i RANGE HYDROPATH Technology The home of

Similar documents
INSTALLATION AND USER INSTRUCTIONS

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

INSTALLATION INSTRUCTIONS

AF40... AF96 3-pole contactors Technical data

Standard Interlock Safety Switches

Thermal Overload Relays - WEG RW Series, 2 Pole

T2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc

Technical Information

HS1E Series Full Size Solenoid Locking Switches

System 3 ZB1PS Device Chassis. Operator s Manual

Safety Standards. Model Number:

Technical data for manual motor starters Type MS325

Door Interlock Switches

NR Rack Installation Guide

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Constant Running Hydraulic Pump Installation Guide. Document Number: Date: March 2006

MODVAR Low voltage reactive power compensation modules Installation manual

HS5D Miniature Interlock Switches

Door Interlock Switches

I n s t a l l a t i o n M a n u a l. f o r T E D

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

HS6B Series Subminiature Interlock Switch

HS5D Miniature Interlock Switches

Essential equipment for all your requirements

Electrak powertrack / underfloor busbar system

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

7 Lighting Technology

Dimensions WxHxD [mm] Weight [kg]

MK Electric IP Solutions

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

Safety Lampholders and Pendants

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

SOLSTART Instruction Manual

MODEL 422 Submersible Pump Controller

CAUTION CM-SE CM-S21 CM-S41

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Oiltight Switches & Pilot Devices

Compact Sine Inverter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

INSTRUCTION & INSTALLATION

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

MF4E MF4E

MPA Chassis for Multi-Probe Magnetic Transducers

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

STAPS Wireless Steam Trap Monitoring System

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

BS 2/K Transverse Conveyor

Model DS1000/DT20 System

PSU EN54-4 Power Supplies

CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Uninterruptible Power Supplies

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

KEWTECH. KT56 digital multi function tester. Instruction manual

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Cellwatch Electrical Installation

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

SWING DOOR SOFT ENCLOSURE (part# 16733)

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Instruction Manual. Q Series 2 Motor Control Modules - OEM

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708

LV Capacitor CLMD03 Power Module Instruction manual

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

FlexJet - Flex Cable Replacement

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

SafeSite LED Based Signaling for Hazardous Locations

RE SERIES RACK INSTALLATION GUIDE

Power Factor Correction Capacitors Type LKT

INSTALLATION MANUAL P2068. Level of Difficulty. Parts List. Product Image. Notes and Maintenance. Tools Required. Easy

2015 Ford F150 Front Bumper w/ LED

Solenoid Locking Safety Switches

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

SafeSite LED Based Signaling for Hazardous Locations

Transcription:

i RANGE HYDROPATH Technology The home of

Input Voltage 87-240V AC Input Frequency 47-63 Hz Material Specifications Main unit: Anodised Aluminium End plates: UL V-0 rated polycarbonate Water and Dust Protection IP Rating: IP68 IEC 60529 (Transducer unit) IP66 IEC 60529 (Junction box) Built-in EMI Filter Meets: FCC 20780 Class B VDE 0871 Level A Safety Europe and Worldwide: IEC51010-190+A1:92 +A2:95 ~EN61010 Tested accorded to CENELEC National Requirements USA: UL3101-1 Canada: CSA22.2 No:1010.1-92 Over-voltage (Transients) 10 to 20% above nominal Environmental Specifications Installation category: Cat II; Altitude: <2000 Mtrs (6562 ); Operating Temperature: -20 to + 50º C (-4 to 122ºF); Maximum relative humidity; Max 80% up to 31ºC (87º F) decreasing linearly to 50% RH at 40º C (104º F) Overload Protection Insulation Continuous short or open circuit on all outputs. Basic insulation with the metal enclosure bonded to earth. Servicing No user repairable parts are fitted. Repair must be undertaken by an authorised repair centre. Panel Indicators The PSU is fitted with LED indicator lights. The Green LED indicates that the power is on, and the Red indicates that a signal is being transmitted. CSA Certification and CB Test Certificate In accordance with the International (IEC) and UL/CSA standards listed above. Manufactured to BSEN9002 To be installed in accordance with the latest IEE wiring instructions. Fuse rating: 1A. To be installed in accordance with the latest IEE wiring instructions. Fuse rating: 1A. All goods are supplied subject to our standard Terms and Conditions, copies of which are available upon request.

Electrical Conditioner unit User mains and BMS connection Junction box Fuse L E User mains and BMS connection Connection to unit N Junction box BMS Relay Inner grommet allows for connection to different cable diameters Remote Monitoring Facility A volt-free normally-open contact closure is provided by the unit connection with a BMS (Business Management System) computer, to monitor that the unit is operating correctly. Connection to the BMS output is made via the junction box. A suitable 5 core approved cable must be used in order to make connection to the mains input and the BMS output. Electrical Connection The user must connect the electrical supply to the junction box in accordance with the onsite ruling safety legislation at the time of installation. This is the sole responsibility of the user and the site safety officer must be consulted before installation is undertaken.

Mechanical Details The HydroFLOW i Range water conditioner is specifically designed to combat limescale in commercial and/or industrial applications by clustering mineral ions, to enhance filtration by flocculating particles and to combat biofouling. i Range units are most commonly used on heat exchangers and plumbing systems. Model Ferrite Arrangement Dimensions mm (inches) Ferrites Total Weight kg (lbs) i45 Arrow indicates longer 126mm ferrite 38mm pipe (1.5 ) 219.4 (8.63 ) 140.1 (5.51 ) 3 x 109mm (4.25 ) 1 x 126mm (5.0 ) 4.0 (8.8) 219.4 (8.63 ) i60 157.5 (6.2 ) 4 x 126mm (5.0 ) 4.2 (9.2) 55mm pipe (2.2 ) i100 Arrow indicates longer 126mm ferrite 104mm pipe (4.1 ) 219.4 (8.63 ) 199.6 (7.85 ) 5 x 109mm (4.25 ) 1 x 126mm (5.0 ) 4.4 (9.7) 219.4 (8.63 ) i120 229.2 (9 ) 6 x 126mm (5.0 ) 4.6 (10.1) 130mm pipe (5.1 ) 219.4 (8.63 ) i160 296.1 (11.65 ) 8 x 126mm (5.0 ) 5.8 (12.8) 200mm pipe (7.8 ) All units draw less than 1 amp of current at 120V AC Listed weights include: Transducer unit, power supply, ferrites, cables and mounting hardware.

DO NOT POWER UP UNIT UNTIL ALL FERRITES SUPPLIED ARE CONNECTED. The unit is supplied with a bracket for ease of mounting to the pipe. The two upper plates should be loosely secured with bolts before installation. Smaller units are secured to the pipe using steel clamps and bolts Unit support bracket Banding slots Pipe Clamp For larger units, the brackets are supplied with stainless steel banding. Pass the two stainless steel bands through the slots in the bracket. Banding Place the bracket on the pipe. If installing on a vertical pipe, place the bracket with the smaller plate upwards to ease fitting of hexagon nuts. Tighten steel hex nuts to secure clamps for smaller units Secure straps on larger units by tightening clamps with flathead screwdriver or hex socket driver Banding clamps! WARNING The system must be used as specified. Failure to do so will prevent correct operation of device and may impair safety.

DO NOT POWER UP UNIT UNTIL ALL FERRITES SUPPLIED ARE CONNECTED. Place the unit on the bracket and hold in place using the swinging plates. Secure by tightening the four steel nuts. Plate Plate Insert the two hexagon nuts into the holes in the end plate, next to the ferrite holding cage. The transducer unit is supplied with at least one long ferrite bar. Insert this through the holding cage until the holes line up with the hexagon nuts. Ferrite bars Hexagon Nuts Take a second ferrite, insert a plastic thumb screw through both ferrite bars and loosely screw into hexagon nut. Repeat on opposite side. Thumb screws! WARNING The system must be used as specified. Failure to do so will prevent correct operation of device and may impair safety.

DO NOT POWER UP UNIT UNTIL ALL FERRITES SUPPLIED ARE CONNECTED. Assemble all the other ferrites around the pipe according to the mechanical configuration specified for the unit. Loosely secure each ferrite with plastic thumb screws and thumb nuts. Thumb screw Thumb nut Once the ferrite ring is complete, tighten all wing nuts until hand tight. Do not over tighten as ferrites are fragile. In accordance with local code and regulations, connect the junction box to the electrical power supply (87V-240V AC). Energise the electrical power supply and ensure that the Red and Green LED lights on the unit are glowing brightly. Junction box 87 240V electric supply! WARNING The system must be used as specified. Failure to do so will prevent correct operation of device and may impair safety.

The i Range unit can provide a range of benefits, including protection against limescale, treatment of biofouling and flocculation of particles. The most effective location for the unit depends on the result desired. For protection against Limescale due to heating, the unit should be fitted on the cold feed to where the water is heated. For protection against limescale, the unit should be fitted after any pumps or filters as these can degrade the conditioning effect. To enhance flocculation, the ideal location is before the pump feeding a filter. An electrical loop is created whenever an electrical connection is made from one side of the ferrite loop to the other, e.g. by metal supports, wiring or pipework. A loop will prevent the unit from operating correctly. This problem can be solved by moving the unit outside the electrical loop. If this is not possible, the metal support brackets can be electrically insulated. Installing the unit on a section of plastic pipe eliminates the possibility of an electrical loop. Brackets create loop Electrically insulate brackets Wiring creates loop Move unit out of loop If you are unsure of any details of fitting or installation, please contact your local Hydropath representative for technical support.

Box Contents Transducer Unit Instructions Model Long ferrites Short Ferrites Plastic Hex Nuts Plastic Thumb Screws Plastic Thumb Nuts Steel Bracket Steel Bands Pipe clamps 50mm bolts Steel locking nuts i45 1 3 2 4 2 1 0 2 4 4 i60 4 0 2 4 2 1 0 2 4 4 i100 1 5 2 6 4 1 2 0 0 0 i120 6 0 2 6 4 1 2 0 0 0 i160 8 0 2 8 6 1 2 0 0 0 To register the product please visit hydropath.com/product-registration/ Products must be registered to activate any warrantee or guarantee. All goods are sold subject to our standard terms and conditions of sales, copies of which are available upon request.

HYDROPATH.COM

HYDROPATH Technology The home of