USER S MANUAL. TwinFresh R-50 SINGLE-ROOM REVERSIBLE VENTILATOR

Similar documents
AXIAL FANS Axis / Tubo OPERATION MANUAL

SINGLE-ROOM ENERGY RECOVERY VENTILATION UNIT

USER S MANUAL VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ VKF/ VKOM / OVP

MANUAL RECESSED AIR CURTAINS

Mod: KLD6-12/35XLAS-N

Multi-Mover Charger for model L25

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

Source Capture Air Purification System

Operating Instructions. International English. CCS Dust Extractor

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Switching DC Power Supply

WELDING FUME EXHAUSTERS & ARMS

HD18F2M1.

82V LITHIUM-ION BATTERY CHARGER GC 400

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

DC Master 24/ A

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

NCSA 20plus Service Manual

DC POWER SUPPLY ALIMENTATION C.C.

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

EGQ 212: Duct transducer, CO 2 and temperature

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

Operating Instructions

Safety drying ovens. Advantages: Areas of application: FDL series 115

TPHK Series Immersible Pump

AEROSTAT HP-N-Ex Ionising Air Blower

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Industrial flue gas probes. Instruction manual

SSP-Series Portable Balances Operation Manual

MPA Chassis for Multi-Probe Magnetic Transducers

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

TPAK Series COOLANT PUMP

Illumifalls Patio Pond

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

Safety drying ovens with expanded temperature range

High Pressure Abrasive Blast Cabinet 42000

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Safety drying oven with expended temperature range

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

GL1200T Cut & Seal. (GL1200 Seal only)

Operating Instruction for Downlights

Electric expansion valve Type ETS ETS 400

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Wireless Dimmer Installation and User Guide

Heating chamber with mechanical convection

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Operating instructions

Heating chamber with mechanical convection

ATM Lighting sp. z o.o

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Contents. Mounting instructions. 3 Hangers placement...4 Mains connection instructions..5 Safety zones.. 6 Maintenance...7 Warranty card.

Oil-free piston compressors KK and piston vacuum pumps KV

Users Manual Direct Drive Roof Fans

EASY CHARGE Weather-resistant fixed mount Battery Charger

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

INSTALLATION RULES for SCS/SENSOR Pt100

HOYMILES MICRO-IVERTER MI-250

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

INSTALLATION GUIDE AND USER MANUAL

DSP led gaming monitor USER MANUAL

Energy-saving motors (ESM)

INSTALLATION MANUAL. PrimeFire#2 PF x 1 x 1 x 1. Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

Heavy Duty Series (HDS) Installation and user guide

OPERATING INSTRUCTIONS

800W Generator. Original manual AFTER SALES SUPPORT MODEL: WGG-800, 07/2012, 7597

TUNGUS. POWDER FIRE-EXTINGUISHING MODULE MPP(N)-5-I-GE-U2 Passport and Manual instructions

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

TUNGUS. ANNEX А (obligatory) THE RESULTS OF TECHNICAL MAINTENANCE Table А.1 - Information about reloading, reexamination. Executive (company, name)

HEINE NT4 MED V

RVP-R- VAV controller. In explosion-proof version

SMART Application Structure Acoustics s n fa f o o R

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

MANUAL. Single charger

Heavy Duty Series (HDS) Installation and user guide

BR133AE BR135AE. Random orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

Safety Shock Absorbers SCS33 to SCS64

6. Electrical. 7. Settings. 8. Quick

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

Technical Documentation

Operating instructions in the back. PD1420LP

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

SSPF SO73-SO84A SSCA. Electric orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES

Transcription:

USER S MANUAL SINGLE-ROOM REVERSIBLE VENTILATOR

2 CONTENT Introduction Use Delivery set Designation key Main technical parameters Safety requirements Design and operating logic Mounting and set-up Unit connection and control Maintenance Storage and transportation rules Manufacturer s warranty Acceptance certificate Connection certificate Warranty card 2 4 7 22 22 22 2 2 2

INTRODUCTION This user s manual includes technical description, operation, installation and mounting guidelines, technical data for the singleroom reversible ventilator, hereinafter referred as the unit. USE The unit is designed to arrange permanent controllable air exchange in flats, cottages, hotels, cafes and other domestic and public premises. The unit is equipped with a ceramic heat exchanger that enables supply of fresh air due to extract air heat energy utilization. The unit heat exchange efficiency reaches 9%. The unit is designed for through-the-wall mounting. The unit it suitable for installation in the walls from 20 (4 /4 ) up to 60 (4 /6 ), depending on the unit configuration. The unit is rated for continuous operation. Transported medium must not contain any flaable or explosive mixtures, evaporation of chemicals, coarse dust, soot and oil particles, sticky substances, fibrous materials, pathogens or any other harmful substances. The unit is designed operation at the ambient temperature ranging from -20 C (-4 F) up to +0 C (+22 F). The unit delivery set depending on the model is shown in tables -. Table DELIVERY SET Delivery TwinFresh R-0 TwinFresh R-0 -M TwinFresh R-0 -М TwinFresh R-0 -М -L TwinFresh R-0 -L TwinFresh R-0 -L - TwinFresh R-0 - TwinFresh R-0 - -М TwinFresh R-0 -М -L -L TwinFresh R-0 -L unit + + + + + + + + + + + + + + + + + Power cable, m Unitronic LIYY UL CSA xawg/7 + + + + + + + + + + + + + + + + + (x0.2) Control and power unit + + + + + + + + + + + User's manual + + + + + + + + + + + + + + + + + Packing box + + + + + + + + + + + + + + + + + Fasteners + + + + + + + + + + + + + + + + +

4 Table 2 Delivery TwinFresh R-0-L -2 TwinFresh R-0-2 TwinFresh R-0-2 20V/60Hz) - TwinFresh R-0 - TwinFresh R-0 - -М TwinFresh R-0-М TwinFresh R-0 -М -L TwinFresh R-0 -L TwinFresh R-0 -L -4 TwinFresh R-0-4 unit + + + + + + + + + + + + + + + Power cable, m Unitronic LIYY UL CSA xawg/7 + + + + + + + + + + + + + + + (x0.2) Control and power unit + + + + + + + + + + + User's manual + + + + + + + + + + + + + + + Packing box + + + + + + + + + + + + + + + Fasteners + + + + + + + + + + + + + + + Mounting plate + + + Table Комплектность TwinFresh R-0-4 -4М TwinFresh R-0-4М TwinFresh R-0-4М -4L TwinFresh R-0-4L TwinFresh R-0-4L - TwinFresh R-0- TwinFresh R-0 - -М TwinFresh R-0-М TwinFresh R-0-М -L TwinFresh R-0-L TwinFresh R-0-L unit + + + + + + + + + + + + + + + + Power cable, m Unitronic LIYY UL CSA xawg/7 + + + + + + + + + + + + + + + + (x0.2) Control and power unit + + + + + + + + + + + User's manual + + + + + + + + + + + + + + + + Packing box + + + + + + + + + + + + + + + + Fasteners + + + + + + + + + + + + + + + +

UNIT DESIGNATION KEY TwinFresh RX-0-XX (XXX/XX) Air capacity [m/h] Control unit _ - no control unit included; - control unit included. Round connecting air duct Unit designation TwinFresh single-room reversible ventilator Power main parameters other than 20 V / 0 Hz Connecting air duct (telescope) air duct length _ - 20-470 (9 /6-8 /2 ); M - 470-720 (8 /2-28 /8 ); L - 720-60 (28 /8-4 /6 ). Outer grille (outer hood) type _ - metal outer hood; - round stainless steel outer hood; 2 - metal tapered outer hood for 20-470 (4 /4-8 /2 ) air duct; - plastic round grille; 4 - plastic rectangular grille; - ductwork system 204x60 (8 /6-2 /8 ) with an end plastic grille. TECHNICAL PARAMETERS The main unit overall and connecting dimensions, outer view and technical parameters are shown in fig. -6 and in tables 4-0. Table 4 Mode Voltage Power [W] Air capacity [m /h] (CFM) RPM [min - ] Noise level, m [db(a)] (Sones) 20 V / 0 Hz,4 2(4,7) 70 22(0,) 2 (20V / 60 Hz),0 0(29,4) 00 29(0,8) IP 24

6 6 (6 /8") 274 (0 /6") B 24 мм (0") 22 (8 /8") 6 (6 /8") 22 мм (8 /8") Fig.. overall and connecting dimensions Table Unit modifications inch inch B TwinFresh R-0 TwinFresh R-0 20 9 /6 470 8 /2 -М TwinFresh R-0-М TwinFresh R-0-М 470 8 /2 720 28 /8 -L TwinFresh R-0-L TwinFresh R-0-L 720 28 /8 60 4 /6

7 6 (6 /8") B 9 (7 /6") 22 (8 /8") 6 (6 /8") 22 (8 /8") Fig. 2. - overall and connecting dimensions Table 6 Unit modifications inch inch B - TwinFresh R-0- TwinFresh R-0-20 9 /6 470 8 /2 -М TwinFresh R-0-М TwinFresh R-0-М 470 8 /2 720 28 /8 -L TwinFresh R-0-L TwinFresh R-0-L 720 28 /8 60 4 /6

8 6 (6 /8") B 8 (7 /6") 22 (8 /8") 6 (6 /8") 22 (8 /8") Fig.. - overall and connecting dimensions Table 7 Unit modifications inch inch B - TwinFresh R-0- TwinFresh R-0-20 9 /6 470 8 /2 -М TwinFresh R-0-М TwinFresh R-0-М 470 8 /2 720 28 /8 -L TwinFresh R-0-L TwinFresh R-0-L 720 28 /8 60 4 /6

9 6 (6 /8") 60 (2 /8 ) B 6 (6 /8") 00 (9 /6 ) 00 (9 /6 ) 22 (9 /8") 22 (8 /8") 9 ( /6") 204 (8 /6") 22 (8 /8") Fig. 4. - overall and connecting dimensions Table 8 Unit modifications inch inch B - TwinFresh R-0- TwinFresh R-0-20 9 /6 470 8 /2 -М TwinFresh R-0-М TwinFresh R-0-М 470 8 /2 720 28 /8 -L TwinFresh R-0-L TwinFresh R-0-L 720 28 /8 60 4 /6

0 22 (8 /8") 6 (6 /8") 6 (6 /8") 20 (9 /6") B 80 мм (7 /6") 22 (8 /8") Fig.. -4 overall and connecting dimensions Table 9 Unit modifications inch inch B -4 TwinFresh R-0-4 TwinFresh R-0-4 20 9 /6 470 8 /2-4М TwinFresh R-0-4М TwinFresh R-0-4М 470 8 /2 720 28 /8-4L TwinFresh R-0-4L TwinFresh R-0-4L 720 28 /8 60 4 /6

224 (8 /6 ) B 6 (4 /6 ) Fig. 6. -2 overall and connecting dimensions Table 0 Unit modifications inch inch B -2 TwinFresh R-0-2 TwinFresh R-0-2 20 4 4/4 470 8 /2 SAFETY REQUIREMENTS WARNING! DISCONNECT THE UNIT FROM POWER SUPPLY BEFOE MOUNTING AND REPAIR OPERATIONS. MAKE SURE THE IMPELLER DOES NOT MOVE. Before connecting the unit to power mains make sure that the casing is free of any visible damages and foreign objects inside that can damage the impeller blades. Otherwise please contact the seller. WARNING! THE UNIT IS NOT RATED FOR OPERATION IN EXPLOSIVE OR FIRE-HAZARDOUS MEDIA. MAKE MEASURES TO PREVENT POSSIBLE GAS BACK DRAFTING FROM GAS OR OPEN FLAME DEVICES. WARNING: THE UNIT MAY HAVE SHARP EDGES AND ANGLES. TAKE STEPS TO PREVENT PHYSICAL INJURIES DURING MAINTENANCE AND REPAIR OPERATIONS.

2 DESIGN AND OPERATING LOGIC 2 4 6 6 - ventilation unit with a decorative grille - item 2 - inner telescopic air duct - item - outer telescopic air duct - item 4 - outer hood (cover, back wall with a pipe) or an outer plastic grille, depending on the unit modifications - item - ceramic heat exchanger - item 6 - Filter - 2 items Fig. 7. Unit design The unit consists of a plastic telescopic air duct (2) and (), a ventilation unit with a decorative grille () and an outer hood (4), refer fig. 7. A plastic ventilation grille may be used instead of a metal outer hood, depending on the unit modification. The total telescopic air duct length is regulated due to position of the inner telescopic duct (2) inside the outer telescopic duct (). Two filters 7 and a ceramic heat exchanger () are installed in the inner telescopic air duct. The inner filter is designed for supply air cleaning and prevention of dust and foreign objects ingress inside the heat exchanger and the impeller. The heat exchanged is used to warm up supply air flow by extract air heat energy and provide supply of warmed-up and filtered air to the room. The heat exchanger has a pull cord inside to facilitate its maintenance. The ventilation unit with a decorative grille () and automatic shutters are to be installed on inner room side on the ventilator casing. The outer hood (4) or the plastic ventilation grille (depending on the unit modification) is to be installed on the outer building side to prevent ingress of water and solid foreign objects.

4 8 2 7 6 7 Ventilation unit with a decorative grille ( item); 2 Inner telescopic duct ( item); Outer telescopic duct ( item); 4 Plastic grille ( item); Rectangular plastic air duct ( item); 6 Ceramic heat exchanger ( item); 7 Filter (2 items); 8 Plastic connecting bend ( item). Fig. 8. Unit design The - unit consists of the plastic telescopic air duct 2 and, the ventilation unit with a decorative grille (), the plastic connecting bend (8), the rectangular plastic air duct () and an outer plastic grille (4), fig. 8. The - unit is a telescopic unit with an adjustable length that is regulated due to position of the inner telescopic duct (2) inside the outer telescopic duct (). Two filters (7) and the ceramic heat exchanger (6) are installed in the telescopic duct, inside the inner part. The heat exchanged provides warming up of supply air flow with extract air heat energy. The filters are installed on both sides of the heat exchanger, fig. 8 and serve to purify supply air and prevent ingress of foreign objects inside the heat exchanger. The ventilation unit with a decorative grille () and automatic shutters is installed on the unit casing inside the room. Due to the plastic connecting bend (8) and the flat plastic air duct () the unit - is suitable for angular mounting. The plastic ventilation grille (4) is installed from outside to prevent direct ingress of water and large objects to the unit.

4 MOUNTING AND SET-UP The unit is designed for installation into a specially designed through hole inside a wall. The hole must be perpendicular to the wall plane. The mounting guidelines are shown in fig. 9. Fill the gaps with a mounting foam OUTSIDE INSIDE Fig. 9. Unit mounting Install the telescopic duct in the hole from outside and fill the gaps between the duct and the wall with a mounting foam. For easy mounting keep the clearances between the duct and the wall within -0 (/6»-/8»). Fix the outer hood according to the wall holes with four 4x screws and the dowels 6x included into delivery set, fig. 0. Fix the ventilation unit to the wall with the screws x2 included into delivery set and the dowels x2, fig.. The mounting sequence for other unit modifications is the same, fig. -2. 200 00 4 holes 00 200 Fig. 0. Hole spacing for the outer hood fastening for.

Hole spacing for fastening of the ventilation unit for all unit modifications. Hole spacing for fastening of the external grille for - 4 holes 2 holes Hole spacing for fastening of the external grille for -4 Hole spacing for fastening of the outer hood for -2 with the mounting plate, refer table 2. 4 holes 270 (0 / ) 4 holes 8 (7 7/2 ) Hole spacing for fastening of the outer hood for - Hole spacing for fastening of the outer hood for - 4 holes 2 holes Fig.. Hole spacing for the unit mounting

6 fill the gaps with a mounting foam Fig. 2. Mounting of the single-room reversible ventilator - The control and the transformer unit must be installed in a specially designed and prepared hole in a wall as shown in fig., in inaccessible for children places. While installation consider the length of the cable supplied with the unit. A longer cable may be used. The recoended cable type and mark are shown in fig. -. KVR 2 holes KVR-T - 70 (2 /4 ) 70 (2 /4 ) R (R /8 ) 2 holes - Fig.. Hole spacing for mounting of the control unit and transformer unit.

7 CONNECTION AND CONTROL The external control unit KVR is used for controlling of the unit. It is available upon order if not included into delivery set of the unit modification. The control and power unit enables controlling set operation modes and consists of the control unit and transformer unit, fig. 4. The unit is rated for connection to single-phase 20 V / 0 Hz or 20 V / 60 Hz depending on a transformer type. Separate power supply must be provided both to the control and power unit and to the ventilator. The control and transformer unit may be replaced with a control and power unit with the interconnected controller and the transformer installed in a coon junction box. The control and power unit modification type is selected depending on the power mains voltage and power transformer in accordance with the table. Control and power unit Transformer unit KVR control unit KVR-T control and power unit Fig. 4. KVR and KVR-T control unit (overall view)

8 Table Табл. Control and power unit name Transformer parameters Voltage [V] Power [W] Input Output Note KVR-T-6 KVR-T-6 (20 V/60 Hz) 6 20/0 Hz 20/60 Hz 2 Connection up to 2 units KVR-T-2 KVR-T-2 (20 V/60 Hz) 2 20/0 Hz 20/60 Hz 2 Connection up to 4 units The control unit is a three-key switch with an integrated printed circuit board for installation into a standard junction box. All electric connection to the control unit and the ventilator are performed with the socket connectors for mounting and servicing facilitation. Each mating part of the connector has a colour marking in compliance with marking on the circuit board to ensure correct and quick electric installation. The KVR control unit is used to set one of four operation modes of the unit, fig. :. Ventilation mode (air extract / air supply)* at first speed with air capacity 2 m /h (4.7 CFM). 2. Ventilation mode (air extract / air supply)* at second speed with air capacity 0 m /h (29.4 CFM).. Reverse (heat recovery) operation at first speed with air capacity 2 m /h (4.7 CFM). The ventilator changes operation mode (air extract / air supply) every 70 seconds. 4. Reverse (heat recovery) operation at second speed with air capacity 0 m /h (29.4 CFM). The ventilator changes operation mode (air extract / air supply) every 70 seconds. * - air flow direction depends on position of the jumper JMP on the circuit board. The jumper is set to provide supply mode by default, fig. 6. Extract/supply mode* Second speed mode Unit on Reverse operation First speed mode Unit off Fig.. Operation mode control unit

9 Controller KVR JMP 7 8 40 9 Marking "-" on the controller socket connector 2 ~20 V or ~20 V Marking "-" on the controller socket connector 6 4 2 4 4 2 Twin Fresh R-0 6 ~20 V or ~20 V 2 4 4 2 2 22 2 24 2 2 2 4 4 2 4 ÕÒ 4 Marking "2-2" on the controller socket connector 2 L N Marking "-" on the connecting cable socket connector Marking "-" on the connecting cable socket connector ~20 V or ~20 V Fig. 6. Total wiring diagram for connection to KVR controller General wiring diagram for the unit connection to KVR controller is shown in fig. 6. The unit is connected to the KVR controller with two channels. Such connection solution provides flexible operation mode for several interconnected units. The units connected to the channel A operate in supply mode and the units connected to the channel B operate in exhaust mode. This operation logic is provided by the jumper on the circuit board of the units in Flow in position. In ventilation mode all the connected units operate in air extract mode (the JMP jumper on the circuit board is in Flow out position) or in supply mode (the JMP jumper on the circuit board is in Flow in position). The electric connection is performed with a five-wire cable. The wires are marked in compliance with the delivered cable for easy installation. The minimum conductor cross section is 0.2 2 (2 AWG). Type and power of the step-down transformer T is selected on the assumption that the alternating current 2 V and power consumption W is required for correct operation of one unit. Power supply 20 V / 0 Hz or 20 V / 60 Hz must be provided both to KVR (KVR-T) control unit and to the fan (socket connectors -2 in each case).

20 Channel B:. Channel B:N. KVR controller ~20 V or ~20 V ~20 V or ~20 V ~20 V or ~20 V T (2 W) Channel A:. Channel A:N. ~20 V or ~20 V Fig. 7. General wiring diagram for connection of up to 4 units to KVR controller To connect from 2 to 4 units, follow the wiring diagram in fig. 7. This wiring example shows connection through 2 W power transformer or 2 W control and power unit. Power supply 20 V / 0 Hz or 20 V / 60 Hz must be provided both to KVR (KVR-T) control unit and to each fan (socket connectors -2 for each case). The inputs at the controller socket connectors are marked 2 to 2. The outputs at the controller socket connectors are marked to. The socket connectors on the delivered connecting cable are marked to and are designed for connection to the controller socket connectors, - for outputs and 2-2 for inputs. ~20 V or ~20 V ~20 V or ~20 V

2 A-no.2 Fan no. 2 Wall A (no.) Jumper JMP ХТ 40 9 8 7 2 4 2 6 4 ХТ 2 4 ХТ 2 4 40 9 8 ХТ 6 4 7 A-no. Cable K S KVR control unit (mounting view) Cable K2 Т 2 4 2 4 2 4 ХТ4 ХТ Р4 Cable K Connecting cable socket connector ХТ ХТ2 2 4 6 Р Р2 Р 6 2 4 2 4 ХТ4 ХТ2 T transformer unit X 2 V N L Power cable with a plug L N 2 22 2 24 2 ХТ4 ХТ2 to the next unit Кабель К Jumper JMP T transformer unit Connecting cable socket connector 2 Fan no. Controller circuit board Т Connecting cable socket connector ХТ 2 4 2 22 2 24 2 Кабель К2 ХТ 2 2 Cable K controller circuit board 2 L N to KVR control unit Connecting cable socket connector Fig. 8. Wiring diagram for connection of up to 2 units to KVR controller One KVR control unit powered by 40 W transformer is capable to control up to 2 connected TwinFresh RA-0 units (fig. 8). Connection sequence: Connect the 2 V transformer leads to the terminals A:, 6 of A (KVR) controller by means of the socket connector on the cable K2. K2 cable is supplied with 40 W transformer unit. Then connect the first fan A-no. to A:... terminals of KVR controller through the delivered connecting cable supplied with the first fan. Connect the second fan A-no.2 (terminals A2: 2 2) to the first fan (terminals A2: ) through the connecting cable supplied with the second fan. Connect the other fans (up to 2 items) in the same way. Provide 20 V or 20 V power supply to the terminals A2:, 2 of each fan. The rotation direction of the fans is determined by JMP jumper position on the A2 fan circuit board: the utmost left position sets the fans into exhaust mode (Flow Out), the utmost right position sets the fan into supply mode (Flow In). The jumper position sets rotation direction for each of the fan in the group. Power is supplied to the transformer unit through the power cable with a plug, which is pre-wired to the transformed terminal block by the manufacturer.

22 MAINTENANCE Disconnect the ventilator from power supply before any maintenance operation with the unit. Maintenance of the unit means regular cleaning of the unit surfaces from dust and cleaning or replacement of the unit filters. Removing of the heat exchanger and the filter: first take off the front panel, unscrew the fasteners, disconnect and remove the fan and the distance ring. The heat exchanger is equipped with a special cord to facilitate its withdrawal together with the filters, fig. 9. Clean the unit from dust with a soft brush, cloth or compressed air. Do not use water, abrasive detergents, solvents, sharp objects. The impeller blades must be cleaned once in year. Clean the filters as often as these gets soiled, but at least once in -6 months. Cleaning with a vacuum cleaner is allowed. The filters must be replaced after two consecutive cleaning (-2 times in year). For the new filters, contact the seller. Cord Heat exchanger Filters Fig. 9. Unit maintenance STORAGE AND TRANSPORTATION RULES Store the unit in the manufacturer s original packing box in a dry ventilated premise at the temperatures from +0 C (4 F) up to + 40 C (04 F). Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation and sealing deformation. Use hoist machinery for handling and storage operations to prevent the unit damage in consequence of falling or excessive oscillation. Fulfil the handling requirements applicable for the applicable freight type. Transportation with any vehicle type is allowed provided that the unit is protected against mechanical and weather damage. Avoid any mechanical shocks and strokes during handling operations. MANUFACTURER S WARRANTY Manufacturer hereby guarantees normal performance of the unit during two years from the date of retail sale provided compliance with transport, storage, mounting and operation regulations. In case of no confirmation of sales date the warranty period is calculated from the production date. In case of failures in the unit operation during the warranty period the manufacturer will accept claims and complaints from a customer only after receiving a technical protocol with a fault description. The unit damage as a result of unauthorized modifications in the electric circuit diagram is not a warranty case. For warranty and post-warranty services contact the product manufacturer or the Seller. In case of warranty claim please submit the present user s manual with a stamp of the trade company, filled connection certificate and the warranty card. Both warranty and postwarranty services are carried out at the manufacturing facility. In case of warranty claim please provide the filled guarantee card with the trade company stamp and the user manual. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY DAMAGES RESULTING FROM THE UNIT MISUSE OR GROSS MECHANICAL INTERFERENCE. FOLLOW THE USER S MANUAL REQUIREMENTS TO ENSURE NON-STOP AND TROUBLE-FREE OPERATION OF THE UNIT.

2 ACCEPTANCE CERTIFICATE The single-room reversible ventilator has been duly certified as serviceable. We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council Directive 2004/08/ EC, 89/6/EEC and Low Voltage Directive 2006/9/EC, 7/2/EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Stamp of the acceptance inspector Date of production Sold by Name of the trade company, stamp of the shop Date of sale CONNECTION CERTIFICATE The single-room reversible ventilator has been connected to power mains pursuant to the guidelines of the user s operation manual by the electrician: Company name Electrician s name Date Signature WARRANTY CARD

20 V62(R-0)EN-0