Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Similar documents
Ceiling swirl diffusers

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling swirl diffusers with perforated face plate

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Slot diffusers for ceiling installation

Ventilation grilles for installation into walls, sills or rectangular

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

For installation into ductwork

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Pressure relief dampers

Type VSD35. Nominal length up to 1500 mm: one spigot

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Ceiling diffuser 4DF

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling diffuser 4DE

ceiling swirl diffuser DQJ

Ceiling impulse diffuser Model PIL

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Air Displacement Vent Units

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

PRODUCT BROCHURE. Adjustable Helical Swirl Diffuser HSC-AD HSC-AD : smartemp.com

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

ceiling swirl diffuser Model DQJA / DQJR

Swirl Diffuser Model DQF

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Catalog Swirl diffuser DAL 359

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Ceiling Swirl Diffuser DQJ

WGA Long throw nozzle grille

CAV controllers Type RN

KLIMA Active Chilled Beams

Duct Nozzle Diffuser. L e

Ceiling Slot Diffuser Model DSX

NSDZ. Swirl diffusers with adjustable air control blades

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

SDV Vane Swirl Diffusers

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

WALL VENTILATION GRILLES CBP

series 90-GV Variable geometry units

CornerAir. CornerAir. Active chilled beam

Ceiling induction diffuser DISA-300

Active Chilled Beams

Round duct grille Model KG-RR

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Round duct diffuser DBB-RR

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Catalog Swirl diffuser DAL 358

Displacement flow diffusers. L e

Volume Flow Limiters Type VFL

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Active Chilled Beams

Compact Grille Model KG

DAC - Conical Diffuser. Halton DAC. Conical diffuser

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Ceiling induction diffuser DISA-601

TBV - Terminal Unit. Halton TBV. Terminal Unit

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

Nozzle Jet Diffuser Model DSA

Total comfort control

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Ventilation grille Model AL

Lint separator FLARE

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

DRUM SLOT DIFFUSER TYPE: RT350

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

LAQ Return air diffuser

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Transcription:

X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling diffusers, with manual or motorised adjustment of the air discharge direction, particularly suitable for high rooms Nominal sizes 315, 400, 630, 800 Volume flow rate range 175 1495 l/s or 630 5382 m³/h Diffuser face made of aluminium For supply air For variable and constant volume flows Discharge direction can be adjusted manually or with an actuator High penetration of air at low sound power level Optional equipment and accessories Exposed diffuser face available in RAL CLASSIC colours Horizontal or vertical duct connection Actuators for adjusting the air discharge direction Blade adjustment with actuator PD 1

General information Type Page General information 2 Function 3 Technical data 5 Quick sizing 6 Specification text 8 Order code 9 Variants 10 Dimensions and weight 11 Product details 13 Installation examples 14 Installation details 15 Basic information and nomenclature 17 Application Application Type ceiling diffusers are used as supply air diffusers for high rooms in comfort and industrial zones For mixed flow ventilation with different air patterns in heating and cooling modes Horizontal two-way supply air discharge in cooling mode High induction results in a rapid reduction of the temperature difference and airflow velocity Angled or vertical air discharge in heating mode For variable and constant volume flows For supply air to room air temperature differences from 10 to +15 K For room heights exceeding 3.8 m For suspended ceilings Freely suspended installation Ideal for use with TDC temperature difference control module Special characteristics High penetration of air at low sound power level Particularly suitable for rooms with varying heat loads Ideal adaptation of the air discharge pattern due to two sections of adjustable blades Discharge direction can be adjusted manually or with an actuator Plenum box with side entry or top entry spigot, and variant with electric actuator and inspection access Nominal sizes 315, 400, 630, 800 Description Variants Diffuser face only Connection H: Horizontal duct connection V: Vertical duct connection Parts and characteristics Circular diffuser face with two sections of adjustable blades Diffuser front frame Spigot ring Attachments Electric actuators for adjusting the air discharge direction Useful additions TDC temperature difference control module Construction features Spigot suitable for circular ducts to EN 1506 or EN 13180 Materials and surfaces Blades, front frame and spigot ring made of aluminium Plenum box and cross bar made of galvanised sheet steel Front frame, blades and spigot ring powder- coated RAL 9010, pure white P1: Powder-coated, RAL CLASSIC colour Standards and guidelines Sound power level of the air-regenerated noise measured according to EN ISO 5135 Maintenance Maintenance-free as construction and materials are not subject to wear Inspection and cleaning to VDI 6022 PD 2

Function Functional description direct the air from air conditioning systems into the room. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. allow for large volume flow rates. The result is a mixed flow ventilation for industrial and comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone. Type ceiling diffusers have adjustable blades. The air pattern can be adjusted to meet different local requirements. Horizontal air discharge is omni directional. Vertical air discharge is possible in heating mode. The supply air to room air temperature difference may range from 10 to +15 K. An actuator (optional) adjusts the blades based on demand. Schematic illustration of the, with actuator and plenum box for horizontal duct connection 5 6 4 7 8 3 1 2 1 Front frame 2 Blade 3 Spigot ring 4 Plenum box 5 Suspension hole 6 Spigot Optional 7 Actuator and cross bar 8 Inspection access PD 3

Function Air patterns cooling mode heating mode PD 4

Technical data Nominal sizes Minimum volume flow rate Maximum volume flow rate, with L WA 50 db(a) Supply air to room air temperature difference 315, 400, 630, 800 mm 175 695 l/s or 630 2502 m³/h 320 1495 l/s or 1152 5382 m³/h 10 to +15 K PD 5

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. with circular diffuser front frame, for comfort and industrial zones. For supply air only. Diffuser face with adjustable air control blades for air discharge from horizontal (0 ) to vertical (90 ) For freely suspended installation and for suspended ceilings. Ready-to-install component which consists of the diffuser face with diffuser front frame and adjustable air control blades, a plenum box with equalising element, side entry or top entry spigot, and suspension holes or suspension lugs. Spigot suitable for ducts to EN 1506 or EN 13180. Sound power level of the air-regenerated noise measured according to EN ISO 5135. Special characteristics High penetration of air at low sound power level Particularly suitable for rooms with varying heat loads Ideal adaptation of the air discharge pattern due to two sections of adjustable blades Discharge direction can be adjusted manually or with an actuator Plenum box with side entry or top entry spigot, and variant with electric actuator and inspection access Blades, front frame and spigot ring made of aluminium Plenum box and cross bar made of galvanised sheet steel Front frame, blades and spigot ring powder- coated RAL 9010, pure white P1: Powder-coated, RAL CLASSIC colour Technical data Nominal sizes: 315, 400, 630, 800 mm Minimum volume flow rate: 175 695 l/s or 630 2502 m³/h Maximum volume flow rate, with L WA 50 db(a): 320 1495 l/s or 1152 5382 m³/h Supply air to room air temperature difference: 10 to +15 K Sizing data [m³/h] Δp t [Pa] Air-regenerated noise L WA [db(a)] Materials and surfaces PD 8

Variants -E* -H -V Variant Ceiling diffuser with circular diffuser face Manual adjustment Nominal sizes 315, 400, 630, 800 Parts and characteristics Top entry spigot Construction features Spigot suitable for circular ducts to EN 1506 or EN 13180 -E* Variant Ceiling diffuser with circular diffuser face Actuator for blade adjustment Nominal sizes 315, 400, 630, 800 Parts and characteristics Top entry spigot Construction features Spigot suitable for circular ducts to EN 1506 or EN 13180 -H Variant Ceiling diffuser with circular diffuser face With plenum box for horizontal duct connection Nominal sizes 315, 400, 630, 800 Parts and characteristics Plenum box for horizontal duct connection Actuator for blade adjustment, optional Variant with actuator has an inspection access at the side Construction features Spigot suitable for circular ducts to EN 1506 or EN 13180 -V Variant Ceiling diffuser with circular diffuser face With plenum box for vertical duct connection Nominal sizes 315, 400, 630, 800 Plenum box for vertical duct connection Actuator for blade adjustment, optional Variant with actuator has an inspection access Construction features Spigot suitable for circular ducts to EN 1506 or EN 13180 Parts and characteristics PD 10

Dimensions and weight ØD H₁ H₂ ØD₁ Nominal size -E* ØD ØD 1 H 1 H 2 m mm mm mm mm kg 315 313 450 122 77 3 400 398 570 139 84 5 630 628 870 184 114 11 800 798 1070 220 135 15 ØD H₁ H₂ ØD₁ -E* Nominal size ØD ØD 1 H 1 H 2 m mm mm mm mm kg 315 313 450 122 158 5 400 398 570 139 166 7 630 628 870 184 196 13 800 798 1070 220 218 18 PD 11

Dimensions and weight -H Q₃ 16 C H₁ A H₃ ØD ØD₁ -H Nominal size ØD ØD 1 H 1 H 3 Q 3 C A m mm mm mm mm mm mm mm kg 315 248 450 122 448 415 45 292 12 400 313 570 139 528 500 45 339 16 630 398 870 184 623 750 45 392 31 800 498 1070 220 745 920 45 464 43 Weights apply to the variant with actuator -V ØD₃ ØD H₁ H₃ C ØD₂ -V Nominal size ØD ØD 1 H 1 A eff H 3 ØD 3 C m mm mm mm m² mm mm mm kg 315 248 450 122 0.0885 305 314 45 8 400 313 570 139 0.1260 411 399 45 12 630 398 870 184 0.2450 486 629 45 22 800 498 1070 220 0.3480 570 799 45 32 Weights apply to the variant with actuator PD 12

Product details Diffuser face Nominal size A eff ØD 1 mm m² 315 450 0.0885 400 570 0.1260 630 870 0.2450 800 1070 0.3480 D₁ PD 13

Installation examples heating mode PD 14

Installation details Installation and commissioning Preferably for rooms with a clear height from 3.8 m Freely suspended and flush ceiling installation Horizontal or vertical duct connection Installation information Installation with spigot ring can be flush with the ceiling or freely suspended Continuous adjustment of the air pattern using an actuator is possible with flush or freely suspended installation Installation and making connections to be performed by others These are only schematic diagrams to illustrate installation details. Ceiling installation without plenum box Ød 1 1 Spigot ring Continuous adjustment of the discharge direction Vertical duct connection Spigot on the rectangular duct is to be provided by others Ceiling installation with plenum box for horizontal duct connection 1 Ød 1 Spigot ring Continuous adjustment of the discharge direction Horizontal duct connection PD 15

Installation details Ceiling cut-out Nominal size 315 398 400 518 630 808 800 1008 Freely suspended installation with plenum box for vertical duct connection Ød mm Continuous adjustment of the discharge direction Horizontal or vertical duct connection PD 16