Control Systems. All necessary control circuits with safety interlocking for the following system will be provided:

Similar documents
Modern ManufacturingServices.LLC. Attachments And Auxiliary Equipment

Super Calendar. Heated rolls

Center Winder Specification

Super Calendar. Heated rolls

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

Slitter Rewinders.

Performance Increase In Existing Slitter/Rewinders By Upgrading Controls

Programmable Logic Controller. Mat Nor Mohamad

Updated: October 2012

MALSR APPROACH LIGHTING. Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS

STEADYWEB TENSION CONTROLLER Data Sheet

Slitters - Coaters - Accumulators - Winders.

SECTION MOTOR CONTROL

PATTERSON PUMP COMPANY

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

825-P Modular Protection System for motors Specification Guide

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Winding solutions for all your web handling needs.

7. SERVICES OVER 600 VOLTS

WARREN COUNTY, N.Y. M/E REFERENCE

CUSTOMIZED MODULAR ROLL STANDS

Say hello to better web control.

MaxPak Plus Analog DC V S Drive

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Single-Phase Step Voltage Regulators

TAKE IT TO THE NEXEN LEVEL

E.S.P. Embedded Sensing Probes for Motor Brushes

ShaftLok Safety Chucks

Fincor Series 2230 MKII/2240

PERFECT COMBINATION EFFICIENTLY USED. Competent customer consulting Professional selection Integrated tools Powerful products Reliable quality

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Features and Benefits. Control Features

radial GATES Waterman Industries of Egypt

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Model R1500 Reciprocator

ALSF APPROACH LIGHTING. High-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS. Operating Conditions. Compliance with Standards

revised September 11, 1997

Softstarters Type PSS. Softstarters. General information

Single-phase step voltage regulators

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Web Volume Control Model WV220

All Greenerd Presses are designed and built to ANSI B (R-2000) compliance. 4-POST HYDRAULIC DEEP DRAW PRESS

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

Selection Guide. PowerFlex Digital DC Drive

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

MA Series rotary tower automatic Stretch Wrapping Systems

team master medium voltage solid state starters

SECTION VARIABLE FREQUENCY DRIVE UNITS

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

MAGPOWR Spyder-Plus-S1 Tension Control

Differential Rewind Shafts

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

GE Sensing & Inspection Technologies

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

CNC Tool Room Milling Center MODEL: VM-760

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

TAPPI PRESS. The Mechanics of Winding Edited by David R. Roisum, Ph. D pp., 7" x 10" soft cover Item Number: 0101R236 ISBN:

CABINET REEL OPERATING INSTRUCTIONS

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

Generator Fire Safety: Generator assemblies should be located outside the building.

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Tension Control Systems for Light, Medium, and Heavy-Duty Tensioning

TCS Series Analog/Manual Controls

PARTS-WIRING TECHNICAL MANUAL MSHA PERMISSABLE CONTROLS CB-801 CB-8218

2 SLR Series Line Reactors... 50

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Electromotive Systems SBP2 Pendant Pushbutton Stations


Side Seal Horizontal Shrink Wrapper

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Design Standard. Purpose: Design Standard:

PROCUREMENT SPECIFICATIONS DELTA MODEL DSC 1500 PORTABLE BEAM - CRASH CERTIFIED BARRIER SYSTEM

Carbon Fiber Air Shafts. Custom Carbon Fiber Tubes

SIGNAL WORDS QUALIFIED PERSON

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

EXTRA PRICES XTRA-0312 EFFECTIVE: ALL PRICES IN U.S. DOLLARS

J.R. Clancy, Inc. Phone: , Interstate Island Road Fax: Syracuse, New York

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Single-phase pad-mounted step voltage regulator

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Induction Power Supplies

Ampgard medium voltage motor control renewal parts

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Converting Applications Made Easy Presented by Jeff Reese Manufacturing in America March 14-15, 2018

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

Direct Coupled Damper Actuator Model MY6050A1001

AIR COOLED RECTIFIER SPECIFICATION S-50-A

FAN-STOP INSTRUCTION MANUAL

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Transcription:

Control Systems Hydraulic Control A separate Hydraulic Power System will be supplied. The hydraulic power components including the motor driven pump, reservoir, valves and necessary controls will be integrally mounted on the common base. All necessary control circuits with safety interlocking for the following system will be provided: Rider Roll Nip Control Core Chuck Control Core Chuck Lift Control Nip Cradle Control Roll Ejector Control Automatic Rider Roll Nip Relieving An electronic control system featuring ultra sonic sensor for roll diameter sensing. Signal will be fed to PLC for roll diameter reference and also to computer control circuitry that electronically establishes the five (5) required operating parameters. Automatic Drum Torque Control Control circuit with a 0 10 volt DC signal is fed to the solid state drive. A resultant signal is fed to drum drive circuitry for programming the desired load (load sharing) in accordance with the roll diameter build up. Features operator adjustment for starting load differential, length of program and minimum load. Drum load is displayed in percent on panel view screen. Control Panel Provide a new heavy gauge operator s panel with all auxiliary controls: Tension, Rider Roll Nip, Roll Eject, Slitters Engage/Disengage, Nip Cradle, Core Chuck Control. Drive Controls Such as Drum Load, Slitter Drive On/Off Selector, Speed Indicator, Speed Control is incorporated in the Allen Bradley PLC5 and will do all logical control. Also, included is an Allen Bradley Panel View display incorporating several user friendly color set up screens that are very easy to operate. The machine operator does not need special computer skills to set up for easy selection of winding parameters in accordance with web grades. Safety Equipment Safety pilot operated check valves in hydraulic circuitry prevent movement in the event of line rupture, loss of pressure, or pump failure. Roll eject operation has safety interlocking systems to prevent personnel injury and equipment damage. Interlock switches and proximity switches to confirm core chucks are either engaged or disengaged.

Roll Eject Operation Permissive Circuitry Provided Drive fully stopped Hydraulic unit operating with required system pressure Chucks disengaged Chucks fully raised Rider Roll fully raised and safety latches engaged Nip Barrier fully raised and safety latches engaged Winder Run Mode Requirements Provided Chucks engaged Chucks relieve mode actuated Rider Roll lowered onto cores and nip load program initiated Nip cradle fully raised All Safety guards for above equipment, where required, will be provided. EMC warrants that the equipment will conform to the specifications set forth. Also, the equipment will be primed, painted machinery enamel and completely assembled to insure alignment accuracy. Recalibrated Drive System Drive Two Motor Drum Drive System, MagneTek DSD Digital Drive. This system consists of a dual DC motor digital drive and also includes two (2) drive systems housed in NEMA 1 cabinets consisting of the following: QTY, (2) 40 HP, 500V, 1750 RPM DC motors with blowers & encoders QTY, (1) Digital Drive Package Incorporating; QTY, (2) 60 HP DC Drives Included is common control with all drives and automatic common control logic along with all necessary speed control for two drum winder systems. Includes a PLC5 Gateway to interface with EMC s Allen Bradley PLC for logic and numeric transfer. DESCRIPTION AND COMMENTS ON PROPOSED SYSTEM The Basic System is composed of 2 50 HP Drives The proposed system has an LAN network and will have a gateway to interface with an AB PLC 3 or 5 via a 1771 remote I/O network.

Listed below is a Bill of Material of items included: Item 001 Control QTY. (1) Mounted Nema 12 blower/filtered 2 door enclosure (84 H x 74 W x 20 D) floor with the following mounted and wired: Main CB with outside operating door interlock for 460/3/60 incoming power. Oversized 115V, 1 phase, 60 Hz control transformer. PLC Gateway (PLC 5) Main E Stop / Reset pb &circuit. Rear Drum Drive 50 HP DSD412 regenerative drive. Front Drum Drive 50 HP DSD412 regenerative. Item 002 DC Motor (Drums) QTY, (2) 40 HP, 1750 RPM, drip proof with blower & filter enclosure, 500 VDC armature, 300VDC field, 368AT frame. Item 004 PCDU QTY, (1) Portable Control Display Unit with cable. Item 005 CONNECTOR QTY, (1) DB25/RJ12 Up/Down Load adapter with 20ft. cable Item 006 MANUALS QTY, (3) Instruction Manuals with all dimension drawings, hardware, and software diagrams. Item 007 ISOLATION TRANSFORMER QTY, (1) 110 KVA 460/3/60 delta primary with +/ 5% voltage tap, 460/3/60 wye secondary. Unwind Stand Two (2) shaft less adjustable unwind stands for roll width of 24 to 90 with 3, 4, and 6 core chucks. Sole Plates Will be thermal stress relieved and blanched ground. Counterbored holes are provided for anchor bolts. A ½ 13 NC tapped through hole is located close to each anchor bolt hole for leveling during setting and optical alignment. A total of four (4) pieces are required. Assembly, Hardware & Painting All necessary hardware will be furnished. Winder components will be fully assembled insuring correct fit and alignment requirements. All required surfaces will be primed and painted.

D C I 2 Drum Winder Mill Duty Shaftless Winding narrow Width slitting capacity. Paper Weight 15 lb. to 130lb/3000SF Face 90 Trim 86 Maximum Speed 5000FPM Drum Diameter 26 Rewind Roll Diameter 72 Core Sizes 3 & up Tension 1 6.5PLI Reel Diameter 60 Drum Motors [2] 40HP Recalibrated Drive Included Shaftless winding featuring Anti friction Carriage Assemblies with trim width adjustment 22 84. Automatic trim width adjustment. Large diameter drums provide improved roll structure control especially on lightweight paper grades. Horizontal Slitter threading featuring Free Standing Assemblies to better isolate possible vibration sources. Dual Spreader Rolls for on the run adjustment for any order requirements. Single Spreader Roll before slitters provided to promote a more uniform Cross machine web tension improves slitting quality and slip separation. Tidland Class III Top Slitter holders.

Sheet Threader provided to automatically thread web up to winder drums. Shaftless floor pick up unwind stands featuring Air Cooled Disc Brakes Individual control stations provided. Controls provide roll centering to Winder