From Pure to Sterile MAIN FEATURES & BENEFITS: Highly robust and mechanically stable Very durable design Integrity testable according to HIMA Thermal stability up to 200 C Approved for Food Contact Use acc. to CFR Title 21 & EEC/1935/2004 INDUSTRIES: Dairy Brewery Food Processing Pharmaceutical Chemical Packaging Donaldson Filtration Deutschland GmbH Büssingstr. 1 42781 Haan Germany Web: www.donaldson.com
PRODUCT DESCRIPTION The filter is a wrapped depth filter with inner and outer guard and end caps made from stainless steel. The retention rate is >/= 99,99998 % related to </= 0,2 μm. The binder-free, three dimensional borosilicate depth media has a large void volume of 95 %. This ensures a high dirt containment capacity at a low differential pressure and a high flow rate. The filter media is inherently hydrophobic. The was developed for the safe sterile filtration of compressed air and other process gases. The filter element fulfils the high requirements in food (breweries, dairies, soft drinks) and pharmaceutical industries and works reliable even under extreme operating conditions. Based on the binder free micro fibre medium made of borosilicate, this depth type filter realises high particle holding capacity and long service life. The wrapped sterile depth filter is designed and developed for the following applications: Filtration of air and gases Compressed Air Carbon Dioxide Fermentation Air Tank Ventilation Technical Gases Application areas Chemical industry Pharmaceutical industry Biotechnology All components meet the EU and USA requirements for Food Contact Use in accordance with CFR (Code of Federal Regulations) Title 21 and EEC/1935/2004. Several layers of the glass fibre medium are embedded in stainless steel supports and bound to stainless steel end caps. The sturdy stainless steel construction permits one hundred (100) possible sterilisation cycles at specified conditions and withstands high differential pressures in both flow directions. (P)- SRF sterile filter elements guarantee a safe and reproducible production. Breweries Dairies Aseptic packaging Food industry Hospitals - 2 - PRODUCT DESCRIPTION
PRODUCT SPECIFICATIONS Product Specifications Retention Rate >/= 99,99998 % at </= 0,2 µm Filtration Surface Temperature Range 0,05 m 2 per 250 mm element (10 ) -20 C (-4 F) to 200 C (400 F) > 150 C (300 F) only for dry air Maximum Differential Pressure Typical Continuous Air Service Life time Typical Vent Service Life Time 5 bar (75 psid), independent of the system pressure or the flow direction 12 months 6 months Cumulative Steaming Time* 121 C (250 F), Saturated Steam: > 100 cycles (30 minutes) * Figures are based on lab tests to evaluate steaming resistance. Filter elements need to be checked in actual use. Contact Donaldson for recommended Autoclaving/Steaming procedures. SAMPLE INSTALLATION (REVERSE FLOW STERILISATION) P1 T1 V5 SRF SRF N S AK compressed filter filter air / gas P A V2 V3 V4 P2 V7 T2 V8 V6 to proces P-GS 1µm (5µm) 2bara 121 C V1 Steam P A - 3- PRODUCT SPECIFICATIONS & SAMPLE INSTALLATION
MATERIAL COMPLIANCE All components of the filter element are FDA listed for food contact use in the Code of Federal Regulations (CFR), Title 21 Filter Materials CFR Title Filter Matrix: Borosilicate 177.2260 Upstream Support: PTFE 177.1550 Downstream Support: Outer Guard: Inner Guard: End Caps: Bonding Materials: PTFE 177.1550 Stainless Steel 1.4301 211.65 Stainless Steel 1.4301 211.65 Stainless Steel 1.4301 211.65 Silicone 177.2600 O-Rings: Alternatively: Silicone Buna EPDM PTFE over silicone PTFE over viton 177.2600 177.2600 177.2600 177.1550 177.1550 All products have been inspected and released by Quality Assurance as having met the following requirements: Donaldson Filtration Deutschland GmbH confirms that all materials used for the P- SRF element meet regulatory and legislative requirements and guidelines for food contact as detailed in European Regulation (EC) Number 1935/2004. These articles are intended for indirect food use in filtration of gases, therefore migration testing has been limited to an atmospheric and watery environment. All sterile filters are integrity tested according to ASTM D 2986-91 and DIN EN 1822. to verify compliance with established quality and design specifications and to assure consistent and reliable performance. On request a Factory Test Certificate according to DIN EN 10204 is available. - 4 - MATERIAL COMPLIANCE
FLOW CHARACTERISTICS, 10/30, air, 25 C, 1 bar absolute & 8 bar absolute 400 Differential Pressure [mbar] 350 300 250 200 150 100 50 8 bar absolute 1 bar absolute 0 0,0 20,0 40,0 60,0 80,0 100,0 120,0 Flow [m3/h] AVAILABLE END CAP CONFIGURATIONS Dimensions (CODE 7 connection) : CODE 7 Size a b c mm inch mm inch mm inch 5 125 4,92 190 7,48 56,5 2,22 10 250 9,84 315 12,40 56,5 2,22 20 500 19,68 585 22,24 56,5 2,22 30 750 29,53 815 32,08 56,5 2,22 CODE 7: 2 x 226 o-rings, bayonet 2 locking tabs, locating fin. - 5 - FLOW CHARACTERISTICS & AVAILABLE END CAPS
Dimensions (uf plug connection): uf plug Connection Size a b C* CF** mm inch mm inch mm inch 03/10 76 2,99 87 3,42 30 1,18 0,12 04/10 104 4,09 118 4,64 30 1,18 0,17 04/20 104 4,09 118 4,64 37 1,46 0,19 05/20 128 5,04 142 5,59 37 1,46 0,25 05/25 128 5,04 142 5,59 37 1,46 0,32 07/25 180 7,08 194 7,64 37 1,46 0,47 05/30 128 5,04 144 5,67 61 2,40 0,46 07/30 180 7,08 196 7,71 61 2,40 0,68 10/30 254 10 270 10,63 61 2,40 1,00 15/30 381 15 397 15,63 61 2,40 1,55 20/30 510 20 526 20,63 61 2,40 2,10 30/30 764 30 780 30,63 61 2,40 3,28 30/50 764 30 780 30,63 89 3,50 5,89 * Plug- type connection with double-o-ring ** Correction Factor Filtration Surface & Flow Rate Dimensions (thread connection): thread connection Size a b c mm inch mm inch 2/1,5 66 2,598 76 2,992 1½ x1 1/16 m 3/1,5 76 2,992 86 3,386 1½ x1 1/16 m 4/1,5 112 4,409 122 4,803 1½ x1 1/16 m 4/2,5 103 4,055 127 5,000 R1 5/2,5 127 5 151 5,945 R1 5/3 127 5 149 5,866 R1 10/3 254 10 376 10,866 R1 15/3 381 15 407 16,024 R2 20/3 508 20 537 21,142 R2 30/3 762 30 788 31,024 R2 30/5 762 30 782 30,787 R3 Other end cap configurations on request. Technical alterations reserved 04/2009 Integrity test of this element to be done by DOP Test. For information on test equipment or test services, please contact your Donaldson Sales Engineer and visit our website at www.donaldson.com! (Rev 04 09/10)