VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR

Similar documents
Internalift Pumps a better slant on water and wastewater pumping

ARKAL FILTERS CATALOGUE

DW PADDLE-BELLOWS FLOWMETER & SWITCH

AutoFilt RF3 Automatic Self-Cleaning Filter

Fluid Handling: Panel Unit

Thompson Strainer MLS-2

PRESSURE GAGES AND TEST TAPS

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

AutoFilt RF3 Automatic Self-Cleaning Filter

LT Series Lubricant Management System (LT-LMS)

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

MAP Automatic Strainers In-Line Series

MODEL 900 IMPELLER-TYPE FLOW METER

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

ejpx High Efficiency Liquid-Solid Separator ejpx Features and Benefits:

HMF, SMF & BMF Media Filters

BERMAD Irrigation. Media Filtration Systems. Model Filters. Features and Benefits. Typical Applications

Filtomat M100/MG Filters

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

HTX-HTH SEPARATORS I&O MANUAL

ISTEC MAGNETIC METERS

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL

MODEL 200 MULTI-JET FLOW METER

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

HYDROCYCLONE SAND SEPARATORS

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Mobrey MSM400 Ultrasonic sludge density measurement system

AUTOMATIC FILTER & STRAINER SELECTION PG. 3 FI SERIES SINGLE BAG FILTER HOUSINGS PG. 4 FI MULTI BAG FILTER HOUSINGS PG. 6

Dome-Loaded Pressure Reducing BD-Series

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

To ensure proper installation, digital pictures with contact information to before startup.

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

New Filtration Products from LAKOS

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

Motorized Stainless 2-Way Valves

AMIAD Automatic Filters

M300 Filters. Versatile and efficient self cleaning hydraulic filters that require no external power source

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

Scale Feeder Manifold Water Filtration System Instruction Manual

Separator Systems Operations & Maintenance Manual

IONIZATION SOLUTIONS

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

ProFlo FatBoy

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Aqua-Clear Fiberglass Sand Filters

EZ SDI TM Booster Pump Assembly

TPHK Series Immersible Pump

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

ProCS and ProC Series Heat Trace Panelboards

Series 3730 Electropneumatic Positioner Type

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

PUMPS AND FILTRATION

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

PowerFLO 5800/5900 Series

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

Tuffy Liquid Level Switches

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Off-Line Filtration OFF-LINE FILTRATION

Check List for Optimal Filter Performance

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

CIRCLE SEAL CONTROLS

BLAST-TEC PRO. Rotating Turbo Nozzles. Optimization & Troubleshooting Guide REV C revc0118

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

800 Series Control Valves

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC


PRA Centrifugal pumps

MODEL 200 MULTI-JET FLOW METER

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

AMIAD "TAF" FILTER SERIES

Laboratory Lubricated Vane Vacuum System with Premium NFPA Controls

Technologies. Universal Fuel Purifiers

Pump Specifications FL100 Series Submersible Effluent Pump

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS

THE LEADING FORCE behind liquids TM since Rotary Positive Displacement Pumps

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

AMIAD "ABF-L" FILTER SERIES

Operating Instructions

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

DVX-DUPL DFS DVF-64, DVF-65 DVX. CLEANDiesel Vessels, Housings & Skid Systems DVF-64, DVF-65, DVX, DV, DVF, DFS

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.

Series RFLD Duplex In-Line Filter

Transcription:

VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR GENERAL INFORMATON Evoqua s VAF TM brand Hydrocyclone Separators are effective in removing suspended particles from any flow stream of water where the specific gravity (density) of the particle(s) is heavier than the fluid it is in. The more significant the difference in gravity between the water and the particle, the greater the efficiency of the removal process. Depending on the specific gravity of the particle and the viscosity of the flow stream, very small and denser particles can be removed. Particulate removal can be enhanced if multiple passes of the stream can be achieved. Consider a separator s use where any source of water contains contaminants with a weight of 2.6 specific gravity or higher, such as well water to remove sand. Separators are also excellent for use as a preremoval device for filters with river or ditch water that contain high levels of sand or other large organic debris. Applications would include, but not be limited to, wells, industrial processess, water reycling and reuse, river and ditch water intake systems, food processing nozzle systems and irrigation water. Features/Benefits No Moving Parts Removal of 98% Solids 2.6 Specific Gravity and Higher at Maximum Flow Rate (see back side) Heavy Duty, Corrosion Resistant Construction for a Long Service Life No Electricity Required Capacities of 1 to 1,771 m 3 /hr (4 to 7,800 gpm) Operating pressure 1.5 to 10 bar (25 psi to 150 psi) Simple Installation Excellent Pre-removal to Reduce Load on Downstream Filtration Components Low Cost Made in the USA Custom Skids Available HOW IT WORKS Liquids and solids enter the unit and begin travelling in a circular flow. This centrifugal action forces heavier particles downward in a spiral motion to the separation chamber. The particles collect in this separation chamber and are purged from the system on a time interval. The processed water is drawn from the separator s vortex and up through the outlet.

PARTICLE REMOVAL EFFICIENCIES Flush Valve

VERTICAL SEPARATOR SPECIFICATIONS MODEL FLOW LINE SIZE LENGTH WEIGHT FLUSH SIZE M 3 /HR GPM CM IN CM IN KG LBS CM IN VHS-10 1-2 4-10 1.3 0.5 54.6 21.5 6 13 VHS-20 2-5 10-20 1.9 0.75 54.6 21.5 7 15 VHS-40 4-9 18-38 2.5 1.0 77.5 30.5 12 26 VHS-50 6-12 26-52 3.2 1.25 77.5 30.5 12 26 VHS-80 9-18 38-79 3.8 1.5 77.5 30.5 12 26 VHS-120 14-27 63-120 5.1 2.0 96.5 38 20 44 VHS-180 23-41 100-180 6.4 2.5 111.8 44 25 55 VHS-260 28-59 125-260 7.6 3.0 121.91 48 34 75 VHS-340 43-78 190-345 10.2 4.0 124.5 49 55 120 2.54 1 5.08 2 ANGLED SEPARATOR SPECIFICATIONS MODEL FLOW LINE SIZE LENGTH SHIPPING LENGTH WEIGHT FLUSH SIZE M 3 /HR GPM CM IN CM IN CM IN KG LBS CM IN VHS-400A 45-91 200-400 10.2 4.0 203.2 80 221 87 127 280 VHS-700A-LF 83-159 365-700 15.2 6.0 269.9 106.3 293.4 115.5 224 493 VHS-950A-LF 114-216 500-950 15.2 6.0 269.9 106.3 293.4 115.5 224 493 VHS-1600A 182-363 800-1600 20.3 8.0 289.6 114 316.9 124.8 328 722 VHS-2300A 295-522 1300-2300 25.4 10.0 313.7 123.5 342.9 135 382 840 VHS-3400A 460-772 2025-3400 30.5 12.0 353.1 139 396.2 156 636 1400 VHS-5000A 676-1136 2975-5000 35.6 14.0 387.4 152.5 424.2 167 907 2000 VHS-6200A 909-1408 4000-6200 40.6 16.0 406.4 160 462.3 182 1048 2310 VHS-7800A 1136-1772 5000-7800 45.7 18.0 449.6 177 487.7 192 1248 2750 5.08 2 NOTES: Standard construction material is carbon steel. Other options are available including stainless steel and seawater compatible models. VHS = VAF TM Hydrocyclone Separator Unless otherwise noted, ALL models are installed vertically with legs. A = Mounted 22.5 angle, Supplied with Support Legs LF = Low Flow HF = High Flow AUTOMATIC-PURGE TIMER CONTROLLER AND MOTORIZED BALL VALVE Models Available Model Description PVB-1LT-120 1 Auto-Purge Timer PVB-2LT-120 2 Auto-Purge Timer Auto-Purge Timer includes 120 VAC controller with LCD display with push button controls and brass ball valve. Other options, voltages and materials available.

ANGLED SEPARATOR DIMENSIONS (CM) INLET/ OUTLET 4 LF6 HF6 8 10 12 14 16 18 CM A 123.2 160.0 160.0 180.3 198.1 259.1 260.4 274.3 301.0 B 118.1 151.1 151.1 165.1 180.3 191.3 216.9 226.8 249.7 C 118.1 153.4 149.4 167.6 184.9 194.3 220.0 228.6 254.8 D 40.6 52.1 52.1 55.4 53.3 60.5 62.2 62.0 68.6 E 48.3 52.8 52.8 57.4 62.2 67.6 70.6 73.7 85.3 F 19.1 26.7 26.7 30.5 33.0 36.3 30.5 30.5 38.1 G 48.3 55.9 55.9 62.2 73.7 81.3 85.1 85.1 87.6 H 10.2 14.7 13.5 14.2 17.8 20.6 22.9 22.9 27.9 J 16.8 27.4 27.4 32.5 40.6 45.7 50.8 61.0 71.1 K 30.5 40.6 40.6 45.7 55.9 66.0 71.1 76.2 91.4 L 203.2 269.9 269.9 289.6 313.7 353.1 387.4 406.4 449.6 M 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 N 12.7 12.7 12.7 12.7 12.7 12.7 15.2 15.2 15.2 P 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 X 55.9 76.2 76.2 86.4 106.7 127.0 127.0 137.2 146.7 Y 35.6 35.6 35.6 40.6 50.8 61.0 66.0 71.1 75.6

ANGLED SEPARATOR DIMENSIONS CONTINUED (IN) INLET/ OUTLET 4 LF6 HF6 8 10 12 14 16 18 IN A 48.5 63.0 63.0 71.0 78.0 102.0 102.5 108.0 118.5 B 46.5 59.5 59.5 65.0 71.0 75.3 85.4 89.3 98.3 C 46.5 60.4 58.8 66.0 72.8 76.5 86.6 90.0 100.3 D 16.0 20.5 20.5 21.8 21.0 23.8 24.5 24.4 27.0 E 19.0 20.8 20.8 22.6 24.5 26.6 27.8 29.0 33.6 F 7.5 10.5 10.5 12.0 13.0 14.3 12.0 12.0 15.0 G 19.0 22.0 22.0 24.5 29.0 32.0 33.5 33.5 34.5 H 4.0 5.8 5.3 5.6 7.0 8.1 9.0 9.0 11.0 J 6.6 10.8 10.8 12.8 16.0 18.0 20.0 24.0 28.0 K 12.0 16.0 16.0 18.0 22.0 26.0 28.0 30.0 36.0 L 80.0 106.3 106.3 114.0 123.5 139.0 152.5 160.0 177.0 M 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 N 5.0 5.0 5.0 5.0 5.0 5.0 6.0 6.0 6.0 P 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 X 22.0 30.0 30.0 34.0 42.0 50.0 50.0 54.0 57.8 Y 14.0 14.0 14.0 16.0 20.0 26.0 26.0 28.0 29.8 VERTICAL SEPARATOR DIMENSIONS INLET/ OUTLET 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 CM A 54.6 54.6 77.5 77.5 77.5 96.5 111.8 122 124.5 B 15.2 15.2 15.2 15.2 15.2 20.3 25.4 25.4 30.5 C 6.1 6.1 8.6 8.6 8.6 11.4 11.4 14 16.8 D 6.4 6.4 6.4 7.1 7.1 8.4 11.4 12.5 16.5 E 2.5 2.5 2.5 2.5 2.5 5.1 5.1 5.1 5.1 INLET/ OUTLET 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 IN A 21.5 21.5 30.5 30.5 30.5 38 44 48 49 B 6 6 6 6 6 8 10 10 12 C 2.4 2.4 3.4 3.4 3.4 4.5 4.5 5.5 6.6 D 2.5 2.5 2.5 2.8 2.8 3.3 4.5 4.9 6.5 E 1 1 1 1 1 2 2 2 2

FLOW AND PRESSURE LOSS CHARTS Smaller Separators Larger Separators

AUTO-PURGE CONTROL SPECIFICATIONS An automatic purge controller and valve can be used on all applications. This eliminates the need for manual flushing, turning the separator into an automatic system. SPECIFICATIONS 115 VAC 50/60 hz 3 m (10 ft) power cord with plug Two-piece brass ball valve 1 or 2 NPT connection Thermosplastic top cover Epoxy powder coated metal base NEMA 1 enclosure Ambient Temperature Range: - 12 C (10 F) to 49 C (120 F) Maximum Working Pressure: - Brass: 41 bar (600 psi) - Stainless Steel (optional): 62 bar (900 psi) MODEL PVB-LT LCD cycle status display Demand draining capability External test button External keypad timing adjustment Cycle Time: 1 min to 99 hrs 59 min Open Time: 1 sec to 99 min 59 sec OPTIONS AND ACCESSORIES 12 VDC, 24 VDC, 230 VAC Stainless steel ball valve Alarm contact for remote indication of fault mode Actuator with standardized ISO mounting pad sold separately. AUTO-PURGE CONTROL DIMENSIONS AND WEIGHTS DIMENSION AND WEIGHTS (WITH STANDARD BRASS BALL VALVE) VALVE CONNECTION SIZE A B C D WEIGHT KG LB 1 NPT 2 NPT CM 21.1 17.3 16.0 10.9 IN 8.3 6.8 6.3 4.3 CM 22.6 17.3 16.8 12.2 IN 8.9 6.8 6.6 4.8 5.0 11.0 6.0 13.0

5270 Marshall St, Arvada, CO 80002 USA Phone: +1 (303) 425-4242 Fax: +1 (303) 425-0112 www.vafusa.com www.evoqua.com VAF is a trademark of Evoqua, its affiliates and subsidiaries in some countries. All other trademarks are those of their respective owners. Subject matter and images used with permission. All information presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products. 2018 Evoqua Water Technologies LLC Subject to change without notice VAF.SEPARATOR.DS.1218