DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

Similar documents
Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

2 Window comparator mode. Hysteresis Hysteresis

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

A New Global Standard

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Not affected by drops, bubbles or froth

2-Color Display High-Precision Digital Pressure Switch

EX-F70 SERIES EX-F60 SERIES

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Series 10-ZSE40A(F)/10-ISE40A

High-speed detection even a little liquid leak

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Model Pressure range ON/OFF output Linear output

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

DPS280 / DVS280 Series

2-Color Display High-Precision Digital Pressure Switch

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Cylindrical Inductive Proximity Sensor GX-M SERIES

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Model Pressure range ON/OFF output Linear output

Rectangular-shaped Inductive Proximity Sensor.

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Digital display Pressure range ON/OFF output Linear output Model

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

High-frequency AC Method. panasonic-electric-works.net/sunx

19mm Thickness. Phone: Fax: Web:

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Versatile Mounting. Wide Model Variety

EX-F70 SERIES EX-F60 SERIES

CX-20. General Purpose Photoelectric Sensor with Full Basic Performance. SERIES Amplifier Built-in Compact Photoelectric Sensor PHOTOELECTRIC SENSORS

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Wide Model Variety. Versatile Mounting

2-Color Display Digital Pressure Switch

Differential Pressure Sensor

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

PX-2 SERIES. onlinecomponents.com. Compact size sensor realizes wide sensing area & long sensing range. Long Range & Wide Area Photoelectric Sensor

Indicators reveal the sort of an abnormal condition. Emitter Emitting Controller Power indicator

Digital Pressure Sensor

Related vacuum products

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting


2-Color Display Digital Pressure Switch

2-Color Display Digital Flow Switch

Low Differential Pressure Sensor ±1% F.S.

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

LCD Readout Digital Pressure Switch

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Remote Type Pressure Sensors Pressure Sensor Controllers

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

MULTISTAGE MICRO EJECTORS

Vacuum pumps/generators Small

JUMO MIDAS S05 Pressure transmitter Type

Sensor specifications Model no.

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

2-Color Display Digital Pressure Switch

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

Inductive Proximity Sensor

E2EZ-X2D1-N E2EZ-X2D2-N

Vacuum pump system type

Series PSE560 Pressure Sensor For General Fluids... 90

Electronic Circuit Breaker ESS20-0..

Inductive Proximity Sensor

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electronic Pressure Switch EDS 3000

Transcription:

Head Separated Digital Pressure Sensor SERIES /000 Second High-Speed Response Conforming to EMC Directive UL Recognition /,000 sec. The advantage of the fastest response in the industry 55

High speed in response to the needs of the times. Achieving ms response, the fastest in the industry. In response to the needs of the times, amid the continuing quest for faster and more efficient production lines, comes the series, a digital pressure sensor with a detachable head. A response time of ms makes this the fastest sensor in the industry. In addition to the high speed response time, the detachable head represents a major breakthough in terms of ease of operation and maintenance. Independent Use of Sensor Head Possible Data can be controlled by taking the analog voltage output ( to 5V) from the sensor head and feeding it to a digital panel meter. Ultra-small, Extremely Light Head (6g) Enhances Excellence and Convenience Sensor Head with Operation Indicator The sensor head is also equipped with operation indicator. Output / can be checked on the sensor head, so that it is suitable for checking operation at the suction head. (Linked to ) Convenient Intermediate Cable Intermediate cable with connectors for connecting the sensor head and the controller makes operation and maintenance easier. Easy Mounting, Mobile Pressure Port The head s pressure port can be rotated independently (free-turning) of the sensor head. In addition to being easy to mount, the cable can be laid in any direction. Standard or flexible intermediate cables are available in m, m, and 5m types. Use the flexible intermediate cable when the sensor head is attached to moving sections. 56

Super fast ms Mounting the detachable head close to the detecting section minimizes piping and enables response time of ms, the fastest in the industry, as well as greatly decreasing tact time delay. In addition, the ultra-small and light-weight design of the head means it can easily be mounted on moving sections. A Total of 0 Head Variations to Meet all Production Demands Vacuum pressure type (0 to 0.kPa) M5 male thread R (PT) /8 male thread/ M5 female thread NPT /8 male thread/ 0-UNF female thread 0-UNF male thread Positive pressure type (0 to.000mpa) M5 female thread R (PT) /8 male thread/ M5 female thread NPT /8 male thread/ 0-UNF female thread Compound pressure type ( 00.0 to 00.0kPa) M5 female thread R (PT) /8 male thread/ M5 female thread NPT /8 male thread/ 0-UNF female thread Two types of output, NPN and PNP, are available to allow use of the sensors anywhere in the world. The sensor, of course, conforms to the CE marking EMC Directive. Further, it has obtained UL recognition. Conforming to EMC Directive UL Recognition 57

Detachable head means layout freedom. Use it any way you want. Light-weight, Compact Design The controller inherits its light-weight compact design from the popular compact digital pressure sensor DP series. Control panel setup is low cost and requires minimal space. User Friendly Two-color Digital Display The user friendly two-color digital display changes color when output changes (/), making it easy to check operation status at a glance. The display color can be linked to or. Two Independent Outputs Plus Analog Voltage Output In addition to two independant outputs (/), analog voltage output ( to 5V) is also available. The different outputs allow you to create solutions for a wide variety of applications. Two Operation Indicators There are two operation indicators that light respectively when or is. They are convenient for intensive operation checks. Sensor Head Auto-recognition The head s auto-recognition function means you don t have to manually set the head type at the controller, saving you valuable time. Handy Attachments for Flexible Controller Mounting Supplied with a Panel Mounting Bracket A panel mounting bracket is enclosed to enable simple mounting of the controller onto the panel surface, thus contributing to the total cost reduction. DIN Rail Mounting Bracket Is Available The controller can be mounted even on a 5mm width DIN rail by using the optional DIN rail mounting bracket (MS-DP-). It can be fitted even in a narrow space inside your equipment because it can be mounted from four directions. Usable with a Panel Thickness of to 6mm Since the panel thickness can be from to 6mm, the controller can even be mounted on thick, resin-made panels. Selection from Six Pressure Units The pressure unit can be selected from six different systems to suit your requirement. The selectable pressure units differ with the sensor type. When the pressure unit is changed, the measured pressure value and the set values are automatically converted. inhg International System of Units (SI) kpa (Note) kgf/cm : Vacuum pressure type mmhg psi bar : Positive pressure type Note: MPa in case of combining with DPH-A0, DPH-A or DPH-A positive pressure sensor head. 58

Full Range of Functions in a Compact Body Gives You a Wide Variety of Control Options The only sensor in the industry with a leak test mode. Four output modes give you complete control. Leak test mode It is suitable for a leak test since can be set to the hysteresis mode and can be set to the window comparator mode. Using it along with the auto-reference/remote zero-adjustment functions ensures a reliable leak test. H Set Value H: digit or more H: digit Set Value H H: digits or more Set Value when using psi unit H Set Value H: digits when 0 using psi unit (Filling pressure detection) Pressure (Leak detection) Hysteresis mode The hysteresis of the comparative outputs can be set arbitrarily by the set values for / control. Window comparator mode The comparative output can be turned or by a pressure which is within the set pressure range. Forced output mode The comparative outputs are forcibly maintained at level in the sensing mode, irrespective of the set values. Hence, it is convenient for only displaying the pressure value without using the comparative outputs. Further, since the comparative outputs can be forcibly switched or with operation, without actually applying pressure, this mode is suitable for an operation check or a start-up check. Set value Set value Set value Set value 0 Pressure Set value Set value Set value Set value 0 Pressure Press Sensing mode Forced output mode H H Press Sensing mode H:digit or more digits or more when using psi unit H H H H:digit H digits when using psi unit Equipped with auto-reference and remote zero-adjustment functions. More accurate pressure control with minimal effort. If the reference pressure of the equipment changes, the auto-reference function can compensate the threshold levels by the amount of change and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired. Example: When leak test mode is applied, detects the filling pressure and detects the leakage. Without auto-reference and remote zero-adjustment functions Mode: Leak test mode (Set value: lower limit 5/upper limit 0) (Set value: lower limit 5/upper limit 0) 0 0 5 0 5 Pressure 0 Time Fixed setting Variation in the filling pressure Leak threshold level Fail? OK Filling pressure detection Fail? Trial Trial Trial Because the threshold is fixed for conventional pressure sensors, changes in the reference pressure result in wrong decisions. With auto-reference function applied (Set value: lower limit 5/upper limit 0) (Set value: lower limit 5/upper limit 0) Sets the absolute threshold level With remote zero-adjustment function applied (Set value: lower limit 5/upper limit 0) (Set value: lower limit 5/upper limit 0) Sets the absolute threshold level 0 5 Auto-reference input Trial Threshold level after applying auto-reference input OK 0 Filling pressure detection 5 The display remains at 0 and only the threshold level is changed. 0 5 0 5 Remote zero--adjustment input -5 0 Trial Threshold level after applying remote zero-adjustment input Filling pressure detection OK The display is forced to 0, and only the filling pressure drop range is displayed. Pressure0 Threshold level before applying auto-reference input Auto-reference input value 5 Time When auto-reference input is applied, the reference pressure 0 is added to the threshold level. If the reference pressure changes to 0 or 0, the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. Pressure 0 5 Threshold level before applying remote zero-adjustment input Displayed when remote zero-adjustment input is applied Time When remote zero-adjustment input is applied, the reference pressure is forced to 0. If the reference pressure changes to 0 or 0, the remote zero-adjustment input adjusts the reference pressure to 0 every time the reference pressure changes, so any variation in the filling pressure can be ignored. 59

ORDER GUIDE Pressure sensor head Type Appearance Rated pressure range (Note) Model No. Pressure port Applicable fluid Vacuum pressure Intermediate cable Compound Positive pressure pressure Appearance Standard Flexible 0 to 0.kPa 0 to.000mpa 00.0 to 00.0kPa DPH-A00 DPH-A0 DPH-A0 DPH-A0 DPH-A0 DPH-A DPH-A DPH-A07 DPH-A7 DPH-A7 Note: The rated pressure range indicates the range for full product performance. Pressure sensor controller Rated pressure range (Note) Vacuum pressure: 0 to 0.kPa Positive pressure: 0 to.000mpa Compound pressure: 00.0 to 00.0kPa M5 male thread R (PT) /8 male thread/m5 female thread NPT/8 male thread/0-unf female thread 0-UNF male thread M5 male thread R (PT) /8 male thread/m5 female thread NPT/8 male thread/0-unf female thread M5 male thread R (PT) /8 male thread/m5 female thread NPT/8 male thread/0-unf female thread Model No. -C -C-P Output NPN open-collector transistor PNP open-collector transistor Note: The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. MS-DP- OPTIS Length: m Length: m Length: 5m Length: m Length: m Length: 5m Non-corrosive gas An intermediate cable is required to connect the pressure sensor controller and the pressure sensor head. Please procure the intermediate cable separately. Intermediate cable Designation Appearance Model No. Description Panel mounting bracket (accessory) DPH-CC DPH-CC DPH-CC5 DPH-CC-R DPH-CC-R DPH-CC5-R -core cable with connector at both ends -core flexible cable with connector at both ends Designation Model No. Description Connector Connector pin 6-core cable with connector DIN rail mounting bracket Connector 6-core cable with connector DIN rail mounting bracket CN-66 CN-66-C MS-DP- Set of 0 housings and 60 connector pins Length: m 0.mm 6-core cabtyre cable with connector Cable outer diameter: ".8mm For installation to 5mm width DIN rail Housing Controller mounting bracket MS-DP- MS-DP- Controller mounting bracket MS-DP- MS-DP- Vertical mounting bracket Horizontal mounting bracket Label space You can attach a commercially available label (9 mm) in the label attaching space to display the sensor number and the sensor application. 550

SPECIFICATIS Pressure sensor head Type Item Model No. Type of pressure Rated pressure range (Note) Pressure withstandability Applicable fluid Supply voltage Current consumption Vacuum pressure Positive pressure Gauge pressure +0 to V DC 5% Ripple P-P 0% or less 5mA or less (operation indicator off) / 7mA or less (operation indicator on) Compound pressure 0kPa type MPa type ±00kPa type DPH-A00 DPH-A0 DPH-A0 DPH-A0 DPH-A0 DPH-A DPH-A DPH-A07 DPH-A7 DPH-A7 0 to 0.kPa 500kPa 0 to.000mpa 00.0 to 00.0kPa.500MPa Non-corrosive gas 500kPa Analog voltage output Output voltage: to 5V (over rated pressure range) Zero point: within V± %F.S. (vacuum/positive pressure type) within V± %F.S. (compound pressure type) Span: within V±.5%F.S. Linearity: within ± %F.S. Output impedance: kω approx. Output voltage (V) 5 Pressure High pressure (positive/compound pressure type) High vacuum (vacuum pressure type) Environmental resistance Pollution degree Protection Ambient temperature Ambient humidity EMC Voltage withstandability Insulation resistance Vibration resistance Shock resistance Operation indicator Temperature characteristics Voltage characteristics Pressure port (Industrial environment) IP0 (IEC) 0 to +50 C (No dew condensation), Storage: 0 to +60 C 5 to 85% RH, Storage: 5 to 85% RH Emission: EN5008-, Immunity: EN5008-,000V AC for one min. between all supply terminals connected together and enclosure 50MΩ, or more, with 500V DC megger 0 to 500Hz frequency, mm amplitude, or 5G in X, Y and Z directions for two hours each,000m/s acceleration in X, Y and Z directions for three times each Orange LED [lights up when is (only in case of connection to the series pressure controller)] Over ambient temperature range +0 to +0 C: within ±% F.S. of detected pressure at +5 C Over ambient temperature range 0 to +50 C: within ±% F.S. of detected pressure at +5 C Within ±0.5% F.S. for ±0% fluctuation of the supply voltage DPH-A0 : M5 male thread (for installing gasket), DPH-A : R (PT) /8 male thread/m5 female thread DPH-A : NPT /8 male thread/0-unf female thread, DPH-A0: 0-UNF male thread (for installing gasket) Material Connecting method Cable Cable extension Weight Accessories Notes: ) The rated pressure range indicates the range for full product performance. ) The pressure sensor head can be used independently. Enclosure: PBT, Pressure port: Brass (nickel plated) [however, stainless steel (SUS0) in case of DPH-A0 ] Connector 0.mm -core connector attached oil resistant cabtyre cable, 00mm long Extension up to total 0m is possible with 0.mm, or more, cable. DPH-A0 /DPH-A0: 6g approx., DPH-A /DPH-A : 0g approx. Gasket (DPH-A0, DPH-A0, only) 55

SPECIFICATIS Pressure sensor controller Item Sensor supply voltage ( ) Input Environmental resistance Suitable cable 55 Utilization category Output operation Output modes Hysteresis Repeatability Response time Type Model No. Applicable pressure sensor head Rated pressure range (Note ) Set pressure range (Note ) Supply voltage/current consumption output Short-circuit protection Pressure sensor head input Auto-reference/Remote zero-adjustment input Analog voltage output Display Displayable pressure range NPN output type -C DPH-A00, DPH-A0, DPH-A07, DPH-A0, DPH-A, DPH-A7, DPH-A0, DPH-A, DPH-A7, DPH-A0 Vacuum pressure: 0 to 0.kPa, Positive pressure: 0 to.000mpa, Compound pressure: 00.0 to 00.0kPa Vacuum pressure: 0. to 0.kPa (.0 to.0kgf/cm,.70 to.70psi,.0 to.0bar, 760 to 760mmHg, 9.9 to 9.9inHg) Positive pressure:.050 to.050mpa ( 0.7 to 0.7kgf/cm, 5. to 5.psi, 0.50 to 0.50bar) Compound pressure: 99.9 to 99.9kPa (.999 to.999kgf/cm, 9.98 to 9.98psi,.999 to.999bar, 50 to 57mmHg, 59. to 60.5inHg) +0 to V DC 5% Ripple P-P 0% or less / 60mA or less (not including pressure sensor head) Same as supply voltage NPN open-collector transistor ( outputs) Maximum sink current: 00mA Applied voltage: 0V DC or less (between comparative output and 0V) Residual voltage: V or less (at 00mA sink current) 0.V or less (at 6mA sink current) PNP open-collector transistor ( outputs) Maximum source current: 00mA Applied voltage: Same as supply voltage (between comparative output and +V) Residual voltage: V or less (at 00mA source current) NO/NC, selectable by operation Equipped with types of modes: hysteresis mode, window comparator mode, leak test mode, forced output mode (selectable by operation) digit (however, variable in hysteresis mode, variable for only when using leak test mode) With vacuum/positive pressure type sensor head: within ± 0.% F.S.± digit (± digits) With compound pressure type sensor head: within ± 0.% F.S.± digits (± 6 digits) ms, 6ms, 8ms, 5ms or less, selectable by operation (however, set response time is +ms when auto-reference/remote zero-adjustment input is applied) Input condition: NPN non-contact input [operates in Low (fall) state] Signal condition:high...5 to 0V, or open Low...0.V or less Low level input time...ms or more Output voltage: to 5V DC (over rated pressure range) Zero point: within V ±.5%F.S. (vacuum/positive pressure type) within V ±.5%F.S. (compound pressure) Span: within V ± %F.S. Linearity: within ± %F.S. Output impedance: kω approx. DC- or DC- Incorporated Input voltage range: to 5V DC (over rated pressure range) PNP output type -C-P Input condition: PNP non-contact input [operates in High (rise) state] Signal condition:high...5 to 0V Low...0.V or less, or open High level input time...ms or more / digit LCD display (with red and green backlight) (Display refresh cycle: 56ms, 5ms or ' 0ms selectable by operation) Vacuum pressure: 5. to 0.kPa (0.05 to.0kgf/cm, 0.7 to.70psi, 0.05 to.0bar, 8 to 760mmHg,.5 to 9.9inHg) Positive pressure: 0.050 to.050mpa ( 0.5 to 0.7kgf/cm, 7. to 5.psi, 0.50 to 0.50bar) Compound pressure: 0. to 05.0kPa (.0 to.07kgf/cm,.70 to 5.psi,.0 to.050bar, 760 to 787mmHg, 9.9 to.0inhg) Operation display LCD segment is red when comparative output is, and green when it is (output is selected via supplementary settings) Analog bar display Bar display in steps of % F.S. approx. Operation indicator Orange LED (lights up when is ), Green LED (lights up when is ) Pollution degree (Industrial environment) Protection IP0 (IEC) Ambient temperature 0 to +50 C (No dew condensation), Storage: 0 to +60 C Ambient humidity 5 to 85% RH, Storage: 5 to 85% RH EMC Emission: EN5008-, Immunity: EN5008- Voltage withstandability,000v AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50MΩ, or more, with 500V DC megger between all supply terminals connected together and enclosure Vibration resistance 0 to 50Hz frequency, 0.75mm amplitude, or 5G in X, Y and Z directions for two hours each Shock resistance 00m/s acceleration in X, Y and Z directions for three times each Temperature characteristics Over ambient temperature range 0 to +50 C: within ±0.5% F.S. of detected pressure at +5 C (not including pressure sensor head) Material Front case: ABS, LCD display section: PET, Rear case: PBT Connecting method Connector Conductor cross-section area (Note ) 0.6 to 0.mm (AWG#5 to #) Lead wire diameter ". to ".8mm Wire material Tin plated, soft, twisted copper wire Cable extension Extension up to total 00m is possible with 0.mm, or more, cable. Weight 0g approx. Accessories Panel mounting bracket (MS-DP-): set, Connector: set (Housing: No., Connector pin: 6 Nos.), Pressure unit label: No., Connector cap: No., Notes:) The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. ) If the wiring is longer than m, use a cable with a diameter of 0.mm or more. Output voltage (V) 5 Pressure High pressure (positive/compound pressure type) High vacuum (vacuum pressure type)

I/O CIRCUIT AND WIRING DIAGRAMS -C I/O circuit diagram Sensor head main circuit Sensor head internal circuit Symbols... D, D: Reverse supply polarity protection diode ZD to ZD: Surge absorption zener diode Tr, Tr: NPN output transistor Pin position Terminal No. Intermediate cable NPN output type +V D D Type setting/ indicator kω ZD Analog voltage input 0V Controller main circuit Tr ZD Tr kω ZD ZD Controller internal circuit Terminal No. Color code of cable with connector (Brown) + V (Pink) Auto-reference/ Remote zero-adjustment input 6 (Gray) Analog voltage output Load (Black) (White) 00mA max. 5 00mA max. (Blue) 0V Users circuit Load + to V DC +0 % 5 For independent use of Sensor head Main circuit D kω ZD (Brown) +V (White) N.C. (Note) (Black) Analog voltage output ( to 5V) Terminal No. Color code (Blue) 0V + to V DC +0 % 5 Sensor head internal circuit Users circuit Note: In case the pressure sensor head is used independently, insulate the white wire (Terminal No.) and keep it open. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Connector for pressure sensor head connection 5 6 Connector for power supply/ I-O cable connection Connector for power supply/ I-O cable connection 5 6 +V Analog voltage output 0V Auto-reference/ Remote zero-adjustment input Connector for pressure sensor head connection +V Analog voltage output 0V N.C. -C-P I/O circuit diagram PNP output type Sensor head main circuit D kω ZD Terminal No. +V Terminal No. Color code of cable with connector (Brown) +V Type setting/ D (Pink) Auto-reference/ indicator Remote zero-adjustment input 6 (Black) Analog 00mA max. ZD voltage Tr input Tr ZD 00mA max. 5 (White) Load kω (Gray) Analog Load voltage output 0V ZD (Blue) 0V Controller main circuit + to V DC +0 % 5 Sensor head internal circuit Intermediate cable Controller internal circuit Users circuit Symbols... D, D: Reverse supply polarity protection diode ZD to ZD: Surge absorption zener diode Tr, Tr: PNP output transistor Pin position Connector for pressure sensor head connection 5 6 Connector for power supply/ I-O cable connection Connector for power supply/ I-O cable connection 5 6 +V Analog voltage output 0V Auto-reference/ Remote zero-adjustment input Connector for pressure sensor head connection +V Analog voltage output 0V N.C. 55

PRECATIS FOR PROPER USE This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal pressure detection sensor. The DPH series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. Functional description Error messages When an error occurs, take the following corrective action. Error message Cause Corrective action The controller, pressure sensor head and the intermediate cable are not correctly connected. Pressure sensor head cable or intermediate cable have a cable break. Connect the pressure sensor head and the intermediate cable correctly. Check the pressure sensor head cable and the intermediate cable and replace the cable having a break. OUT OUT The pressure sensor head is damaged. Overcurrent due to shortcircuit. Replace the pressure sensor head. Switch off the power supply and check the load. Description / digit LCD display with red and green ( backlight ) operation indicator (Orange) operation indicator (Green) Connector for power supply/ I-O cable connection Connector for pressure sensor head connection Function Displays measured pressure, settings, error messages and -protect status. Its lighting up can be set as Red when /Green when with respect to either Output or, according to the backlight relation selection during the supplementary setting mode. Lights up when is. Lights up when is. In the initial setting mode and supplementary setting mode, pressing the changes the setting item. In the pressure value setting mode, pressing the changes the set value. In the sensing mode, pressing the continuously for sec., or more, displays the peak hold value. In the initial setting mode and supplementary setting mode, pressing the changes the set conditions. In the pressure value setting mode, pressing the changes the set value. In the sensing mode, pressing the continuously for sec., or more, displays the bottom hold value. In the sensing mode, if both s are simultaneously pressed continuously, zero-point adjustment is done. In the pressure value setting mode, pressing the changes the setting item. In the sensing mode, pressing the continuously for sec., or more, can set/cancel the -protect. In the sensing mode, pressing both and simultaneously changes the mode to the initial setting mode. Whereas, pressing both and simultaneously changes the mode to the supplementary setting mode. It is the connector for connection of power supply/i-o cable. It is the connector for connection of pressure sensor head. Wiring Make sure to carry out the wiring in the power supply off condition. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this controller, connect the frame ground (F.G.) terminal of the equipment to an actual ground. If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. In order to reduce noise, make the wiring as short as possible. Take care that wrong wiring will damage the sensor. Others Pressure is being applied during zero-point adjustment. Positive Applied pressure exceeds the upper limit pressure and compound of displayable pressure pressure types range. Vacuum pressure type Positive pressure and compound pressure types Vacuum pressure type Applied pressure exceeds the lower limit (reverse pressure) of displayable pressure range. Applied pressure exceeds the lower limit (reverse pressure) of displayable pressure range. Applied pressure exceeds the upper limit of displayable pressure range. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. Applied pressure should be brought within the rated pressure range. Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (: sec. approx., DPH: 50ms approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the s with pointed or sharp objects. 55

PRECAUTIS FOR PROPER USE Setting If -protect has been set, make sure to release -protect before operating the s. [Please refer to Key-protect function on P. for the procedure.] Pressure value setting can be done only if the output mode is set to the hysteresis mode, window comparator mode or the leak test mode. Pressure values cannot be set if the output mode is set to the forced output mode. Set Values P- to P- can be common for all the output modes. In the positive pressure type and the compound pressure type, Set Value P- can be set only towards the higher pressure side with respect to Set Value P- and Set Value P- can be set only towards the higher pressure side with respect to Set Value P-. Further, in the vacuum pressure type, Set Value P- can be set only towards the higher vacuum side with respect to Set Value P- and Set Value P- can be set only towards the higher vacuum side with respect to Set Value P-. The auto-reference function affects only Set Value P- and Set Value P-. Set Value P-A is the pressure value when the auto-reference input or the remote zero-adjustment input is applied. When the auto-reference input or the remote zero-adjustment input is not applied, Set Value P-A is zero. The set conditions are written and stored into an EEPROM. However, note that the EEPROM has a life span and its guaranteed life is 00,000 write operation cycles. Further, since the auto-reference input value and the remote zero-adjustment input value are not stored in the EEPROM, they are not included in the number of write operation cycles. Setting procedure Sensing mode Zero-adjustment + Press continuously Zero-adjustment Adjust zero point. Release the s when 000 is displayed Sensing mode Initial setting mode Display mode, Output mode and Unit are set. + Supplementary setting mode + Display mode Digital display Analog display NO/NC selection ( ) : NO : NO : NC : NO : NC : NC : NO : NC NO/NC, Display cycle, Response time, Pressure range, Display color relation and Auto-reference/Remote zero-adjustment are set. Display cycle selection ( ) Output mode Hysteresis mode Window comparator mode Leak test mode Forced output mode,000kpa Note: Only when positive type sensor head is connected. Sensing mode Response time Pressure range Display color relation selection ( ) selection ( ) selection ( ) 56ms ms MPa 5ms,0ms 6ms 8ms 5ms kpa or MPa Unit kgf/cm bar psi Positive pressure type inhg mmhg Vacuum pressure type, compound pressure type Auto-reference/Remote zero-adjustment selection ( ) Auto-reference function Remote zeroadjustment function Sensing mode Pressure value setting mode Enter Set Value P- using and. Set Values P- to P- are set. Enter Set Value P- using and. Enter Set Value P- using and. Enter Set Value P- using and. Enter Set Value P- Enter Set Value P- Enter Set Value P- Enter Set Value P- Measured value at the time of auto-reference input/remote zero-adjustment input is displayed. (Initial value is zero.) Display Set Value P-A Sensing mode 555

PRECAUTIS FOR PROPER USE Auto-reference function Auto-reference function corrects Set Value P- and Set Value P- of by taking the pressure measured at the time of auto-reference input as the reference pressure. <Before auto-reference input> When there is no auto-reference input, the atmospheric pressure is taken as the reference pressure for Set Value P- and Set Value P-. <After auto-reference input> Atmospheric pressure Auto-reference input Pressure change Atmospheric pressure P- P- Pressure P-A P- P- Pressure P- =P-+P-A P- =P-+P-A At the time of auto-reference input, the pressure value detected at that instant is temporarily recorded as Set Value P-A and becomes the reference pressure. With Set Value P-A as the reference pressure, Set Value P- and Set Value P- are automatically corrected to Set Value P- + Set Value P-A and Set Value P- + Set Value P-A, respectively. Settable range and set pressure range after correction The settable range of Set Value P- and Set Value P- is wider than the rated pressure range to cater to the auto-reference function. At the time of auto-reference input, if the corrected set value exceeds the set pressure range, the set value is automatically corrected to be within the set pressure range. Hence, please see that the set pressure range is not exceeded. Operation chart <Normal operation (comparative outputs set to NO)> Applied pressure (kpa) 0 0 0 0 0 50 60 70 80 90 00 Display value (kpa) 0 0 0 0 0 50 60 70 80 90 00 Set value (kpa) <With auto-reference input (comparative outputs set to NO)> Auto-reference input: 50kPa Output mode: Hysteresis mode Applied 0 0 0 0 0 50 60 70 80 90 00 pressure (kpa) Display value (kpa) 0 0 0 0 0 50 60 70 80 90 00 Set value (kpa) P- P- P- P- 0 0 0 0 P- P- P-A P- P- 0 0 50 80 90 Note: As in the case of the hysteresis mode, Set Value P- and Set Value P- are shifted also in case the output is set to the window comparator mode or the leak test mode. Maintain the pressure at a constant level for at least ms after the auto-reference input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use at least set response time + ms after the auto-reference input is made Low (High in case of PNP output type). At the time of auto-reference input, is displayed on the / digit display for sec. approx. The auto-reference input value (Set Value P-A) becomes zero when the power supply is switched off and then on again. Although it is not possible to display the corrected Set Value P- and Set Value P-, it is possible to display the auto-reference input value (Set Value P-A). 556

PRECAUTIS FOR PROPER USE Remote zero-adjustment function The remote zero-adjustment function forcibly sets the pressure value at the time of application of an external input signal to zero. At the time of remote zero-adjustment input, the set values are not corrected. When using the remote zero-adjustment function, make sure that the pressure and the set values do not exceed the rated pressure range. Operation chart Normal operation (comparative outputs set to NO) Applied pressure (kpa) Display value (kpa) Set value (kpa) Applied pressure (kpa) Display value (kpa) Set value (kpa) With remote zero-adjustment input (comparative outputs set to NO) Remote zero-adjustment input: 50kPa Output mode: Hysteresis mode Applied pressure (kpa) 0 0 0 0 0 50 60 70 80 90 00 Display value (kpa) 50 0 0 0 0 0 0 0 0 0 50 P- P- P- P- Set value (kpa) 0 0 0 0 Note: As in the case of the hysteresis mode, the displayed values and the / points of the output are shifted also in case the output mode is set to the window comparator mode. Remote zero-adjustment input: 50kPa Output mode: Leak test mode 0 0 0 0 0 50 60 70 80 90 00 0 0 0 0 0 50 60 70 80 90 00 P- P- P- P- 0 0 0 0 0 0 0 0 0 50 60 70 80 90 00 50 0 0 0 0 0 0 0 0 0 50 P- P- 0 0 P- P- 0 0 Note: In the leak test mode, the zero-adjustment function is applied only to. operates with the atmospheric pressure as the reference. Maintain the pressure at a constant level for at least ms after the remote zero-adjustment input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use the comparative outputs at least set response time + ms after the remote zero-adjustment input is made Low (High in case of PNP output type). At the time of remote zero-adjustment input, is displayed on the / digit display for sec. approx. If the power supply is switched off and then on again, the remote zero-adjustment input value is cleared and the sensor returns to normal operation with atmospheric pressure as the reference. Forced output mode In the initial setting mode, if the output mode is set to the forced output mode ( ), the comparative outputs are forcibly maintained at level in the sensing mode, irrespective of Set Values P- to P-. Further, if the s are operated as per the procedure given below, the comparative outputs can be forcibly switched either or without applying pressure at the pressure port. This is convenient for an operation check of the comparative outputs or for an inspection before commencing work. The diagram below appears when the -C has been used to set the display to Digital display ( ). In the sensing mode, press to change to the OUT forced output mode. OUT Each time is pressed, switches to and, alternately. Each time is pressed, switches to and, alternately. Press to return to the sensing mode. Output is kept off at the point where the mode is changed from another output mode to forced output control mode ( ). Even if output has been set to stay on during forced output control mode, it will be forcibly changed to off at the point where the mode changes back to sensing mode. Peak hold & bottom hold functions Peak hold and bottom hold functions enable the display of the peak value (maximum pressure value) and the bottom value (minimum pressure value) of the varying measured pressure. These functions are convenient for finding the pressure variation range or determining the reference for pressure settings. Please note that the peak value and the bottom value data is erased when it is no longer displayed. OUT OUT OUT OUT OUT Displayed alternately OUT OUT Displayed alternately OUT Peak hold display In the sensing mode, keep pressed until is displayed. ( sec. or more) When the finger is released after is displayed, the peak value and are displayed alternately. Press. If the applied pressure exceeds the displayable pressure range, error message ( or ) and are displayed alternately. In this case, bring back the applied pressure to within the rated pressure range. The figure on the left shows the display of a vacuum type sensor. Bottom hold display In the sensing mode, keep pressed until is displayed. ( sec. or more) When the finger is released after is displayed, the bottom value and are displayed alternately. Press. If the applied pressure exceeds the displayable pressure range, error message ( or ) and are displayed alternately. In this case, bring back the applied pressure to within the rated pressure range. The figure on the left shows the display of a vacuum type sensor. 557

PRECAUTIS FOR PROPER USE Key-protect function Key-protect is a function which prevents any unintentional change in the conditions which have been entered in each setting mode by making the sensor not to respond to the operations. OUT OUT Setting of -protect In the sensing mode, press continuously for sec., or more, and release it immediately when is displayed. Key-protect is set and the sensor returns to the ( sensing mode. ) Since the -protect information is stored in an EEPROM, it is not erased even if the power supply is switched off. Please take care to remember if the -protect function has been set. Connecting To connect the pressure sensor head to the pressure controller, the optional intermediate cable (DPH-CC ) must be used. Take care that stress is not directly applied to the cable joint or the connector. If the pressure sensor head is to be mounted on a movable part, make sure to use a flexible intermediate cable. When connecting the intermediate cable to the pressure controller, make sure to fit the connector cap, supplied as an accessory with the pressure controller, by sliding it as shown in the figure below. If the connector cap is not fitted, there is a danger of the intermediate cable getting disconnected from the sensor. OUT OUT In the sensing mode, press continuously for sec., or more, and release it immediately when is displayed. Key-protect is released and the sensor returns ( ) to the sensing mode. When the s are to be operated, make sure that -protect is released. Connector cap Release of -protect Piping When connecting a commercial coupling to the pressure port, hold the hexagonal section of the pressure port with a mm (DPH-A, DPH-A : mm) spanner, and make sure that the tightening torque is N m (male thread type of DPH-A, DPH-A : 5N m) or less. If excessive tightening torque is applied, the M5 male thread of the commercial coupling or the pressure port will get damaged. Mounting Install the enclosed panel mounting bracket (MS-DP-) as shown in the figure below. The tightening torque should be 0.5N m or less. Further, tighten both the right and the left screw gradually and equally, so that the panel mounting bracket does not tilt. M (length 5mm) panel fixing screw (Accessory) Panel mounting bracket (MS-DP-) (Accessory) DIMENSIS (Unit: mm) -C / digit LCD display (Green and red) operation indicator (Orange) Pressure controller OUT 0 OUT Increment 0 7 (6) 9 Connector for pressure sensor head connection 6.5 Connector for power supply/ I-O cable connection Mode selection Decrement operation indicator (Green) Connector cap 6.5 558

DIMENSIS (Unit: mm) DPH-A0 DPH-A0 Sensor head DPH-A DPH-A Sensor head.5 ().5 () 8.5 8.5 0 5 00 (8.5) 0 5 (00) (8.5) 0.5 6.5 Pressure port DPH-A0 : M5 male thread DPH-A0: 0-UNF male thread ".7 cable 5.5 6.5 Pressure port DPH-A : R /8 male thread/m5 female thread DPH-A : NPT /8 male thread/0-unf female thread 9.5 (0) ".7 cable Operation indicator (Orange) Operation indicator (Orange) MS-DP- Panel mounting bracket (Accessory) Assembly dimensions 56 9 0 Panel cut-out dimensions 60 (.55) 0.9 OUT OUT 7 +0.5 0 7 6 7 +0.5 0 7 +0.5 0 X +0.5 0 Panel fixing screw Material: POM Two M (length 5mm) screws for fitting are attached. X when n unit is installed X = 0 (n ) + 7mm Note: The panel thickness should be to 6mm. MS-DP- DIN rail mounting bracket (Optional) Assembly dimensions Horizontal mounting Variable range Vertical mounting -".5 mounting holes 9 0 (0) 6 Suitable for 5mm width DIN rail 0 5 OUT OUT -".5 mounting holes 9 0 5 0 0 6 5 Suitable for 5mm width DIN rail Variable range (0) 0 5 OUT OUT 0 5.9 559

DIMENSIS (Unit: mm) DPH-CC Intermediate cable (Optional) L (7.) (.7) (6) ".7 cable Note: The heat-shrink tube for the standard cable is black, and the heat-shrink tube for the flexible cable is gray. (0.5) Model No. DPH-CC (-R) DPH-CC (-R) DPH-CC5 (-R) Cable length m m 5m CN-66 Connector (Optional) CN-66-C Cable with connector (Optional) Housing Connector pin (7.) (.9) (9.5),000 (50) (.5) (6.9) (6.5) (5.7) XAP-06V- manufactured by J.S.T. MFG CO., LTD. ".8 cable (9.5) (.) Connector Connector pin: BXA-00T-P0.6 manufactured by J.S.T. MFG CO., LTD. Housing: XAP-06V-0 manufactured by J.S.T. MFG CO., LTD. (5.8) Crimping tool: YC-690R manufactured by J.S.T. MFG CO., LTD. MS-DP- Controller mounting bracket (Optional) MS-DP- Controller mounting bracket (Optional) -".5 mounting holes 57 0 57 7 65 7 t R6 0 6 ".5 mounting holes 9.75 7 6.5 7 8 6 0.5 t Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Note: Use together with panel mounting bracket included with sensor. Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Note: Use together with panel mounting bracket included with sensor. 560