608 42 NM IP 55 1h Ni-Cd 2 x 35 W 900 6608 43 NM IP 45 1h Ni-Cd 2 x 65 W 1500 NM: Non Maintained C: Combined M:Maintained P: Permanent (1) With two signalling LEDs (2) Double sided for suspension or flag mounting (3) 100-240 V power supply 916 Red catalogue numbers: New products

Legrand Vision System (L.V.S.) central control panel for addressable emergency lighting units and conversion kits Legrand Vision System (L.V.S.) monitoring software 625 15 625 12 625 13 Pack Cat.Nos Central control panel unit for addressable emergency lighting luminaires and conversion kits 1 625 15 Periodically centralises the state of the emergency lighting luminaires and conversion kits Communication between the addressable luminaires and the central control panel is carried out via the remote control line Capacity: Direct connection of 250 addressable products to the central control panel (star configuration or series connection). The longest line is limited to 700 m Extension via repeater Cat.No 625 12 for more than 250 addressable luminaires or a line longer than 700 m Maximum capacity of the central control panel: 1,023 addressable luminaires or conversion kits Use: Via clear ergonomic menu and contextual keys with display on large LCD screen - Configuration of the parameters of the central control panel - Simple addressing of addressable luminaires - Management of user access rights - Maintenance assistance functions with location of faulty luminaires - Function on front panel of the central control luminaires to directly switch lighting units to rest mode - Permanent backup memory of the configuration of the addressable luminaires installation Signalling: - Central control panel operational - Faulty emergency lighting luminaires Connections: - 19-pin adaptable RS 232 output for connection to PC, modem, or connection interface Possible types of connection: - Via RS 232 serial cord ( 5 m) - Via RS 485 seria link (via RS 232/RS 485 interface, not supplied) - Via Ethernet local area network (via RS 232/IP interfaces, not supplied) - 125-pin SUB-D output for printer port Power supply: 230 V - 50 Hz Ni-Cd battery 8.4 V - 0.15 Ah Class II IP 20 Repeater 1 625 12 For extending the installation beyond 250 units or for a line 700 m (on central control panel or repeater) up to 250 additional luminaires and on the longest line 700 m Class II Power supply: 230 V - 50 Hz Ni-Cd battery 8.4 V - 0.15 Ah Dim.: 6 x 17.5 mm modules L.V.S. software main screen Spare part list Overview Work sheet Pack Cat.Nos Monitoring software 1 625 13 For supervising an installation of addressable self-contained emergency lighting luminaires and conversion kits in one complete site equipped with one or more control panels, irrespective of the size of the installation Simultaneous supervision of the whole site according to the construction configuration (tree structure by buildings, levels, floors or zones) Display of the actual image on each luminaire shown on the background of each zone of the site Backgrounds of the site imported in DXF Autocad format (vectorised) or bitmap (GIF, etc) Direct display of faulty units on plan, with type of luminaire failure New functions for assistance with maintenance - Overview screen of the establishment showing the number and percentage of faulty luminaires for each building and level of the site (in relation to the number of luminaires installed) - Automatic printout of the list of spare parts (descriptions and Legrand catalogue numbers) needed to repair the whole installation - Automatic printout of a repair document locating each faulty luminaire and detailing its repair operations These products are part of emergency lighting systems > See p. 914-915 917

EMERGENCY LIGHTING >>> Arcor TM 2 Style and safety Arcor TM 2 Self-contained emergency edge lighting luminaires 625 40 625 40 flush-mounting + 625 83 625 80 625 40 + 625 80 + 625 82 Direct flush-mounting Wall or flag mounting Unit for direct flush-mounting in ceiling or false ceiling Transparent plate for improved light reproduction Life time duration > 50 000 hours: cold cathode technology Aluminium or white finish These products are part of emergency lighting systems > See p. 914-915 Pack Cat.Nos Self-contained emergency edge lighting luminaires Equipped with long-life cold cathode fluorescent tube ( 50,000 hours) Certified IEC 60598-2-22 and EN 60598-2-22 standards Lumen output: 45 lumens Duration: 1 hour Power supply 230 V - 50/60 Hz IP 20 - class II Autotest luminaires incorporate an automatic self-testing system: - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests Autotest and addressable luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat.No 625 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Unit for direct flush-mounting: - on self-supporting ceilings using quick-fit fixing claws - on false ceilings using holding claws and fastening system for safety tie or by 1/4 -turn for threaded rod Shallow depth (80 mm) Option of mounting as wall strip or flag with fixing kit Cat.No 625 80/625 81 Auto-test addressable Auto-test 1 625 42 625 40 Maintained 1 625 43 625 41 Non-maintained Equipped with long life LED standby indicator ( 100,000 hours) Fixing kit for mounting as wall strip or flag Kit comprising: - 1 mounting bracket - 1 casing 1 625 80 Aluminium finish 1 625 81 White finish 918

Arcor TM 2 pictogram plates Arcor TM 2 Self-contained emergency edge lighting luminaires Overall dimensions Standard flush-mounting 79 55 324 mm 300 270 625 82 625 83 19.5 92 5 159.7 280 Wall mounting with fixing kit Flag mounting 364 mm 323.2 103 93 79 625 88 625 86 Pack Cat.Nos Pictogram plates Polycarbonate plates directly moulded with the pictogram (In-Mold technology) ensuring improved luminous performances and protection against scratches Complying with ISO 3864-1 and ISO 7010 standards For emergency lighting 332.7 323.2 1 625 82 Exit to left or right 79 90 252.2 133.5 88.4 1 625 83 Exit below 92.7 21.2 252.2 1 625 88 Exit For fire-fighting equipment 1 625 86 Extinguisher Flush-mounting 1 625 87 Fire hose point Flag mounting Wall strip mounting These products are part of emergency lighting systems > See p. 914-915 919

G5 self-contained emergency lighting luminaires 617 62 617 71 617 47 + 617 91 + 6608 65 Pack Cat.Nos Non-maintained luminaires Slim luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10% - 50/60 Hz IP 42 - IK 07 class II Suitable for mounting on inflammable surfaces Ni-Cd batteries, high temperature type Recharge time: 24 hours High capacity screw terminals: 2 x 2.5 mm 2 (mains) Charge monitor: 2 high luminosity amber LEDs or 1 green LED Autotest and addressable luminaires incorporate an automatic self-testing system: - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests These autotest luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central conrol panel (Cat. No 625 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Standard Auto-test 8 W luminaires with 2 high luminosity Addressable amber LEDs 1 617 30-1 h - 90 lm 1 617 31 617 60 1 h - 210 lm 1 617 33 617 62 1 h - 345 lm 1 617 32 617 61 3 h - 155 lm 11 W luminaires with 2 high luminosity amber LEDs 1 617 34 617 63 1 h - 500 lm 8 W luminaires with a green LED 1 617 41 617 70 1 h - 210 lm 1 617 42 617 71 3 h - 155 lm 1-617 72 1 h - 345 lm 11 W luminaires with a green LED 1 617 44 617 73 1 h - 500 lm Pack Cat.Nos Combined luminaires Possibility to turn on and off the maintained tube with an external switch (see the technical leaflet) Standard Auto-test 8 W luminaires with a green LED Addressable 1 617 36 617 64 1 h - 200 lm 1 617 38 617 66 1 h - 310 lm 1 617 37 617 65 3 h - 120 lm 8 W double-sided luminaires for suspension or flag mounting 1 617 46 617 74 1 h - 235 lm 1 617 47 617 75 3 h - 145 lm 1 617 76 3 h - 310 lm Suspension kit 1 617 91 To install the luminaires Cat.Nos 617 46/47/74/75/76 at 40 cm from the ceiling Chromed colour and metallic accessory Flag kit 1 617 92 To install the luminaires Cat.Nos 617 46/47/74/75/76 in flag mounting position Chromed colour and metallic accessory These products are part of emergency lighting systems > See p. 914-915 920

G5 self-contained emergency lighting luminaires 617 30 + 617 82 + 6608 67 617 46 + 617 92 + 6608 75 Pack Cat.Nos Accessories Double-sided diffuser 1 617 82 To replace the one delivered with the luminaire Semi-flush mounting frame To install the luminaire in wall or false ceiling, depth: 52 mm 1 617 83 White 1 617 84 Steel Pack Cat.Nos Labels 5 6608 65 310 x 112 mm 5 6608 66 310 x 112 mm 5 6608 67 310 x 112 mm 5 6608 68 310 x 112 mm 1 617 85 Aluminium 1 617 86 Bronze Flush-mounting frame To install the luminaire in wall or false ceiling, depth: 64 mm 1 617 87 White 1 617 88 Steel 1 617 89 Aluminium 5 6608 64 310 x 112 mm 5 6608 69 310 x 112 mm 5 6608 74 310 x 112 mm 5 6608 75 310 x 112 mm 5 6608 76 310 x 112 mm Other signs, please consult us 1 617 90 Bronze These products are part of emergency lighting systems > See p. 914-915 921

G5xxxxxx self-contained emergency lighting luminaires Dimensions (in mm) Optical data Surface mounting Flush-mounting Luminaire spacing, in metres, to provide 1 lux minimum illuminance 365 150 Semi flush-mounting 128 59 Double-sided mounting 180 52 344 365 365 Suspension mounting 582 365 85 150 Lamps and batteries Cat.Nos Emergency lamps Batteries 617 30 609 41 618 92 617 31/60 609 41 618 84 617 32/61 609 41 617 99 617 33/62 609 41 618 86 617 34/63 607 53 617 99 617 36/64 609 41 618 84 617 37/65 609 41 617 99 617 38/66 609 41 618 86 617 41/70 609 41 618 84 617 42/71 609 41 617 99 617 44/72/73 607 53 617 99 617 46/74 609 41 618 84 617 47/75 609 41 617 99 617 76 609 41 618 86 39 128 158 64 374 27 398 180 Semi flush-mounting with colored frame 214 52 85 344 411 Flag mounting 462 150 39 Celling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height directly D (m) (m) under D (m) D (m) D (m) luminaire (lux) 617 30 2.5 5.0 2.7 7.0 7.0 2.7 3.0 3.5 2.7 7.4 7.4 2.7 4.0 2.0 2.0 7.6 7.6 2.5 5.0 1.3 1.7 7.4 7.4 1.7 617 31/41/60/70 2.5 11.6 3.7 9.2 9.2 3.7 3.0 8.0 3.9 10.0 10.0 3.9 4.0 4.5 4.1 10.8 10.8 4.1 5.0 2.9 4.1 10.3 10.3 4.1 6.0 2.0 3.8 11.6 11.6 3.8 617 32/42/61/71 2.5 8.9 3.4 8.6 8.6 3.4 3.0 6.2 3.5 9.0 9.0 3.5 4.0 3.5 3.6 9.8 9.8 3.6 5.0 2.2 3.4 10.2 10.2 3.4 6.0 1.5 2.8 10.2 10.2 2.8 617 33/62/72 2.5 19.1 4.4 10.6 10.6 4.4 3.0 13.3 4.7 11.6 11.6 4.7 4.0 7.5 5.0 12.8 12.8 5.0 5.0 4.8 5.2 13.8 13.8 5.2 6.0 3.3 5.2 14.4 14.4 5.2 617 34/44/63/73 2.5 29.0 4.9 12.0 12.0 4.9 3.0 20.0 5.3 13.0 13.0 5.3 4.0 11.3 5.9 14.6 14.6 5.9 5.0 7.3 6.2 16.0 16.0 6.2 6.0 5.0 6.4 16.8 16.8 6.4 617 36/64 2.5 11.2 3.6 9.2 9.2 3.6 3.0 7.8 3.8 9.8 9.8 3.8 4.0 4.4 4.0 10.6 10.6 4.0 5.0 2.8 4.0 11.2 11.2 4.0 6.0 2.0 3.6 11.4 11.4 3.6 617 37/65 2.5 7.8 3.2 8.2 8.2 3.2 3.0 5.5 3.3 8.6 8.6 3.3 4.0 3.0 3.3 9.4 9.4 3.3 5.0 2.0 3.0 9.5 9.5 3.0 6.0 1.3 2.4 9.4 9.4 2.4 617 38/66 2.5 17.4 4.3 10.4 10.4 4.3 3.0 12.1 4.5 11.2 11.2 4.5 4.0 6.8 4.9 12.4 12.4 4.9 5.0 4.3 5.0 13.4 13.4 5.0 6.0 3.0 5.0 14.0 14.0 5.0 617 46/74 2.5 6.2 3.0 7.6 7.6 3.0 3.0 4.3 3.0 8.0 8.2 3.0 4.0 2.4 2.9 8.4 8.6 3.0 5.0 1.5 2.4 8.4 8.6 2.5 6.0 1.0 1.2 8.0 8.2 1.3 617 47/75 2.5 3.9 2.4 6.4 6.6 2.5 3.0 2.7 2.3 6.6 6.8 2.4 4.0 1.5 1.9 6.8 6.8 2.0 5.0 1.0-6.2 6.4-617 76: consult us 922

Distribution of luminous intensity in cd/1 000 lm Cat.No 617 30 Cat.Nos 617 31/41/60/70 Cat.Nos 617 32/42/61/71 30 cd 75 cd 50 cd Cat.Nos 617 33/62/72 Cat.Nos 617 34/44/63/73 Cat.Nos 617 36/64 125 cd 175 cd 75 cd Cat.Nos 617 37/65 Cat.Nos 617 38/66 50 cd 100 cd Cat.Nos 617 46/74 Cat.Nos 617 47/75 Cat.No 617 76-150 +180 +150-150 +180 +150-150 +180 +150-120 +120-120 +120-120 +120 40 cd 40 cd 60 cd 923

Strio 2 self-contained emergency lighting luminaires Strio 2 self-contained emergency lighting luminaires Dimensions (in mm) Surface mounting 387 81 660 30 660 22 167 387 81 167 Plug-in base plate 129.5 80 33 660 24 74 58 115.6 Pack Cat.Nos 8 W non-maintained, maintained and combined luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10% - 50-60 Hz IP 41 - Class II Plug-in base plate to ease installation and maintenance Lamp and emergency operation with a push-button Suitable for mounting on inflammable surface Ni-Cd batteries, high temperature type Recharge time: 24 hours High capacity screw terminals: 2 x 2.5 mm 2 Charge monitor with a green LED Autotest and adressable luminaires incorporate an automatic self-testing system: - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests These autotest luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat. No 625 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Standard Auto-test 1 h duration addressable 1 660 20 660 30 Non-maintained 200 Im 1 660 21 660 31 Maintained 170 Im 1 660 22 660 32 Combined 200 Im 3 h duration 1 660 23 660 33 Non-maintained 130 Im 1 660 24 660 34 Maintained 140 Im 1 660 25 660 35 Combined 130 Im 79 80 Ceiling mounting with double-sided diffuser 387 167 297 Flush-mounting 231 20 469 190 Flush-mounting with double-sided diffuser 469 Grid Cat.No 609 06 442 58 190 57 58 207 Accessories 152 1 660 91 Flush-mounting frame 1 660 93 Double-sided diffuser 1 609 06 Grid 451 474 185 Labels (p. 949) 924

Optical data Luminaire spacing, in metres, to provide 1 lux minimum illuminance Ceiling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height directly D (m) (m) under D (m) D (m) D (m) luminaire (lux) 660 20/30 2.5 7.5 3.2 8.2 10.4 3.95 3 5.2 3.3 8.8 10.8 4 4 2.9 3.3 9.4 11.3 3.9 5 1.9 3 9.6 11.4 3.5 6 1.3 2.25 9.4 10.8 2.55 660 21/31 2.5 6.5 3.1 7.8 9.8 3.7 3 4.5 3.15 8.4 10.2 3.75 4 2.6 3.1 8.8 10.6 3.6 5 1.6 2.6 8.8 10.4 3 6 1.1 1.6 8.4 10 1.7 660 22/32 2.5 7.9 3.1/3.3 7.8/8.4 9.4/10.8 3.7/4.2 3 5.5 3.3/3.4 8.4/9 10/11.4 3.8/4.3 4 3.1 3.3/3.5 9/9.6 10.8/12.2 3.8/4.3 5 2.0 3/3.2 9.4/10 10.8/12.2 3.4/3.9 6 1.4 2.4/2.5 9.2/9.8 10.4/11.8 2.6/3.1 660 23/33/24/34 2.5 5.0 2.7 7.2 9 3.3 3 3.7 2.8 7.6 9.2 3.2 4 2.0 2.6 7.8 9.2 2.9 5 1.3 1.8 7.6 9 2 6 0.9 / 6.8 8 / 660 25/35 2.5 5.4 2.7/2.8 7/7.4 8.2/9.4 3.1/3.5 3 3.7 2.7/2.9 7.4/7.8 8.6/9.8 3.1/3.5 4 2.1 2.5/2.7 7.6/8.2 8.8/10 2.8/3.3 5 1.3 1.9/2 7.4/8 8.6/9.8 2/2.5 6 0.9 / 6.8/7.2 7.8/8.8 / Distribution of luminous intensity in cd/1 000 Im Cat.Nos 660 20/21/23/24/30/31/33/34 (cd/1000 lm) -105-120 -135-165 +150 +120 +105-75 -45 50 100 150 200 250 300-30 -15 0 +15 +30 C0 - C180 C90 - C270 Cat.Nos 660 22/25/32/35-75 -45 +75 +45 (cd/1000 lm) -120-135 -150-165 +135 +120 +105 50 100 150 200 250 300-30 -15 0 +15 +30 C0 - C180 C90 - C270 +75 +45 Lamps and batteries Cat.Nos Emergency lamps Batteries 660 20/30 609 41 660 98 660 21/31 609 41 660 98 660 22/32 609 41 660 98 660 23/33 609 41 660 99 660 24/34 609 41 660 99 660 25/35 609 41 660 99 925

S8 self-contained emergency lighting luminaires S8 self-contained emergency lighting luminaires Dimensions (in mm) Surface mounting 58 124 330 660 00 Ceiling mounting with double-sided diffuser 124 330 660 01 + 6608 66 175 20 280 660 03 + 660 90 Flush-mounting 372 166 45 660 01 + 660 90 + 660 92 + 610 01 Pack Cat.Nos 8 W non-maintained, maintained and combined luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10 % - 50/60 Hz IP 42 - Class II Lamp and emergency operation test with a pushbutton Suitable for mounting on inflammable surfaces Ni-Cd batteries, high temperature type Recharge time: 24 hours High capacity screw terminals: 2 x 2.5 mm 2 Charge monitor with a green LED 1 h duration - 140 lm 1 660 00 Non-maintained 1 660 01 Maintained 1 660 02 Combined 3 h duration - 110 lm 1 660 03 Non-maintained 1 660 04 Maintained 1 660 05 Combined Accessories 1 660 90 Flush-mounting frame 1 660 92 Double-sided diffuser 32 With double-sided diffuser 149 Lamps and batteries Cat.Nos 45 Emergency lamps Batteries 660 00/01/02 609 41 618 83 660 03/04/05 609 41 618 85 Labels (p. 949) 926

Optical data Distribution of luminous intensity in cd/1000 lm Luminaire spacing, in metres, to provide 1 lux minimum illuminance Ceiling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height (m) directly under D (m) D (m) D (m) D (m) luminaire (lux) 660 00 2.5 6.2 3 3.8 4.3 3.3 3 4.3 3 4 4.5 3.4 3.5 3.2 3 4.2 4.7 3.3 4 2.4 2.9 4.3 4.8 3.2 4.5 1.9 2.7 4.3 4.8 3.2 5 1.5 2.5 4.3 4.7 2.7 5.5 1.3 2 4.2 4.6 2.2 6 1.1 1.2 4 4.4 1.3 660 01 2.5 6.2 3 3.8 4.3 3.3 3 4.3 3 4 4.5 3.4 3.5 3.2 3 4.2 4.7 3.3 4 2.4 2.9 4.3 4.8 3.2 4.5 1.9 2.7 4.3 4.8 3 5 1.5 2.5 4.3 4.7 2.7 5.5 1.3 2 4.2 4.6 2.2 6 1.1 1.2 4 4.4 1.3 660 02 2.5 6.7 3 3.8 4/4.5 3.2/3.5 3 4.6 3.1 4.1 4.3/4.7 3.3/3.6 3.5 3.4 3.1 4.2 4.4/4.9 3.3/3.5 4 2.6 3 4.4 4.6/5 3.2/3.4 4.5 2 2.9 4.4 4.7/5.1 3.1/3.3 5 1.7 2.6 4.4 4.7/5 2.8/2.9 5.5 1.4 2.3 4.3 4.6/4.9 2.4/2.5 6 1.1 1.6 4.2 4.5/4.8 1.8/1 660 03 2.5 4.9 2.7 3.5 4 3 3 3.4 2.7 3.7 4.2 3 3.5 2.5 2.6 3.8 4.2 2.9 4 1.9 2.4 3.8 4.2 2.7 4.5 1.5 2.1 3.8 4.2 2.3 5 1.2 1.6 3.7 4.1 1.7 5.5 1 0.5 3.5 3.8 0.5 660 04 2.5 4.9 2.7 3.5 3.9 3 3 3.4 2.7 3.7 4.1 3 3.5 2.5 2.6 3.7 4.2 2.9 4 1.9 2.4 3.8 4.2 2.6 4.5 1.5 2.1 3.7 4.2 2.3 5 1.2 1.6 3.6 4 1.7 5.5 1 0.3 3.5 3.8 0.4 660 05 2.5 5.2 2.7 3.5 3.7/4.1 2.9/3.1 3 3.6 2.7 3.7 3.9/4.4 2.9/3.2 3.5 2.7 2.7 3.8 4.1/4.5 2.9/3 4 2 2.5 3.9 4.2/4.5 2.7/2.9 4.5 1.6 2.3 3.9 4.1/4.5 2.5/2.6 5 1.3 1.8 3.8 4.1/4.3 2/2.1 5.5 1.1 1.1 3.7 3.9/4.1 1.1/1.2 Cat.No 660 00 Cat.No 660 01 50 cd 50 cd Cat.No 660 02 Cat.No 660 03 25 cd Cat.No 660 04 Cat.No 660 05 50 cd 30 cd 30 cd 927

L31 LUMINAIRES >>> One universal base for 3 different shapes L31 environmental friendly self-contained emergency lighting luminaires 6610 02 Pack Cat.Nos 6 W non-maintained environmental friendly extra slim luminaires Low depth: 43 mm Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10% - 50/60 Hz Low consumption with switching power supply incorporated IP 42 - IK 07 Class II Suitable for mounting on inflammable surfaces Ni-MH environment friendly batteries, high temperature type Recharge time: 24 hours Screw terminals capacity: 2 x 1.5 mm 2 Charge monitor with a green LED Autotest and addressable products incorporate an automatic self-testing system - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests These autotest luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat. No 625 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Standard Autotest Addressable 1 6610 02 1 h - 100 lm (1 x 6 W) 1 6610 05 6610 21 1 h - 250 lm (2 x 6 W) 1 6610 06 6610 22 2 h - 160 lm (1 x 6 W) 1 6610 07 1 h - 315 lm (2 x 6 W) Large choice of aesthetic diffusers Extra-slim: 43 mm depth Easy to integrate in walls and ceilings Energy saving thanks to green batteries Non-maintained and combined luminaires These products are part of emergency lighting systems > See p. 914-915 928

L31 self-contained emergency lighting luminaires 6610 00 6610 08 + 6610 40 6610 00 + 6610 43 6610 41 6610 40 Pack Cat.Nos 6 W extra slim luminaires Low depth: 43 mm Certified to IEC 60598-2-22 and EN 60598-2-22 standards Low consumption with switching power supply incorporated IP 42 - IK 07 Class II Suitable for mounting on inflammable surfaces Ni-Cd batteries, high temperature type Recharge time: 24 hours Screw terminals capacity: 1 x 1.5 mm 2 Charge monitor with a green LED Autotest and addressable products incorporate an automatic self-testing system - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests These autotest luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat. No 625 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Standard Autotest Power supply: 230 V +/- 10% - 50/60 Hz Addressable 1 6610 00 1 h - 70 lm non-maintained (1 x 6 W) 1 6610 01 6610 19 1 h - 100 lm non-maintained (1 x 6 W) 1 6610 03 1 h - 160 lm non-maintained (1 x 6 W) 1 6610 04 6610 20 1 h - 200 lm non-maintained (1 x 6 W) 1 6610 08 6610 24 1 h - 200 lm combined (2 x 6 W) 1 6610 09 6610 23 2 h - 110 lm combined (2 x 6 W) 1 6610 10 3 h - 75 lm non-maintained (1 x 6 W) Power supply: from 100-240 V - 50/60 Hz 1 6610 30 1 h - 100 lm non-maintained (1 x 6 W) 1 6610 31 6610 33 1 h - 200 lm non-maintained (1 x 6 W) 1 6610 32 3 h - 75 lm non-maintained (1 x 6 W) Pack Cat.Nos Accessories 1 6610 40 Universal flush- mounting frame for walls and ceilings Include 2 pieces: box + frame 1 6610 42 Flush-mounting frame for mounting over C3 box 1 6610 41 For access with tubes 20 mm 1 6610 43 Pictogramm plate for transformations in a double side unit 1 6610 44 Square diffuser 1 6610 45 Round diffuser 1 6610 46 Round flush-mounting frame 1 6610 47 Square flush-mounting frame These products are part of emergency lighting systems > See p. 914-915 Red catalogue numbers: New products 929

L31 Self-contained emergency lighting luminaires Dimensions (in mm) Flush-mounting over C3 box Universal surface mounting 130 161 280 43 330 14 With pictogramm plate With round diffuser 285 280 43 Flush-mounting with round diffuser 290 6 to 35 150 Ø 310 28 Mounting with tubes 20 mm 140 130 186 152 With square diffuser 280 280 43 Flush-mounting with square diffuser 290 310 150 6 to 35 325 28 280 290 35 50 Universal flush-mounting Lamps and batteries 164 301 325 6 to 35 142 42 9 Cat.Nos Emergency lamps Batteries 6610 00 607 51 618 92 6610 01/19/30 607 51 618 83 6610 02 607 51 6608 35 6610 03 607 51 618 84 6610 04/20/31/33 607 51 618 85 6610 05/21 607 51 6608 36 6610 06/22 607 51 6608 37 6610 07 607 51 6608 37 6610 08/24 607 51 618 85 6610 09/23 607 51 618 85 6610 10/32 607 51 618 85 930

Distribution of luminous intensity in cd/1 000 lm Cat.No 6610 00 Cat.Nos 6610 01/02/19/30 Cat.No 6610 03 25 cd 35 cd 50 cd Cat.Nos 6610 04/20/31/33 Cat.Nos 6610 05/21 Cat.Nos 6610 06/22 75 cd 75 cd 50 cd Cat.No 6610 07 Cat.Nos 6610 08/24 Cat.Nos 6610 09/23 100 cd 75 cd 35 cd Cat.Nos 6610 10/32 25 cd 931

L31 xxxxxx Self-contained emergency lighting luminaires Ceiling mounting height (m) Lighting level directly under luminaire (lux) Axial to wall Axial spacing Transverse spacing Transverse to wall D (m) D (m) D (m) D (m) 6610 00: 70 lm 2.5 3.5 2.3 6.2 6.2 2.3 3 2.5 2.2 6.4 6.4 2.2 3.5 1.8 2 6.4 6.4 2 4 1.4 1.6 6.4 6.4 1.6 4.5 1.1 1 6 6 1 5 0.9 / 5.6 5.6 / 5.5 0.7 / 5 5 / 6 0.6 / 4 4 / 6610 01/02/19/30: 100 lm 2.5 5 2.7 7.2 7.2 2.7 3 3.5 2.7 7.6 7.6 2.8 3.5 2.6 2.7 7.6 7.8 2.7 4 2 2.5 7.8 7.8 2.5 4.5 1.6 2.2 7.8 7.8 2.2 5 1.3 1.7 7.6 7.6 1.8 5.5 1.1 0.8 7.2 7.2 0.8 6 0.9 / 6.8 6.8 / 6610 03: 160 lm 2.5 7.5 3.2 8.2 8.2 3.2 3 5.2 3.3 8.8 8.8 3.3 3.5 3.9 3.3 9 9.2 3.4 4 3 3.3 9.2 9.4 3.3 4.5 2.3 3.2 9.4 9.4 3.2 5 1.9 3 9.4 9.6 3 5.5 1.6 2.7 9.4 9.4 2.7 6 1.3 2.2 9.2 9.2 2.3 6610 04/20/31/33: 200 lm 2.5 9.3 3.5 8.8 8.8 3.5 3 6.5 3.6 9.4 9.4 3.6 3.5 4.8 3.7 9.8 9.8 3.7 4 3.6 3.7 10.2 10.2 3.7 4.5 2.9 3.7 10.4 10.4 3.7 5 2.3 3.5 10.4 10.6 3.6 5.5 1.9 3.4 10.4 10.6 3.4 6 1.6 3.1 10.6 10.6 3.1 6610 05/21: 250 lm 2.5 11.3 3.7 9.2 9.4 3.7 3 7.8 3.9 10 10 3.9 3.5 5.7 4 10.4 10.4 4 4 4.4 4.1 11 11 4.1 4.5 3.5 4 11.2 11.2 4.1 5 2.8 4 11.2 11.4 4 5.5 2.3 3.9 11.6 11.6 3.9 6 2 3.7 11.6 11.6 3.7 932

L31 xxxxxx Self-contained emergency lighting luminaires (continued) Ceiling mounting height (m) Lighting level directly under luminaire (lux) Axial to wall Axial spacing Transverse spacing Transverse to wall D (m) D (m) D (m) D (m) 6610 06/22: 160 lm - 2 h 2.5 7.5 3.2 8.2 8.2 3.2 3 5.2 3.3 8.6 8.8 3.3 3.5 3.8 3.3 9 9 3.3 4 2.9 3.3 9.4 9.4 3.3 4.5 2.3 3.2 9.4 9.4 3.2 5 1.9 3 9.4 9.4 3 5.5 1.5 2.7 9.4 9.4 2.7 6 1.3 2.2 9.2 9.2 2.2 6610 07: 315 lm 2.5 14.2 4 10 10 4 3 9.9 4.3 10.6 10.8 4.3 3.5 7.2 4.4 11.2 11.4 4.4 4 5.5 4.5 11.8 11.8 4.5 4.5 4.4 4.6 12.2 12.4 4.6 5 3.6 4.5 12.4 12.6 4.6 5.5 2.9 4.5 12.8 12.8 4.5 6 2.5 4.4 13 13 4.4 6610 08/24: 200 lm - Combined 2.5 8.8 3.4 8.6 8.6 3.3 3 6.1 3.5 9.2 9 3.5 3.5 4.5 3.6 9.6 9.4 3.6 4 3.4 3.6 10 9.8 3.6 4.5 2.7 3.5 10 10 3.5 5 2.2 3.4 10.2 10 3.4 5.5 1.8 3.2 10.2 10 3.1 6 1.5 2.9 10.2 10 2.8 6610 09/23: 110 lm - 2 h 2.5 5.2 2.7 7.2 7.2 2.7 3 3.6 2.7 7.6 7.4 2.7 3.5 2.6 2.7 7.8 7.6 2.7 4 2 2.5 7.8 7.6 2.5 4.5 1.6 2.2 7.8 7.6 2.2 5 1.3 1.8 7.6 7.6 1.8 5.5 1.1 1 7.4 7.2 0.9 6 0.9 / 6.8 6.8 / 6610 10/32: 75 lm - 3 h 2.5 3.5 2.3 6.2 6.2 2.3 3 2.4 2.2 6.4 6.4 2.2 3.5 1.8 2 6.4 6.4 2 4 1.4 1.6 6.4 6.4 1.6 4.5 1.1 0.9 6 6 0.9 5 0.9 / 5.6 5.6 / 5.5 0.7 / 5 5 / 6 0.6 / 3.8 3.8 / 933

U21 self-contained emergency lighting luminaires 617 02 617 08 + 617 20 617 02 + 617 20 617 02 + 617 20 + 617 21 Pack Cat.Nos 6 W luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10% - 50/60 Hz IP 42 - IK 07 Class II Suitable for mounting on inflammable surfaces Ni-Cd batteries, high temperature type Recharge time: 24 hours Screw terminals capacity: 2 x 1.5 mm 2 Charge monitor: 2 high luminosity amber LEDs (non maintained units), 1 red LED (Cat.No 617 11) or 1 green LED (combined units) 6 W fluorescent-non maintained 10 617 10 1 h - 45 lm 1 617 02 1 h - 100 lm 1 617 07 1 h - 310 lm 1 617 11 3 h - 120 lm 6 W fluorescent-combined 1 617 08 1 h - 85 Im Pack Cat.Nos Accessories 10 617 20 Flush-mounting frame 10 617 21 Box for mounting on walls joint to frame Cat.No 617 20 Labels (p.949) These products are part of emergency lighting systems > See p. 914-915 934

U21 self-contained emergency lighting luminaires Dimensions (in mm) Surface mounting 110 245 58 Recessed mounting 260 283 148 116 11 Recessed mounting in walls Optical data Luminaire spacing, in metres, to provide 1 lux minimum illuminance Ceiling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height (m) directly under D (m) D (m) D (m) D (m) luminaire (lux) 617 10 2.5 1.68 1.3 2.13 2.57 1.5 3 1.17 0.82 2.06 2.41 0.92 3.5 0.86-1.85 2.14-4 0.66-1.46 1.67-4.5 0.52-0.46 0.64-5 0.42 - - - - 617 02 2.5 4.9 2.5 6.6 8.1 2.9 3 3.6 2.4 6.8 8.2 2.8 4 2.0 1.9 6.8 8.0 2.2 5 1.2 0.5 6.2 7.2 0.5 617 07 2.5 12.2 3.6 9.0 12.2 4.7 3 8.4 3.8 10.0 12.9 4.8 4 4.7 4.3 11.6 14.4 5.3 5 2.3 4.3 12.1 14.8 5.1 617 11 2.5 4.4 2.5 6.8 8.5 3.0 3 3.1 2.5 7.6 8.4 2.9 4 1.7 2.1 7.0 8.4 2.5 5 1.1 1.1 6.7 7.8 1.4 617 08 2.5 4.9 2.5 6.6 8.1 2.9 3 3.6 2.4 6.8 8.2 2.8 4 2.0 1.9 6.8 8.0 2.2 5 1.2 0.5 6.2 7.2 0.5 Distribution of luminous intensity in cd/1000 lm Cat.No 617 10 Cat.No 617 02 400 150 15 cd. 25 cd. -30 0 +30-30 0 +30 Cat.No 617 07 Cat.No 617 11 Lamps and batteries Cat.Nos Emergency lamps Batteries 617 10 607 51 618 92 617 02 607 51 618 92 617 07 607 51 618 85 617 11 607 51 618 85 617 08 607 51 618 92 80 cd. -30 0 +30 25 cd. -30 0 +30 Cat.No 617 08 30 cd. -30 0 +30 935

5108 self-contained emergency lighting luminaires 5108 self-contained emergency lighting luminaires Dimensions (in mm) Cat.Nos 6432 50/52 Backplate Cat.No 6432 51 170 167 90 420 417 6432 50 + 6432 54 Pack Cat.Nos 8 W maintained exit sign luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards, For escape route lighting, single or double sided use IP 20 - Class I Ni-Cd batteries, high temperature type Recharge time: 24 hours 5108 M1-1 h duration 1 6432 50 Power supply: 230 V +/- 10 % - 50/60 Hz Lumen output: 70 lm (single sided), 100 lm (double sided) Charge monitor: green LED 5108 M3-3 h duration 1 6432 52 Power supply: 240 V +/- 10 % - 50/60 Hz Lumen output: 30 lm (single sided), 50 lm (double sided) Charge monitor: red LED Accessories Backplate 10 6432 51 Backplate Pictogram plates Dim.: 417 x 167 mm 5 6432 54 5 6432 55 Grid Cat.No 609 06 442 451 474 Optical data Luminaire spacing, in metres, to provide 1 lux minimum illuminance 152 Ceiling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height (m) directly under D (m) D (m) D (m) D (m) luminaire (lux) 6432 50 (70 lm) single sided 2.5 2 1.5 4.5 7.2 2.2 3 1.4 1.2 4.5 6.9 1.4 3.5 1 0.5 4.3 6.3 1 6432 50 (100 lm) double sided 2.5 2.2 1.5 4.4 6.3 1.3 3 1.5 1.2 4.5 5.8 1.2 3.5 1.1 0.8 4.2 3.9 / 6432 52 (30 lm) single sided 2.5 0.8 / 2.5 3.3 / 3 0.6 / 1.8 2.15 / 6432 52 (50 lm) double sided 2.5 1.1 0.5 3 2.7 0.65 3 0.7 / 2.5 2.2 / 185 5 6432 56 1 609 06 Grid Distribution of luminous intensity in cd/1000 lm Cat.Nos 6432 50 (90 lm) Cat.Nos 6432 50 (100 lm) 6432 52 (30 lm) 6432 52 (50 lm) (cd/1000 lm) -150 +180 +150 +135 +120 187-135 +105-120 93-105 -75 93-45 +75 187-30 -15 0 +30 +40 C180 C270 C0 C90 (cd/1000 lm) -135-150 +180 +150 +135-120 -105 168 107 53 +120 +105-75 -45 53 107 168 +75 +45 C180 C270 C0 C90 Lamp and battery Cat.Nos Emergency lamp Battery 6432 50/52 609 41 6608 86 These products are part of emergency lighting systems > See p. 914-915 936

B 65 / NT 65 - weatherproof self-contained emergency lighting luminaires B 65 / NT 65 - weatherproof self-contained emergency lighting luminaires Dimensions (in mm) B 65 NT 65 73 109 124 225 279 309 405 615 61 618 34 Pack Cat.Nos Weatherproof non-maintained and combined luminaires Certified to IEC 60598-2-22 and EN 60598-2-22 standards Power supply: 230 V +/- 10% - 50/60 Hz IP 65 - IK 07 Suitable for mounting on inflammable surfaces Ni-Cd batteries, high temperature type Recharge time: 24 hours Screw terminals capacity: 2 x 1.5 mm 2 Rest mode with remote control unit (Cat.No 039 01) Charge monitor with high luminosity amber LEDs Autotest and addressable products incorporate an automatic self-testing system - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs display the result of the tests These autotest luminaires can operate as addressable luminaires by setting an address on internal microswitches and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat. No 625 15) and can be monitored on the building's plan with Legrand Vision System (LVS) software B 65 Standard Auto-test IP 65 - Class II Addressable 6 615 61-6 W non-maintained - 90 lm 1 615 62 615 67 6 W non-maintained - 165 lm 1 615 66-6 W combined - 155 lm NT 65 IP 65 - Class I Base of light filtting made of stamped sheet 1 618 34 8 W combined - 400 Im 1 618 35 11 W non-maintained - 715 Im 79 Optical data 90 134 146 Luminaire spacing, in metres, to provide 1 lux minimum illuminance Celling Lighting Axial to wall Axial spacing Transverse Transverse mounting level spacing to wall height directly (m) under D (m) D (m) D (m) D (m) luminaire (lux) 615 61 (90 Im) 2.5 4.8 2.3 6.3 6.7 2.5 3.0 3.4 2.3 6.5 7.0 2.4 4.0 1.9 2.0 6.5 6.9 2.0 5.0 1.2 1.2 6.1 6.3 1.2 615 66 (155 Im) 2.5 6.0 2.8 3.6 4.3 3.3 3.0 4.2 2.9 3.8 4.4 3.3 4.0 3.3 2.8 4.1 4.8 3.3 5.0 1.5 2.3 4.1 4.9 2.7 6.0 1.0 0.9 3.9 4.6 0.7 618 34 (400 Im) 2.5 16.7 4.0 5.0 7.3 5.7 3.0 11.6 4.3 5.4 7.7 6.0 4.0 6.5 4.6 5.9 8.3 6.2 5.0 4.2 4.8 6.3 8.6 6.2 6.0 2.9 4.7 6.6 8.7 6.1 615 62/67 (165 Im) 2.5 5.76 2.8 7.4 8.6 3.3 3.0 4.0 2.9 7.7 9.0 3.4 3.5 2.94 2.9 8.0 9.3 3.4 4.0 2.25 2.7 8.1 9.6 3.3 4.5 1.78 2.5 8.1 9.7 3 5.0 1.44 2.2 8.1 9.6 2.6 5.5 1.19 1.6 7.9 9.5 1.9 6.0 1.0 / 7.5 9 / 618 35 (715 Im) 2.5 29.66 5.01 12.26 15.04 6.0 3.0 20.61 5.35 13.02 16.04 6.37 3.5 15.13 6.67 14.08 16.96 6.70 4.0 11.58 5.91 14.88 17.72 6.95 4.5 9.15 6.14 15.48 18.28 7.15 5.0 7.41 6.32 16.12 19.00 7.29 5.5 6.13 6.42 16.62 19.66 7.40 6.0 5.15 6.51 17.10 20.10 7.44 Distribution of luminous intensity in CD / 1 000 lm Cat.Nos 615 62/67 Cat.No 615 66-30 0 Cat.No 618 34 40 cd. +30 40 cd. -30 0 Cat.No 618 35 +30 Lamps and batteries Cat.Nos Emergency lamps Batteries 615 61 607 51 618 92 615 62 607 51 618 83 615 66 607 51 618 83 615 67 607 51 618 83 618 34 609 51 618 86 618 35 607 53 618 89 125 cd. -30 0 +30 200 cd. -30 0 +30 937

conversion kits for emergency lighting luminaires 618 40 618 46 6640 75 6640 79 6640 70 6640 71 Made up with a slim charger/inverter module and a battery pack designed to fit fluorescent luminaires and convert them into stand-by lighting units in case of mains failure Compatible with magnetic and most electronic ballasts In the event of a mains failure, the converted luminaires will remain lit up for the rated duration of 1 hour or 3 hours The luminaires will resume normal operation and the battery will be recharged upon return of the mains supply Certified to EN 61347-2-7 standard ( Cat.Nos 618 40/42/46/48, other Cat.Nos) The conformity of these modules cannot by itself guarantee the overall conformity of the luminaire they are fitted to or incorporated into The installation and incorporation standards of the subassembly as a component must be strictly respected to ensure the overall conformity of the luminaire The converted luminaire manufacturer is responsible for proving the conformity of the overall installation and for ensuring that the relevant standards are met Able to operate either on non-maintained mode Operating ambient temperature: 10 C to 40 C Suitable for incorporation into luminaires with internal temperature up to 50 C To be installed apart in a remote box above 50 C Recharge time: 24 h. Green LED charge indicator. High temperature Ni-Cd batteries For conversion kits with environmental friendly Ni-MH batteries, consult us Automatic terminals Pack Cat.Nos Standard conversion kits 1 h duration - 230 V - 50/60 Hz For all lamps 1/10 618 40 For 6 to 36 W lamps 1/10 618 42 For 6 to 58 W lamps 1/10 618 46 For 6 to 58 W lamps For all lamps except T5 tubes 1/10 6640 75 For 10 to 18 W lamps 1/10 6640 76 For 13 to 38 W lamps 1/10 6640 77 For 26 to 58 W lamps 1 h duration - 230 V - 50/60 Hz For T5 lamps (with electronic ballasts only) 1/5 6640 78 For 14 to 24 W lamps 1/5 6640 79 For 28 to 54 W lamps 3 h duration - 230/240 V - 50/60 Hz For all lamps 1/10 618 48 For 6 to 58 W lamps For all lamps except T5 tubes 1/10 6640 70 For 10 to 18 W lamps 1/5 6640 71 For 13 to 38 W lamps 1/5 6640 72 For 26 to 58 W lamps For T5 lamps (with electronic ballasts only) 1/5 6640 73 For 14 to 24 W lamps 1/5 6640 74 For 28 to 54 W lamps Pack Cat.Nos Autotest / L.V.S. (Legrand Vision System) Addressable conversion kits for emergency lighting luminaires Compatible with all electronic ballasts Automatic self-testing system incorporated: - weekly test: emergency operation and lamp check - quarterly test: emergency operation and duration check - green (OK) and yellow (defect) LEDs and a buzzer to indicate the result of the tests These autotest conversion kits can operate as addressable kits by setting an address on internal microswitches (directly accessible on the top of the kits) and wiring a complementary bus line The operating state of the luminaires is controlled by the central control panel (Cat.No 615 15) and can be monitored on the building's plan with Legrand Vision System (L.V.S.) software Power supply: 230 V +/- 10% - 50/60 Hz 1/5 6640 80 For 10 to 58 W lamps - 1 h duration 1/5 6640 81 For 10 to 58 W lamps - 3 h duration These products are part of emergency lighting systems > See p. 914-915 938 Bold pack quantities: Minimum quantities to be ordered

conversion kits for emergency lighting luminaires Dimensions Cat.Nos 618 40/42/46/48 Module Cat.Nos 6640 75/76/77 Module 33 239 39.5 Between holes: 210 47 226 B A C D Cat.Nos A B C D 618 40 242 36 36-618 42 227 36-72 618 46 227 36 36-618 48 227 36-72 Cat.Nos A B C Battery type 6640 75 174.5 23.5-1 Stick 4 VTCs 6640 76 216.5 23.5-1 Stick 5 VTCs 6640 77 132.5 174.5 - - 46.5 1 Stick 3 VTCs 1 Stick 4 VTCs Cat.Nos 6640 70/71/72 31 31 Battery Battery A B C Module Cat.Nos 6640 78/79 Module 30 Between holes: 210 47 226 Between holes: 250 258 37 Battery Battery A B A B Cat.Nos A B Battery type 6640 70 186.5 33.5 1 Stick 3 VTD 6640 71 248 33.5 1 Stick 4 VTD 6640 72 307 33.5 1 Stick 5 VTD Cat.Nos A B Battery type 6640 78 174.5 46.5 2 Sticks 4 VTCs 6640 79 216.5 1 Stick 5 VTS 46.5 254 1 Stick 6 VTS Cat.Nos 6640 73/74 Module Cat.Nos 6640 80/81 Module 29 30 Between holes: 250 258 37 Between holes: 258 265 50 Battery Battery B A B C A C Cat.Nos A B C Battery type 6640 73 248 33.5-1 Stick 4 VTD 6640 74 186.5-67 2 x Sticks 3 VTD Cat.Nos A B C Battery type 6640 80 204 36 81 2 Sticks 4 VTCs 6640 81 288 36 81 2 Sticks 4 VTD 939

conversion kits for emergency lighting luminaires (continued) Ballast lumen (BLF) selection chart Lamp Wattage BLF (Ballast Lumen Factor) 618 40 618 42 618 46 618 48 6640 70 6640 71 T8 18 W 0.35 0.95 0.45 0.32 0.10 36 W 0.16 0.41 0.18 0.14 0.07 58 W - 0.33 0.15 0.11 T5 14 W 0.29 0.65 0.48 0.22 21 W 0.25 0.56 0.26 0.19 24 W 0.24 0.53 0.24 0.18 28 W 0.22 0.50 0.22 0.17 35 W 49 W 0.39 0.18 0.13 54 W 0.38 0.17 0.12 PLC 10 W 0.16 13 W 0.14 18 W 0.10 26 W 0.08 PLL 18 W 0.35 0.92 0.44 0.32 0.09 24 W 0.21 0.53 (2) 0.23 (2) 0.18 0.08 36 W 0.18 0.43 (2) 0.20 (1) 0.14 0.06 40 W 0.18 (3) 0.49 0.22 0.16 55 W 0.13 (3) 0.36 0.16 0.12 PLT 18 W 0.10 26 W 0.08 32 W 0.07 42 W 2D 10 W 0.40 (1) 0.88 0.14 0.19 16 W 0.48 (1) 0.90 (2) 0.42 (2) 0.30 0.12 21 W 0.40 0.76 (2) 0.33 (2) 0.25 0.10 28 W 0.31 0.61 (2) 0.28 (2) 0.20 0.07 38 W 0.26 0.57 0.20 0.19 0.06 55 W - - - - C 22 W 0.35 0.76 0.35 0.25 32 W 0.24 0.53 0.24 0.18 40 W 0.19 0.42 (1) 0.19 (2) 0.14 (1) Autonomy to 1h30 (2) Autonomy to 1h45 (3) Autonomy to 45 min (4) It's necessary to remove the switch Batteries Cat.Nos Battery type Battery specification 618 40 Ni-Cd 6.0 V - 1.5 Ah 618 42 Ni-Cd 7.2 V - 4 Ah 618 46 Ni-Cd 3.6 V - 4 Ah 618 48 Ni-Cd 7.2 V - 4 Ah 6640 70 Ni-Cd 3.6 V - 4/4.5 Ah 6640 71 Ni-Cd 4.8 V - 4/4.5 Ah 6640 72 Ni-Cd 6.0 V - 4/4.5 Ah 6640 73 Ni-Cd 4.8 V - 4/4.5 Ah 6640 74 Ni-Cd 7.2 V - 4/4.5 Ah 6640 75 Ni-Cd 4.8 V - 1.5/1.6 Ah 6640 76 Ni-Cd 6.0 V - 1.5/1.6 Ah 6640 77 Ni-Cd 8.4 V - 1.5/1.6 Ah 6640 78 Ni-Cd 9.6 V - 1.5/1.6 Ah 6640 79 Ni-Cd 13.2 V - 1.5/1.6 Ah 6640 80 Ni-Cd 9.6 V - 1.5 Ah 6640 81 Ni-Cd 9.6 V - 4 Ah 940

BLF (Ballast Lumen Factor) 6640 72 6640 73 6640 74 6640 75 6640 76 6640 77 6640 78 6640 79 6640 80/81 0.11 0.34 0.06 0.18 0.05 0.05 0.10 0.19 0.33 0.49 0.18 0.32 0.36 0.14 0.27 0.29 0.18 0.28 0.25 0.17 (4) 0.23 (4) 0.11 (4) 0.17 (4) 0.09 (4) 0.14 (4) 0.14 0.20 0.63 0.14 0.44 0.10 0.41 0.09 0.07 0.10 0.23 0.11 0.38 0.07 0.28 0.06 0.05 0.08 0.19 0.05 0.05 0.12 0.10 0.32 0.08 0.07 0.10 0.25 0.08 0.07 0.09 0.19 0.07 0.07 0.15 0.07 0.70 0.12 0.35 0.09 0.35 0.08 0.08 0.10 0.24 0.06 0.05 0.07 0.18 0.04 0.05 0.11 941

conversion kits for emergency lighting luminaires (continued) Wiring diagrams for conversion in maintained mode For Cat.Nos 618 40/42/46/48 With a conventional ballast and 1 tube L N 8 V min. SW Ballast For Cat.Nos 6640 70/71/72 (continued) With an electronic ballast and 1 tube L N SW Electronic Ballast 1 2 3 4 5 6 7 8 9 10 11 12 13 Battery With an electronic ballast and 1 tube L N 8 V min. SW Electronic Ballast For Cat.Nos 6640 73/74 With an electronic ballast and 1 tube L N SW Electronic Ballast 1 2 3 4 5 6 8 9 10 11 12 13 14 Battery For Cat.Nos 6640 70/71/72 With a conventional ballast L N With an electronic ballast, 6 terminals and 2 tubes L N SW Ballast SW Electronic Ballast 1 2 3 4 5 6 Module 7 8 9 10 11 12 13 1 2 3 4 5 6 8 9 10 11 12 13 14 942

Wiring diagrams for conversion in maintained mode (continued) For Cat.Nos 6640 75/76/77 With a conventional ballast L N SW Ballast With an electronic ballast and 1 tube L N SW Electronic Ballast 1 2 3 4 5 6 Module 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 For Cat.Nos 6640 78/79 With an electronic ballast and 1 tube L N SW Electronic Ballast With an electronic ballast, 6 terminals and 2 tubes L N SW Electronic Ballast 1 2 3 4 5 6 8 9 10 11 12 13 14 1 2 3 4 5 6 8 9 10 11 12 13 14 For Cat.Nos 6640 80/81 With an electronic ballast and 1 tube L N With an electronic ballast, 6 terminals and 2 tubes L N SW Electronic Ballast SW Electronic Ballast BUS 1 2 3 4 5 6 7 8 ON ON 50 cm OFF OFF 9 10 11 12 13 14 15 16 BUS 1 2 3 4 5 6 7 8 ON ON OFF OFF 9 10 11 12 13 14 15 16 50 cm 50 cm 50 cm 943

LIPSO, EMERGENCY LIGHTING PILOTS >>> As easy to install as an ordinary switch Signalling Under normal conditions, a decorative element designed to integrate smoothly into any public building Signalling direct lighting to enhance the decor of the building Emergency with a direct lighting Emergency In the event of a power cut, a light path is created to guide the audience to the exit, the perfect complement to emergency lighting These products are part of emergency lighting systems > See p. 914-915 944

Lipso self-contained emergency lighting pilots 230 V Lipso self-contained emergency lighting pilots dimensions Dimensions Lateral lighting Frontal lighting 48 48 6609 03 6609 11 6609 11 + 6609 45 58 58 Self-contained emergency lighting pilots, certified to EN 60598-2-22 standard Frontal or lateral lighting Aluminium colour zamak finish Class II Leds requiring no maintenance as lamp sources: - For self-contained and centralized pilot lights: 4 high luminosity colour LEDs for signalling and indicating battery charge 3 high luminosity white LEDs for emergency lighting - For 230 V pilot lights: 7 high luminosity colour LEDs Duration: 1 hour Ni-Cd batteries: 2.4 V - 2/3 AAA Charging time: 24h Lumen output: 1.5 lm Screw terminals capacity for 2 x 1.5 mm 2 For installation in their own flush-mounting box, an 60/65 mm box or a plasterboard partition Installation: Flush-mounting on box Cat.No 6609 41 Ø 50 55,5 62 55,5 20 7 62 Pack Cat.Nos Self-contained emergency lighting pilots 230 V 10 % - 50/60 Hz IP 44 - IK 07 Lateral Front lighting lighting White emergency lighting, and signalling in: 1 6609 01 6609 11 Blue 1 6609 02 6609 12 White 1 6609 03 6609 13 Red 1 6609 04 6609 14 Green 1 6609 05 6609 15 Amber IP 66 - IK 08 White emergency lighting, and signalling in: 1 6609 07 6609 17 Blue 1 6609 06 6609 16 White 230 V lighting pilots IP 44 - IK 07 Lateral Front For 230 VA mains voltage only, with lighting lighting 7 signalling LEDs in: 1 6609 51 6609 53 Blue 1 6609 52 6609 54 White Accessories 10 6609 41 Flush-mounting box 1 6609 42 Adaptor frame for 60/65 mm box 1 6609 43 Adaptor for plasterboard partition 1 6609 44 Round frame 68 mm 1 6609 45 Square frame 68 x 68 mm Accessories: Flush-mounting on 60/65 mm box with box adaptor frame Cat.No 6609 42 Ø 78 74 43 15 Flush-mounting for prefabricated partitions Cat.No 6609 43 45 Ø 45 10 mini 30 maxi Flush-mounting on box Cat.No 6609 41 with round frame Cat.No 6609 44 Ø 50 21 8 62 68 7 30 Ø 78 Flush-mounting on box Cat.No 6609 41 with square frame Cat.No 6609 45 Ø 50 68 These products are part of emergency lighting systems > See p. 914-915 21 8 62 68 945

twin spot lights self-contained emergency lighting luminaires halogen spot lights self-contained emergency lighting luminaires 639 93 6608 42 Pack Cat.Nos Twin 20 W halogen spot lights non-maintained luminaires Ideal for lighting large open areas or undefined, escape routes Particularly suitable for factory or warehouse areas where premises have high ceilings Certified to IEC 598-2-22 and EN 60598-2-22 Power supply: 230/240 V - 50/60 Hz Steel housing is white epoxy power coated to ensure corrosion resistance Supplied with 2 x 20 W halogen lamps Lumen output: 2 x 400 lm Maintenance free sealed lead acid battery (12 V - 7 Ah, Cat.No 407 49), (1 for 1 h duration, 2 for 3 h duration) Recharge time: 24 h nominal (14 h for 1 h duration) Cable entry: 20 mm conduit knockout at one end Operating temperature: 0 to 25 C BBK 1 639 92 1 h 1 639 93 3 h Pack Cat.Nos Halogen spot lights non-maintained IP 55/IP 45 luminaires Certified to EN 60598-2-22 standard Power supply: 230 V +6-10% - 50/60 Hz Lamp and emergency operation with a push-button Ni Cd batteries, high temperature type Recharge time: 24 hours Charge monitor with a green LED Grey colour enclosure 2 lamps IP Lumens output Lamp 1 6608 42 IP 55 900 2 x 35 W 1 6608 43 IP 45 1 500 2 x 65 W 946

twin spot lights self-contained emergency lighting luminaires Twin 20 W halogen spot lights non-maintained luminaires Dimensions (in mm) 360 128 178 72 Distribution of luminous intensity in cd/ 1 000 lm Cat.No 6608 42 90 210 335 210 2500 cd. -30 0 +30 315 68 Distribution of flood light Elevation Elevation Maximum permitted spacing (in metres) to achieve 1 lux luminaire to wall Height (m) Elevation angle Luminaire to Luminaire Luminaire to wael 3 66 17.4 m 8.0 m 4 50 13.3 m 5.7 m 5 25 10.0 m 3.5 m Figures are given for guidance purposes Height, "luminaire to luminaire" figures assume the spolights are mounted in a horizontal attitude, with front faces of each spot pointing at the noted elevation angle and away from each other "Luminaire to Wall" figures can be used to determine the extent of an escape route in any direction from the luminaire In both cases, the center line of the escape route is assumed to pass directly underneath the luminaire with the spots aimed along the centre line of the escape route 4000 cd. -30 0 +30 Halogen spot lights non-maintained IP 55/IP 45 luminaires Dimensions (in mm) Cat.Nos 6608 42/43 C D A B E Cat.Nos Dimensions (mm) A B C D E 6608 42 330 370 260 430 124 6608 43 380 420 290 470 124 947