MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Similar documents
MODEL PS-4 DIGITAL PORTION SCALE

Price Computing Scale D Series Operation Manual

Patient Lift Scale Indicator Owner s Manual

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

Price Computing Scale DS Series Operation Manual

PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual

DIGITAL Pediatric Scale Models 8435 & 8435KG Owner s Manual

DIGITAL PHYSICIAN Waist-High Scale. Eye-Level Scale. Model 6127 Series, 6129 Series and. Models 6337 and 6339 Operating Instructions

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

ELECTRONIC PHYSICIAN Waist-High Scale 6027 and 6029 Series Owner s Manual

IB-400. Weighmobile. Owner's Manual

Digital Stand-On Sit-Down Scale Models 6868 & 6868KGEU Operating Instructions

PD100 PD200 PD300 PD300DHR

Digital Stand-On Sit-Down Scale Models 6876 & 6876KGEU Operating Instructions

DIGITAL PHYSICIAN Eye-Level Scale

PD100 PD200 PD300 PD300DHR

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

DIGITAL PHYSICIAN Waist-High Scale

SONARIS Sonar Stadiometer Owner s Manual

Digital Stand-On Sit-Down Scale Models 6868/6868KGEU Operating Instructions

Waist-High Digital Bariatric Scale Model 685X Series Operating Instructions

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

IB-600. Weighmobile. Owner's Manual

7550 Fold-up Stationary Wheelchair Scale Installation and Operation Manual

Model DS7060 Handrail Scale. User Manual

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

SPC Series. Digital Scale. Operation Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Compact Scales. Software Revision V1.25 & above

Adam Equipment CPW COMPACT SCALE

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

SSP-Series Portable Balances Operation Manual

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Ohaus ES Series Bench Scale

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Valor 2000 Series Instruction Manual

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

AP30 MkII Postal Scale INSTRUCTION MANUAL

Solar mosquito killer

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Virtual Measurements & Control. VC210 Operators Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

User Guide. Digital Shipping Scale S150

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

DC POWER SUPPLY ALIMENTATION C.C.

MS300 P latform S cale

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Models XMC/XWS/XWT (-S) -XIS

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Catapult 1000 Series Instruction Manual

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Weighing Scale IDS-802. User Manual

Operating instructions Platform/floor scales

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

uline.com

PORT-A-WEIGH CRANE SCALES

Quick Guide. brite Advanced Retail scale

Premier Mobile Electric Lift Table Setup Manual

Marin Control Digital

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

CITIZEN. series. Precision Balances

Model 7400 OPERATOR MANUAL

Model 700 Microarray Oven

Model 8000XL OPERATOR MANUAL

Peninsula Folding Lift Table Manual

Model WS-6020U Solar Station QUICK SETUP GUIDE

Midmark Electric Lift Table Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

CED PRO II. High Precision Electronic Scale Instructions

This page intentionally left blank. Cab Control 400

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR PORTABLE SCOREBOARD MODEL MP-6300

COATING THICKNESS GAGE NOVOTEST TP-1

Operating manual Platform/floor scales

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL

In accordance with the Gallagher policy of continuing development, design and specifications are subject to change without notice.

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

MS-4200/4201/4202/4202L USER MANUAL

F5 Platforms: FIPS Kit Installation MAN

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

Version /26/09

Thermocouple Thermometer Models

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Transcription:

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG. CO. 8528-0409-0M Rev A PO BOX 151 WEBB CITY, MO 64870 04/15 PH (417) 673-4631 FAX (417) 673-5001 www.detectoscale.com Technical Support: Ph: 866-254-8261 techsupport@cardet.com

2

INTRODUCTION Thank you for purchasing our Detecto Model WPS12 Waterproof Digital Portion Scale. This manual will guide you through installation, and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference. FCC COMPLIANCE STATEMENT This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference. You may find the booklet "How to Identify & Resolve Radio-TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402. The stock number is 004-000-00345-4. All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. Serial Number Date of Purchase Purchased Form RETAIN THIS INFORMATION FOR FUTURE USE TABLE OF CONTENTS Installation.... 1 Unpacking.. 1 Power Supply.... 1 Battery Pack...... 1 Battery Charging... 1 Low Battery.... 1 Display Annunciators..... 2 Key Functions..... 3 Operation..... 4 Configuration... 5 Gravity Compensation... 6 Display Messages... 7 Care and Maintenance... 7 SPECIFICATIONS Weight Display: 5Digits, Height 24.3mm, HTN Dimensions: Platform Size: Zero: Power: Tare: Temperature Operation: Storage: Capacity: Keys: Features: PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "NOTIFICATION" symbols: IMPORTANT 187mm x 246mm x 57mm 184 mm x 172mm Established on power up routine and maintained by auto-zero circuitry. AC adapter: 120 VAC input 9v, 100mA output Battery: Ni-MH rechargeable 4.8 VDC 1800 ma 100% of full scale capacity 40 to 105 F (5 to 40 C) 140 F (60 C) Maximum 12lb x 0.1oz, 12lb x 1/8 oz, 12lb x 0.005 lb, 192 oz x 0.05 oz, 192 oz x 1/8 oz, 5500g x 1 g ON/OFF, TARE, UNITS/Back Light, SET IP67 ELECTRICAL WARNING 1

2

INSTALLATION UNPACKING Before beginning installation of your scale, make certain the instrument has been received in good condition. When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit. 1. Remove the scale from the shipping carton and inspect it for any signs of damage. 2. Plug-in the adapter to use the scale and begin charging the battery pack. Refer to the POWER SUPPLY or BATTERY PACK sections of this manual for more instruction. 3. Place the scale on a flat level surface, such as a table or bench. 4. The scale is now ready for use. POWER SUPPLY To apply power to the scale using the supplied power supply, insert the plug from the power supply cable into the power jack on the side of the scale and then plug power supply into the proper electrical outlet. The scale is now ready for operation. BATTERY PACK The scale uses a 4.8 VDC, 1800 ma built-in rechargeable battery pack. The WPS12 can operate for up to 80 hours of continuous use with a fully charged battery pack. BATTERY CHARGING To recharge the battery pack, the power supply must be connected to an AC power outlet and plugged into the scale. It will take approximately 5 hours to fully recharge the battery pack in the scale. While the batteries are charging the WPS12 can still be operated. Note that charging the battery pack for more than 12 hours will not damage it. LOW BATTERY When the battery pack is near the point it needs to be recharged, a low battery indicator on the display will turn on. If the battery voltage drops too low for accurate weighing, the scale will automatically shut off and you will be unable to turn it back on. When the low battery indicator is displayed, the operator should plug the power supply into the scale and then into the proper electrical wall outlet. The scale will begin charging the battery pack. 1

DISPLAY ANNUNCIATORS The annunciators are turned on to indicate that the scale display is in the mode corresponding to the annunciator label or that the status indicated by the label is active. The O annunciator is turned on when the weight display is stable. lb The lb annunciator is turned on to indicate that the displayed weight is in pounds. oz The oz annunciator is turned on to indicate that the displayed weight is in ounces. lb oz Both the lb and oz annunciators are turned on to indicate that the displayed weight is in pounds and ounces. g The g annunciator is turned on to indicate that the displayed weight is in grams. The low battery annunciator is used with the battery operation. It will turn on to indicate that the batteries will soon need to be recharged. Low limit setting annunciator High limit setting annunciator 2

KEY FUNCTIONS UNITS / 1. Press to change the weighing units to the alternate units of measurement (if selected during configuration of the scale). 2. Press and hold three (3) seconds to turn display back light on or off.- TARE 1. Press to reset the displayed weight to zero up to 100% of the scale capacity. ON/OFF 1. Press and release to turn on scale. 2. Press and release to turn the scale off. 3

OPERATION TURN THE SCALE ON Press the ON/OFF key to turn the scale on. The scale will display all display segments then change to zero weight. SELECT THE WEIGHING UNIT Press the UNITS key to alternate between the selected weighing units. NOTE: Multiple weighing units must be enabled during configuration for this function to be operational. WEIGH Place the item to be weighed on the scale tray. Scale will display item weight. TO RE-ZERO THE WEIGHT DISPLAY To Zero or Tare the weight display, press the TARE key and continue. The scale will re-zero / TARE until the full capacity is reached. TARE To weigh ingredients in a container you must first TARE the weight of the container so that only the net weight of the ingredient is displayed. 1. Place empty container on scale platform while scale is OFF 2. Turn scale on. Display will show zero weight. 3. Add ingredient to container. Scale will display weight of ingredient. 4. To weigh additional ingredients, press TARE before adding each ingredient. 5. To display the total weight of ingredients press the SET and TARE keys at the same time. 6. Note that upon removing the container and ingredients the scale will display a negative weight. Press the TARE key to return the scale to zero. HIGH / LOW WEIGHT CHECKING The scale may be set to alert you when either over or under a set limit. 1. Press and hold the TARE key for 3 seconds. The scale will beep and display the low weight annunciator 2. Place weight equal to low weight limit on scale and press SET. Scale will beep indicating low limit is set. Scale will display the high weight annunciator. 3. Add weight to scale until weight is equal to desired high weight limit. Press SET. Scale will beep indicating high limit is set. Remove weight from scale. The scale will now beep and display will indicate if item placed on scale is over or under the set limits. To clear the HIGH / LOW settings, press SET and TARE keys at the same time The membrane keyboard is not to be operated with pointed objects (pencils, pens, fingernails, etc.). Damage to keyboard resulting from this practice will NOT be covered under warranty. 4

CONFIGURATION The Scale has been pre-configured at the factory and should not require configuration for use in most applications. In the event that the factory settings do not meet the requirements of your application, the following describes the steps to configure the scale. TO BEGIN CONFIGURATION: 1. Press the ON/OFF key to turn on the scale. 2. Press and hold the SET key for 3 seconds. When the display shows, release the SET key to enter the Configuration mode. The display will change to show. WEIGHING UNITS To select lb/oz (pounds/ounce) weighing units (12 lb x 0.1 oz): 1. With the display showing, press the SET key. The display will change to show and the status ( or ). 2. Press the UNIT key to toggle between: Enable (display will change to ) or Disable (display will change to ). 3. Press the SET key. 4. Repeat above steps for each weighing unit mode : g = grams (5500g x 1 g) lb oz = pound ounces (12 lb x 0.1 oz) lb oz 1/8 = pound / 1/8 ounces (12 lb x 1/8 oz) lb = pounds only (12 lb x 0.005 lb) oz = ounces (192 oz x 0.05 oz) oz 1/8 = 1/8 ounces (192 oz x 1/8 oz) 5. The display will return to. 6. Press UNIT key to proceed to AUTOMATIC SHUTOFF AUTOMATIC SHUTOFF 1. The display will change to AOFF. 2. Press the SET key to begin selection of the automatic shut-off time (in seconds). 3. Press the UNIT key to toggle through the selections,,,,, or. 4. When the desired time or Off is displayed, press the SET key. 5. The display will return to. 6. Press UNIT key to proceed to GRAVITY COMPENSATION. 5

GRAVITY COMPENSATION 1. With the display showing : CONFIGURATION, CONT. To Enable the Gravity Compensation mode, press the SET key. The display will change to (use the factory set value of 9.797). To Disable the Gravity Compensation mode, press the UNIT key. The display will change to (use the value obtained from the factory Tech Support). 2. Press the SET key again. The display will change to show. 3. Press the UNIT key. The display will change to show. 4. Press the SET key to save the settings and reset the scale. 5. Setup is complete. GRAVITY COMPENSATION The Gravity Compensation for your scale has been pre-configured at the factory and should not require changing in most locations. In the event that the factory settings do not meet the requirements of your location, contact the factory Tech Support for the value for your location. With enabled in the function setting of the Configuration mode, the scale will use the factory set value of 9.797 for the Gravity Compensation. If the is disabled, the scale will use the value obtained from the factory Tech Support and entered by the operator for the Gravity Compensation. To change the Gravity Compensation value: 1. Press and hold the UNIT key while pressing the ON/OFF key to turn on the scale and enter Gravity Compensation mode, the display will show 9.797 (or the current value). 2. Press the UNIT key to increase the value or TARE key to decrease the value to achieve the desired value. 3. Press the SET key to confirm the entered gravity and return the scale to the normal operating mode. CALIBRATION PROCEDURE 1. While the scale is off, press and hold the ON/OFF key. 2. Once all display segments are on, release the ON/OFF key and immediately and press the UNIT key three (3) times. 3. The scale will show 11111 55555, and finally show the counts of zero. 4. Press the SET key. The scale will show 0g and then go back to the counts. 5. Place a 5.5 kg test weight on the scale and then press the SET key. 6. The scale will show 5500g, and change to show CAL, and then automatically turn off. 7. Remove the test weight from the scale. 8. The scale is ready for normal operation. 6

DISPLAY MESSAGES DISPLAY MEANING Low battery indication E 2 prom Error Over capacity CARE AND MAINTENANCE The heart of the WPS12 Waterproof Digital Portion Scale is a precision load cell located in the center of the scale base. It will provide accurate operation indefinitely if protected against overload of scale capacity, dropping items on scale, or other extreme shock. DO NOT use acetone, thinner or other volatile solvents for cleaning. DO NOT expose scale to direct sunlight or temperature extremes. DO NOT place scale in front of heating/cooling vents. DO clean the scale with a damp soft cloth and mild non-abrasive detergent. DO clean the scale by submerging in dishpan and using mild non-abrasive detergent. NOTE: Before submerging scale in dishpan, make sure power jack cover on side of scale is completely inserted, battery pack cover on bottom of scale is installed and water temperature does not exceed 140 F (60 C). DO remove AC power before cleaning with a damp cloth or submerging scale in dishpan. DO provide clean AC power and adequate protection against lightning damage. DO keep the surroundings clear to provide clean and adequate air circulation. DO NOT PLACE SCALE IN COMMERCIAL DISHWASHER TO CLEAN! 7

8