Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Similar documents
Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Micro Contactor MA Series

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Low voltage switch gear

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

General Catalogue. Quality made in D946E173

Contactors Motor-Starters D677E121

Contactors RAST 5 D778E131

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

CI-TI Contactors and motor starters Types CI 61 - CI 98

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

Capacitor Switching Contactors Type K3...-A, K3...-K

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Contactor Types CI 61-98

3RT14 Contactors with 3 Main Contacts

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Mini Contactors CI 4-

22AF 40AF AF 150AF 225AF 400AF 800AF

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Modular Contactors and Switches D681E121

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Application Mini Contactors for Motors and Resistive Loads

ASL09..S 3-pole Contactors - Spring Terminals

Industrial Contactors CTX 3 3P 185A - 800A

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF40... AF96 3-pole contactors Technical data

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

4 - Miniature controls

Ktec Contactors and thermal overloads

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Bulletin 825 SMM Smart Motor Manager

Technical Information

Modular contactor for installation into distribution boards

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Technical Information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Power Contactor with Mirror Contacts

3 - Protection components Motor circuit-breakers

Switches Unlimited Phone: * Fax:

Selection Guide Motor Control Device Solutions

Page 2-4 Page 2-8. Page Page 2-13

CI-TI Contactors and Motor Starters Type CI 6-50

General Informations 2 Technical data 3 Basic designs 4-8

3VU13, 3VU16 Circuit-Breakers

Meta Solution. Contactors and Overload relays

Technical Information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Controls. CONTACTORS CWB Line (up to 40A)

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Bulletin 100-D IEC Contactors

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Manual Motor Starters. Meta-MEC

Short form catalogue. Motor protection & control

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

55 Series - Miniature General Purpose Relays 5-10 A

Bulletin 193-T1 Bimetallic Overload Relays

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Application Mini Contactors for Motors and Resistive Loads

5 mm contact pin pitch PCB or 95 series sockets

Essential equipment for all your requirements

Description. Positive safety relays

Contactor Relays 3TH30

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Motor Protection Circuit Breakers 3VU13 and 3VU16

Star Series Motor protection & control

Industrial contactors CTX-1

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

General_technical_data Series

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Model Number Structure

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

AF series contactors (9 2650)

Thermal overload relay TF65 and TF96

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Electronic overload relay EF65, EF96 and EF146

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Transcription:

Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC and DC coil) Auxiliary contacts suitable for electronic devices (DIN 19240) Finger proof (BGV A2) Accessories 2 and 4 pole additional auxiliary contacts in different configurations Mechanical interlock (in reversing contactor combination only) RC Suppressors Link modules for fuseless Load Feeders Insulated wiring systems (parallel, Star-delta combinations) Approved Standards Standard Standard Guide No (US,C) UL VDE 0660 NLDX, NLDX7 ICE 947-5-1 EN 60947-5-1 Ordering Information Model Number Legend 48VS: DC48V with diode 110VS: DC110V with diode 125VS: DC125V with diode 1. 2. Aux. Contact Modules for J7KNA-##-## ##### 1 2 3 4 J73KN-##-## 1) Mini Contactor 2) Rated Motor Current (AC3 ) 09: 9A 12: 12A 3) Integrated auxiliary contact 10: 1 NC 0 NC 01: 0 NO 1NC 4: 4 main pole type (no aux contact) 4) R: Reversing Contactor 5) Coil voltage (AC operated) 1) 24: AC24V 50/60Hz 48: AC48V 50Hz 60: AC60V 50Hz 110: AC110-115V 50Hz, AC120-125V 60Hz 180: AC180-210V 50Hz, AC200-240V 60Hz 230: AC220-230V 50Hz, AC240V 60Hz 240: AC230V-240V 50Hz 400: AC380-50Hz, AC440V 60Hz 415: AC400-415V 50Hz Coil voltage (DC operated) 24D: DC24V 48D: DC48V 60D: DC60V 110D: DC110V 24VS: DC24V with diode 1) See datasheet J7KN Motor Contactor for RC-suppressor units. 1 2 3 1) Auxiliary Contact Modules 2) A: for mini motor contactor (DIN EN 50005) AM: for mini motor contactor (DIN EN 50012) 3) Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 04: 0 NO 4 NC 22: 2 NO 2 NC 40: 4 NO 0 NC 4) for Reversing Contactors v: left side x: right side 3. Insulated wiring systems for motor contactors J74-WKR-A 1 2 3 1) Additional reference for LVSG 2) WKR: Wiring Kit Reverser 3) Version 4. Accessories for mini motor contactors/ contactor relays (RC suppressor units) J74KN-D-RC## 1 2 3 4 1) Additional reference for LVSG 2) D: J7KNA(-AR) 3) RC = RC suppressor unit 4) Voltage Mini Motor Contactor J7KNA 1

System overview AC Operated Ratings Rated Current Aux. Contacts Type Pack Weight AC2, AC3 AC3 AC1 380V 415V 500V 660V A A NO NC Suitable Overload Relay *1 Coil Voltage *2 24 24V 50/60Hz 230 220-230V 50Hz pcs. kg/pc. 4 4 4 9 20 1 - J7TKN-A J7KNA-09-10-##### 10 0.16 5.5 5.5 5.5 12 20 1 - J7TKN-A J7KNA-12-10-##### 10 0.16 4 4 4 9 20-1 J7TKN-A J7KNA-09-01-##### 10 0.16 5.5 5.5 5.5 12 20-1 J7TKN-A J7KNA-12-01-##### 10 0.16 4-pole, With Screw Terminals 4 4 4 9 20 - - J7TKN-A J7KNA-09-4-##### 10 0.19 *1) For details see datasheet J7TKN Thermal Overload Relay *2) Other coil voltages see page 6 DC Solenoid Operated Ratings Rated Current Aux. Contacts Type Pack Weight AC2, AC3 AC3 AC1 380V 415V 500V 660V A A NO NC Suitable Overload Relay *1 Coil voltage 24V DC 2,5W pcs. kg/pc. 4 4 4 9 20 1 - J7TKN-A J7KNA-09-10-###D(-VS) *2 10 0.19 5.5 5.5 5.5 12 20 1 - J7TKN-A J7KNA-12-10-###D(-VS) *2 10 0.19 4 4 4 9 20-1 J7TKN-A J7KNA-09-01-###D(-VS) *2 10 0.19 5.5 5.5 5.5 12 20-1 J7TKN-A J7KNA-12-01-###D(-VS) *2 10 0.19 *1) For details see datasheet J7TKN Thermal Overload Relay *2) with built-in coil suppressor (diode + zener diode) Auxiliary contact blocks with screw terminals for contactors J7KNA-09 and J7KNA-12 Contacts Rated Current Thermal Rated Current Type Pack Weight AC15 NO NC 230V A A A pcs. kg/pc. 1 1 3 2 10 J73KN-AM-11 10 0.04-2 3 2 10 J73KN-AM-02 10 0.04 2 2 3 2 10 J73KN-AM-22 10 0.04 Link modules for electric connection between MPCB and contactors Description Version for contactors For MPCB Type Pack pcs Weight approx. kg/pc link module (electrical and mechanical connection) See datasheet J7MN Motor Protection Circuit Breaker J7KNA 09-12 J7MN 12 / J7MN 25 J74MN-VK1 12-25 1 0.015 2 Mini Motor Contactor J7KNA

Suppressor units Function For Contactors Voltages Partnumber Type RC-Unit snap on J7KNA(-AR) 12-48 V AC/DC 48-127 V AC/DC 110-250 V AC/DC J74KN-D-RC24 J74KN-D-RC110 J74KN-D-RC230 Mini Motor Contactor J7KNA 3

System overview AC Operated Wiring Diagrams Auxiliary Contact Blocks Contactor with Auxiliary Contact Distinc. Number according to DIN EN 50012 Type NO NC 10 01 4-pole, With Screw Terminals A1 A2 1 2 3 4 5 6 7 8 00 Block Distinc. Number according to DIN EN 50012 NO NC J73KN-AM-11 1 1 21 2 1 J73KN-AM-02 0 2 12 1 2 J73KN-AM-22 2 2 32 3 2 J73KN-A-11 1 1-1 2 J73KN-A-02 0 2-0 3 J73KN-A-40 4 0-4 1 J73KN-A-22 2 2-2 3 J73KN-A-04 0 4-0 5 J73KN-A-11 1 1-1 1 J73KN-A-02 0 2-0 2 J73KN-A-40 4 0-4 0 J73KN-A-22 2 2-2 2 J73KN-A-04 0 4-0 4 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts Prefered combinations according to DIN EN 50012 Contacts according to DINEN50005 Contacts according to DINEN50005 DC Solenoid Operated Wiring Diagrams Auxiliary Contact Blocks Contactor with Auxiliary Contact Distinc. Number according to DIN EN 50012 Type NO NC A1 A2 A1 A2 ( ) = VS-Version 1 2 1 2 3 4 3 4 5 13 6 14 5 21 6 22 10 01 Block Distinc. Number according to DIN EN 50012 NO NC J73KN-AM-11 1 1 21 2 1 J73KN-AM-02 0 2 12 1 2 J73KN-AM-22 2 2 32 3 2 J73KN-A-11 1 1-1 2 J73KN-A-02 0 2-0 3 J73KN-A-40 4 0-4 1 J73KN-A-22 2 2-2 3 J73KN-A-04 0 4-0 5 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts Prefered combinations according to DIN EN 50012 Contacts according to DINEN50005 Auxiliary contact blocks with screw terminals for contactors J7KNA-09 and J7KNA-12 Wiring Diagrams J73KN-AM-11 J73KN-AM-02 J73KN-AM-22 J73KN-A-11 J73KN-A-02 J73KN-A-40 J73KN-A-22 J73KN-A-04 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts 4 Mini Motor Contactor J7KNA

System overview Mini Reversing Contactors, Mechanical Interlocked AC Operated Ratings Rated Current Aux. Contacts Type Pack Weight AC2, AC3 AC3 AC1 380V 415V 500V 660V A A NO NC Suitable Overload Relay *1 Coil Voltage *2 24 24V 50/60Hz 230 220-230V 50Hz pcs. kg/pc. 4 4 4 9 20-1 J7TKN-A J7KNA-09-01-R-##### 1 0.32 5.5 5.5 5.5 12 20-1 J7TKN-A J7KNA-12-01-R-##### 1 0.32 *1) For details see datasheet J7TKN Thermal Overload Relay *2) Other coil voltages see page 6 DC Solenoid Operated Ratings Rated Current Aux. Contacts Type Pack Weight AC2, AC3 AC3 AC1 380V 415V 500V 660V A A NO NC Suitable Overload Relay *1 Coil voltage 24V DC 2,5W pcs. kg/pc. 4 4 4 9 20-1 J7TKN-A J7KNA-09-01-R-###D(-VS) *2 1 0.38 5.5 5.5 5.5 12 20-1 J7TKN-A J7KNA-12-01-R-###D(-VS) *2 1 0.38 *1) For details see datasheet J7TKN Thermal Overload Relay *2) with built-in coil suppressor (diode + zener diode) Auxiliary contact blocks with screw terminals for contactors J7KNA-09-01-R (D) and J7KNA-12-01-R (D) Contacts Rated Current Thermal Rated Current Type Pack Weight AC15 NO NC 230V A A A pcs. kg/pc. 1 1 3 2 10 J73KN-AM-11V 10 0.04 1 1 3 2 10 J73KN-AM-11X 10 0.04 Insulated wiring systems for contactors J7KNA-09-01-R (D) and J7KNA-12-01-R (D) Description Reversing Starter Connector with Coil Connector for Mini Reversing Contactors, mechanical interlocked Version (A) 16 J7KNA-09-01-R (D) & J7KNA-12-01-R (D) For contactors Type Pack pcs J74-WKR-A 1 Mini Motor Contactor J7KNA 5

System overview AC/DC solenoid operated Wiring Diagrams Distinc. Number according to DIN EN 50012 Auxiliary Contact Blocks suitable for left hand side Contactor K1 Type NO NC right hand side Contactor K2 Type NO NC J73KN-AM-11V 1 1 J73KN-AM-11X 1 1 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts 01 Auxiliary contact blocks with screw terminals for contactors J7KNA-09-01-R (D) and J7KNA-12-01-R (D) Wiring Diagrams J73KN-AM-11V J73KN-AM-11X 13 31 31 13 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts 14 32 32 14 Specifications Coil Voltages Suffix Voltage Marking Rated Control Voltage U s to contactor type range for e.g. at the coil 50Hz 60Hz J7KNA-09-10-24 for 50Hz V for 60Hz V min V. max V. min V. max V. 24 24 24 22 24 24 24 48 48 48 48 50 48 52 100 100 110-115 100 105 110 115 110 110-115 120-125 110 115 120 125 200 200 210-220 195 205 210 220 230 220-230 240 220 230 240 250 400 380-400 440 380 400 415 440 550 525-550 600 525 550 570 600 Standard voltages in bold type letters. Coil not exchangeable Please see datasheet J7KN Motor Contactor for RC-suppressor units. 6 Mini Motor Contactor J7KNA

Engineering data and Characteristics Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type J7KNA-09- J7KNA-12- Rated insulation voltage U i V AC 690 *1) 690 1) Making capacity I eff at U e = AC A 165 165 Breaking capacity I eff AC A 100 100 cos = 0,65 500V AC A 90 90 AC A 80 80 Utilization category AC1 Switching of resistive load Rated operational current I e (=I th ) at 40 C, open A 20 20 Rated operational power of three-phase resistive loads 230V 7.9 7.9 50-60Hz, cos = 1 240V 8.3 8.3 13.8 13.8 415V 14.3 14.3 Rated operational current I e (=I the ) at 60 C, enclosed A 16 16 Rated operational power of three-phase resistive loads 230V 6.3 6.3 50-60Hz, cos = 1 240V 6.7 6.7 11 11 415V 11.5 11.5 Minimum cross-section of conductor at load with I e (=I th ) mm² 2.5 2.5 Utilization category AC2 and AC3 Switching of three-phase motors Rated operational current I e 220V A 12 15 open and enclosed 230V A 11.5 14.5 240V A 11 14 380- A 9 12 415-440V A 8 11 500V A 7 9 660- A 5 6.5 Rated operational power of three-phase motors 220-240V 3 4 50-60Hz 380-440V 4 5.5 500-4 5.5 Utilization category AC4 Switching of squirrel cage motors, inching Rated operational current I e 220V A 12 15 open and enclosed 230V A 11.5 14.5 240V A 11 14 380- A 9 12 415-440V A 8 11 500V A 7 9 660- A 5 6.5 Rated operational power of three-phase motors 220-240V 3 4 50-60Hz 380-440V 4 5.5 500-4 5.5 Mini Motor Contactor J7KNA 7

Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type J7KNA-09- J7KNA-12- Utilization category DC1 Switching of resistive load 1 pole 24V A 20 20 Time constant L/R 1ms 60V A 20 20 Rated operational current I e 110V A 5 5 220V A 0.6 0.6 3 poles in series 24V A 20 20 60V A 20 20 110V A 20 20 220V A 16 16 Utilization category DC3 and DC5 Switching of shunt motors 1 pole 24V A 20 20 and series motors 60V A 5 5 Time constant L/R 15ms 110V A 1 1 Rated operational current I e 220V A 0.15 0.15 3 poles in series 24V A 20 20 60V A 20 20 110V A 20 20 220V A 2 2 Maximum ambient temperature Operation open C -40 to +60 (+90) *2 enclosed C -40 to +40 with thermal overload relay open C -25 to +60 enclosed C -25 to +40 Storage C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type "1" according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size gl (gg) A 40 40 Coordination-type 2 according to IEC 947-4-1 Light contact welding accepted max. fuse size gl (gg) A 25 25 Contact welding not accepted max. fuse size gl (gg) A 10 10 For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections for contactors without thermal overload relay main connector solid or stranded mm² 0.5-2.5 0.5-2.5 flexible mm² 0.5-2.5 0.5-2.5 flexible with multicore cable end mm² 0.5-1.5 0.5-1.5 Cables per clamp 2 2 solid or stranded AWG 18-14 18-14 8 Mini Motor Contactor J7KNA

Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type J7KNA-09- J7KNA-12- Frequency of operations z without load 1/h 10000 10000 Contactors without thermal overload relay AC3, I e 1/h 600 700 AC4, I e 1/h 120 150 DC3, I e 1/h 600 700 Mechanical life AC operated S x 10 6 5 5 DC operated S x 10 6 15 15 Short time current 10s-current A 96 120 Power loss per pole at I e /AC3 W 0.15 0.25 Resistance to shock according to IEC 68-2-27 Shock time 20ms sine-wave AC operated NO g 5 5 NC g 5 5 DC operated NO g 8 8 NC g 6 6 *1) Suitable at for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): U imp = 8kV. Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x U s and with reduced rated current I e /AC1according to I e /AC3 Mini Motor Contactor J7KNA 9

Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 Auxiliary Contacts Type J7KNA-09 J7KNA-12 J7KNA-09 D(VS) *1 J7KNA-12 D(VS) J73KN-A Rated insulation voltage U i V AC 690 *2 690 *1 690 *1 Thermal rated current I th to Ambient temperature 40 C A 10 10 10 60 C A 6 6 6 Power loss per pole at I th W 0.5 0.5 0.5 Utilization category AC15 Rated operational current I e 220-240V A 3 3 3 380-415V A 2 2 2 440V A 1.6 1.6 1.6 500V A 1.2 1.2 1.2 660- A 0.6 0.6 0.6 Utilization category DC13 Rated operational current I e 60V A 2 2 2 110V A 0.4 0.4 0.4 220V A 0.1 0.1 0.1 Maximum ambient temperature Operation open C -40 to +60 (+90) *3 enclosed C -40 to +40 Storage C -40 to +90 Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size gl (gg) A 20 20 20 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Power consumption of coils AC operated inrush VA 25 - - sealed VA 4-5 - - W 1.2 - - DC operated inrush W - 2.5 - sealed W - 2.5 - Operation range of coils in multiples of control voltage U s 0.85-1.1 0.8-1.1 - Switching time at control voltage U s ±10% *4,*5 AC operated make time ms 15-25 - - release time ms 8-25 - - arc duration ms 10-15 - - DC operated make time ms - 15-19 - release time ms - 8-25 (35) *1 - arc duration ms - 10-15 - 10 Mini Motor Contactor J7KNA

Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 Auxiliary Contacts Cable cross-section all connectors solid mm² 0.75-2.5 0.75-2.5 0.75-2.5 flexible mm² 0.75-2.5 0.75-2.5 0.75-2.5 flexible with multicore cable end mm² 0.5-1.5 0.5-1.5 0.5-2.5 Clamps per pole 2 2 2 Type J7KNA-09 J7KNA-12 J7KNA-09 D(VS) *1 J7KNA-12 D(VS) J73KN-A solid or stranded AWG 18-14 18-14 18-14 *1) version VS *2) Suitable at for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): U imp = 8kV. Data for other conditions on request. *3) With reduced control voltage range 0.9 up to 1.0 x U s and with reduced thermal rated current I th to I e /AC15 *4) Summary switching time = release time + arc duration *5) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). Mini Contactors for North America Data according to UL508 Main Contacts (culus) Type J7KNA-09 J7KNA-12 J73KN-A Rated operational current "General Use" A 15 20 10 Rated operational power of three-phase motors 115V hp 1½ 2 - at 60Hz (3ph) 200V hp 3 3-230V hp 3 3-460V hp 5 7½ - 575V hp 7½ 10 - Rated operational power of of AC motors 115V hp ½ ¾ - at 60Hz (1ph) 200V hp 1 1½ - 230V hp 1½ 2 - Fuses A 30 30 - Suitable for use on a capability of delivering not more than rms A 5000 5000 - (SCCR) V 600 600 - Rated voltage V AC 600 600 600 Auxiliary Contacts (culus) heavy pilot duty AC A600 A600 A600 standard pilot duty DC Q600 Q600 Q600 Mini Motor Contactor J7KNA 11

Dimensions AC and DC operated with screw terminals J7KNA-09 J7KNA-12 Auxiliary Contact Blocks J73KN-A Reversing Contactors J7KNA-09-01-R J7KNA-12-01-R J7KNA-09-01-R + J7TKN-A J7KNA-12-01-R + J7TKN-A Suppressor units J74KN-D-RC... ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J05E-EN-04 In the interest of product improvement, specifications are subject to change without notice. 12 Mini Motor Contactor J7KNA