UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Similar documents
IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

INSTRUCTIONS FOR INSTALLATION

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

ELECTRONIC CONTROL PANEL FOR ONE 230VAC MOTOR TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

Automatic concealed bollards 275 H600 and 275 H800 with pit

TECHNICAL DATA HYDRAULIC UNIT

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

BULL 424 ESA BULL 624 ESA

Automatic concealed bollards 275 H600 and 275 H800 Control station

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

INSPECTIONS AND MAINTENANCE

Automation Swing Gate Opener

GENERAL SAFETY... 3 PARTS LIST...

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Typical Installation Schematic

UNIK2E _ V2 (COMPLETE) UNIK2ESK _ V2 (WITHOUT BOX AND TRANSFORMER)

Ditec CUBIC Swing gates automation

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

EC DECLARATION OF CONFORMITY

FITTING AND CONNECTION INSTRUCTIONS

E R A I GATE AUTOMATION DIVISION

Installation Manual. Swing Gate System. Leading the way...

ARACHNE 230V 24V- 12V

Ditec PWR25H/35H Automation for hinged gates

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Ditec LUXO Swing gates automation (Original instruction)

CE DECLARATION OF MACHINE CONFORMITY

SWING GATE OPENERS 24V DC GEAR MOTOR

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

E R A I Gate Openers Department

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

SWING GATE OPENERS 24V DC GEAR MOTOR

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Oil-hydraulic operator for swinging gates

USE AND INSTALLATION HANDBOOK

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

TURBO 40 TURBO 80 TURBO 120 TURBO 160

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

SLIDE NEW CONTROL BOARD

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

BISON 20 OM BISON 25 OTI

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

Ditec BOX Balanced up and over doors

Porte 150 Users Manual Swing Gate Opener 24V DC

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

USER INSTRUCTIONS FOR SLIDING DOORS

INSTALLATION MANUAL GB

Ditec DOD Industrial sectional door automations

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

SLIDING GATE OPENER USER MANUAL

LINCE 300/400/600. User s and Intaller s manual

Ditec PWR50H/HV/HR Automation for swing gates

Entrematic Ditec Sprint 24V

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

IMPORTANT NOTICE FOR THE INSTALLER

Mod: KLD6-12/35XLAS-N

FORCE SPD 800/1500/2000

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

FEATURES AND SPECIFICATIONS

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

GB Instructions Manual

UMPETHA U / Domestic sliding gate operator by ET SYSTEMS. USER GUIDE

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec SPRINT Swing doors drive unit

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

BARRY BARRIER GATE AUTOMATION

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

Switching DC Power Supply

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

Transcription:

UNDERGROUND OPERATOR FOR SWINGING GATES COMPAS 2 WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable to evaluate risks, comply with norms UNI EN 12453, EN 12445 The CE mark conforms to European directive EEC 89/336 + 92/31 + 93/68 D.L. 04/12/1992 N. 476.

PACKING CONTENTS... 2 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS... 3 TECHNICAL DATA... 3 DIMENSIONS... 4 TYPICAL CONNECTION AND CABLE SECTION... 4 CONSIDERATIONS FOR INSTALLATION... 5 INSTALLATION... 5-6 TROUBLESHOOTING... 7 SAFETY PRECAUTIONS... 8 PACKING CONTENTS 1- UNDERGROUND OPERATOR 1- SIMPLE LEVER FOR WING ANCHORAGE 1- UNLOCKING KEY 1- CONDENSER (230VCA)

VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS 3 2 7 4 6 5 8 1 5 1 2 Optimal installation 1- Operator 2- External photocell 3- Flashing warning light 4- Antenna 5- Internal photocell 6- Electronic control unit 7- Key-switch 8- Remote control TECHNICAL DATA 24V 230V Max. weight of gate 200 Kg Max. width of gate 2,50 mt Motors power supply 24Vdc 230 Vac Motor power 50 W 280 W Motor RPM 1800 1400 Condenser / 16 µf Mechanical unlock for emergency With key manoeuvre Working temperature -20 C / +55 C weight 13 Kg Protection rating IP 67 Opening time 90 15 sec Motor current input 3 A 1,4 A

148 mm 200 mm DIMENSIONS 384mm 270 mm 258 mm TYPICAL CONNECTION AND CABLE SECTION 2X1,5mm2 (24 Vdc ) 4X1,5mm2 (230 Vca ) 2X0,75mm2 4X0,75mm2 RX Photocell TX Photocell 2X0,75mm2 4X0,75mm2 3X1,5mm2 230V Line CONSIDERATIONS FOR INSTALLATION The installation and testing operations must be performed solely by qualified personnel in order to guarantee the proper and safe operation of the automatic gate. The company declines any responsibility for damage caused by incorrect installations due to incompetence and/or negligence. Before assembling the automatism, check that the gate is in perfect working order, hangs well on its hinges and is suitably lubricated. It must also comply with the safety standards in force in the country of installation.

INSTALLATION Introductory note: Dig a hole big enough to hold the operator, calculate the required opening angle considering that the Compass operator can also be installed Out of Axis, insert the sheath for laying the power cable, and cement solidly. GATE WING OPENING ANGLE Establish the required opening angle opportunely positioning the opening locks for the shutters. INSTALLATION PROCEDURE Establish where the operator is to be installed Prepare the sheath for laying the power cable Execute the splice of the cable one watertight box Watertight box Sheathing Place the operator into the hole, position and level it so that there is a distance of 85mm (see pict.) between ground level and the gate wing, cement firmly and wait for it to dry before assembling the levers. 75mm min 85mm min

Insert and fasten the lever on the toothed pinion of the operator 21,5mm 410mm 160mm 50mm Fix the bracket to the gate, then to the lever with the seeger and washer. Gate bracket Lever Seeger Washer MECHANICAL END STOP (OPTIONAL) It is possible to install the mechanical end stop either in opening or in closing setting the two bolts. Bolts EMERGENCY RELEASE PROCEDURE In order to release the swing of the gate you may insert and turn the key which is on the pivot of the anchoring lever motor reducer/gate

TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION 230 volt mains voltage absent Check master switch On giving a command with the remote control or with the key-switch, the gate doesn t open or the motor doesn t start On giving a command with the remote control, the gate doesn t open but works with the key command The gate starts, but stops immediately One wing opens and the other closes Emergency STOP present Fuse blown Power cable of motor or motors not connected or faulty. The photocell is not functioning or the beam is interrupted The remote control has not been memorised or the battery is flat The force of the motor or motors is insufficient The connection is not correct Check for any STOP selectors or commands. If not used, check jumper on STOP contact input on the control board Replace with one of same value. Connect the cable to appropriate terminal or replace. Check the connection, remove any obstacle across the beam Carry out the remote control learning procedure on the radio receiver or replace the battery with a new one.. Modify the value with the FORCE trimmer on the control unit Invert the connection of the cable of the motor which rotates in the wrong sense N.B. - If the problem persists, contact your Retailer or the nearest Service Centre

SAFETY PRECAUTIONS These warnings are an essential, integral part of the product and must be given to the user. They provide important indications on the installation, use and maintenance and must be read carefully. This form must be preserved and passed on to subsequent users of the system. The incorrect installation or improper use of the product may be dangerous. INSTALLATION INSTRUCTIONS The installation must be performed by professionally skilled personnel and in compliance with current local, state, national and European legislation. Before beginning the installation, check the integrity of the product. The laying of cables, electrical connections and adjustments must be workmanlike performed. The packing materials (cardboard, plastic, polystyrene, etc.) are a potential hazard and should be disposed of correctly and not left within reach of children. Do not install the product in potentially explosive environments or environments disturbed by electromagnetic fields. The presence of inflammable gases or fumes is a grave danger to safety. Set up a safety device for overvoltage, a disconnecting and/or differential switch suitable for the product and conforming to current standards. The manufacturer declines any and all responsibility for product integrity, safety and operation in the event incompatible devices and/or components are installed. Solely original spare parts should be used for repairs and replacements. The installer must provide all the information relating to the operation, maintenance and use of the individual parts, components and system as a whole. WARNINGS FOR THE USER Read the instructions and enclosed documentation carefully. The product must be used for the express purpose for which it was designed. Any other use is considered improper and therefore hazardous. In addition, the information given in this document and in the enclosed documentation may be subject to modifications without prior notice. It is given as an indication only for product application. The company declines any responsibility for the above. Keep products, devices, documentation and anything else provided out of reach of children. In the event of maintenance, cleaning, breakdown or faulty operation of the product, cut off the power and do not attempt to operate on the product. Contact solely the professionally skilled personnel responsible for these operations. Failure to adhere to the above indications may be dangerous. The data and images are for guidance only VDS reserves the right to change at any time characteristics of the products described in its sole discretion, without notice. Via Circolare p.i.p. N 10 65010 Santa Teresa di Spoltore (PE) - ITALY Tel. +39 085 4971946 - FAX +39 085 4973849 www.vdsconsorzio.it - vds@vdsconsorzio.it Rev. 1-09/10 ING