OPERATING INSTRUCTIONS

Similar documents
Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

EPS/ELA-Series User Manual EPS/ELA 250W

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

User Manual Rittal PMC UPS 6kVA

Wireless doorbell transmitter FS20 TK

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Operating Instructions for PAC800 Battery Charger

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

DC REGULATED POWER SUPPLY

DC POWER SUPPLY ALIMENTATION C.C.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

BATTERY CHARGER CHR-1445

Triple Output Power Supply

PURE SINE WAVE DC TO AC POWER INVERTER

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

CLEAN POWER TM CPS Series Operator s Manual

DC REGULATED POWER SUPPLY

Battery Charger Series EASY Charger

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

EVS RP6020. Instruction Manual

Battery Charger. Series EASY Charger. User s manual

Switching DC Power Supply

Table of Contents 文管中心 發行章

OPERATING INSTRUCTIONS

Functions and Displays

General safety and installation information.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

GSL Electronics Modified Sine Wave Power Inverters

Usage Instructions of Solar Control for 3Way-Ball Valve

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Operating manual UPS - System

600 Amp Battery Jumper with Air Compressor

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

PRODUCT MANUAL TILE CUTTING MACHINE. . Operation. Parts List and Diagram SPECIFICATIONS CAUTION:

RP Instruction Manual

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Multi-Mover Charger for model L25

Installation and Connection: Installation and Operating Manual

MODEL ELC-12/60-D BATTERY CHARGER

Sentry Battery Charger. Installation and Operations Manual Section 75

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Operating Instructions For The X-Seal Manual Thermal Sealer

DC to AC Power Inverters

S150,S300 Series Pure Sine Wave Inverter User s Manual

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

DC to AC Power Inverters

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Operating instructions Bedienungsanleitung Mode d emploi

INSTALLATION INSTRUCTIONS. Mirror-ball 30 cm. For your own safety, please read this user manual carefully before you initial start-up.

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

User Manual WT Combi-S Pure Sinus Wave Inverter

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Go Power! Manual. GP-Smart Charger

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Operating instructions EWB 200

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Power Supply. Model PS-200

Triple Output High Resolution Power Supply. User Manual

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

LEAD ACID BATTERY CHARGER

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

LESTRONIC II BATTERY CHARGER MODEL 19740

Model: SE-4020-CA Automatic Battery Charger

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SAVE THESE INSTRUCTIONS

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

WARNINGS, CAUTIONS AND NOTES

PANcharge1k Battery Charger User's Manual

Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR

PI1500X Power Inverter User s Manual

Pure Sine Wave Inverter 600W-24V User Manual

3000 Series Operation Manual

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

EASY CHARGE Weather-resistant fixed mount Battery Charger

MIL-24/2600Q MIL-24/3200DQ

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Model 1672, 1673 Triple Output Power Supply

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

DATA SHEET FUSIBLE ALLOY THERMAL SENSITIVE PELLET TYPE, 2 AMPERES RATED CURRENT

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Table of Contents Title Page No.

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

Transcription:

100% recy-cling paper Bleached without chlorine GB Imprint These operating instructions are published by Conrad Electronic GmbH, Klaus- Conrad-Str 1, 92240 Hirschau/Germany No reproduction (including translation) is permitted in whole or part eg Photocopy, microfilming or storage in electronic data processing equipment, without the express written consent of the publisher The operating instructions reflect the current technical specifications at time of print We reserve the right to change the technical or physical specifications C Copyright 1997 by Conrad Electronic GmbH Printed in Germany OPERATING INSTRUCTIONS

Power Supply PS 302A Item No : 51 1412 If this current is exceeded the power supply is overloaded It is not allowed to operate the power supply in damp environments or outdoors (according to the safety regulations) Contents 1 Introduction 2 2 Safety Rules (Mains connection and exchange of fuses) 3 3 Operational Elements 6 4 Operation 6 5 Technical Data 8 Power Supply PS 302A Attention! Read before operation! Read the manual carefully and completely In the case of damage caused by non-observance of the instruction, the claims under guarantee lapse We cannot take any liability for consequential damage Please read and understand the instructions before attempting to use the power supply Warning! Operation as directed means: This product is only constructed for connection to an operating voltage between 0 and 30 VDC at the output terminals The power consumption of the connected device must not exceed 2A 1 Introduction This power supply is infinitely variable for voltage and current and can be universally used for school, work and hobby etc 2

11

An electronic current limiter protects the power supply against overload or a short circuit at the output; a thermo fuse interrupts the load circuit (output) when the max temperature is exceeded (>+120 C), in this case the LED for TEMP is on After cooling off again the LED goes off, the output is restored in circuit again If there is an overload (short circuit or overload) the output is turned off, that means the current at the output is more than the preset current limit The output voltage remaining at the terminals is only a few mv When the short circuit is removed the output is restored The red LED displays the limiting condition (U or I) The preset values can be read in a common analog meter using Volt / Ampere toggle switch Voltage and current is set over 3 setting knobs So an exact setting of the output voltage and output current (current limiting) is possible 2 Safety Rules 21 The power supply is constructed in protection class I according to VDE 0411 or VDE 0550 it is equipped with a VDE approved mains cable with a protective conductor and may only be connected to 230 V AC electric mains with protective grounding 22 Please pay attention that the protective conductor (yellow/green) is connected in the unit and in the mains, as there is danger to life if the protective conductor is disconnected Furthermore pay attention that the insulation is neither damaged not destroyed 23 Keep power supplies away from children! 24 Pay attention to the rules for prevention of accidents in industrial enterprises prescribed by the Industrial Trade Associations for electrical installations and production facilities 10 25 When using the power supply in schools and hobby-workshops the usage has to be controlled by the responsible teachers or skilled personell 3

26 If covers are opened or parts are removed, except what is possible without tools, voltage-carrying components can be exposed Terminals can also carry voltage If it is necessary to open the unit before adjustment, maintenance, repairing or exchange of parts or modules, the power supply has to be disconnected from all voltage sources Repairing or maintenance of the power supply may only be executed by skilled personell who know the dangers and the respective rules (VDE-0100 and VDE-0701) 27 Condensers in the unit can still carry voltage, even if the unit has been disconnected from all voltage sources 28 Please make sure to use only new fuse of the proper rating Do not use repaired fuses and do not bridge the fuse holders Pull the plug to change the fuses and separate the soldering station from the mains voltage, as otherwise it will be dangerous to life Turn the fuse holder cap to the left with a screwdriver and lift it with the defect fuse from the fuse holder Replace the fuse only with a new one of the same type After the fuse has been changed, carefully screw the fuse holder cap with the new fuse into the fuse holder 7 8 5a 5 6 2 2 2 4a 4c 4b 1 Attention! Put the power supply only into operation after the cabinet has been safely closed and screwed together 29 Don t switch on the power supply immediately after bringing it in from a cold to warm room Condensed water might impair or destroy your unit Give the power supply time to warm up to room temperature ithout switching it on 210 When working with power supplies it is not safe to carry metal, conductive jewelry necklaces, bracelets, rings etc 211 It is not allowed to connect power supplies with people and animals 212 If the output of one or more power supplies is connected in series 11 3 9 10 4 9

5 Technical Data Mains input : 230VAC + 6%, - 10% Frequency : Power consumption : Output Voltage : Output current : 50 Hz Max 100VA Line Regulation Constant Voltage at Mains Change +6% to 10% : 005 % Load Regulation for 100% Load Change : < 10 mv Ripple at Rated Load : 5 mveff 0 30 V DC, stepless 0,01 2 A max stepless Fuse : Slow Blow 1A / 250V (usually T 1A/250V) Voltage & Current Display : Analog Panel meter common for voltage and current Selectable by toggle switch Weight : approx 43 Kg Dimensions (W x H x D) : 225 x 135 x 260 mm Surrounding Temperature: Operating Temperature (min to max) : +5 C - +40 C Rel Humidity : Max 85%, not condensing Barometric pressure : 600 to 100 hpa 8 voltages (>35 VDC), hazardous to life are created 213 When operating the power supply pay attention to sufficient ventilation Never cover the ventilating slots Place the unit on a hard, flame resistant base Make sure good ventilation of the unit is possible Cooling of the units is mainly achieved by convection (heat flow) 214 Do not operate charging units and connected loads without supervision Take measures to protect and secure the connected products against operational effects of the power supply eg overvoltage (failure of the power supply) and against effects and dangers orginating from themselves ( undue high power input) 215 In the case of error function power supplies can release voltages more than 50 V DC, this is dangerous even if the output voltage of the units is below this value 216 For work under voltage only approved tools may be used 217 To avoid an electrical shock, don t touch directly the output of the power supplies (output sockets/clamps) The leads used must be sufficiently insulated and have sufficient voltage stability and the contacts have to be shockproof (safety sockets) 218 Do not lay metallic bare cables and contacts All these spots have to be covered with suitable, flameresistant insulation material or other measures to protect them against direct contact Protect all electric conductors of the connected consumers against direct contact 219 If there are doubts whether a safe usage is still possible the power supply unit has to be put out of operation and be secured against unintentional use It must be assumed that a safe usage is still possible if the power supply shows visible damage the unit does not work and after longterm storage under unfavourable conditions after transport strain 5

3 Operational Elements See Page No 9 for figure 1 Front Panel 2 Connection clamps (red = +, blue = -) and grounding (yellow/green) 3 Power switch ON/OFF on the rear panel of the unit 4 Controll-LED s for voltage- 4a current-limitation 4b and over-heating 4c 5 Control knob to adjust fine voltage 5a Control knob for coarse voltage adjustment 6 Control knob to adjust current limitation 7 Analog display for DC voltage and current 8 Volt/Amper meter selection toggle switch 9 Fuse holder on the rear panel of the unit 10 Mains connection for a appliance plug (not contained in delivery) 11 Heatsink Attention! During long time operation with a nominal load (30 V / 2 A) or if there are short circuits The heatsinks are getting hot Attention! Danger of burning! Always pay attention to sufficient ventilation of the power supply and never cover the ventilating slots on the top and the bottom of the cabinet to avoid damage As soon as the LED indicates thermal overload, separate the connected user/s from the power supply As soon as the LED is off, the power supply can be used again (after cooling off) If you connect a consumer always pay attention that it is not switched on If you connect a user which is switched on to the output clamps of the power supply, sparks might be produced which might damage the connection sockets and/or the connected leads and/or the clamps b) Adjustment of voltage (unloaded output) First turn the panel control knob for the current limitation (6) to the right (clockwise) until the LED for the current limitation (4b) is off At the same moment the LED for voltage adjustment goes on (4a) Now you can select the desired output voltage The output of the power supply is potential free, that means not connected with the earthing conductor A potential connection between the power supply and the consumer (load) is possible via a separate earthing socket between the output sockets (,,+ and,,- ) 4 Operation a) Connection Connect the earthing contact plug of the power supply with a earthing contact outlet First make shure nothing is connected to the output terminals, then switch on the power supply with the power switch c) Adjustment of the current limitation Switch the power supply off and short the output terminals Switch on the power supply The display for the output current shows, depending on the setting of the control knob for current limitation, any value Set the current limit, this means the,,max current when the power supply should be limiting After the current limit has been set,,open the short circuit, but the power supply must be switched off before, otherwise a breaking spark could be produced 6 7