RANGE HOODS USER INSTRUCTIONS

Similar documents
HBC-20 - LED HIGH BAY

Penguin Gentoo 600B Cordless Sprayer User s Manual

Installation Instructions

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

User s Manual and Operating Instructions

Installation Instructions

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

PowerFLEX Module Limited Warranty Program

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SUNTURA SOLAR TRACKER

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Power. On Your Terms.

Installation Instructions

Veterinary Anesthesia Gas Scavenging System (Active)

Installation Instructions

SUNTURA HD SOLAR TRACKER

Chef Under-Cabinet 30 & 36

ActuLink ABS Module - ABS-MOD-400

INSTALLATION INSTRUCTION & OWNER S MANUAL

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation Instructions

Installation Instructions

10 Year Limited Warranty

User s Manual and Operating Instructions

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Installation & Operators Manual

PVI 60KW, PVI 82KW, PVI 95KW

Straight-Bore Clutch LSCC-32, 44, 54

HR-20P Pneumatically Controlled Pressure Regulator

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Remote Vehicle Control System CA-150. Owner's Manual. Vehicle Security System With Remote Keyless Entry

MaxLite LED Enclosed & Sealed Jelly Jars

Installation Instructions

LED LARGE WALL PACK (CUTOFF & STANDARD)

WiFi Tank Level Monitor Installation Instructions

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

Installation manual. Replacement front sway bar end link Dodge Ram Dodge Ram 1500 Part # 30927

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

Table of Contents. Page 2. midlandusa.com. Model PPG100

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

ATD-7384W 12-Ton Bottle Jack Owner s Manual

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

INSTALLATION, MAINTENANCE & SERVICE MANUAL

Charging with AC (wall) Charger

StormPro BA Series Sump Pump

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved

SOLAR DASH CHARGING SYSTEM USER GUIDE

Railway. assembly instructions. data and power solution. model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY

20250 Module Installation Guide

Rig Master Power by Mobile Thermo Systems Inc.

CAUTION: Read manual carefully for proper procedures and operation.

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Remote Vehicle Control System. Keyless Entry and Convenience System

END USER TERMS OF USE

Users Guide for Ac-sync

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

INSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05

Harvil 4 Foot Air Hockey Table

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

Model A Turn Signal Kit Installation Guide

Air Compressor. Owner s Manual

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

General Guidelines. Instructions for Part # SC-SWING-AWAY-V2. Safety

Female Plug. connecting to Fuel Quantity

INSTALLATION AND OPERATION MANUAL

OPERATING MANUAL 18V Ni-Cd Battery Pack

3-Way Diverter Valve Trim Acabado De Diversora Garniture De Dérivation

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

MPG526-L Kayak Stacker Instructions

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

RECYCOIL Used Oil Tank

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

NUTONE RANGE HOOD NTM SERIES

2-DOOR LAUNDRY CABINET KIT

Digital Clock model 75100C

Installation Instructions Roughrider Tailgate Shelf

3-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

ValveSentry USER S MANUAL PLEASE READ CAREFULLY AND SAVE

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Transcription:

RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions for future reference. 06/03/2014 MA1214-1

GENERAL INSTALLATION INSTRUCTIONS A: GENERAL Carefully unpack the hood but do not remove any protective film until after installation to avoid accidental damage or scratching. Place filters somewhere safe for the same reason. Check for damage, and lay out the hood pieces and parts. Range hoods do not come with wall or ceiling screws, as the type of structure determines the type of screws. Check that you have the right tools. In addition to marking and measuring tools, a hammer, screwdrivers, pliers and scissors, you may need sheet metal sheers, and wire strippers. Safety glasses are recommended. B: ELECTRICAL CONNECTION This range hood must be grounded. If the dwelling wiring is not 2-wire with a ground wire, a ground must be provided by the installer. Install a 5.08 X 10.16 cm (2 X 4 ) wall outlet box and 3-blade 125 Volts, 15 amp grounded receptacle. Use wire nuts to connect incoming ground, neutral and hot. Push wires into the junction box and replace cover. Be sure wires are not pinched. C- INSTALLATION DISTANCE Hood should be placed at a minimum distance from the range top of: 61 cm (24 ) for electric cooking surface 76 cm (30 ) for Gas Cooking Surface UNDERCABINET RANGE HOOD INSTALLATION This range hood model is designed to be installed under kitchen cabinets. If replacing a different model, check the location of the air exhaust in case it does not line up with the new model; The ducting location may have to be adjusted to the existing wall opening; If the ventilation system is equipped with an external air duct with a different diameter, apply a reduction fitting. A 6 Ø or rectangular 3 X 10 ducting is recommended for maximum performance and safety. Section A: Select venting option This unit offers 2 venting options: A- Top venting (vertical) using 6 round or rectangular 3 X 10 damper B- Rear venting (horizontal) using rectangular damper. A1- Top venting Roof Exhaust A2- Top venting Wall Exhaust B- Rear Venting 5

A- Top venting using 6 round damper: - If you require 6 round venting, keep the unit as provided in the packaging and install the round damper provided; - Position the damper on top of the unit and set in place with screws provided (See Pic 1 a, b, c) - Connect duct work to damper - Use Duct Tape to ensure joint is sealed and air tight Pic 1 A- Top venting using rectangular damper - If you require rectangular top (vertical) venting simply install the rectangular damper provided (See pic 2) - Connect duct work to damper - Use Duct Tape to ensure joint is sealed and air tight Pic 2 6

B- Rear venting (horizontal) using rectangular damper Step 1: Prepare Range Hood - Remove unit from packaging - Position the unit on its back on a flat non abrasive surface - front facing you (See pic 3) - Remove the 2 filters to allow access to the inside of the unit (See Pic 3) - Cut tie wraps so wires are free to move and be relocated (See Pic 4) Pic 3 Pic 4 Step 2: Remove rear vent back plate (See Pic 5) - Position the unit face down on a flat non abrasive surface - rear of product facing you - Remove the back plate by removing the 4 screws Pic 5 7

Step 3: Relocate motor exhaust at the rear of unit - Position the unit on its back on a flat non abrasive surface perpendicular to your working surface (See Pic 6) - Place hand to hold motor in position and ensure weight of motor is well supported (See Pic 6) o This will ensure screws don t get bent or broken - Remove 4 screws that hold motor in place on the top side of the hood o Ensure the motor weight is well supported by your hand as the last screw in place may break under the weight of the motor - Once the motor is set free from the hood, rotate motor clock wise to position venting outlet with rear rectangular hole, ensuring that: o Electric wire is located under the motor as you relocate the motor outlet (See Pic 7) o Electric wire is not caught under the motor outlet (See Pic 8) o 4 holes are aligned with screw holes at the rear - Put unit upside down so the screw holes securing the motor are in a position facing you - Install 4 screws to hold motor Use a screw driver to perform operation NOT A DRILL as it may strip the motor housing thread (See Pic 9) Pic 6 Pic 7 Pic 8 Pic 9 8

Step 4: Install top vent plate and rear damper - Re-install the plate removed in step 2 to block top venting hole o Put plate in position and put in 4 screws from step 2 (See Pic 10) - Install rectangular air damper outlet on the rear vent location (See Pic 11) - Connect duct work to damper - Use Duct Tape to ensure joint is sealed and air tight Pic 10 Pic 11 9

6½" (165 mm) 9¼" (235 mm) and 36 (900mm) width. 27⅞" (708 mm) 7¼" (185 mm) ½" (90 mm) 1¹/8" (28 mm) 1½" (38 mm) 7¼" (185 mm) 27 / " (708 mm) or 33 3/8 (848 mm) 7 8 4¼" (108 mm) 11" (280 mm) 27 7/8 " (708 mm) or 33 3/8 (848 mm)

6½" (165 mm) 4¼" (108 mm) 9¼" (235 mm) 9¼" (235 mm) and 36 (900mm) width. 7¼" (185 mm) 1¹/8" (28 mm) 1½" (38 mm) 7¼" (185 mm) 27 7/8 " (708 mm) or 33 3/8 (848 mm) top 1¹/8" (28 mm) 1½" (38 mm) 7¼" (185 mm) 11" (280 mm) 27 7/8 " (708 mm) or 33 3/8 (848 mm)

LIMITED PRODUCT WARRANTY Subject to the limitations, exclusions and disclaimers hereof, AMS warrants exclusively to the original purchaser (the Purchaser ) of this Ancona Range hood product (the Product ) that it shall be free from defects in material or workmanship (the Limited Product Warranty ). The duration of the Limited Product Warranty is 12 months from the date of original purchase (the Warranty Period ). The Limited Product Warranty does not extend to commercial or institutional use or installation and to residential or domestic use or installation outside of Canada and the USA. It is not transferable or assignable to any person. Any failure of the Product that is not traceable to a defect in material or workmanship is not covered by the Limited Product Warranty. These non-warrantable items include, but are not limited to: (i) consumable and accessory parts; such as light bulbs or filters; (ii) service outside of Canada and the USA; (iii) damage caused during shipping, handling or installation; (iv) labour costs related to installation, removal, reinstallation costs or other contingent expense; or (v) routine replacement of parts due to normal wear and tear of the Product. If the Purchaser discovers within the Warranty Period a defect in material or workmanship, the Purchaser shall promptly notify AMS in accordance with the Warranty Claim Procedure set forth below. Within a reasonable time after such notification, AMS shall, at no charge to the Purchaser: (i) perform any repair or replacement of parts that it determines is necessary or useful to correct any defect in material or workmanship; or (ii) replace the original Product with a new Product, the whole at AMS sole and absolute discretion. The remedy provided above shall be the Purchaser s sole and exclusive remedy and AMS' sole and exclusive obligation under the Limited Product Warranty. Products or parts that are new or reconditioned to perform as new, shall be exchanged by AMS upon receipt of the original Product or parts from the Purchaser and, upon the completion of such exchange, the original Product or parts shall become AMS property. The Warranty Period shall not be extended due to suspension of the use of the Product because of repair, replacement, examination or for any other reason. Subject to the Purchaser s compliance with the Warranty Claim Procedure set forth below, transportation and installation of warranty replacements shall be performed at AMS cost, and AMS shall bear the risk of loss or damage to returned Product or parts while in transit. AMS Limited Product Warranty shall be automatically void if: (i) any repair, alteration, modification, customization, disassembling, addition or any other work is performed on the Product by any person not authorized by AMS to do so; (ii) any alleged material defect, including deterioration or wear, is a result of failure to observe the manufacturer s instructions or guidelines, abuse, misuse, improper operation, care or maintenance, unusual physical or electrical stress and/or power surges, brown-out, chemical abrasion or improper chemical or environmental conditions, leaking, fire, lightning, force majeure or superior force, accident, error, negligence, or is a result of use for nondomestic or non-residential purposes or for any purpose other than the Product s intended purpose; (iii) the Product is operated in conjunction with accessories, other products, ancillaries or peripheral equipments or substances that have not been previously approved in writing or validated by AMS; or (iv) Purchaser fails to comply with the Warranty Claim Procedure set forth below. THE LIMITED PRODUCT WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS OF ANY KIND, MADE OR INTENDED BY AMS OR ITS AUTHORIZED DISTRIBUTORS. IN NO EVENT SHALL AMS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE PAID BY THE PURCHASER FOR THE PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR OTHER SIMILAR DAMAGES, WHETHER FORESEEABLE OR UNFORESEEABLE, ARISING OUT OF OR IN CONNECTION WITH THE USE OF THE PRODUCT, INCLUDING THE ABILITY OR THE INABILITY TO USE THE PRODUCT. The terms hereof and any action in connection therewith, regardless of form, shall be interpreted and construed in accordance with the laws of the Province of Québec and the laws of Canada applicable therein, without giving effect to principles of conflicts of laws. If a provision of this Limited Product Warranty is determined to be invalid, illegal or unenforceable, all other provisions will remain in full force and effect. WARRANTY CLAIM PROCEDURE In the event a claimable defect occurs, the Purchaser shall call AMS customer service department at 1-800-350-4562 in order to obtain a return authorization number and shipping instructions (the Authorized Shipping Instructions ). The Purchaser shall then promptly ship the Product, in accordance with the Authorized Shipping Instructions with the following documentation/information: the name and address of the Purchaser; the Product model number; the date and location of the purchase of the Product; the original sales receipt of the Product; the complete description of the problem; the name and address of the installer of the Product. Claims must be filled out in writing and received by AMS within six months of the appearance of the claimable defect. For service and assistance, please call: 1-800-350-4562, or email us at: info@anconahoods.com