ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Similar documents
MIXVENT-TH Series Mixed Flow Fans

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Short casing. Long casing (L version) Commercial premises

COMPACT Series type HCFB / HCFT (Plastic impellers)

BELT DRIVEN CABINET FANS CVTT Series

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

CVHT Series - F rated cabinet fans

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

supplied in Form (B) configuration. Airflow over Impeller- Motor.

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

TGT Series Adjustable Pitch Fans

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS CVB / CVT Series

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

TGT Series Adjustable Pitch Fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CENTRIFUGAL IN-LINE FANS VENT Series

TD-SILENT Series (160 to 1000 models)

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

TD-SILENT range, the quietest fans in the world in their class

IN-LINE CENTRIFUGAL DUCT FANS VT Series

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

DIRECT-AIR ILB / ILT Series Rectangular duct fans

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

TD-SILENT range, the quietest fans in the world in their class

GigaBox centrifugal fans Product specific information

ACOUSTIC CABINET FANS CVAB / CVAT Series

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

Vent-Axia Sabre Sickle Roof Fans (VSR)

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Mixed Flow Roof Fans (RMH)

AXIAL FLOW CABINET FAN CGT Series

Mixed Flow Roof Fans (RMH)

SILENT MV Ultra Quiet In-line Fans

Performance. Sound Levels. Impellers. Motors. Accessories

Sabre Sickle Fan Assisted Roof Cowls (VSR)

BATHROOM EXTRACT FANS DECOR-100 Series

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

Sabre Plate Mounted Sickle Fans (VSP)

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Multifunctional 400ºC/2h and 300ºC/2h roof fans

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

Plate mounted axial flow fans HXBR / HXTR Series

CHMT Series, F Rated Fans

CYLINDRICAL CASED AXIAL FLOW FANS

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Uniclass L7534. Manufacture controlled to ISO9001

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

TD-ECOWATT AND DECOR-ECOWATT Series

Practical examples of installation in the TD range

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

MegaBox Product-specific information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Centrifugal medium-pressure fans fitted with multi-blade

Axial fans. What s more, non-stock models are normally available within two weeks.

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Square Mixed Flow Fans (MFQ)

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

Acoustic Twin Fans (ATQ)

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

NEW Acoustic In-Line Fans (ACQ)

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

Uniclass L7534. Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Transcription:

MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength injection moulded plastic, and models 1300 and 2000 from high grade pressed sheet steel. The bases are manufactured from sheet steel. The cowls are manufactured from pressed sheet steel (500 and 800 models) or spun aluminium (1200 and 2000). ll models incorporate a bird guard and base cable gland entry point as standard. ll metallic parts are protected with a black epoxy-polyester weatherproof paint coating. The motor and impeller casing can be easily removed by 2 fixing clamps. Motors ll motors are IP44, lass, equipped with thermal protection and ball bearings Roof mounted fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements greased for life. Electrical supply: Single phase 230V-50Hz (apacitor located inside the wiring terminal box). ll motor are two connections also suitable for voltage control using electronic or auto-transformer controllers. dditional Information The motor and impeller casing can be removed and turned through 180º to provide supply air ventilation. Flame retardant terminal box ircular spigot coupling ird-proof guard Very accessible wiring terminal box in flame retardant plastic V0, with capacitor located inside ircular spigot coupling to facilitate the connection of circular, rigid or flexible 216

I Technical characteristics efore installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Speed (r.p.m.) Max. power abs. (W) Max. current abs. () Max. air volume (m3/h) TH-500/150 EXTRT 2450 1800 68 40 0,26 0,19 470 355 60 49,5 3,8 Max. temp. (º) SPL* (d()) SUPPLY 2450 1800 67 40 0,25 0,19 505 380 60 45 3,8 TH-500/160 EXTRT 2450 1800 68 40 0,26 0,19 470 355 60 49,5 3,8 SUPPLY 2450 1800 67 40 0,25 0,19 505 380 60 45 3,8 TH-800N EXTRT 2500 2100 90 75 0,4 0,31 790 630 60 50 5,6 SUPPLY 2500 2050 90 75 0,4 0,31 880 695 60 48 5,6 TH-800 EXTRT 2500 2100 140 118 0,58 0,52 775 620 60 53 5,6 SUPPLY 2500 2000 140 118 0,58 0,52 860 695 60 52 5,6 TH-1300 EXTRT 2400 1800 170 120 0,83 0,52 1100 780 60 59,5 11,2 SUPPLY 2400 1800 172 110 0,76 0,49 1150 845 60 58,5 11,2 TH-2000 EXTRT 2480 1750 255 160 1,27 0,79 1725 1200 60 67 17,2 * Sound Pressure Level SUPPLY 2480 1800 300 190 1,27 0,79 1650 1245 60 63,5 17,2 Dimensions (mm) H 4 HOLE Ø F G Weight (Kg) D E F G H I TH-500/150 400 349 300 150 245 10 20 274 33 TH-500/160 400 339 300 160 245 10 20 274 33 TH-800 N 400 371 300 198 245 10 20 306 36 TH-800 400 371 300 198 245 10 20 306 36 TH-1300 546 457 435 248 330 12 20 372 42 TH-2000 735 544 560 312 450 12 20 450 50 Ø D E coustic characteristics (SPL) The values of the sound levels given in the technical characteristic chart are sound pressure levels measured in d() at a distance of 3 m with the maximum airflow. To obtain the sound power level at or, for extract operation, add to the sound pressure level (SPL Extract) given in the Technical haracteristic chart, the correction value shown in the following table. (SPL) (SWL) SPL: Sound Pressure Level SWL: Sound Power Level (SPL) Sound power level for extract operation Frequency bands Hz 125 250 500 1000 2000 4000 8000 TH-500-7,5-3 9 6 11 4-2 -7,5 6 13,5 17,5 14,5 4,5-3 TH-800N -7,5 3,5 8 9,5 14 9 0-4 7,5 15 16 14,5 9 1,5 TH-800-7,5 3,5 8 9,5 14 9 0-4 7,5 15 16 14,5 9 1,5 TH-1300-13,5 0 1 12 9 4 0-11 5,5 11,5 17,5 15 7-0,5 TH-2000-21,5-7 -3 7 5,5-2 -8,5-16,5 2,5 7 20 7,5 1-8 217

Performance curves Extract operation Q = ir volume in, m 3 /hr and m 3 /s. Pe = Static pressure in and. Dry air at 20º and 760 mmhg. ir flow data in accordance with the following standards: UNE 100-212-89, S 848, rt 1; M 210-85 and SHRE 51-1985. HS: Speed LS: Speed MIXVENT-TH Roof mounted fans 218

Performance curves Supply operation Q = ir volume in, m 3 /hr and m 3 /s. Pe = Static pressure in and. Dry air at 20º and 760 mmhg. ir flow data in accordance with the following standards: UNE 100-212-89, S 848, rt 1; M 210-85 and SHRE 51-1985. HS: Speed LS: Speed 219

ROOF MOUNTED FNS TH-800 EX NEW Roof mounted mixed flow fan manufactured in antistatic plastic material, with base and cowl manufactured from sheet steel protected with black polyester paint coating and fitted with single-phase explosion proof motor 230V- 50Hz, increase safety II2G EExe IIT3. II2G EExeIIT3 E-type Examination ertificate nr. LOM 08TEX2052 X Roof mounted fans TH-800 EX Technical characteristics Motor type EExe coustic characteristics Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current () irflow at free discharge m 3 /h Performance curves Maximum operating temperature ( ) Sound pressure level* (d()) TH-800 EX IIT3 2480 76 0,57 800 40 57 5,6 * Sound pressure level measured in d(), at 3 m, at the fan discharge, in free field condition INLET OUTLET 63 125 250 500 1.000 2.000 4.000 8.000 Lw Lp SP = 0 27 43 53 61 69 69 65 56 73 53 SP = 80 29 43 55 62 69 70 66 56 74 53 SP = 160 39 49 69 71 74 70 63 55 78 57 DES = 0 50 50 53 64 69 71 66 56 74 54 DES = 80 44 45 54 66 70 71 67 57 75 55 DES = 160 39 48 68 72 75 71 64 55 78 58 RD = 0 7 38 37 44 58 61 52 39 63 43 RDITED RD = 80 9 38 39 45 58 62 53 39 64 43 RD = 160 19 44 53 54 63 62 50 38 66 46 Weight (kg) Q = ir volume in, m 3 /hr and m 3 /s. Pe = Static pressure in and. Dry air at 20º and 760 mmhg. ir flow data in accordance with the following standards: UNE 100-212-89, S 848, rt 1; M 210-85 and SHRE 51-1985. Dimensions (mm) Specific accessory for TH-800 EX OPEL EX-200/160 Proof explosion flexible connection 200 160 For more information see mounting accessories. 220

Mounting accessories Duct to prevent any contact between the R and the impeller 1 2 3 4 5 6 7 Flat roof upstand ackdraft shutter Flexible Flexible acoustic Worm drive clips Sealing frame Support base for curb mounted installations TH-500/150 JMS-300 JS-300 R-150 GS-150 GSI-160 X-215 I-3 TH-500/160 JMS-300 JS-300 R-160 GS-160 GSI-160 X-215 I-3 TH-800 N JMS-300 JS-300 R-200 GS-200 GSI-200 X-250 I-3 TH-800 JMS-300 JS-300 R-200 GS-200 GSI-200 X-250 I-3 TH-1300 JMS-435 JS-435 R-250 GS-250 GSI-250 X-315 I-4 TH-2000 JMS-560 JS-560 R-315 GS-315 GSI-315 X-315 I-5 1 Sealing Frame JMS: For mounting the roof fans on an up stand or base Provided with screws and gasket for a complete seal E F E F JMS-300 470 290 245 50 70 JMS-435 600 420 330 50 70 JMS-560 725 545 450 50 70 2 Flat Roof Up stands JS: For mounting fans on flat roofs with no up stands Internal insulation to avoid condensation Provided with screws and gasket for a complete seal 300 G E G JS-300 470 289 245 300 380 JS-435 600 419 330 300 510 JS-560 725 544 450 300 635 7 I support base for inclined curb mounted installations: To ensure the proper installation of the I product it is essential to specify the roof pitch angle and the distance between the roof beam profiles (as shown) 50 a Viewed VISTO in POR direction d d: distance between the roof beam profiles a: roof pitch angle (curb) I-3 289 245 I-4 419 330 I-5 544 450 221

R ackdraft Shutter GS Flexible aluminium X Worm drive clips GSI coustic aluminium REGUL-2 and OM-2 Two switches RE Electronic, single phase controller SIL Sound attenuator 222