Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

Similar documents
Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

product Oil burners, 1-11 monarch burners, sizes 1-11 ( kw) simply reliable Information on oil burners

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

Oil, gas and dual fuel burners. Burner series

product WM 10 for gas, oil, and dual-fuel WM 10 monarch burners ( kw) versatile performance Information on gas, oil, and dual-fuel burners

Doing more for clean environment and energy saving

Oil, Gas and Dual Fuel Burners

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels

Weishaupt Low NOx Solutions for Boiler Applications

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Old documentation - Only for your information! Product is not available any more!

Light oil - kerosene burner

ONE STAGE GAS BURNERS RDBS SERIES

MULTIFIRE. High temperature dual fuel burner

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

FUEL OIL BURNERS. By Mark Butterfield March 09

Oil - kerosene burner

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Installation- and maintenance instruction ST120 S75/21

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Installation- and maintenance instruction BENTOFLEX ST120KAV

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

info Combustion managers W-FM50, W-FM100, W-FM200 The capabilities of Weishaupt combustion managers

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Tightness control TC. Product brochure GB Edition 12.10

Oil, Gas and Dual Fuel Monoblock Burners

Installation- and maintenance instruction BENTOFLEX ST 108 PL

RS/M SERIES. Modulating Gas Burners FIRING RATES

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

Combination controls CG 10

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼


VAILLANT SPARE PART CATALOGUE

VIESMANN. Datasheet Part no.: see pricelist, price upon request Not suitable for sizing the boiler. For this, see the separate technical guide.

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Kerosene - oil burner

3 Edition Product brochure GB AGA

Zirconia Oxygen Probe

Solenoid actuator MB 7 and butterfly valves BVHM

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

info NO x emissions < 30 mg/kwh 4LN-version gas burners (with flue gas recirculation) Information on ultra-low NO x gas burners

CODE MODEL TYPE PRESS GW 605 T80

DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

AUTOFLAME Combustion Managment System

Gas Pressure Governors

BGD278 Series BASOTROL CE Approved Gas Valve

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

51/60G. Four-stroke gas engine

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

Installation- and maintenance instruction B80-2/3

PRODUCT RANGE

EKS 210/EKS 312. Vertical order picker (1000 kg/1200 kg)

RS Series Two Stage Progressive Gas Burners

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

COMMERCIAL BOILERS Eco-HK / Eco-PK KW

Power Flame Incorporated

Data sheet - Selected technical standards

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Valve monitoring system VDK 200 A S02

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

Installation- and maintenance instruction B20K-2

INFRA RADIATION EFFICIENCY UP TO 75%

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Transcription:

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

Description Weishaupt WK series industrial burners have been especially designed for industrial capacity ranges. The construction kit principle enables these burners to be matched to numerous special applications. The 3LN version of the Weishaupt WKGL70 burner enables a reduction in emissions that, until recently, would not have been considered possible for ratings up to 12 MW. Modern, proven combustion technology The patented fuel distribution principle has opened a new chapter in the history of LowNO x burners. A small proportion of the fuel is combusted centrally with a yellow-coloured core or primary flame. Simultaneously, the larger part of the fuel is sprayed from the combustion head via the concentrically arranged atomising nozzles into the fast moving combustion air. This fuel/air mixture mixes in the combustion chamber with hot, recirculated combustion gases. The heat causes the finely atomised fuel to begin to gasify. The mixture ignites and is fully combusted in the main flame. Along with the core flame, a narrow continuous main flame is formed, which is almost blue like a gas flame. Weishaupt multiflam burners have proved themselves well during hard, daily operation. In Switzerland particularly, which has Europe s most stringent emission limits, there are many Weishaupt multiflam burners in use already on combustion plant. Exemplary emission figures Weishaupt multiflam technology enables even industrial sized burners to reduce emissions to levels that for years were considered to be unachievable. With suitable combustion chamber conditions, Weishaupt multiflam burners can considerably undercut all the emission limits for larger combustion plant currently in force worldwide. Digital combustion management The W-FM 100 and W-FM 200 combustion managers ensure the simple and safe operation of combustion plant. 2 All important functions, such as fuel and air feed or flame monitoring are controlled with digital precision. The aim is the optimisation of operational functions, the maximisation of economy, and the minimisation of emissions. Thanks to digital combustion management such an optimisation is available today at limited cost. The outlay for installation and service is substantially lower than with conventional technologies. For example, a separate control panel for the burner switchgear is no longer necessary. Furthermore, remote operation, diagnosis and monitoring of the plant can be realised. That makes things safer and simpler for the operator. Applications The burners can be used with heat exchangers such as hot water boilers, steam boilers, air heaters, and for certain process applications. Low NO x operation The dimensions and volume loading of the combustion chamber are critical for Low NO x emissions. The various NO x levels and the combustion chamber requirements can be found in the publication Conditions for attaining the NO x emission values for Weishaupt burners. The burner is not suitable for use on reverse flame boilers. Saving energy with speed control and O 2 trim Electrical consumption is a cost factor for large plant. Speed control utilises a frequency convertor to vary the speed of the fan to match the amount of combustion air to the current fuel throughput. This enables a considerable saving of electrical energy, particularly at partial load. O 2 trim ensures optimal combustion, efficiency by continually monitoring the flue gases, thus reducing fuel consumption. Both speed control and O 2 trim are effected by the W-FM 200 digital combustion manager. Fuels Light fuel oil EL - DIN 51603-1 Natural Gases E and LL - EN 437 Installation sites In standard execution (materials, construction, protection), the burners are suitable for use indoors at temperatures between -15 C and +40 C and with a maximum relative humidity of 80%. Certification The burners have been independently tested and comply with the following European standards and EC directives: EN 267 / 676 (Best, Class 3 emission levels for light oil and natural gas) Machinery Directive 98/37/EC Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Gas Appliance Directive 90/396/EEC ressure Vessel Directive 97/23/EC Outstanding service Weishaupt maintains an extensive global sales and service network. Customer service is available every day around the clock. In-house training by Weishaupt ensures the high standard of their service engineers.

multiflam mixing head Flame tube Flame sensor Gas pilot line Sight glass Mixing head servomotor ressure switch Solenoid valve Air damper Controls including oil supply system, stepping motors for the mixing head and oil regulator, ignition unit Diagram of Weishaupt WKGL70 burner NO x mg/m 3 150 140 130 120 110 100 90 70 50 40 30 20 10 Fuel oil EL Natural Gas E/LL 80 60 Secondary nozzle 1 Secondary nozzle 2 Secondary diffuser disc rimary diffuser disc rimary nozzle rimary air Secondary nozzle 3 Secondary nozzle 4 Secondary air Out performance of the most stringent emission levels Diagram of the mixing head 3

The advantages of digital combustion management Control and Display Unit Digital combustion management means optimal combustion figures, continually reproducible setting figures, and ease of use. Weishaupt burners are equipped with electronic compound and digital combustion management since modern combustion technologies demand a precise, continually reproducible dosing of fuel and combustion air. Only in this way can optimal combustion figures be ensured over extended periods. If required, the burners can also be equipped with O 2 trim and speed control. Error free operation via a clear text display. Setting and control of the burner functions is achieved using a control and display unit with a clear text display. The CDU is linked to the combustion manager via a safety bus system and can be placed anywhere the user chooses within 100 m of the burner. Flexible communication possibilities The inbuilt interface enables all necessary information and functions to be relayed to a BMS system. If required, a modem enables a telephone connection to be installed for remote operation (e.g. oil/gas change-over, adjustment of setting values) and remote diagnosis. Communication with external systems via Bus. If data has to be exchanged between burners and other heating systems with LC devices, Weishaupt E-Gate acts as a gateway and translates the ebus protocol into the standard rofibus D protocol. Integration with building management For the control and management level, Weishaupt offers rograf NT - a software product that provides a real time solution to meet all requirements. The price advantage of new technology With improved technology and ease of use, combustion plant is becoming even more economical. No additional burner controls are required, since this effected by the combustion manager. Contactors and burner motor fuses are the only additional items required. Less installation work means fewer errors: the burners are tested as a complete unit at the factory. No additional costs for valve proving. If required, the W-FM 100 can be fitted with a capacity regulator and speed control module. No separate equipment is required. The capacity regulator and speed control module are included as standard with the W- FM 200. Commissioning and service work takes less time. The initial pre-setting of the burner is carried out at the factory. On site, only the site specific load points have to be determined. To facilitate O 2 trim, only an O 2 probe and O 2 module have to be installed and connected with the W-FM 200 via the internal safety bus. 4

O 2 probe O 2 module M Gas feed Air feed Mixing head Stepping motors Frequency convertor Inductive proximity switch Controls assembly Oil feed CAN-Bus W-FM 200 combustion manager CAN-Bus BMS visualisation rograf NT Control and Display Unit ebus 5

Capacity overview Capacity overview Burner type Version Fuel Capacity range kw kg/h 0 2000 4000 6000 8000 10000 12000 WKGL70/1-B 3LN Nat. Gas 1000 10000 Oil 1550 10000 130 840 WKGL70/2-A 3LN Nat. Gas 1100 12000 Oil 1800 12000 150 1007 The full-tone and half-tone areas together show the total ratings range. When sizing burners ensure that the required nominal rating lies within one of the full-tone areas. The stated oil throughputs refer to light oil EL with a calorific value of 11.91 kwh/kg. Nat. Gas = Natural gas E/LL Turndown on dual fuel burners Oil side: < 1:4 Gas side: < 1:8 The lower rating must lie with the capacity range of the burner. Type overview Burner type Version Regulation Capacity Oil throughput Combustion head DIN CERTCO Reg. No. Dual fuel burner for light oil up to 6 mm 2 /s at 20 C in accordance with DIN 51603 part 1, natural gases E & LL in accordance with EN 437 WKGL70/1-B 3LN modulating 1000-10000 kw 130-840 kg/h G70/2-3LN CE-0085AS0410 WKGL70/2-A 3LN modulating 1100-12000 kw 150-1007 kg/h WK70/2-3LN CE-0085AS0410 Technical equipment Technical Digital Servomotor Ignition unit Oil solenoid valve Flame sensor Weight equipment combustion manager WKGL70/1-B W-FM100 or Air damper: SQM48/20Nm Ignition Flow: 321H2522 QRI 310 kg WKGL70/2-A W-FM200 Oil regulator: SQM45 transformer Return: 121G2520 Gas butterfly: SQN45 2 x 7000 V Mixing head: SQM48/35Nm Electrical data Mains voltage Frequency Capacity Capacity Nominal load W-FM External fusing at start in operation internal fusing 230 V 50 Hz 0.5 kw 0.3 kw 1.5 A 6.3 A Slow 10 A Slow Nominal load of the fan motor: see planning documents for Weishaupt WK40 to WK70 burners, print N. 83112402 Burner fuel system (oil side) q 9 8 115V 2 2 4 115V 115V 115V M 1 Oil supply 2 Solenoid valve supply (fitted in flow direction) 3 Solenoid valve return (fitted against flow direction) 4 Nozzle head with simplex nozzle and inbuilt shut off valve (primary nozzle) 5 Nozzle head HDK30 with spillback return nozzle (secondary nozzle) 6 Oil regulating valve 7 Oil return line pressure switch 8 Oil flow line pressure switch 9 Strainer 0 Separate pump station with pressure regulator q Filter (30 bar, 0.1 mm mesh) install near burner 0 1 3 3 7 6 5 6

WKGL70/1-B, vers. 3LN Burner Burner Low pressure supply High pressure supply rating resis- (flow pressure in mbar before (flow pressure in mbar [kw] tance shut off valve before solenoid valve) (air) p e,max = 300 mbar) [mbar] Nominal diameter of valve trains Nominal diameter of valve trains 65 80 100 125 150 65 80 100 125 150 Nominal diam. of gas butterfly valve Nom. diam. of gas butterfly valve 100 100 100 100 100 100 100 100 100 100 Natural Gas E, H i = 37.26 MJ/m 3 (10.35 kwh/m 3 ), d = 0.606 5000 29 191 95 55 39 32 119 62 40 30 27 6000 29 137 80 57 46 173 90 59 45 40 7000 30 186 108 76 62 123 80 61 54 8000 34 139 97 79 159 104 78 70 9500 37 156 109 89 179 116 87 78 9000 40 173 120 98 200 129 97 86 9500 44 133 108 143 107 95 10000 49 145 118 157 117 103 Natural Gas LL, H i = 31.79 MJ/m 3 (8.83 kwh/m 3 ), d = 0.641 5000 29 134 77 53 43 171 87 56 41 36 6000 29 194 111 77 62 127 82 61 54 7000 30 151 104 85 174 112 84 74 8000 34 135 110 146 109 96 8500 37 152 123 164 122 108 9000 40 137 183 136 121 9500 44 152 151 134 10000 49 167 147 WKGL70/2-A, vers. 3LN Burner Burner Low pressure supply High pressure supply rating resis- (flow pressure in mbar before (flow pressure in mbar [kw] tance shut off valve before solenoid valve) (air) p e,max = 300 mbar) [mbar] Nominal diameter of valve trains Nominal diameter of valve trains 65 80 100 125 150 65 80 100 125 150 Nominal diam. of gas butterfly valve Nom. diam. of gas butterfly valve 100 100 100 100 100 100 100 100 100 100 Natural Gas E, H i = 37.26 MJ/m 3 (10.35 kwh/m 3 ), d = 0.606 9000 33 166 114 91 193 123 90 79 9500 36 126 101 136 100 88 10000 40 139 112 151 111 97 10500 43 153 123 166 122 107 11000 47 159 126 174 125 109 11500 52 147 199 146 129 12000 56 159 140 Natural Gas LL, H i = 31.79 MJ/m 3 (8.83 kwh/m 3 ), d = 0.641 8000 28 185 124 99 135 98 85 9000 33 156 123 170 123 107 9500 36 137 189 136 119 10000 40 151 150 131 10500 43 165 143 11000 47 180 156 11500 52 196 170 12000 56 184 Burner Version DIN-DVGW Reg. No. Valve train Order No. type and type test No. WKGL70/1-B 3LN CE-0085AS0410 DN 65 278 703 34 DN 80 278 703 44 DN 100 278 703 54 DN 125 278 703 64 DN 150 278 703 74 WKGL70/2-A 3LN CE-0085AS0410 DN 100 278 704 54 DN 125 278 704 64 DN 150 278 704 74 Fuel requirement ump type Max. at full load pump supply rate up to 500 kg/h SF / SZ 20-38 1404 l/h up to 600 kg/h SF / SZ 20-46 1890 l/h 600-1007 kg/h SF / SZ 40-38 3156 l/h This arrangement for the pump selection differs from the WK planning documents Burner resistance dependent on the burner rating at full load, with combustion air at a temperature of 20 C. The figures given for calorific value H i are based on 0 C and 1013 mbar. Note: The combustion chamber pressure in mbar must be added to the minimum gas pressure required. lease select combustion air fans from the WK40-70 lanning Documents (print No. 83112402). For low pressure supplies, pressure regulating devices with safety membrane in accordance with EN 88 are used. The maximum permissible supply pressure before the shut off valve is 300 mbar. For high pressure supplies, high pressure regulating devices in accordance with EN 3380 can be selected from the brochure ressure regulating units with safety assemblies for Weishaupt gas and dual fuel burners. This details high gas pressure sets suitable for supply pressures of up to 4 bar. Voltages and frequencies: As standard, the burners are suitable for three phase alternating current 400 V, 3 ~, 50 Hz. Other voltages and frequencies available on request at no extra cost. Standard burner motor: Isolation class B trop, I 54 protection. Additional price for isolation class F motors available on request. With DMV and W-FM 100 valve proving With 2 solenoid valves and W-FM 100/200 valve proving Isolating cock Gas filter Governor High gas pressure switch (for TRD) Low gas pressure switch W-FM 100 valve proving Double gas solenoid valve (DMV) Gas butterfly valve Gas pressure gauge and cock ilot line gas solenoid valve Burner Single gas solenoid valve 7

Dimensions Max Weishaupt GmbH 88475 Schwendi, Germany Tel. +49 (73 53) 83-0, Fax +49 (73 53) 83-358 www.weishaupt.de rint No. 83204602, december 2004 rinted in Germany. All rights reserved. Weishaupt (U.K.) Ltd Neachells Lane, Willenhall, WV13 3RG Tel: (01902) 609841, Fax: (01902) 633343 63 Carlton lace, Glasgow G5 9TW Tel. (0141) 420 2030, Fax (0141) 420 2088 www.weishaupt.co.uk b b 1 5 2 l4 l l3 l1 l2 h3 d2 d1 G 3/4" h4 h7 h2 h5 h1 h9 b4 18L connection in accordance with ISO 8434-1 b3 b5 Gas connection flange l6 l9 l8 l7 d3 30 d5 60 Burner plate drilling dimensions d4 Burner type l1 l2 l3 l4 l5 l6 l7 l8 l9 b1 b2 b3 b4 b5 WKGK70/1-B, 3LN 1690 650 315 90 475 730 1034 44 542 700 510 58 160 205 WKGK70/2-A, 3LN 1690 650 315 90 475 730 1034 44 542 700 510 58 160 205 Burner type h1 h2 h3 h4 h5 h7 h9 WKGK70/1-B, 3LN 510 628 700 978 589 450 915 WKGK70/2-A, 3LN 510 628 700 978 589 450 915 Combustion head d1 d2 d3 d4 d5 G70/2-3LN 444 520 M16 530 735 WK70/2-3LN 480 520 M16 530 735 All measurements are approximate. Weishaupt reserve the right to make alterations in light of future developments.