Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

Aura Interior Wiring Manual (5-Wire and BACnet)

SAVE THESE INSTRUCTIONS

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

MIL-24/2600Q MIL-24/3200DQ

ZoneZ Lite Quick Start Guide

ValveMate 7000 Controller Operating Manual

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

Operating Instructions

BRAVO Inverter/Battery Charger. Table of Contents

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

MaxLite LED Medium Area Light

Installation and Operation Instructions 10/04/13

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Emergency Bypass / Shunt Relays (UL924)

DC to AC Power Inverters

DC to AC Power Inverters

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

UL AND CODE COMPLIANCE

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNERS MANUAL JANUARY 2007 ISO

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Figure 1: WPR2 Dimensions and Hardware

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

LED Downlight Ceiling Fixtures

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

SAVE THESE INSTRUCTIONS

LEV/Wn Building A Connected World

DALI 650mA LED Driver

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

Operating Instructions

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

AUTO CHARGE LPC SERIES

Application Engineering

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

OWNERS MANUAL JANUARY 2007 ISO

ADI-125/750 ADI-125/1500 ADI-125/2500

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Elle Surface Mounting Instructions

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Installation and Operation Manual

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Tina 4A Connection block

TC26-B Vehicle Sensor

Operation/Installation Instructions

UV DISINFECTION UNIT MODEL 3G

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

INSTALLATION & OWNER'S MANUAL

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

MaxLite LED Linear HighBay Fixtures

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

/$03:$77$*( 7<3( &2'(180%(5 :(,*+7J :

FMC-1/2 Tina Muting unit

Installation Instructions for Eaton Surge Protective

DUALBRITE Motion Sensing Coach Light

1000 DE BOSS. Installation & Operating Instructions COMMERCIAL FIXTURE READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST

COLD AIR INTAKE SYSTEM, CIVIC Si,

Installation/Operating Instructions

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

MAXLITE RKT LED Retrofit Kit

LED Auxiliary Devices

User Guide. Model Insulation Tester / Megohmmeter. Introduction

ECO-T LED RECESSED TROFFER USER MANUAL

ONBOARD AIR HOOKUP KIT

AUTO CHARGE 1200 PUMP PLUS

SCR Power Controllers

The Da-Lite Difference.

AFM500X Automatic Flashing Module

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

WF-5110R True Sine Wave Inverter

BATTERY SAVER LOW RIPPLE HO

Motion Sensing Coach Light

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

RU SERIES UPGRADE TempAssure Compatible

TA-6-way valve. Standard control valves 6-way valve for change-over systems

Transfer Switch GPTS 30

Application Engineering

INSTALLATION INSTRUCTIONS

Transcription:

SPECIFICATIONS v2 Fixture Mount Power Pack Model: Fixture Sensor Power Pack V2 120/277/347VAC, 60Hz @347VAC 3.4A () 2A () Power...120/277/347VAC, 60Hz Relay Type... Form C with Zero Crossing on N.O. only Output... 70mA @ +24VDC with relay connected Load Requirements @120VAC...5.0A (), 3.0A (), 1/6hp @277VAC...4.3A (),, 1/6hp @347VAC... 3.4A (), 2.0A () Low Voltage Connections... connection to FS sensors... Control in, common, +24VDC Line and Load Connections...12-18AWG screw terminals Terminal Torque Rating...4.428 inch pound-force (0.5Nm) Operating Temperature... 32 to 131 F (0 to 55 C) Dimensions... 7.5 x 0.87 x 1.0 (190 x 22 x 25mm) Installation Instructions

LISTED Control DESCRIPTION AND OPERATION The v2 power pack supplies low voltage power to FS series occupancy sensors and switches line voltage in response to control signals from the sensors. The v2 is designed for installation inside the lighting fixture housing. A 6 long cable fitted with a male plug is supplied with each FS series 24VDC occupancy sensor. The FS PP has a corresponding female receptacle. This cable carries power to the sensor and lighting control signals to the power pack. Each Watt Stopper v2 can supply power for up to seven FS series low voltage sensors. FS-CK accessory kits are required to connect multiple sensor or multiple power pack wiring configurations. Wiring connected to the is limited to an aggregate total of 100. High voltage connections should use at least 16 gage wire. Always check local building codes. INSTALLATION CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING THE POWER PACK. 1. Determine an appropriate mounting location inside the light fixture. 2. Use the holes or mounting slots at both ends of the power pack to secure it to the fixture. 3. Connect wires to load as described in the wiring section. 4. Connect wires to electrical supply as described in the wiring section. 5. Connect the from the sensor to the on the power pack. 6. Restore power from the circuit breaker. High voltage wiring: 12-18 AWG, Cu Only Strip Gage 1/2" 12.7mm Relay Output to load COM OUTPUTS TO LOAD ISOLATED RELAY TO SENSOR 03500r1 Low voltage connection to FS sensor Model: Fixture Sensor Power Pack V2 120/277/347VAC, 60Hz @347VAC 3.4A () 88T9 Santa Clara, CA 800.879.8585 2A () Appliance 12-18AWG CU wire only High voltage AC input wiring GROUND NEUTRAL LINE Green LED - Operation monitor Fig 1: v2 wire connections and operation monitor LED Call 800.879.8585 for Technical Support

Model: Fixture Sensor Power Pack 120/277/347VAC, 60Hz LISTED @347VAC 3.4A () 88T9 Santa Clara, CA 800.879.8585 2A () Appliance Control Model: Fixture Sensor Power Pack 120/277/347VAC, 60Hz LISTED @347VAC 3.4A () 88T9 Santa Clara, CA 800.879.8585 2A () Appliance Control WIRING A SINGLE SENSOR Com COM ISOLATED RELAY OUTPUTS TO LOAD TO SENSOR 03500r1 V2 12-18AWG CU wire only GROUND NEUTRAL LINE Ground Neutral Line 120/277/347 Volts AC Neutral Lighting Load Plug from FS sensor Green Operation LED Fig 2: v2 direct wiring to lighting load 0-10VDC 0-10VDC Dimming Ballast Outputs to Lamps Com Violet Grey Line Voltage Inputs to Ballast COM ISOLATED RELAY OUTPUTS TO LOAD TO SENSOR 03500r1 Plug from FS sensor V2 Green Operation LED 12-18AWG CU wire only GROUND NEUTRAL LINE Ground Neutral Line 120/277/347 Volts AC Fig 3: v2 wiring to 0-10V dimming ballast Visit our website for FAQs: www.wattstopper.com

CONTROL CONFIGURATIONS Standard connection between FS sensor and power pack Fig 5: One sensor controlling one Power Pack One FS sensor connected to two FS-C3 (3') or FS-C1 (10' shown) Fig 6: One sensor controlling two Power Packs Two FS sensors connected to one FS-C3 (3' shown) or FS-C1 (10') Fig 7: Two sensors controlling one Power Pack Two FS sensors connected to two FS-C3 (3') or FS-C1 (10' shown) Fig 8: Two sensors controlling two Power Packs Call 800.879.8585 for Technical Support

TROUBLESHOOTING Lights will not turn on: Sensor LED does not flash: - Is green power pack LED on? If yes, check connections at sensor and power pack. If no, check circuit breaker and wiring to power pack. - Check all wire connections. LED does flash: - Check all wire connections and verify the load wire is tightly secured. If lights still do not turn on, call 800.879.8585 for technical support. Lights will not turn off: The time delay can be set from 30 seconds to 30 minutes. Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor s view. Lights should turn off after 30 seconds. If lights still do not turn off, call 800.879.8585 for technical support. Call 800.879.8585 for Technical Support

ORDERING INFORMATION Catalog # v2 FS-105 FS-205 FS-305 FS-405 FS-505 FS-505C FS-C1 FS-C2 FS-C3 FS-C5 Description Fixture Mount Power Pack: 120/277/347VAC, 60Hz with NO/NC Relay output Ceiling tile mount, low voltage PIR occupancy sensor with adjustable time delay and light level Fixture mount, low voltage PIR occupancy sensor with adjustable time delay and light level Fixture or Ceiling tile mount, low voltage PIR occupancy sensor, adjustable time delay Fixture mount, low voltage PIR occupancy sensor w/20 diameter coverage, adjustable time delay and light level Fixture mount, low voltage ultrasonic occupancy sensor Same as FS-505, with directional cones One 10 cable with a shielded male connector at each end 10' (3m) One 6 (152mm) cable with 3 flying leads at one end and a shielded male connector 6" (152mm) at the other One 3 cable with a shielded 90 3' (914mm) male connector at one end and a shielded straight male connector at the other end, for space-limited areas Shielded splitter with female to dual female receptacles Shielded male-to-male coupler Sensors and power packs are White. WARRANTY INFORMATION Watt Stopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. 2800 De La Cruz Boulevard, Santa Clara, CA 95050 800.879.8585 www.wattstopper.com 03391r5 4/2012