High Current Solutions High Current Devices

Similar documents
Customized switching solutions High current solutions

Plug-in relays Mini ISO relays

Twin coil relays TCR and TCR-F. Chassis Systems. Conditions

Twin relays. Twin coil relays TCR and TCR-F. Convenience. Powertrain Systems. Safety Security Body Driver Information.

Automotive Relays Plug-in Mini ISO Relays. Power Relay F4

Automotive Relays PCB Single Relays. Micro Relay K (THT THR)

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7

1 Form A 5A small size power relay for interface

40 Series - Miniature PCB relays A. Features

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Ordering Information. Text PCB Power Relay G5LE

AXICOM Telecom-, Signal and RF Relays. W11 Relay V Nov. 07 Rev. C ECOC: JM10

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

Latching SPST EPIC Sealed Contactor Amp Power Switching RoHS Compliant, all date codes

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

2c 15A, 4c 10A polarized power relays

Miniature Intermediate Power Relay HY

Type List. Standard Type. High Power Type

COMPACT FLAT SIZE FOR AUTOMOTIVE

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Electronic Pressure Switches

COMPACT FLAT SIZE FOR AUTOMOTIVE

TV-5, TV-8 rated 10mm flat power relays Silent type is available

MIDDLE LOAD RELAY FOR SMART J/B

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Features. Type List. Enclosure style. Terminal style. Contact. Sealed type washable. form Dust cover Flux tight

5 mm contact pin pitch PCB or 95 series sockets

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

XMC0 Series. Definite Purpose Contactors

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Miniature General Purpose Relay HY

Relays Micro relays. Characteristic quantities. 6 Relays

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

Capacitor Switching Contactors Type K3...-A, K3...-K

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Thermal Overcurrent Circuit Breaker 3120-F...

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Emergency lighting units EM converterled

General Purpose Relay

XMC0 Series DEFINITE PURPOSE CONTACTORS

Model Number Structure

Features. Type List A

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

HS1L Interlock Switches with Solenoid

Emergency lighting units EM converterled

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Magnetic and Hydraulic-Magnetic Circuit Breaker

Features. Type List 832A

CRS-A Series High Power Anti-Surge Resistor

AF40... AF96 3-pole contactors Technical data

55 Series - Miniature General Purpose Relays 5-10 A

Aluminum Capacitors Power High Ripple Current Screw Terminals

General Purpose Low Power PCB Relays

EStrong-series Emergency Stop

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

RUC industrial relays of small dimensions

3M CP2 Press-Fit Headers and Sockets, 2 mm

CI-TI Contactors and motor starters Types CI 61 - CI 98

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

6mm and 14mm Slim Interface Relay

HS5E Miniature Interlock Switches with Solenoid

Thermal Overcurrent Circuit Breaker 3120-F...

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Thermal Overcurrent Circuit Breaker 3120-F...

Semiconductor Fuses Microswitches & Studs

SG-B1 SERIES / SG-A1 SERIES

P-Series 11 to to to to to to to 1100 >1000 <25

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Ordering Information. Text Surface-Mounting Signal Relay G6K

3RT14 Contactors with 3 Main Contacts

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Thermal Overcurrent Circuit Breaker 3120-F...

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Model Number Structure

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

T75S5D Product Details

6mm Interface Relays RV8 Series

2 pole 10 A PCB mount A1 A

Transcription:

Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features - Switches currents of more than 300 A - Heat, moisture and vibration resistant - Minimal contact resistance Typical Applications - Preheating air for diesel engines - Preheating catalytic converters - Car heating systems - Electrical power steering - Electrical pumps - Primary and/or engine switches - Electrical valve control - Switches for loading ramps - Electrically adjustable camshaft - Dual battery switches - Battery disconnection - Also available for 42 V applications - ELV/RoHS/WEEE compliant Please contact Tyco Electronics for relay application support. Design Dustproof; optional: sealed version, sealing in accordance with IEC 68; immersion cleanable: protection class IP67 to IEC 529 (EN 60 529) Weight Approx. 220 g (7.76 oz.) Nominal voltage 12 V or 24 V; other nominal voltages available on request Terminals Quick connect terminals (coil) Screw terminals (load) Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions unless otherwise noted: 23 C ambient temperature, 20-50% RH, 29.5 ± 1.0" Hg (998.9 ±33.9 hpa). Please also refer to the Application Recommendations in this catalog for general precautions. For general precautions please refer to our Application Notes and especially to Storage in the Glossary at http://relays.tycoelectronics.com/appnotes/ 132_3d01 Car Industry Truck Industry Other Industry Disclaimer All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco are reserved. 178

Dimensional Drawing Double make/make version 7.5 x 6.5 3.307 (84) 2.48 (63) 1.575 (40) Assembly Torque 3.8 ±0.4 Nm.531 (13.5) Ø.256 (6.5) 2.795 (71) 1.772 (45) 2.567 (65.2) Connector 2-pole Screw terminals M6 Tyco1666-X View of the Terminal (bottom view).610 (15.5) Connector Information AMP Superseal 1.5. series Coil side - Receptacle connector 282080-1 - Single wire seal 281934-2 - Contact 282110-1 Load side - Thimble 710026 ECR1667-6 Changeover Version.531 (13.5) 2.185 (55.5).177 (4.5) 1.575 (40).413 (10.5).276 (7) Quick connectors similar to ISO 8092-1.079 (2).413 (10.5) 2.008 (51) Screw terminals M6 1.772 (45) 2.519 (64) Tyco1452-F View of the Terminal (bottom view).394 (10) 2.48 (63).610 (15.5).551 (14) ECR1453-N 179

Contact Data Contact configuration Make contact/ Double make contact/ Changeover contact/ Form A Form X Form C Circuit symbol (see also Pin Assignment) Rated voltage 12 V 12 V 24 V 24 V 12 V 12 V Rated current at 85 C NC/NO NC/NO Cable 16 mm 3 130 A 120 A 120 A 100 A 100 A/130 A 90 A/120 A Cable 25 mm 3 150 A 130 A 135 A 120 A 120 A/150 A 100 A/130 A Contact material AgNi0.15 AgSnO2 AgNi0.15 AgSnO2 AgNi0.15 AgSnO2 Max. switching current 1) NC/NO NC/NO On 2) 150 A 300 A 150 A 300 A 120 A/150 A 200 A/300 A Off 150 A 300 A 150 A 300 A 120 A/150 A 200 A/300 A Min. recommended load 3) 1 A at 5 V Voltage drop at 100 A (initial) NO contact Typ. 50 mv, Typ. 70 mv, Typ. 70 mv, Typ. 70 mv, Typ. 50 mv, Typ. 70 mv, 100 mv max. 200 mv max. 200 mv max. 400 mv max. 100 mv max. 200 mv max. NC contact Typ. 50 mv, Typ. 70 mv, 100 mv max. 200 mv max. Mechanical endurance (without load) > 10 7 operations Electrical endurance at 23 C, 1 s on, 5 s off > 3 x 10 4 > 5 x 10 4 > 1 x 10 4 > 5 x 10 4 (example of resistive load) operations operations operations operations Data on request 150 A, 13.5 V 300 A, 13.5 V 150 A, 27 V 200 A, 27 V Max switching rate at nominal load 6 operations per minute (0.1 Hz) 1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages. 2) For a load current duration of maximum 3 s for a make/break ratio of 1:10. 3) See chapter Diagnostics in our Application Recommendations on page 18 of this catalog or consult the internet at http://relays.tycoelectronics.com/application.asp Operating Voltage Range 300 ECR1449-V Does not take into account the temperature rise due to the contact current E = pre-energization Pin Assignment 1 make contact/ 1 double make contact/ 1 changeover contact/ 1 form A 1 form X 1 form C 180 1 3 5 2 ECR1669-M 1 3 5 2 ECR1668-E 1 3 4 5 2 ECR1455-5

Coil Data Available for nominal voltages 12, 24 V (other coils on request) Nominal power consumption of the unsuppressed coil at nominal voltage 3.3 W Nominal power consumption at nominal voltage with suppression resistor 4.1 W Test voltage winding/contact 1000 VACrms Maximum ambient temperature range 40 to + 125 C Operate time at nominal voltage Typ. 25 ms Release time at nominal voltage Typ. 8 ms N.B. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Mechanical Data Cover retention Axial force Pull force Push force Terminals Pull force 150 N (33.75 lbs) Push force 150 N (33.75 lbs) Resistance to bending, force applied to front 20 N (4.5 lbs) 1) Resistance to bending, force applied to side 20 N (4.5 lbs) 1) Max. torsion of screw bolts 4... 5 Nm Enclosures Dust cover Protects relay from dust. For use in passenger compartment or enclosures. Please refer to the Application Notes at http://relays.tycoelectronics.com/appnotes/ 1) Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm. Environmental Conditions Temperature range, storage Refer to Storage in the Glossary at http://relays.tycoelectronics.com/appnotes/ Test Relevant standard Testing as per Dimension Comments Temperature cycling IEC 68-2-14 Nb 10 cycles 40/+ 85 C (5 C per min.) Dry heat IEC 68-2-2 Ba 500 h 100 C Damp heat constant IEC 68-2-3 Ca 500 h 40 C, 93% RH Industrial atmosphere IEC 68-2-60 Method 4 21 days 25 C Corrosive gas IEC 68-2-42 10 ± 2 cm 3 /m 3 SO2 10 days IEC 68-2-43 1 ± 0.3 cm 3 /m 3 H2S 10 days Vibration resistance IEC 68-2-6 (sine sweep) 10 200 Hz No change in the 5 g switching state > 10 μs Shock resistance IEC 68-2-27 (half-sine pulse form) 6 ms Valid for NC contacts, min. 20 g NO contact values significantly higher Load dump ISO 7637-1 (12 V) Test pulse 5 Vs =+ 86.5 V ISO 7637-2 (24 V) Test pulse 5 Vs =+ 200 V Drop test Capable of meeting specifications after 1.0 m (3.28 foot) drop onto concrete Flammability UL94-HB or better (meets FMVSS 302) 1) 1) FMVSS: Federal Motor Vehicle Safety Standard. 181

Ordering Information Part Numbers (see table below for coil data) Nominal Contact Contact Protection Class according to Relay Part Number Tyco Order Number Voltage Arrangement Material IEC 529 (EN 60 529 ) 12 V HCR 150 V23132-A2001-A100 0-1393315-1 12 V 1 Form A AgNi0.15 IP54 V23132-A2001-A200 0-1393315-2 12 V 1 Form A AgSnO2 IP54 V23132-A2001-B100 0-1393315-3 12 V 1 Form A AgNi0.15 IP67 V23132-A2001-B200 0-1416010-1 12 V 1 Form A AgSnO2 IP67 24 V HCR 150 V23132-B2002-A100 0-1393315-8 24 V 1 Form X AgNi0.15 IP54 V23132-B2002-A200 0-1393315-9 24 V 1 Form X AgSnO2 IP54 V23132-B2002-B100 1-1414428-0 24 V 1 Form X AgNi0.15 IP67 V23132-B2002-B200 1-1393315-1 24 V 1 Form X AgSnO2 IP67 12 V HCR 150 V23132-C2001-A100 1-1393315-2 12 V 1 Form C AgNi0.15 IP54 V23132-C2001-A200 0-1416010-3 12 V 1 Form C AgSnO2 IP54 Coil Versions Coil Resistance Must Must Allowable Overdrive 1) Coil Rated Coil (Ω) Operate Release Voltage (V) data for Voltage without suppression with suppression Voltage Voltage HCR 150 (V) device device (V) (V) at 23 C at 85 C V23132-**001-**** 12 44 37 7.2 1.2 27 20 V23132-**002-**** 24 178 141 14.4 2.4 54 38 1) Allowable overdrive is stated with no load applied and minimum coil resistance. 182