Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

Similar documents
Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

Solenoid valves Type EVU

A full line of field-tested CO 2 controls, stocked for your convenience

Solenoid valves Type EVU for fluorinated refrigerants

CCMT - Electrically operated valves for transcritical and subcritical CO2

Electric expansion valve Type AKV 10P, AKV 10PS

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

Electric operated valves Type CCM for R744 / CO2

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Electrical Control Valves

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Solenoid valve Types EVR 2 EVR 40 NC/NO

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Pulse Width Modulation Valves. Models SPW-0 thru -7

Electric expansion valves Types AKVA 10, 15 & 20

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Solenoid coil Types BB, BE, BF, BG, and BN

Electric Expansion Valve Type AKVO 10

FSP Fan Speed Power Module Technical Data

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Float valve Type HFI. Data sheet

Accessories & spare parts - pressure transmitters

Refrigeration K-211. Replacement Parts. Chillers, Condensers. Compressors, Motors. Electrical. Components. Heating. Indoor Air Quality.

Valve Station in stainless steel ICF SS 20 and ICF SS 25

EMERSON CLIMATE TECHNOLOGIES-EX

VTZ variable speed Reciprocating compressors

90 bar capability. Food safety first Accept no risks in your CO 2 system.

Solenoid valves type EVR 2 40 NC / NO

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

High pressure float valve, type HFI REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electronically operated expansion valve for CO 2 Type AKVH

Crankcase pressure regulator Type KVL

Solenoid valves EVRA and EVRAT

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Crankcase pressure regulator Type KVL

Condensed Catalog 410A January 2008

Crankcase pressure regulator Type KVL

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Liquid level switch Type AKS 38

R-22 R-404A/R-502/R-507A R-12/

Crankcase Pressure Regulating Valves

Pilot valves for servo operated main valves

CO2 trends in Europe Advansor SKVP dagen, Stockholm 20 okt. 2017

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Electric expansion valve for R744 (CO 2 ) Type AKVH

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Oil Cooler AKZ328-D142 PL

PRODUCT DATA HDF SERIES Solenoid Valve

Pressure control valve Type KDC

(a) then mean effective pressure and the indicated power for each end ; (b) the total indicated power : [16]

Parallel Rack Systems R404A

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

INSERTION flow sensor for continuous flow measurement

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Servo-operated 2/2-way solenoid valves Type EV220A

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15

Cubic unit cooler. SKB semi-industrial range

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electric expansion valve Type ETS ETS 400

Cubic unit cooler. SKB semi-industrial range

MODELLING OF MOBILE AIR- CONDITIONING SYSTEMS FOR ELECTRIC VEHICLES

TEST REPORT #66. Compressor Calorimeter Test of Refrigerant HPR2A in a R-410A Scroll Compressor

3D drawings available at Kg GAS-NPT thread adapters available at page 1.117

Electronic suction modulating valves type KVS

LCU DX Efficient cooling with no loss of space

Pilot valves for servo operated main valves

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Float Switch AKS 38. Technical brochure MAKING MODERN LIVING POSSIBLE

Servo-operated 2/2-way solenoid valves for steam Type EV225B

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

Thermo -Expansion Valves Series TX7

AE R5 February 1997 Reformatted November 2010

Semi-hermetic GEA Compressors. Single- and two-stage reciprocating compressors (HG/HA)

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

Capacity regulators (hot gas bypass) PMC and CVC

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Solenoid actuator MB 7 and butterfly valves BVHM

AHN 064 to 304 EHN/CHN 064 to 304

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

INVESTIGATION OF FUEL CONSUMPTION AND SYSTEM PERFORMANCE BY CHANGING COMPRESSOR TYPE, CONTROL METHOD AND REFRIGERANT

Copeland Screw TM Compressors

Blue e+ chillers with the principle

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

TRIXCUBE TURNKEY SOLUTION

m-csg Ultra-compact Clean Steam Generation System

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

Pilot valves for servo opereated main valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Strainers in stainless steel Type FIA SS

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

Transcription:

Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Multi Ejector Solution TM, consists of a CTM 1 and CTM 2 liquid valves and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems economically competitive with the HFC systems at all ambient temperatures by improving COP in comparison to standard booster systems. CO 2 systems with Multi Ejector Solution TM can be installed in any climate delivering lower energy consumption than i.e. R404A. It removes the CO 2 equator entirely. CTM 1 and CTM 2 Liquid Ejector is designed for CO 2 booster systems to pump the CO 2 liquid from the low point in the suction accumulator back to the receiver resulting even in 5 bar pressure lift after mixing with gas coming from the gas cooler. Features First Cost savings Lower cost compared to standard booster system due to lower swept volume of compressors. (i.e. smaller compressors or less number of compressors). Fast Pay Back Energy saving Improved COP and lower swept volume to the MT compressors, resulting in lower energy consumption. Savings for end users. Reliable and robust design confirmed in field tests. Fully integrated solution not requiring any additional components like check valves or motorized ball valves. Fully serviceable - wide range of spare parts and accessories. Easily accessible strainer / filter for fast maintenance. Brings first cost savings. - Enables 5-10 % savings on compressor swept volume, compared to standard booster systems Fast payback lower energy consumption. - Less compressors and higher efficiency on the systems, leads to shorter payback time of less than 2 years on avarage globally. The combination of CTM 1 and CTM 2 Liquid valve and the AK-PC 782A ensure an easy setup and commissioning, robust control of the system that ensures many years of problem free operation. DKRCC.PD.VM0.B2.02 1

Approvals Pressure Equipment Directive 2014/68/EU (PED) UL Recognized Technical data Refrigerant: R744 with oil Maximum working pressure: 140 bar / 2031 psi Max. test pressure: 1.43 x 140 bar / 1.43 x 2031 psi Max. OPD: 90 bar / 1305 psi (for single-voltage coil, 50 Hz) Min. OPD: < 0.1 bar / 1.45 psi Max. pres. dif. E and C connections: 20 bar / 290 psi Media temp. range: -10 C +50 C / +14 F 122 F Ambient temp. range: -10 C +50 C / +14 F 122 F Humidity: 0 100% R.H. (0-97% R.H. non-condensation condition if IP level is below IPX5) WARNING! DISCLAIMER The CTM Multi Ejector valve is approved for use only with controller type AK-PC 781A and AK-PC 782A. expressly disclaims, and any responsibility or liability, whether based on contract, breach of warranty, tort, statute or otherwise, shall be excluded, if the CTM Multi Ejector valve is used with any controller other than a controller type AK-PC 781A and AK-PC 782A. For further information on AK-PC, please see separate document. Connector positions Can be interchanged (see drawing below) Label Label Strainer Ejector 1 Ejector 2 Strainer High pressure inlet A High pressure inlet A Suction inlet C Suction inlet C Receiver E Receiver E For mounting / service of ejectors Mounting order of ejectors for CTM 2: Ejectors with the highest capacities (longest ejectors) must be placed closest to the suction connector C. Any ejector dummy should be placed after the ejectors. A: Gas cooler outlet - Ball valve - inlet connector Combi brazing 1 / 2 inch ODF - weld 5 / 8 inch (EN10220) C: Suction connector. MT evaporator outlet - Ball valve - suction connector. Combi brazing 1 / 2 inch ODF - weld 5 / 8 inch (EN10220) E: Common outlet connector - Ball valve - Receiver Combi brazing 1 / 2 inch ODF - weld 5 / 8 inch (EN10220) DKRCC.PD.VM0.B2.02 2

Ordering Multi Ejector CTM 1 Multi Ejector CTM 1 Capacity - Mass flow 1 ) Capacity - Mass flow 2 ) [kg/h] [lb/h] CTM 1 LE 200 200 441 032F5683 CTM 1 LE 400 400 882 032F5684 Multi Ejector CTM 2 Capacity - Mass flow 1 ) Capacity - Mass flow 2 ) [kg/h] [lb/h] CTM 2 LE 600 600 1323 032F5685 1 ) R744 at 40 bar / 5 C 2 ) R744 at 580 psi / 40 F (LE = Liquid ejector) (The above code numbers are without coils which should be ordered separately see coil ordering below). CTM 2 Approvals (Coils) AS230CS: LLC CDC TYSK; The Low Voltage Directive 2014/35/EU (LVD); Electromagnetic Compatibility Directive 2014/30/EU (EMC) AZ120CS: C UR US; LLC CDC TYSK; The Low Voltage Directive 2014/35/EU (LVD); Electromagnetic Compatibility Directive 2014/30/EU (EMC) Ordering coils / accessories DIN spade connection Voltage Frequency / Power consumption [V] [Hz] [W] [Hz] [W] with DIN plug 1 ) AS230CS 230 50 8 60 7 042N7601 AZ120CS 110-120 50 8.5 60 7 042N4202 1 ) The three pins on the coil can be fitted with spade tabs, 6.3 mm wide (to DIN 46247). The two current carrying pins can also be fitted with spade tabs, 4.8. mm wide. Max. lead cross section: 1.5 mm 2. Voltage variation: V AC -15% - 10%, If DIN plug is used (DIN 43650) the leads must be connected in the socket. The socket is fitted with a Pg 11 screwed entry for 6 12 mm. Plug for DIN spade connection Voltage [V] Frequency DIN plug (LED) 230 50 / 60 042N0265 2 ) DIN plug Max. 250 50 / 60 042N0156 2 ) Only for AS230CS. Sizing Liquid Ejector capacity Liquid Ejector Capacity of MT CTM 1 LE 200 40-90 kw CTM 1 LE 400 90-180 kw CTM 2 LE 600 180-270 kw The data above show MT capacities estimated for systems equipped in CO 2 Adaptive Liquid Management (CALM) DKRCC.PD.VM0.B2.02 3

Spare parts Part Ejectors Capacity - HP Mass flow Description [kg/h] [lb/h] CTM ELE 200 200 441 1. Completely assembled ejector with O-rings already mounted 032F9110 CTM ELE 400 400 882 1. Completely assembled ejector with O-rings already mounted 032F9111 X 1 X 6 X 2 X 2 Part Description Strainer CTM strainer 1. Mesh only 2. 2 sets of 2 O-rings 032F9113 O-rings CTM O-rings 1. 2 sets of 2 O-rings for strainer 2. 6 sets of 3 O-rings for ejectors 032F9114 Connectors DN 15 Connector + O-ring 032F9115 DKRCC.PD.VM0.B2.02 4

Design and function Ejector 1 Ejector 2 Strainer 32F1019.10 Valve configuration Product name Ejector 1 Ejector 2 CTM 1 032F5683 CTM Multi Ejector LE 200 CTM ELE 200 - CTM 1 032F5684 CTM Multi Ejector LE 400 CTM ELE 400 - CTM 2 032F5685 CTM Multi Ejector LE 600 CTM ELE 200 CTM ELE 400 Function The Multi Ejector function is shortly described below. 32F996.12 Nozzle Throat Exit Mixing chamber Diffuser P H P L P S P D Pressure P H P D P L P S Intake due to pressure differential An ejector is a device that uses expansion energy to compress another fluid. In this case with the transcritical system there is up to 20% of the compressor work that can theoretically be recovered in the expansion. In this case with the Multi Ejector system the work is coming from the CO 2 leaving the gas cooler. The high pressure CO 2 (PH) is entering the nozzle where the expansion is taking place. At the exit of the nozzle the speed is very high and as a consequence of that the pressure is low. Pressure increase due to reducing flow velocity This low pressure is used to drag vapour from the MT suction (PL). From there the two flows are mixed in the mixing chamber where the pressure will be lower than at the drive inlet due to the mixing of vapour from a higher pressure. After the mixing the flow enters the diffuser where the flow is slowed down. The shape of the diffuser enables the conversion from kinetic energy (velocity) to potential energy (pressure). After the diffuser the flow is returned to the receiver. DKRCC.PD.VM0.B2.02 5

Application Gas cooler AK-PC 782A MBS 8250 AK-SM 8XX/ AK-SM 720/ CCMT (ICMTS) Multi Ejector AKS 21A MBS 8250 MBS 8250 FC 103 MT MBS 8250 CCMT (ICMTS) AKS 4100 DGS AKVH AK-CC 550A AKS 32R Medium temp. load LT FC 103 AKVH AK-CC 550A AKS 32R MBS 8250 Low temp. load HP High Pressure (120-140 bar Max working pressure) HP Receiver Pressure (60-90 bar Max working pressure) LP Suction Pressure MT (35-55 bar Max working pressure) LP Suction Pressure LT (25-30 bar Max working pressure) R64-2121_20 The Multi Ejector is designed to lift a part of the liquid from MT suction and mix it with the gas coming from the gas cooler at medium pressure level. DKRCC.PD.VM0.B2.02 6

Controller AK-PC 782A offers a wide range of market leading Pack Controllers. Being the flag ship and best in class controller for transcritical CO 2 packs controls, the AK-PC 782A offers the highest possible efficiency with the Multi Ejector, CTM. The complete application control features: Complete booster pack control of up to 3 suction groups (max. 12 compressors) and high pressure system Significant savings with heat recovery for tap water and heat reclaim Extensive control of oil flow and pressurization Best in class safety monitoring and fail-safe functions Minimal energy consumption while ensuring optimal food quality Auto-configured, easy-to-use graphical representation with System Manager Independent, customised control and monitoring of auxiliary function DKRCC.PD.VM0.B2.02 7

Material specification Housing: Aluminium AW-6082 T6 Connections: Stainless steel AISI 304 Ejectors: Brass Screws: Stainless steel A2-70 Dimensions and weights CTM 1 CTM 2 32F889.10 32F890.10 32F888.10 60 90 29 mm / 1.14 inch 106 mm / 4.2 inch 176 mm / 6.9 inch 200 mm / 7.9 inch 250.7 mm / 9.9 inch 60 90 29 mm / 1.14 inch 106 mm / 4.2 inch 176 mm / 6.9 inch 200 mm / 7.9 inch 250.7 mm / 9.9 inch 47.3 mm / 1.86 inch 92.5 mm / 3.6 inch 156.5 mm / 6.16 inch 47.25 mm / 1.86 inch 131 mm / 5.16 inch 195 mm / 7.7 inch 45 mm / 1.77 inch Weight: 2.6 Kg / 5.7 lb Weight: 3.6 Kg / 7.9 lb DKRCC.PD.VM0.B2.02 8