Heating oven with mechanical control

Similar documents
Heating oven with natural convection

Heating oven with mechanical convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Safety drying ovens. Advantages: Areas of application: FDL series 115

Safety drying ovens with expanded temperature range

Safety drying oven with expended temperature range

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

Climate chambers with illumination

Climate chamber with illumination

Refrigerated incubator with Peltier technology

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

MDL series Safety drying ovens with first class safety features and an expanded temperature range

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

MK MKF MKT MKFT Environmental simulation chambers

FUNCTION LINE HEATING AND DRYING OVENS

Environmental simulation chambers MK MKF MKT MKFT

Dynamic climate chambers. MK MKF MKT MKFT series

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

Ovens. UL Certified Ovens WON, WOF & WOV models. WiseVen. High-Clean Air Ovens

INCUBATORS I PAGE 4-8. COMPRESSOR-COOLED INCUBATORS ICPeco PAGE COMPRESSOR-COOLED INCUBATORS ICP PAGE 19-20

GENERAL PURPOSE INCUBATOR

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY. INCUBATORS from 5 to 240 lt. OVENS from 5 to 720 lt

Flash Point Process Analyzer

Cooled incubators (ST), laboratory refrigerators

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

EAS822 (Contrac) Power Electronic Unit

Laboratory refrigerators

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

Incubators. Incubators

IKA Mixing Magnetic stirrers with heating

Mitraset 19 Housings. Housing for electronic instruments

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Industries: Aerospace. Optical Electronics ASTM Test Ovens. Automotive. Automotive Components. Petroleum Curing Ovens. Ceramics

emp. & Humid. Chambers

WATERBATHS WNB, WNE, WPE PAGE 4-9 OILBATHS ONE PAGE ADDITIONAL INFORMATION PAGE 14

STABILITY TESTING CLIMATIC CHAMBER

emp. & Humid. Chambers

AirPort MD8 Battery-Power, Portable Air Sampler

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

innovative. reliable. international ORIGINAL DÜPERTHAL NEW: active SAFETY without compromise!

Digital incubating/ refrigerating benchtop shakers.

CFPP Process Analyzer

Specification GS329 1

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

AMSCO WARMING CABINET

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

MOBILE MEASUREMENT TECHNOLOGY

Boekel Complete Culture Control Incubators

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Environmental/Analytical LabCivil Engineering Lab Equipment

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

1291BL Series Technical Specification Single Axis Position and Rate Table System

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Integrated temperature test and calibration bench Model CBS-SC4000

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Process Filtration From Pure to Sterile

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems


Guth modulating valves. The sophisticated solution

Product Data Sheet 4184 N/17X. The engineer's choice

Process Filtration From Pure to Sterile

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

Product Data Sheet 632 NU-006

PRODUCT VTS C LOW TEMP. FREEZERS SPECIFICATIONS DIMENSIONS FEATURES LOADING QUANTITIES BIOMEDICAL SOLUTIONS

! C A U T I O N! Damages on the machine possible.

Optidew Vision Optical Dew-Point Meter

Nexa 1200 Fuel Cell System

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

better measurement Simply a question of

Differential pressure transmitter PASCAL Ci4 Delta P

-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Shaking Incubators & Shakers

Heavy Duty Orbital Shakers

VTC-1.5 HALT/HASS Chamber Specifications

Product Data Sheet DV5214 NU


Gas Insulated Metal-clad Switchgear, HMGS!

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

EBI 12 The new data logger generation

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

INSTRUMENTATION & CONTROL

VTC- 16 HALT/HASS System Specifications

Transcription:

ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the gravity convection, thermal processes are highly efficient for this heating oven. A BINDER ED heating oven ensures fast, uniform drying. Advantages: Fast, even tempering Wide temperature range Quality "Made in Germany" Areas of application: Biotechnology Basic Research / Research Institutes Human / Veterinary Medicine

Customer benefits Features Customer benefits Characteristics APT.line Quick drying Identical test conditions throughout the chamber interior Independent of specimen size and quantity APT.line for maximum precision Uniform circulation even under full load Homogeneous temperature conditions throughout specimen material Temperature range Inner chamber concept Standard equipment Quality Accessories and Services Broad range of applications Short warm up times Maximum occupational safety Easy loading and unloading of specimen material Easy cleaning Reliable, easy handling Reliable devices with long service lives Short delivery times Minimal maintenance and operating costs Flexible solution in terms of size, type and equipment ptimal solution for numerous applications BINDER INDIVIDUAL for customer-specific solutions Worldwide BINDER Service Standard up to 300 C Large power reserves Inner chamber made of stainless steel Very tight door closure with 2-point door latch Low heat dissipation due to 60 mm insulation Rack with tilt protection No permanent fixtures Comprehensive standards Microprocessor control Ergonomically positioned controller. RS 422 interface PT 100 temperature sensor Premium quality Highly automated Series production High-quality materials, state-of-the-art production technology High standard according to DIN 12880 (27-point measurement) Comprehensive product portfolio Size 23 to 720 liters Additional product lines with humidity, light, C2 or vacuum Voltage variants (UL) and certificates Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits Worldwide service network

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range from 5 C above ambient temperature to 300 C Digital temperature setting with an accuracy of one degree DS control with integrated timer 0 to 99,59 hrs Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm ptional RS 422 Interface for APT-CM Data Control System communication software Units up to 115 liters are stackable 2 chrome-plated racks included ED 23 with space-saving door mechanism BINDER test confirmation

Specifications ED 23 Exterior dimensions Width (mm) 435 Height (incl. feet) (mm) 495 Depth (mm) 520 Plus door handle, I-panel, connection (mm) 105 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 100 Exhaust duct (outer Ø mm) 52 Steam space volume (l) 36 Number of doors (ea.) 1 Interior dimensions Width (mm) 222 Height (mm) 330 Depth (mm) 300 Interior volume (l) 20 Racks (number standard/max.) 2 / 3 Load per rack (kg) 12 Permitted total load (kg) 25 Weight (empty) (kg) 22 Temperature data Temperature range approx. 5 C above ambient temperature to ( C) 300 Temperature variation 1) at 70 C (± K) 1,5 at 150 C (± K) 2,5 at 300 C (± K) 3,8 Temperature fluctuation at 70 C (± K) 0,3 Warm-up time 2) to 70 C (min.) 13 to 150 C (min.) 24 to 250 C (min.) 35 Recovery time after doors were open for 30 sec. 2) at 70 C (min.) 2,5 at 150 C (min.) 5 at 300 C (min.) 8

Specifications ED 23 Ventilation data Ventilation at 70 C (x/h) 10 at 150 C (x/h) 13 at 300 C (x/h) 17 Electrical data IP protection class acc. to EN 60529 IP 20 Voltage (± 10%) 50 / 60 Hz (V) 230,1N~ Nominal power (kw) 0,8 Energy consumption at 70 C (W) 43 at 150 C (W) 148 at 300 C (W) 450 1) without a viewing window 2) To 98% of the set value All technical data are specified for units with standard equipment at an ambient temperature of +25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

ptions Numerous access ports With silicone plugs for introducing external measuring instruments into the chamber, access ports with 10, 30, 50 mm diameters. Door with window and interior lighting For optimal process control in the inner chamber, available for all device sizes. Door lock Prevents unauthorized access to the process sequences in the chamber. Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.

ptions ED 23 Access ports with silicone plug, 10, 30, 50, 100 mm Anti-slip rubber pads for safe stacking (1 set of 4 pieces) Switchable audible alarm for over temperature. Adjustable limit on the independent temperature safety device Independent temperature safety device class 3.1 (DIN 12880) with optical alarm Analog output for temperature 4-20 ma with 6-pin DIN socket (output not adjustable) Temperature measurement acc. to DIN 12880 (27 measuring points, for 23 liter devices 15 measuring points) at 150 C or at specified temperature with measuring protocol and certificate Calibration certificate, measurement in center of chamber at 150 C or at specified testing temperature Extension to calibration certificate. Each additional measurement at additional measuring point or testing temperature Data Logger Kit T 350: For continuous temperature recording of 0 C to 350 C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable Rack, chrome-plated Rack, stainless steel Perforated shelf, stainless steel Door lock Door gasket, FKM (Viton) Door with window 180 x 180 mm and interior lighting (15 W)