Electronic Bidet Seat

Similar documents
INSTALLATION GUIDE. Electronic Bidet Seat. BEYOND TECHNOLOGY Powered by TOTO

Geberit Assisted Toilet Pre-Installation Instructions

DC POWER SUPPLY ALIMENTATION C.C.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

58kHz AM Deactivator DB104 Instruction Manual V1.0

Versailles Walnut Toilet Seat Versailles Walnut Toilet Seat Soft Close

Pure sine wave charger inverter Product Manual

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

VICONNECT. The clever connection

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

28W WORK LAMP Model: CTL28 Part No:

BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

Heated Bed Installation Instructions

Instruction Manual LAMI CORPORATION INC.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

8791T-C02( ) 8791T-C04(AC) 8791T-C04( ) size alkaline batteries(8791t-c02) 2 7 (AAA 2)(8791T-C02) 220V AC 50/60Hz(8791T-C04)

Diagnostic procedures (Carnival J2.9 CRDi).

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

FD Conveyor for FD 260 Tabber

WC-Unit. Assembly instructions I00128_NOV 16

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

X100P Load Bank. Read all instructions before using the load bank. Contents

Protection components

Declaration of Conformity

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Electromotoric Actuators

Owner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:

Modulating control valve PN16

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

Internet For latest information, PDF catalogs and operation manuals

XS400 Load Bank. Read all instructions before using the load bank. Contents

LUDV control block of sandwich plate design

Operations and Service Manual. X30208 Load Bank

Lever Flush Cistern Fittings Arcade close coupled cistern ARC5C

Installation & Calibration Manual

Operating instructions Flow monitor SI / / 2013

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Thermal Circuit Breaker / Switch Series 3131

PHYSICS 6 EXTENDED PHYSICS

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Thermal Circuit Breaker / Switch Series 3131

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Turner PRO. User manual. BM61099 Rev B

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

18W Round LED Slimline Emergency Light

Avanti J Series Centrifuges Preinstallation

UL AND CODE COMPLIANCE

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Electric Vehicle Supply Equipment EVSE Vehicle Simulator

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Series AV2000/3000/4000/5000

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

Magnetic Effects of Electric Current

LED Twister II. User manual UK Version 1.0

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

PURE SINE WAVE DC TO AC POWER INVERTER

NATEF Task List A6: ELECTRICAL/ELECTRONIC SYSTEMS

Pilot Operated 2 Port Solenoid Valve for Dry Air

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

to allow a current in one circuit to operate a switch in another circuit to protect a circuit by melting if the current becomes too large

Mobility Scooters. Owners Manual

INSTRUCTIONS FOR USE

Flush Valve Systems. By SCHELL.

OPERATION & MAINTENANCE INSTRUCTIONS

Disconnecting switches type OMI, OMZI

Specifications. Fluid Ambient and fluid temperature ( C)

FIX-WHEEL RAILS. rationalisation, transportation, automation

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

Speed Controller with One-touch Fitting

AUTOMOTIVE TWO POST HYDRAULIC LIFT

3 Port Solenoid Valve

Instruction Manual & Specification

Condensation monitor

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve

OPERATION & MAINTENANCE INSTRUCTIONS

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

ELECTRO HYDRAULIC THRUSTERS

Preinstallation Requirements for Avanti J Series Centrifuges

DUAL FLUSH VALVE SKIPPER 45 BOTTOM INLET VALVE COMPACT 99B ASSEMBLY INSTRUCTIONS

Hydraulic primary unit Type ABPAG

Operating Instructions

PD-Series Ground Fault Circuit Protection

SUBMERSIBLE WATER PUMP

WARNING WARNING WARNING. English Quick start guide CAUTION CAUTION. Installation Precautions

Silent centrifugal air heater hot water supply

ELECTRIC CAR POLISHER

Page 1 of 19. Website: Mobile:

Thermal Circuit Breaker / Switch Series 3131

ACTUATORS GENERAL CATALOG

Intext Exercise 1 Question 1: Why does a compass needle get deflected when brought near a bar magnet?


Class X Chapter 09 Electrical Power and Household circuits Physics

Soft Start-up Valve. AV2000/3000/4000/5000 Series

OPERATION & MAINTENANCE INSTRUCTIONS

Transcription:

Electronic idet Seat Powered bytoto

Installation Guide efore installation, be sure to read this installation guide and the separate safety sheet. Mount parts properly according to the instructions. Precautions before installation Only turn on the electricity and water supply for the product after all other installation work has been completed. Do not damage the connection components on the water supply hose (C-3). The water supply pressure range is between 0.1MPa (dynamic) and 1.0MPa (static) in Europe. Use the unit within the specified pressure range. The water temperature must be within a range of 0 to 35 C. Make sure the temperature is within this range. The ambient temperature during operation must be within a range of 0 to 40 C. Make sure the temperature is within this range. s a water flow test is conducted on each product at the factory, a small amount of water may remain inside the product. This water does not indicate a problem with the product. ll-pole disconnection incorporated in the fixed wiring shall be provided. Symbols and their meanings This task must be carried out by the installer. This function is performed automatically by. Visual confirmation is required for this. Indicates the workflow direction. 2

Specifications Check the appropriate type for your mains connection in the table below, and then wire and install the product correctly. Rated power supply Rated power consumption Maximum power consumption Power cord length 220 240V alternating voltage, 50 Hz (fluctuating) 845-855W (fluctuating) 1528W (t a water supply temperature of 0 C) 0,62 m Prepare an outlet position in advance that conforms to the regulations in your country. 3

Included Parts -1-2 C-1-3 -4-5 C-4 C-2 nti-theft protection for the remote control Please ask the home owner if he would like to have the remote control anti-theft kit installed before starting installation. Please leave the anti-theft kit with the owner if it is not installed. C-3-6 -8-7 -9 4

Required tools/items -1-2 -3-4 Use a soft, damp cloth to prevent damage to the product. -5-6 -7 Ø = 3 mm 2x Ø = 6 mm -8-9 -10-11 5

Connection Possibilities Without ViConnect. Please follow the indications in this manual. Characteristics: Two water connections are needed, one for the flushing of the WC and another one for the shower toilet When looking towards the wall mount, the electric connection is located on the left, whereas the water connection on the right. The connections will not be visible after the installation efore the WC is mounted, the water and electric connections must be already attached on the wall. efore the shower toilet is mounted, the water connection should be attached to the inlet of the seat. 4

Connection Possibilities With ViConnect Please follow manual provided with ViConnect set! 9224 61 00 9218 51 00 9221 15 00 Characteristics: Only one water connection is necessary. oth, the seat and the toilet will use the same one. When looking towards the wall mount, the electric connection is located on the right, whereas the water connection on the left. The connections will not be visible after the installation efore the WC is mounted, the water and electric connections must be already attached on the wall. efore the shower toilet is mounted, the water connection should be attached to the inlet of the seat. 5

355 mm 320 mm 255 mm 220 mm Installation procedure 1 Switch the circuit breaker in the fuse box to OFF. 180 mm 190 mm -8 C D C-3-2 2 30 cm -9 C D E Phase Neutral Earth 6

3 4 5-6 -8 6-9 -6-6 -6 7-8 7

8-6 C-3 C-1 Press C-1 into -6 until C-1 engages with a click. (fter C-1 is mounted, make sure that it cannot be removed even if it is pulled.) 8

9 Switch the circuit breaker in the fuse box to ON. 9

1060 mm 760 mm 1060 mm 760 mm Mounting the remote control 10-3 -1 C 11 300 mm -1 Side wall 250 mm 390 mm 250 mm -1 Rear wall 10

12 Temporarily place the remote control in the position determined in 11 and check the signal reception at -1. Hold down -1-4 C C-4 13 C 11 11

13 Ø = 6 mm Ø = 3mm -5-5 -2-1 -2-1 -5-4 -4 C -2-1 nchored by magnet. 12

nti-theft protection for the remote control 12 13-2 Ø = 6mm Ø = 3mm -5-5 C -2-1 -2-1 -5-4 -4 D -1 E -2-1 13

Trial run 14 Open the water shutoff valve (-8). -8 15 C Hold down Hold down -1-4 -3 16-1 C-4 14

594mm 260mm 485mm 547mm Dimensions 390mm 134 mm 220mm 64mm 392mm 92 538 mm Information for the installer Please explain the features and operation of to the customer. If the product will not be used for a long time (for example, when it is installed in an unoccupied, newly constructed building), switch the circuit breaker in the fuse box to OFF. For information on How to dismount the main unit, please refer to the separate sheet. 15

GERMNY Villeroy&ochG athroom and Welness Division Headquarter D - 66693 Mettlach EN 08-2015 Colours and dimensions are subject to commonly accepted tolerances. Subject to technical changes and colourmodifications.