* * Rev. 9 01/18 Product Manual

Similar documents
Signet 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet ph/orp Electrodes

Signet ph/orp Electrodes

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

Signet ph/orp Electrodes

SIGNET 2750 ph/orp Sensor ENGLISH

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Assembly

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes

* * Rev. F 03/16 Operating Instructions

SIGNET 3719 ph/orp Wet-Tap

Signet V(D) to V(D) PVDF Conductivity Electrodes

* * Rev M 10/14 Operating Instructions

Signet ph/orp Transmitter

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 515 Rotor-X Paddlewheel Flow Sensors

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET Temperature Transmitter

Signet 515 Rotor-X Paddlewheel Flow Sensors

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Signet Temperature Transmitter

Signet 4150 Turbidimeter

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet Pressure Transmitter

* * Rev /18 Operating Instructions

Signet 2517 Brass Paddlewheel Flow Sensor * *

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

General Purpose ph/orp Sensors

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

OPERATING INSTRUCTION MANUAL

General Purpose ph/orp Sensors

Measurement and Instrumentation

Signet 2552 Metal Magmeter

NEW QUICK CABLE-TO-SENSOR RELEASE,

User s Guide Shop online at omega.com SM For latest product manuals: CDE-285X SERIES Conductivity Sensors

Signet Pressure Transmitter

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Signet 2552 Metal Magmeter

ph/orp Sensor Model 399 ph/orp

Signet 7000/7001 Vortex Flow Sensors * *

SIGNET Vortex Flow Sensors ENGLISH

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

Instrument Enclosure Assemblies

Signet 8150 Flow Totalizer

Signet 2551 Magmeter Flow Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+

Chapter Page. 1 Introduction Description 1

Signet Measurement and Instrumentation

8000 Series ph/orp Electrode Platform Product Instructions

DPU90-WM, FP90UM, FP90IM, PHTX-27G, PHTX-275G, FPM-5000-LTCK, FPM-5000-MB

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Signet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap

Signet Measurement and Instrumentation

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Automation Made Easy 2013 Signet Measurement and Control Product Catalog

User s Guide FP-5060 SERIES. Micro-Flow Sensors. Shop online at omega.com SM For latest product manuals:

7777 Immersion/In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

User s Guide PH-2720-PA. Preamplifier. Shop online at.

Retractable ph/orp Sensors

Insertion/Submersion Flow Through Sensor

2-ELECTRODE CONDUCTIVITY SENSORS

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

FMK-2536, FP-5100, FP-5300,FP-5600, FP-8500, FP-8500A

Accessories Guide ph/orp/conductivity Sensors

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

+GF+ SIGNET 2550 Insertion Magmeter

TUpH Retraction/Submersion/Insertion ph/orp Sensors

JUMO MIDAS S05 Pressure transmitter Type

Analytical Instruments Two-Electrode Conductivity Sensors

Bante220 Portable ph Meter Instruction Manual

2100 Turbine Flow Sensor

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Retractable ph/orp Sensors

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

OPERATING INSTRUCTION MANUAL

ELECTRICAL INSTALLATION

ACTIVE ELECTRODELESS SENSORS Instruction Manual

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

C7170A,B Encapsulated Temperature Sensor

Series 10-ZSE40A(F)/10-ISE40A

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

Combination ph/redox (ORP) Sensors

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Transcription:

English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line of sensors for industrial fluid measurement and control. There are two styles of preamplifiers, and each is available with NPT or ISO threads at the cable outlet. They all connect to four different families of ph and ORP electrodes to supply an amplified mv (analog) signal to Signet instruments. Table of Contents Warranty Statement... 2 Product Registration... 2 Safety Information... 2 Chemical Compatibility... 2 Specifications... 2 Dimensions... 3 In-Line Assembly and Installation... 3-4 Wet-Tap Assembly and Installation... 4 Submersible Sensor assembly and Installation... 5 Wiring to Signet Instruments... 6 Wiring from DryLoc Preamplifier to Others Equipment... 7 Ordering Information... 8 English Deutsch Français Español

Warranty Information Refer to your local Georg Fischer Sales office for the most current warranty statement. All warranty and non-warranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales office or distributor. Product returned without a Service Form may not be warranty replaced or repaired. Signet products with limited shelf-life (e.g. ph, ORP, chlorine electrodes, calibration solutions; e.g. ph buffers, turbidity standards or other solutions) are warranted out of box but not warranted against any damage, due to process or application failures (e.g. high temperature, chemical poisoning, dry-out) or mishandling (e.g. broken glass, damaged membrane, freezing and/or extreme temperatures). Product Registration Thank you for purchasing the Signet line of Georg Fischer measurement products. If you would like to register your product(s), you can now register online in one of the following ways: Visit our website www.gfsignet.com. Under Service and Support click on Product Registration Form If this is a pdf manual (digital copy), click here Safety Information 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifications. 4. Wear safety goggles or faceshield during installation/service. 5. Do not alter product construction. 6. When using chemicals or solvents care should be taken and appropriate eye, face, hand, body, and/or respiratory protection should be used. Caution / Warning / Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death Electrostatic Discharge (ESD) / Electrocution Danger Alerts user to risk of potential damage to product by ESD, and/or risk of potential of injury or death via electrocution. Personal Protective Equipment (PPE) Always utilize the most appropriate PPE during installation and service of Signet products. Pressurized System Warning Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Chemical Compatibility WARNING The retaining nuts of certain ph and ORP sensors and preamplifiers are not designed for prolonged contact with aggressive substances. Strong acids, caustic substances and solvents or their vapor may lead to failure of the retaining nut, ejection of the sensor and loss of the process fluid with possibly serious consequences, such as damage to equipment and serious personal injury. Retaining nuts that may have been in contact with such substances, e.g. due to leakage or spilling, must be replaced. Specifications General Compatible Electrodes Signet DryLoc Electrodes... 2724-2726, 2756-WTP- 2757-WTP, 2764-2767, 2774-2777 Compatible Instruments Preamplifier models to Signet 5700, 8750... 2760-1, -2, -11, -21 Response Time (includes response time of electrodes): ph... < 6 sec. for 95% of change ORP... application dependent Temperature, τ... 20 sec. Electrical (2760-1, -2,-11, -21 Preamplifiers) Maximum Offset... ± 7 mv Input Impedance, Z... > 1011 Ω Supply Voltage (V+ to V )... 6 to 12 VDC Current consumption... < 1 ma Environmental Enclosure Rating... 2760-1, -2, NEMA 6P/IP68 2760-11, -21, NEMA 4 with electrode and watertight conduit and/or extension pipe connected Materials Submersible versions... CPVC (Gray) In-Line versions... PBT (Yellow) Cable... 4.6 m (15 ft) 6-conductor w/shield, 22 AWG Maximum cable:... 122 m (400 ft) Shipping Weight:... 0.64 kg (1.41 lb) Operating Temperature... 0 C to 85 C (32 F to 185 F) Storage Temperature... 20 C to 85 C ( 4 F to 185 F) Relative Humidity... 0 to 95%, non-condensing (without electrode connected) Standards and Approvals Manufactured under ISO 9001 and ISO 14001 China RoHS (Go to www.gfsignet.com for details) Hand Tighten Only Overtightening may permanently damage product threads and lead to failure of the retaining nut. Do Not Use Tools Use of tool(s) may damage product beyond repair and potentially void product warranty. 2 Signet 2760 DryLoc ph/orp Preamplifier

Dimensions 3-2760-1 Preamplifier, Sub, NPT 3-2760-2 Preamplifier, Sub, ISO 31.75 mm (1.25 in.) 3-2760-11 Preamplifier, In-line, NPT 3-2760-21 Preamplifier, In-line, ISO 35.0 mm (1.38 in.) 70.1 mm (2.76 in.) 89.4 mm (3.52 in.) 101 mm (4.0 in.) 56.6 mm (2.23 in.) 61.0 mm (2.40 in.) In-line Assembly and Installation 2760 In-Line models used with 2724-2726 series electrodes: 1. The 2724-2726 can use a Signet installation fitting. Electrodes are sealed by the O-ring when it is installed into a Signet installation fitting. Lubricate O-rings 2. The lower threaded nut is required to attach the electrode to the installation fitting when using a Signet fitting. 3 HAND-TIGHTEN THE THREADED NUT ONTO THE INSTALLATION FITTING. DO NOT USE TOOLS! DO NOT USE THREAD SEALANT OR LUBRICANTS ON THE FITTING THREADS OR THE SENSOR CAP. Unlock 100 mm (4 in.) Lock 3. Lubricate O-rings with a non-petroleum based, viscous lubricant (grease) compatible with the system. 4. Seat the 2760 DryLoc connector onto the top of the electrode. 1 2 4 5 Open the DryLoc connector by turning the upper locking ring ¼-turn clockwise. 5. Turn the locking ring ¼-turn counter-clockwise to lock the preamplifier in place. The mechanism will click when it is locked. When fully assembled the 2760 will stand about 100 mm (4 in.) above the installation fitting. 2760 In-Line models used with 2764-2767 or 2774-2777 series electrodes: BEFORE YOU START: 2764-2767: Install a 1 in. NPT pipe tee into the process line. 2774-2777: Install a ¾-in. reducing tee into the process line. 1. Wrap the process threads on the electrode with an appropriate sealant (example: PTFE tape ) to create a water-tight connection. HAND-TIGHTEN the electrode into the installation fitting. DO NOT USE TOOLS! NOTE: The lower threaded nut may be dropped onto the top of the electrode or it may be discarded. It is not used with these electrodes. 2. Lubricate O-rings with a non-petroleum based, viscous lubricant (grease) compatible with the system. 3. Seat the 2760 DryLoc connector onto the top of the electrode. Open the DryLoc connector by turning the upper locking ring ¼-turn clockwise. Lubricate O-rings 2 4. Turn the locking ring ¼-turn counter-clockwise to lock the preamplifier in place. The mechanism will click when it is locked. When the 2760 Preamplifier is fully assembled with one of the threaded electrodes (276X and 277X models) it will stand approximately 178mm (7 in.) from the process threads to the top of the preamplifier. Unlock 178 mm (7 in.) 1 3 4 Lock Signet 2760 DryLoc ph/orp Preamplifier 3

RELAY 1 In-line Assembly and Installation 2760 Submersible models used as in-line system: The Submersible 2760 design can also be used in-line when using the 2724-2764, 2764-2767 series or the 2774-2777 series electrodes. 2760 Preamplifier BEFORE YOU START: 2764-2767: Install a 1 in. NPT pipe tee in the process line. 2774-2777 and 2724-2726: Install a ¾-in. reducing tee in the process line. DO NOT install in a ¾-inch tee or probe will be damaged. 1. Wrap the process threads on the electrode with an appropriate sealant (example: PTFE tape) to create a water-tight connection. Threaded nut 2. Lubricate O-rings with a non-petroleum based, viscous lubricant (grease) compatible with the system. 3. Remove the threaded nut from the preamplifier and place it around the electrode from the bottom as illustrated. 4. HAND-TIGHTEN the electrode into the installation fitting. DO NOT USE TOOLS! 5. Seat the 2760 DryLoc connector onto the top of the electrode. 6. Lift the threaded nut up and thread it hand-tight onto the preamplifier. When the 2760 Preamplifier is fully assembled with one of the threaded electrodes (276X and 277X models) it will stand approximately 178 mm (7 in.) from the process threads to the top of the preamplifier. Electrode 1 Lubricate O-ring 2 3 4 5 6 178 mm (7 in.) The 2760 Preamplifier signal can be routed to a Signet 5700 ProPoint ph Monitor, or to any model of the 3-8750 ph Transmitter. If the preamplifier cable must be extended beyond the standard 4.6m (15 ft) that is supplied with the 2760, use a junction box to terminate the wires. Note: Do not extend the 2760 cable more than 120 m (400 ft). Wet-Tap Assembly and Installation The 2760 DryLoc Preamplifier can be used to connect Signet 275X Wet-Tap electrodes to a ph or ORP instrument. 1. Select the process fitting. Select a low profile installation saddle (customer-supplied) with a 1½ in. or 2 in. outlet (depending on 3719 model ordered). The 3719 is available with NPT or ISO thread options. The 3719 can also be adapted to fit into tee fittings. Refer to the 3719 ph Wet-Tap instructions for detailed information. 2. Install the Wet-Tap and the electrode. Install the 3719 into the fitting, then insert the electrode into the assembly. 3. Attach the preamplifier to the electrode. Attach the 3-2760-11 or -21 Preamplifier to the DryLoc fitting at the top of the electrode. 4. Connect the 2760 Preamplifier to the instrument. The 2760 Preamplifier signal can be routed to any 5700 or 8750 ph/orp instrument (see Pg. 5). 1. 2. 3. 4. Lubricate O-rings 4 2 Lubricate O-rings 4 Signet 2760 DryLoc ph/orp Preamplifier

Submersible Sensor Assembly and Installation The submersible 2760 can be installed in a tank or vessel if conditions are within pressure and temperature specifications. The 2760 is able to withstand fluid temperatures up to 85 C (185 F), but the electrode tolerances vary. Check the specifications of each component before installation. 1. Insert any DryLoc electrode into base of the 2760. Lubricate O-rings with a non-petroleum based, viscous lubricant (grease) compatible with the system. 2. Thread retaining cap over electrode and hand-tighten onto 2760. Keep the DryLoc electrical interconnection between electrode and preamplifier dry and clean at all times. 3. Attach 3 /4 in. watertight pipe to the top of the 2760. Secure the threaded connection to prevent any leakage. Fill the lower 75-100 mm (3 to 4 in.) of conduit or extension pipe with a flexible sealant such as silicone to prevent liquid accumulation on the back seal of the 2760. 3 1 Fill with 75-100 mm (3 to 4 in.) of sealant 2 Lubricate O-ring 55 mm (2.16 in.) 55 mm (2.16 in.) Use standard installation hardware to connect the submersible 2760 directly to external equipment. OR The 8052-1 NPT Mount Junction box connects to 3 /4 in. pipe or conduit and provides convenient wiring termination. OR The 8050-1 Universal Mount junction box mounts flat onto a wall or can be strapped to a post or pipe. ½ in. NPT threads Fill with 75-100 mm (3 to 4 in.) of sealant Fill with 75-100 mm (3 to 4 in.) of sealant Fill with 75-100 mm (3 to 4 in.) of sealant Signet 2760 DryLoc ph/orp Preamplifier 5

Wiring to Signet Instruments Any of these electrodes can be connected to the Signet ProPoint and ProcessPro ph instruments using the 3-2760-1(X) or -2(X) Preamplifiers. Wiring diagrams illustrate the actual terminals on these products for convenience. Signet 8750-X ProcessPro ph/orp Transmitter RELAY 1 4 2 Signet 5700 ProPoint ph/orp Monitor Standard output, Signet installation fittings 3-2724-10, -11 3-2725-60, -61 3-2726-10, -11 3-2726-HF-10, -11 3-2726-LC-10, -11 3-2756-WTP-1 3-2757-WTP Standard output, ¾ in. process connector. 3-2774 3-2775 3-2776 3-2777 Differential output, 1 in. process connector. 3-2764-1 3-2765-1 3-2766-1 3-2767-1 3-5700 ph/orp Monitor mv Input Brown wire Iso. Gnd Blue wire T + Green wire T - White wire V + Red Wire V - Black wire Brown mv Blue Iso. Gnd Green T+ White T- Red V+ Black V- 3-2760-1 3-2760-2 3-2760-11 3-2760-21 + - 4-20 ma ProcessPro ph/orp Transmitter 3-8750-3 3-8750-2 3-8750-1 16 15 14 13 12 11 10 9 18 17 16 15 14 13 12 11 12 11 10 9 8 7 6 5 White (Temp) Green (Temp) Blue (Iso. Gnd) Brown (mv input) Shield Black (V-) Red (V+) 3-2760-1 3-2760-2 3-2760-11 3-2760-21 Connect this terminal to Earth GND to reduce electrical interference. 6 Signet 2760 DryLoc ph/orp Preamplifier

Wiring from 2760 DryLoc Preamplifier to Other Manufacturer's Equipment The 2760-1/-2 Preamplifier and electrode options may be used with third party equipment if the equipment can process the AMPLIFIED mv signal for ph and is compatible with one of the temperature compensation options. (3 KΩ or PT1000). Refer to the manufacturer's manual for wiring details. Other products may use different terms to identify the function of each conductor. Signet Combination ph Electrodes 3-2724-10 (3 KΩ, NPT) 3-2724-11 (3 KΩ, ISO) 3-2726-10 (3 KΩ, NPT) 3-2726-11 (3 KΩ, ISO) 3-2726-HF-10 (HF Resist, 3 KΩ, NPT) 3-2726-HF-11 (HF Resist, 3 KΩ, ISO) 3-2726-LC-10 (Low Cond, 3 KΩ, NPT) 3-2726-LC-11 (Low Cond, 3 KΩ, ISO) 3-2774 (3 KΩ TC) 3-2776 (3 KΩ TC) Combination ORP (Redox) Electrodes 3-2725-60 (10 KΩ ID, NPT) 3-2725-61 (10 KΩ ID, ISO) 3-2757-WTP (10 KΩ ID) 3-2775 (10 KΩ ID) 3-2777 (10 KΩ ID) DryLoc Preamplifier, Submersible 3-2760-1 3-2760-2 DryLoc Preamplifier, In-Line 3-2760-11 3-2760-21 ittings White (Temperature) Green (Temperature) Blue (mv Reference) Shield (Earth Ground) Black (V-) Red (V+) Brown (Active mv, ph/orp) Differential ph Electrodes 3-2764-1 (3 KΩ RTD) 3-2766-1 (3 KΩ RTD) Differential ORP (Redox) Electrodes 3-2765-1 (10 KΩ ID) 3-2767-1 (10 KΩ ID) Signet 2760 DryLoc ph/orp Preamplifier 7

Ordering Information Mfr. Part No. Code Description 3-2760-1 159 000 939 Submersible Preamplifier with ¾ in. NPT threads and 4.6 m (15 ft) cable 3-2760-2 159 000 940 Submersible Preamplifier with ¾ in. ISO 7/1R threads and 4.6 m (15 ft) cable 3-2760-11 159 001 367 In-line Preamplifier with ¾ in. NPT threads and 4.6 m (15 ft) cable 3-2760-21 159 001 368 In-line Preamplifier with ¾ in. ISO 7/1R threads and 4.6 m (15 ft) cable Accessories and Replacement Parts Calibration Tools 3-2759 159 000 762 ph/orp System Tester (adapter cable sold separately) 3-2759.391 159 000 764 2759 Adapter Cable for use w/2760 DryLoc Preamplifier 3-0700.390 198 864 403 ph Buffer Kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml) 5523-0624 159 000 636 Cable, 6 conductor, 24 AWG shielded 3822-7004 159 001 581 ph 4.01 buffer solution, 1 pint (473 ml) bottle 3822-7007 159 001 582 ph 7.00 buffer solution, 1 pint (473 ml) bottle 3822-7010 159 001 583 ph 10.00 buffer solution, 1 pint (473 ml) bottle 3822-7115 159 001 606 20 gram bottle Quinhydrone for ORP calibration 3-2700.395 159 001 605 Calibration kit: included 3 Polypropylene cups, box as cup stand, 1 pint ph 4.01, 1 pint ph 7.00 Special Request NIST Traceable Certificate Electrodes DryLoc ph Electrodes 3-2724-10 159 001 547 Flat glass ph Electrode, 3 KΩ RTD, ¾ in. NPT or Signet fittings 3-2724-11 159 001 548 Flat glass ph Electrode, 3 KΩ RTD, ISO 7/1 R¾ or Signet fittings 3-2726-10 159 001 555 Bulb glass ph Electrode, 3 KΩ RTD, ¾ in. NPT or Signet fittings 3-2726-11 159 001 556 Bulb glass ph Electrode, 3 KΩ RTD, ISO 7/1 R¾ or Signet fittings 3-2726-HF-10 159 001 551 Bulb glass ph Electrode, 3 KΩ RTD, HF resistant, ¾ in. NPT or Signet fittings 3-2726-HF-11 159 001 552 Bulb glass ph Electrode, 3 KΩ RTD, HF resistant, ISO 7/1 R¾ or Signet fittings 3-2726-LC-10 159 001 559 Bulb glass ph Electrode, 3 KΩ RTD, Low conductivity, ¾ in. NPT or Signet fittings 3-2726-LC-11 159 001 560 Bulb glass ph Electrode, 3 KΩ RTD, Low conduct., ISO 7/1 R¾ or Signet fittings 3-2764-1 159 000 943 Differential ph Electrode, 3 KΩ RTD, 1 in. NPT process connection 3-2766-1 159 000 949 Differential ph Electrode, 3 KΩ RTD, 1 in. NPT process connection 3-2774 159 000 955 Flat glass ph Electrode, 3 KΩ RTD, ¾ in. NPT process connection 3-2776 159 000 959 Flat glass ph Electrode, 3 KΩ RTD, ¾ in. NPT process connection DryLoc ORP (Redox) Electrodes 3-2725-60 159 001 561 Flat ORP Electrode, 10KΩ ID, ¾ in. NPT or Signet installation fittings 3-2725-61 159 001 562 Flat ORP Electrode, 10KΩ ID, ¾ in. ISO 7/1 R¾ or Signet installation fittings 3-2765-1 159 000 946 Differential ORP (Redox) Electrode, 10 KΩ ID, 1 in. NPT process connection 3-2767-1 159 000 952 Differential ORP (Redox) Electrode, 10 KΩ ID, 1 in. NPT process connection 3-2775 159 000 957 Flat ORP (Redox) Electrode, 10 KΩ ID, ¾ in. NPT process connection 3-2777 159 000 961 Bulb ORP (Redox) Electrode, 10 KΩ ID, ¾ in. NPT process connection 3-2757-WTP 159 001 391 Flat, Wet-Tap ORP electrode, 10 KΩ ID Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 For Worldwide Sales and Service, visit our website: www.gfsignet.com Or call (in the U.S.): (800) 854-4090 For the most up-to date information, please refer to our website at www.gfsignet.com 3-2760.090 Rev. 9 01/18 English Georg Fischer Signet LLC 2018 8 Signet 2760 DryLoc ph/orp Preamplifier