Cast Resin Transformers

Similar documents
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

DRY TYPE TRANSFORMERS

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

The construction features of EdM transformers

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

Ecodesign Transformers Energizing the World since a company of Rauscher & Stoecklin SERW ZREW Tesar

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Green T.HE. High efficiency Transformers. THE Global specialist in electrical and digital building infrastructures

ORION PLUS three-phase kVA

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

LV Capacitor CLMD Reliability for Power Factor Correction

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Key features. DESIGNS: - Conservator type - Hermetically sealed

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

TANZANIA BUREAU OF STANDARDS

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

VALIADIS S.A. HELLENIC MOTORS

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

EMPAC Metal enclosed capacitor bank for wind applications

Cast resin transformers

CAST RESIN TRANSFORMERS

OLIVER ONLINE VOLTAGE REGULATION

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

ahead of time Voltage Stabilisers

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

GAS INSULATED VOLTAGE TRANSFORMERS.

CAST RESIN TRANSFORMERS

Technical specification

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

SLIM Transformer. Compact transformer solutions for new applications. Your partner in energy solutions

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

NXPLUS C Single busbar. Maintenance-free for lifetime

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

vertical fuse switch disconnectors

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

825-P Modular Protection System for motors Specification Guide

LV Capacitor Bank APC

MP-100-APS. Flame Spray Technologies SprayTech. Multi-Process Thermal Spray Centre

PRODUCT CATALOGUE 2016

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

High-voltage high-breaking capacity VV fuse-links

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Turbogenerators. Technical Features:

TPD2250H6.3 TECHNICAL DATA

Fuse switch disconnectors

High voltage high-breaking capacity VV fuse-links

Distribution transformers Efficiency over life-cycle

Mobility & emobility

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

The firm is accredited according to the standards of quality management system of ISO-9001:2008 by BM TRADA.

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Benefits, typical uses

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

Liquid cooled heavy duty converter

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

VALVES WITH SA ELECTRIC ACTUATOR

Reliable liquid or simulated winding indication at eye level


E-15 Uninterruptible Power Systems (UPS)

VD4 Installation and service instructions kv A ka

Isolating transformer ES710

METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV

DISTRIBUTION TRANSFORMERS CATALOGUE

33KV INDOOR SWITCHGEAR

White Paper Load Banks for Power System Testing

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Explosion and flame-proof cast iron electric motors

with Vacuum Circuit Breaker HAF

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

SINGLE PHASE TEFC CAGE MOTORS

BC IMPREGO Impregnated dry type transformers and autotransformers

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Transcription:

Cast Resin Transformers

Since their appearance and introduction in the electric market, Cast Resin Transformers (CRT) have won an important position in every sector due to: The use of special epoxy self-extinguishing resins which are Less inorganic content as compared to the oil-based transformers. Highly resistant structure in front of short-circuits and non-higroscopic windings. The simple localization of failures, caused by internal or external factors make them suitable for all kinds of facilities; they are specially recommended for the so-called strategic usages. STANDARD FITTINGS Off-load Jumper switch with ±2 x 2,5% steps, on high voltage (HV) side. Primary terminals for wire connection. Secondary terminals for bar connection. Hoisting eyebolts. Grounding terminals. Bidirectional wheeled-wagon. OPTIONAL FITTINGS Upon client request, CRT can be provided with: Forced air cooling system to increase available nominal power. Terminal box for auxiliary circuits. Protective cabinets to comply with Ingress Protection standards (IP21, IP23 and IP31). Bimetallic terminal adaptors, since main terminals (HV and LV sides) are in aluminium. 7 points Off-load Jumper switch with ±3 x 2,5% steps, other options on request. Electrostatic shields Client requirements not listed above will be evaluated by our R&E Department.

Temperature Monitoring Unit (TMU) fully programmable with alarm, trip and forced ventilation outputs (Figure 1). If necessary, it also handles installation room blowers. The basic provision includes three (3) Pt100 sensors to be installed inside pre-conceived ventilation channels in each LV winding. A fourth Pt100 thermal probe, to monitor room temperature and eventually to drive room blowers, is also available upon request. TMU that handles six (6) Pt100 sensors and TMU that can integrate measurements and signals sending them to a Control/Monitoring PC or a SCADA system. Figure 1 REMARKABLE ADVANTAGES Room temperature: 20º C Compact design, requiring no important surfaces for installation if Very easy to install; they can be directly placed close to the load, without Room temperature: 40º C Figure 2 arrestors and/or space foundations.. cleaning and periodical adjustment of connections. For indoor clean facilities, they can be considered maintenance-free. Important nominal power reserve. The adding of forced ventilation, acting directly on HV and LV windings, allows an increase of up to 25% in the original plate capacity. For other rates, please contact us. Due to their nature, the manufacturing materials are environmentalby internal electrical arcs do not produce toxic gases and just a minimum amount of smoke. Extra capacity during temporary overcharges. Their windings design with low current density and the use of resins with high mechanical resistance and optimun temperature behaviour, allow higher capacity to withstand short-period overcharges. Two important parameters to consider when analysing Overcharges for CRT transformers are room temperature and loading status prior to overcharge. (Figure 2)

S1 H INDOOR INSTALLATION (Figure 3) To be able to use the maximum capacity of the transformer, the installation room must have a fresh air inlet through a lower ventilation window S (m2) and a hot air outlet through a higher ventilation window S1 (m2). S1 must be located on the opposite wall and at a certain height H (m). Being P, transformer total losses (in kw), they should verify: S Figure 3 H(m): Diferencia de altura entre S y S1. If required natural ventilation is not possible, forced ventilation must be - provided. This should be able to remove 4,5 m3/min of air for every kw of transformer total losses. To drive this ventilation system, one option is to use the fourth Pt100 sensor. ELECTRICAL DISTANCES The minimum distances from the windings to the security enclosure should be as follows: ISOLATION TYPE MINIMUM DISTANCE IN mm 2000 kva 13200 ± 2 x 2.5% / 400-231 V/V CLASSIFICATION E2 C2 F1 The European standard, handled by the CENELEC (Comité Européen de Normalisation Electrotechnique), for dry type transformers covers these aspects: Humidity, condensation and pollution Ambient temperature (indoor and outdoor conditions) Emission of toxic fumes in the event of pyrolysis or combustion Flammability or better still self-extinguishing properties when exposed to external flames. E2: Frequent condensation and high pollution or a combination of both. C2: Operation, transport and storage at ambient temperatures down to 25 C; installation outside. F1: special test in accordance with appendix Z.C.3 as per HD 464 S1; materials must be free from halogens; emission of toxic substances and thick smoke must be reduced to a minimum. - 500 kva 33000 ± 2 x 2.5% / 400-231 V/V We reserve the right to modify the values herein this document without prior notice.

Technology and Special Designs Tadeo Czerweny Tesar S.A. produces a wide variety of CRT transformers using high technological and guaranteed quality components to provide an excellent uninterrupted service, and therefore an improved return on investment (ROI). The whole casting process of the windings is performed in modern installations automatically controlled, with hardware and software of latest generation. Raw materials and supplies used to build the electrical windings are premium class and submitted to strict tests during Suppliers selection and their reception at Industrial Plant. High Voltage windings (figure 4) and Low Voltage windings (figure 5) are manufactured using the most advanced Foll Winding Machines. CRT installed in an IP Cabinet Figure 4 CRT with 7 Regulating points on HV side Figure 5 As of june 21st 2010, the whole manufacturing process is certified under ISO 9001. At present, we are backed by the ISO 9001:2015 certification, by DET NORSKE VERITAS V.B. Step-Up CRT (YNd11) with forced air cooling system.

CLASS "F" 15 kv TRANSFORMERS - Ratio: 13,200 (± 2 x 25%) / 400-231 V/V Power Losses (W) Vcc Sizes (mm) / Mass (kg) - IP00 Sizes (mm) / Mass (kg) - Including Cabinet IP Trail (kva) Po Pcc (%) Depth Width Height Mass Depth Width Height Mass (mm) 250 * 880 3.300 6 1350 690 1.300 900 1.750 1.100 1.700 1.150 600 315 * 1.000 4.000 6 1.350 690 1.350 1.050 1.750 1.100 1.700 1.300 600 400 * 1.200 4.800 6 1.400 1.000 1.450 1.200 1.950 1.200 2.050 1.480 800 500 * 1.400 5.900 6 1.400 1.000 1.550 1.400 1.950 1.200 2.050 1.680 800 630 * 1.650 6.800 6 1.500 1.000 1.600 1.700 1.950 1.200 2.050 1.980 800 800 * 2.000 8.000 6 1.550 1.000 1.750 2.000 1.950 1.200 2.050 2.280 800 1.000 * 2.300 9.400 6 1.650 1.000 1.850 2.550 2.250 1.350 2.550 2.930 800 1.250 * 2.800 11.500 6 1.750 1.240 1.900 2.900 2.250 1.350 2.550 3.280 1.000 1.600 * 3.300 13.500 6 1.800 1.240 2.150 3.700 2.250 1.350 2.550 4.080 1.000 2.000 * 4.200 16.000 6 1.950 1.240 2.250 4.500 2.600 1.450 2.750 4.950 1.000 2.500 * 5.000 18.000 6 2.050 1.240 2.300 5.350 2.600 1.450 2.750 5.800 1.000 3.150 5.500 19.500 8 2.300 1.240 2.375 6.800 2.600 1.450 2.750 7.300 1.000 (*) IEC 60726 and IEC 60076 CLASS "F" 36 kv TRANSFORMERS - Ratio: 33,000 (± 2 x 25%) / 400-231 V/V Power Losses (W) Vcc Sizes (mm) / Mass (kg) - IP00 Sizes (mm) / Mass (kg) - Including Cabinet IP Trail (kva) Po cc (%) Depth Width Height Mass Depth Width Height Mass (mm) 315 * 1.300 4.000 6 2.000 1.000 1.800 2.700 2.700 1.700 2.400 3.100 800 400 * 1.700 4.300 6 2.100 1.000 1.800 3.000 2.700 1.700 2.400 3.400 800 500 * 1.900 4.800 6 2.100 1.000 1.900 3.300 2.700 1.700 2.400 3.700 800 630 * 2.200 6.700 6 2.150 1.000 2.000 3.700 2.700 1.700 2.400 4.100 800 800 * 2.700 8.000 6 2.200 1.000 2.100 4.300 3.000 1.900 2.950 4.800 1.000 1.000 * 3.350 9.400 7 2.300 1.200 2.300 4.600 3.000 1.900 2.950 5.100 1.000 1.250 * 3.800 12.700 8 2.400 1.200 2.300 5.000 3.000 1.900 2.950 5.500 1.000 1.600 * 4.000 13.500 8 2.400 1.200 2.500 5.900 3.000 1.900 2.950 6.400 1.000 2.000 * 4.700 17.400 8 2.500 1.200 2.700 7.000 3.500 2.100 3.450 7.600 1.000 2.500 * 5.500 21.000 8 2.600 1.200 2.850 8.000 3.500 2.100 3.450 8.600 1.000 3.150 7.500 23.000 8 2.900 1.300 3.000 10.000 3.500 2.100 3.450 10.600 1.000 * For thermal classes other than F, please contact us. * For other ratios and specifications, please contact us. * Cabinet are only provided on request. * Other Trail sizes, upon request. (*) IEC 60726 and IEC 60076 FTT0005 Rev. 2 SERVICE Phone call or e-mail to + 54-3404 - 487200 - Int. 113 servicios1@tadeoytesar.com.ar Administration, Industrial Plant and Sales: República 328 (S2252BQQ), Gálvez, Santa Fe, Argentina / Phone: + 54-3404 - 487200 E-mail: administracion@tadeocytesar.com.ar / ventas@tadeoytesar.com.ar Buenos Aires Commercial Office: Bernardo de Irigoyen 330 5º piso of. 121 (C1072AAH) C.A.B.A., Argentina / Phone: + 54-11 - 5272 8001 to 5 E-mail: tczbsas@tadeoytesar.com.ar www.tadeoczerwenytesar.com.ar