RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Similar documents
ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

GS2 Series - Introduction

Quick Start Guide of CV50- ControlVIT Series

SYSDrive Frequency Inverter

J1000. Compact Inverter Series.

J1000 D E F I 1000 J1000 J1000 J1000 J1000

MX1S Matrix Converter

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

Delta Products VFD CP2000 Bypass Control Packages.

RVS-DN Digital Reduced Voltage Motor Starter

Description 1/8-7.5HP

RVS-DX Digital Reduced Voltage Motor Starter

Varispeed J7 CIMR-J7AZ. System configuration

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

L300P Inverter Specifications

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

VSD Series II Variable Speed Micro Drives

RVS-AX Instruction Manual

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

VFD E Series. Features

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

HVAC Products. Introducing the SED2 Variable Frequency Drives

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

SJ300 Inverter Specifications

Shenzhen Alpha Inverter Co., Ltd. ALPHA6300V Series Special AC Drive for Tension Control

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

General Specifications

USERS MANUAL MCD REMOTE OPERATOR

MULTI LANGUAGE KEYPAD

Low voltage AC drives

Technical Explanation for Inverters

MaxPak Plus Analog DC V S Drive

AC MOTOR DRIVE for PUMP

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

Regenerative DC Common Bus Supply

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Chapter 1: Getting Started User Manual Overview...1 2

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

Three Phase UPS Systems Range: 10 to 500kVA

Fincor Series 2230 MKII/2240

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

V1000. Inverter Series.

V1000 Inverter Series

PKS-FD Servo System

YASKAWA AC Drive Compact V/f Control Drive J1000

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

KNC-PKS-FD S-AAK-DKH

DORNER Conveyor Speed Control

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

Overvoltage Suppression F7 Drive Software Technical Manual

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

Start-up guide of LSLV-M100

Shenzhen Alpha Inverter Co., Ltd. ALPHA6600 Series AC Drive for Constant Pressure Water Supply System

Variable speed drive or soft starter?

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

KNC-SRV-FD123-CA-000 Series Servo Driver

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

KNC-SRV-FD123-EA-000 Series Servo Driver

Designed for ease of integration with automation systems

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Softstarters Softstarters

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Power Switching Devices

AS THE TIME GOES BY WE HAVE CONSTANTLY MADE QUALITY A TOP PRIORITY

1333 (SERIES B & C) TROUBLESHOOTING GUIDE


SD1 Series General Purpose AC Variable Speed Drives

NX Series. Tuning-Free AC Servo Motor Unit

CTi Automation - Phone: Fax: Web:

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Phone: Fax: Web:

Drives. Section Rev. 1/10. Publications and Reference: See Section 17 for a complete list of additional product-related publications

ADJUSTABLE FREQUENCY CRANE CONTROLS

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

RoHS-Compliant Brushless Motor Systems FBL Series. Features

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

INVERTER FR-A800 Plus

Main Features of Varis

PSE The efficient range Description

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

HPS2DB Serial Softstarter Operation Manual

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Brushless Motors. BMU Series. Connector Type NEW. Easy speed control, easier to use. New connector type with smart wiring.

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

( 0.53~1.6KVA ) 220V 0.2~2.2KW ( 0.53~4.0KVA ) 440V 0.75~2.2KW

High on intelligence big on reliability AC Drive

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

CIMR-V7AZ Varispeed V7

Shenzhen Sine Electric Co., Ltd.

Reduced Voltage Starters Section 2

Technical Information

Transcription:

Features RM6 series are suitable for constant and variable torque loads (mixer, conveyor, fan, pump, etc.) Overload capacity with 150% drive s rated output current for 1 min can sustain heavy load conditions at drive s operation Programmable digital input and output terminals can be defined for various control applications Portable external display units (DM-501) can be connected to display drive statuses (maximum 3 units of DM-501) Programmable 8 preset speeds are suitable for multi-speed control demands Stall prevention functions can prevent the drive from the surge current occurred when the motor accelerates or runs at the constant speed Built-in DC braking function enhances the motor stop completely to prevent unexpected rotations of the motor Programmable jump frequency can prevent the system running at unstable frequency regions Communication control allows portable remote control devices (HMI/PLC/Laptop PC) to operate the drive via RS4 interface Automatic drive restart can start the drive after the power failure Drive Model Number Scheme RM6-2 05 B A B C D A RM6 Product Series B 1: 100V Series - 100~120V 2: 200V Series - 200~240V 4: 400V Series - 380~480V C 05: Rated HP (5HP) D B: Braking Resistor (Built-in Braking Transistor)

Special Features RM6 Communication Control RM6-Stall Prevention Stall prevention function can prevent the motor from sudden load applied causing the stall of the motor speed when the mogrinder Machine tor runs at constant speed or during the acceleration/deceleration. This function can apply to grinder/mixer/sawing machinery to prevent the machine from stalling if the load condition suddenly changes. Sawing Machine RM6 series drives with the communication feature enhances the drive controllability by varieties of remote control schemes. RM6 series drives with RS-4 interface along with ModBus communication protocol are capable of connecting portable remote control device such PLC/HMI/Laptop PC to meet user remote control demands. RM6-Energy Saving Mode Selection RM6 DC Braking DC braking function is to prevent the motor from coasting after the motor stops to ensure the motor completely stops and idle. This function is also to hold the motor from running before drive starts the motor. This function can be applied to crane motor, conveyor, escalator, etc.. Pump Air Conditioning System RM6 energy-saving mode is designed with various V/F curve modes to allow users to select their desire energy-saving mode based on the applications. This function provides intelligent options not only in the motor control but in more energy-saving options based upon the application demands to save the energy. This function can be applied to pump, air conditioning system, fan, or light load applications.

Specifications RM6 100V/200V Series 1 Phase 100V 1Φ 200V 1Φ RM6 Series 1001/2-1PH 1001-1PH 1002-1PH 2001/2-1PH 2001-1PH 2002-1PH Maximum applicable motor (HP/ kw) 0.5/0.4 1/0.5 1.5/1.1 0.5/0.4 1/0.5 2/1.5 Rated output capability (kva) 1 1.6 2.3 1.1 1.9 3 Rated output current (A) 2.5 4.2 6 3 5 8 Rated output voltage (V) Three-phase 200~240V Three-phase 200~240V Single-phase 100~120V 50/60Hz Single-phase 200~240V 50/60Hz Input current (A) 8.8 18 24 13.5 19 Permissible AC power source fluctuation 90~132V 50/60Hz / ±5% 16~264V 50/60Hz / ±5% 150% of drive rated output current for 1 min. 150% of drive rated output current for 1 min. Nature cooling Fan cooling Nature cooling Fan cooling Applicable safety standards UL508C, CSA C22.2 No. 14-05 Protective structure IP20 IP20, UL open type Weight / Mass(kg) 1. 1.8 1.8 1.8 1.9 2 RM6 200V Series 3 Phases RM6 Series (200V, 3Φ) 2020 2025 2030 2040 2050 2060 205 2100 Maximum applicable motor (HP/ kw) 20/15 25/18.5 30/22 40/30 50/3 60/45 5/55 100/5 Rated output capability (kva) 23 28 34 44 55 6 84 112 Rated output current (A) 60 4 90 115 145 15 220 295 Rated output voltage (V) Three-phase 200~240V Three-phase 200~240V 50/60Hz Input current (A) 1 98 110 133 16 200 240 280 Permissible AC power source fluctuation 16~264V 50/60Hz / ±5% 150% of drive rated output current for 1 min. Fan cooling Applicable safety standards UL508C, CSA C22.2 No. 14-05 - Protective structure IP20 IP00 (IP20 OPTION) Weight / Mass(kg) 16 16 16 1 40 41 44 61 RM6 200V Series 3 Phases RM6 Series 200V, 3Φ) 2001/2 2001 2002 2003 2005 200 2010 2015 Maximum applicable motor (HP/ kw) 0.5/0.4 1/0.5 2/1.5 3/2.2 5/3..5/5.5 10/.5 15/11 Rated output capability (kva) 1.1 1.9 3 4.2 6.5 9.5 13 18 Rated output current (A) 3 5 8 11 1 25 33 46 Rated output voltage (V) Three-phase 200~240V Three-phase 200~240V 50/60Hz Input current (A) 5 6 10 14 18 30 40 60 Permissible AC power source fluctuation 16~264V 50/60Hz / ±5% 150% of drive rated output current for 1 min. Nature cooling Fan cooling Applicable safety standards UL508C, CSA C22.2 No.14-05 Protective structure IP20, UL open type Weight / Mass(kg) 1.8 1.8 1.9 2 2.1 5.3 5.4 5. RM6 200V Series 3 Phases RM6 Series (200V, 3Φ) 2125 2150 2200 2250 Maximum applicable motor (HP / kw) 125/90 150/110 200/160 250/200 Rated output capability (kva) 132 154 223 26 Rated output current (A) 346 405 5 00 Rated output voltage (V) Three-phase 200~240V Three-phase 200~240V 50/60Hz Input current (A) 330 380 550 660 Permissible AC power source fluctuation 16~264V 50/60Hz / ±5% 150% of drive rated output current for 1 min. Fan cooling Applicable safety standards - Protective structure IP00 (IP20 OPTION) Weight / Mass(kg) 89 90 164 16

Specifications RM6 General Specifications RM6 400V Series 3 Phases RM6 Series (400V, 3Φ) 4001 4002 4003 4005 400 4010 4015 4020 4025 4030 4040 4050 4060 405 4100 4125 Maximum applicable motor (HP / kw) 1/0.5 2/1.5 3/2.2 5/3..5/5.5 10/.5 15/11 20/15 25/18.5 30/22 40/30 50/3 60/45 5/55 100/5 125/9 0 Rated output capability (kva) 1.9 3 4.6 6.9 11 14 18 23 30 34 46 56 66 84 114 134 Rated output current (A) 2.5 4 6 9 14 18 24 30 39 45 61 3 8 110 150 16 Rated output voltage (V) Three-phase 380~480V Three-phase 380~480V 50/60Hz Input current (A) 3.5 5 8 12 16 22 28 38 50 61 4 90 105 130 155 1 Permissible AC power source fluctuation 332~528V 50/60Hz / ±5% Control characteristics Item User interface Control method Range of frequency setting Resolution of frequency setting Resolution of output frequency Digital operating keypads with remote control and communication link (RS-4 Modbus) Voltage vector sinusoidal PWM control 0.1~400.00 Hz Digital keypad: 0.01 Hz Analog input: 0.06/60 Hz 0.01 Hz Analog voltage of frequency setting DC 0~10 V (20 kω), 4~20 ma (250 Ω) Five steps acc. / dec. times Description 150% drive rated current for 1 minute (inverse time characteristics) 0 second (coast to stop), 0.1~3200.0 seconds (each setting of acc. and dec.) 0.015 ~ 19200000 sec (Acceleration from 0 to 60Hz) Braking torque About 20% (with build-in braking transistor can reach about 100%) 150% of drive rated output current for 1 min V/F curve The V/F curve can be set arbitrarily Nature cooling Fan cooling Stall prevention The current of stall prevention can be set arbitrarily Applicable safety standards UL508C Protective structure IP20, UL open type IP20, UL open type IP20 RM6 400V Series 3 Phases UL508C, CSA C22.2 No.14-05 IP00 (IP20 OPTION) Weight / Mass(kg) 1.8 1.9 2 2 5.3 5.4 5.6 5. 15 16 16 1 18 44 45 4 RM6 Series (400V, 3Φ) 4150 415 4200 4250 4300 4350 4420 4500 4600 Maximum applicable motor (HP / kw) 150/110 15/132 200/160 250/200 300/220 350/250 420/315 500/35 600/450 Rated output capability (kva) 160 193 232 28 316 366 446 533 655 Rated output current (A) 210 253 304 3 415 480 5 00 860 Rated output voltage (V) Three-phase 380~480V Operational characteristics Display Start method Input Multi-function inputs Analog inputs Multi-function outputs Output Analog outputs Keypad display (controller) External display (external connection) Fault Protection Forward (FWD) / reverse (REV) rotation, 3-wire self-holding FWD/REV control, or 9-speed control can be selected Stop command by 3-wire start/stop, jogging operation, secondary acc/dec time, multi-speed command 1~3, reset alarm, external fault command, command of inhibiting output, coast to a stop, max. frequency search command, frequency setting search command, acc/dec inhibition command, UP/DOWN command, UP/DOWN frequency command clear/enter, analog input select, DC braking enable, current limit enable Vin-GND (0~10 V), Iin-GND (4~20 ma / 2~10 V or 0~20 ma / 0~10 V) Running, constant speed, zero speed, frequency, overload, stall prevention, under-voltage, braking detections, restart after fault, fault condition, and instantaneous power interruption to restart detections, programmable a and b ports Analog signal (DC 0~10 V) output, adjustable gain, output frequency selection, frequency setting or output current Frequency output, frequency setting, voltage output, DC bus voltage, current output, motor RPM, linear speed, terminal status Independent external display can be added for up to three sets (96 mm x 48 mm, 5 digits) to show voltage, current, frequency, linear speed, etc. Over-current (OC), over-voltage (OE), low-voltage (LE), motor overload (OL), drive overload (OL1), overheat (OH), fuse open (SC), ground fault (GF), voltage low during running (LE1) Three-phase 380~480V 50/60Hz Diagnostics Digital keypad linking disconnected (Err_00, Err_01), EEPROM error (EEr) Input current (A) 196 21 282 355 3 440 540 650 800 Force air cooling (200V series 1/2, 1HP and 400V series 1HP, 2HP are natural air cooling) Permissible AC power source fluctuation 332~528V 50/60Hz / ±5% 150% of drive rated output current for 1 min. Fan cooling Protections Environment Atmosphere Surrounding temperature Non-corrosive or non-conductive, or non-explosive gas or liquid, and non-dusty -10 C(14 F) ~ +50 C (122 F) non-freezing and non-condensing Applicable safety standards - Storage temperature -20 C (-4 F) ~ +60 C (149 F) Protective structure IP00 (IP20 OPTION) Weight / Mass(kg) 65 91 95 9 159 163 164 21 225 Relative humidity Vibration 90% RH or less (no-condensing atmosphere) Less then 5.9m/sec² (0.6G) Altitude Less then 1000m (3280 ft.)

RM6 Outline Dimensions Fig. 1 Keypad KP-20 65 55 Panel cutting dimension 66 +1 0 55 Fig. 2 RM6(1Φ) - 1001/2 ~ 1002; 2001/2 ~ 2002 RM6(3Φ) - 2001/2 ~ 2005; 4001 ~ 4005 142 2-ψ6 135 128 6.5 46 5.5 Fig. 4 RM6(3Φ) - 2020, 2025, 2030, 2040 RM6(3Φ) - 4025, 4030, 4040, 4050, 4060 9 253 235 11 2-ψ 10 9 116 240 3 25 20 253 235 2-ψ 10 9 238 119 3 25 138 151.5 5.5 2-M4 100 110 128 138 180 162 6 2-6.6 199 9 180 162 8 Supporting frame accessory (Model: A0006804V1.1) 2-6 199 4 69 42 460 42 460 2-M3 95 96 96 +1 0 60 ψ30 48 KP-20 16 23 23x23 23 10 163 4-M 8 235 10 4-M 8 43 25 235 6.5 Panel cutting dim ension 432 Internal cooling type External cooling type Fig. 3 RM6(3Φ) - 200, 2010, 2015 RM6(3Φ) - 400, 4010, 4015, 4020 Fig. 5 RM6(3Φ) - 2050, 2060, 205, 2100, 2125, 2150, 2200, 2250 RM6(3Φ) - 405, 4100, 4125, 4150, 415, 4200, 4250, 4300, 4350, 4420, 4500, 4600 W W1 h1 2-ψd D0 D1 h2 W W1 h1 2-ψd D0 D1 h2 63 2 290 313 329 290 H2 H1 H H2 H1 H 2-35 3-23 4-M5 162 2 2-35 3-23 4-M5 162.5 1 Panel cutting dimension 14.5 20 10 290 313 d ψ15 d 4 4 D2 H1 D2 ψ15 W4 Panel cutting dimension H4 H3 Internal cooling type External cooling type 148 Internal cooling type External cooling type

RM6 200V&400V Outline Dimensions Reference Table RM6-200V Series Applicable RM6 Series Number RM6(3Φ) - 2050, 2060, 205, 2100, 2125, 2150, 2200, 2250 RM6(3Φ) - 405, 4100, 4125, 4150, 415, 4200, 4250, 4300, 4350, 4420, 4500, 4600 RM6-200V Series Dimension (mm) Mounting Hole W W1 W4 H H1 H2 H3 H4 h1 h2 h3 D0 D1 D2 d d1 Ref (mm) 2050 2060 205 386 361 25 365 584 562 539 564 545 11 25 10 325 10 242 10 3 M8 2100 446 418 25 42 6 660 630 662 634 14 30 12 334 12 246 12 3 M10 Fig. 5 2125 508 49 25 48 818 51 88 58 19 35 12 366 183 25 15 3 2150 M12 2200 696 654 580 65 1000 94 929 98 936 15 39 18 405 224 294 15 3 2250 Fault Message Display Fault-Trip Display RM6-400V Series RM6-400V Series Dimension (mm) Mount- W W1 W4 H H1 H2 H3 H4 h1 h2 h3 D0 D1 D2 d d1 Ref (mm) 405 4100 4125 386 361 25 365 584 562 539 564 545 11 25 10 325 10 242 10 3 M8 4150 446 418 25 42 6 660 630 662 634 14 30 12 334 12 246 12 3 M10 415 4200 508 49 25 48 818 51 88 58 19 35 12 366 183 25 15 3 Fig. 5 4250 4300 4350 696 654 580 65 1000 94 929 98 936 15 39 18 405 224 294 15 3 M12 4420 4500 4600 992 954 10 958 1030 1003 963 100 968 15 39 19 419 235 308 15 3 Warning Display

RM6-Accessories Zero-Phase Radio Frequency Filter (RFI-01, 02, 03, 04) Remote Controller KP-20 RFI-01 RFI-02 RFI-01 Dimensions RFI-02 Dimensions 112 98 160 30.5 Remote Controller RAC Series 32 ψ5-2 ψ 130 66 34 3 66 86 5 1.4 180 RAC-01 RFI-03 Dimensions RAC-02 5 RFI-04 Dimensions ψ9-2 R5 ψ9-2 R5 230 154 241 63 44 54 46 2 4 15 3 16 42.3 22.3 130 130 12 26 12 211 54 4 Portable External Display DM-501 42.3 22.3 2 295