Ditec LUXO Swing gates automation (Original instruction)

Similar documents
Ditec BOX Balanced up and over doors

Ditec CUBIC Swing gates automation

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec DOD Industrial sectional door automations

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

Ditec PWR25H/35H Automation for hinged gates

Ditec PWR50H/HV/HR Automation for swing gates

Ditec VALOR Sliding doors automation (Original instructions)

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Ditec SPRINT Swing doors drive unit

IP2160EN. Ditec NeoS / NeoS+ Sliding Gates. Technical Manual. (Original instructions)

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

Entrematic Ditec Sprint 24V

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Ditec SPRINT Automation for swing doors

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

Cross14, Cross14E, Cross14VE, Cross15V

INSTRUCTIONS FOR INSTALLATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Automation Swing Gate Opener

Installation Manual. Swing Gate System. Leading the way...

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

USER INSTRUCTIONS FOR SLIDING DOORS

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

Typical Installation Schematic

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

BULL 424 ESA BULL 624 ESA

Cross Automations for sliding gates

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

EC DECLARATION OF CONFORMITY

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Automatic concealed bollards 275 H600 and 275 H800 Control station

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

FORCE SPD 800/1500/2000

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Automatic concealed bollards 275 H600 and 275 H800 with pit

BISON 20 OM BISON 25 OTI

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

Porte 150 Users Manual Swing Gate Opener 24V DC

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

CE DECLARATION OF MACHINE CONFORMITY

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

E R A I GATE AUTOMATION DIVISION

SLIDE NEW CONTROL BOARD

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

FEATURES AND SPECIFICATIONS

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

FITTING AND CONNECTION INSTRUCTIONS

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

BARRY BARRIER GATE AUTOMATION

SWING GATE OPENERS 24V DC GEAR MOTOR

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

ARACHNE 230V 24V- 12V

Ditec PWR Automation system for swing gates with wings up to 5 metres

IMPORTANT NOTICE FOR THE INSTALLER

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

OBBI3BH. Manuale di installazione e manutenzione per automazioni per cancelli a battente. Installation and Maintenance manual for swing gates.

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

Automation for gates and automatic barriers.

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

HYDRAULIC SWING GATE OPENER

GB Instructions Manual

1 GENERAL SAFETY PRECAUTIONS

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

TITANO 400V SLIDING GATE OPENER

ASW-400. Installation Manual. Downee

BELT CONVEYOR CB/M5 Series

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

BELT CONVEYOR PNL/4 Series User and maintenance manual

Everything becomes automatically more convenient! Discover the Ditec automation

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

Mod: KLD6-12/35XLAS-N

Transcription:

Ditec LUXO Swing gates automation (Original instruction) IP2128EN Technical manual www.ditecentrematic.com

Index Subject Page 1. General safety precautions 21 2. Declaration of incorporation of partly completed machinery 22 2.1 Machinery Directive 22 2.2 Operating instructions 22 3. Technical specifications 23 4. Standard installation 24 5. Dimensions and references 25 6. Installation 26 6.1 Preliminary checks 26 6.2 Bracket fastening 27 6.3 Geared motor installation 28 6.4 Reversible and irreversible piston 29 7. Electrical connections 30 8. Ordinary maintenance program 30 User instructions 31 Manual release instruction 32 Caption i This symbol indicates instructions or notes regarding safety, to which special attention must be paid. This symbol indicates useful information for the correct functioning of the product. 20

1. General safety precautions This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of danger. Before installing the product, make sure it is in perfect condition. Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard. Before installing the motorisation device, make all the necessary structural modifications in order to create safety clearance and to guard or isolate all the crushing, shearing, trapping and general hazardous areas. Make sure the existing structure is up to standard in terms of strength and stability. The motorisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised or for any deformation during use. The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorised door. The safety devices must protect the crushing, cutting, trapping and general hazardous areas of the motorised door. Display the signs required by law to identify hazardous areas. Each installation must bear a visible indication of the data identifying the motorised door. When requested, connect the motorised door to an effective earthing system that complies with current safety standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts. The automation protection casing must be removed by qualified personnel only. The electronic parts must be handled using earthed antistatic conductive arms. The manufacturer of the motorisation declines all responsibility in the event of component parts being fitted that are not compatible with the safe and correct operation. Use original spare parts only for repairs or replacements of products. The installer must supply all information on automatic, manual and emergency operation of the motorised door and must provide the user with the operating instructions. 21

2. Declaration of incorporation of partly completed machinery (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden, declares that the automation for Ditec LUXO type swing gate: - has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC. The manufacturer of the motorised door shall declare conformity pursuant to the Directive 2006/42/EC (Annex II-A), prior to the machine being put into service; - conforms to the applicable essential safety requirements indicated in ANNEX I, Chapter 1 of the Directive 2006/42/EC; - conforms to the Low Voltage Directive 2006/95/EC; - conforms to the Electromagnetic Compatibility Directive 2004/108/EC: - the technical documentation conforms to Annex VII-B of the Directive 2006/42/EC; - the technical documentation is managed by Marco Pietro Zini with headquarters in Via Mons. Banfi, 3-21042 Caronno Pertusella (VA) - ITALY; - a copy of technical documentation will be provided to national competent authorities, following a suitably justified request. Landskrona, 06-05-2013 Marco Pietro Zini (President) 2.1 Machinery Directive Pursuant to Machinery Directive (2006/42/EC) the installer who motorises a door or gate has the same obligations as the manufacturer of machinery and as such must: - prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the motorised door); - draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Directive and deliver it to the customer; - affix the EC marking on the motorised door in accordance with point 1.7.3 of Annex I of the Machine Directive. 2.2 Operating instructions Service class: 4 (minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years) Use: INTENSIVE (For vehicle or pedestrian accesses to large condominiums, industrial or commercial complexes and parking lots with very frequent use). - Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible weight). When used with the maximum permissible weight a reduction in the above mentioned performance can be expected. - Service class, running times, and the number of consecutive cycles are to be taken as merely indicative Having been statistically determined under average operating conditions, and are therefore not necessarily applicable to specifi c conditions of use. - Each automatic entrance has variable elements such as: friction, balancing and environmental factors, all of which may substantially alter the performance characteristics of the automatic entrance or curtail its working life or parts thereof (including the automatic devices themselves). The installer should adopt suitable safety conditions for each particular installation. 22

3. Technical specifications LUXO3BH LUXO4BH Power supply 24 V 24 V 24 V Absorption 4 A 4 A 12 A Thrust 2000 N 2000 N 3000 N Max run 350 mm 500 mm 500 mm Opening time 20 50 s / 90 30 60 s / 90 20 45 s / 90 LUXO5BH LUXO5VBH Service class 4 - INTENSIVE 4 - INTENSIVE 4 - INTENSIVE Intermittence S2 = 20 min S3 = 50% S2 = 20 min S3 = 50% S2 = 20 min S3 = 50% Temperature min -20 C max +55 C min -20 C max +55 C min -20 C max +55 C Degree of protection IP24D IP24D IP24D Control panel E2HLX - VIVAH E2HLX - VIVAH VIVAH Applications m = leaf width kg = leaf weight 500 kg 400 kg 500 kg 400 kg 500 kg 400 kg Limit dimensions 300 kg 200 kg 300 kg 200 kg 300 kg 200 kg Recommended dimensions 100 kg 1 2 3 4 5 m 100 kg 1 2 3 4 5 m 100 kg 1 2 3 4 5 m LUXO3B LUXO5B Power supply 230 V~ 50 Hz 230 V~ 50 Hz Absorption 1.1 A 1.1 A Thrust 3000 N 3000 N Max run 350 mm 500 mm Opening time 22 s / 90 32 s / 90 Service class 4 - INTENSIVE 4 - INTENSIVE Intermittence S2 = 20 min S2 = 20 min S3 = 50% S3 = 50% Temperature min -20 C max +55 C min -20 C max +55 C Degree of protection IP24D IP24D Control panel E2 - LOGICM E2 - LOGICM Applications m = leaf width kg = leaf weight 500 kg 400 kg 500 kg 400 kg Limit dimensions 300 kg 200 kg 300 kg 200 kg Recommended dimensions 100 kg 1 2 3 4 5 m 100 kg 1 2 3 4 5 m 23

4. Standard installation 2 3 8 RX - 4x0.5 mm² 5 7 7 2x1.5 mm² 4x0.5 mm² TX - 4x0.5 mm² 5 3x1.5 mm² 6 6 7 7 TX - 4x0.5 mm² RX - 4x0.5 mm² 4 2x1.5 mm² A 1 Ref. Code Description 1 GOL4 Transmitter 2 LAMPH Flashing light 3 XEL5 GOL4M Key selector Codified via radio control keyboard 4 LAB9 Magnetic loop detection device for traffic monitoring LUXO3B AC reversible and irreversible actuator for door wing of up to 3.5 m LUXO3BH DC irreversible actuator for door wing of up to 3.5 m 5 LUXO4BH DC irreversible actuator for door wing of up to 4 m LUXO5B AC reversible and irreversible actuator for door wing of up to 5 m LUXO5BH DC irreversible actuator for door wing of up to 5 m LUXO5VBH DC irreversible actuator for door wing of up to 5 m with limit switch LUXO3B LUXO5B Cable 4x1,5 mm² 6 LUXO3BH LUXO4BH Cable 2x1,5 mm² LUXO5BH LUXO5VBH 7 XEL2 LAB4 Photocells Photocells IP55 8 Control panel A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least 3mm (not supplied). The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices. 24

5. Dimensions and references 9 10 F G 12 16 11 13 Ref. Code Description 9 Cover 10 Lock flap 11 Release lock 12 Drive screw cover 13 Drive screw 14 Tail bracket 15 Head bracket 16 LUXOFCH Limit switch (only standard on LUXO5VBH) F Cover fastening screw G Drive cover fastening screw S LUXO3B-5B LUXO3BH LUXO4BH LUXO5BH LUXO5VBH 120 68 78 100 S = 890 [LUXO3B-3BH] 1040 [LUXO4BH-5B-5BH-5VBH] R 66 R = max 350 [LUXO3B-3BH] max 500 [LUXO4BH-5B-5BH-5VBH] 66 25

6. Installation The given operating and performance features can only be guaranteed with the use of ENTREMATIC accessories and safety devices. Unless otherwise specified, all measurements are expressed in mm. 6.1 Preliminary checks Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated. Provide an opening and closing stop. Position tail bracket [14] on to the pillar to check installation measurements and secure it. The installation measurements indicated in the table allow you to choose the values of [A] and [B] on the basis of the desired opening angle and in relation to the on site spaces and overall dimensions. NOTE: The measurements [A] and [B] must be the same, in order to have a regular moviment. Increasing [A] decreases the coming up speed during opening. Reducing [B] increases the extent of gate opening. Measurements [A] and [B] must in any case be compatible with the useful travel of the piston so that; if [A] is increased, [B] must be decreased and vice versa. A E C B L min 60 D [*] Use measurements between minimum and maximum values LUXO3B LUXO3BH LUXO4BH LUXO5B LUXO5BH LUXO5VBH A* B* A B C D E L 130 170 100 90 min 105 min 130 105 140 70 90 max 160 max 170 130 130 60 95 90 760 160 130 50 110 170 170 100 90 min 130 min 170 200 200 130 95 max 200 max 290 200 170 100 120 120 910 130 290 220 90 26

6.2 Bracket fastening - Once you have fastened the tail bracket [14] following the measurements indicated on page 26, fasten the head bracket [15] to the gate. NOTE: shorten the tail bracket [14] by following the instructions on page 26. - When the gate is completely closed, place the head bracket [15] near the piston attachment complying with measurements [E] and [L]. Make sure that the head brackets [15] and tail brackets [14] are perfectly level as shown in the following figures and fasten the head bracket [15] to the gate. LUXO3BH Ø9 70 152 72 50 14 32 38 70 Ø9 100 15 112 90 Ø14 82 (B - C) 112 (B - C) 142 (B - C) L Ø18 90 LUXO3B-LUXO4BH-LUXO5B-LUXO5BH-LUXO5VBH B - C 14 E 90 15 6 Ø9 90 6 14 80 Ø9 60 80 115 60 15 20 115 115 50 10 15 165 Ø14 180 L 10 31 (*42) 50 * LUXO5VBH Ø18 (*22) 135 27

6.3 Geared motor installation - Open the lock flap [10] unscrew the screw [F] and remove the cover [9]. Unscrew the screw [G] and remove the drive screw cover [12] as shown in the figure on pag. 7. Release the piston (see operating instructions). - Mount the piston on tail [14] and head bracket [15], tightly screwing down the self-locking nut and lubricate the turning points. NOTE: pay special attention to the correct assembly of the washer on the head bracket. LUXO3BH 14 LUXO3B LUXO4BH LUXO5B LUXO5BH LUXO5VBH 14 - Fit and secure the drive screw cover [12] on the drive screw [13] by means of the screws provided [G]. NOTE: ensure that the drive screw [13] is properly inserted onto the screw cover head [12] (see figure). - Move the gate by hand and check for smooth and free movement throughout. LUXO3BH LUXO3B LUXO4BH LUXO5B LUXO5BH LUXO5VBH 13 12 13 13 15 28

6.4 Reversible and irreversible piston (only LUXO5BH and LU- XO5VBH) To make the piston reversible, insert pin [M]. NOTE: the operation must be carried out with the piston moving. Removing the pin [M], the piston becomes irreversible, and the release can only be made with the key (see operating instructions). M M 29

7. Electrical connections Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply. Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout. The gearmotors LUXO3B and LUXO5B can be connected to the E2 and LOGICM control panels. The gearmotors LUXO3BH and LUXO4BH can be connected to the E2HLX and VIVAH control panels. The gearmotors LUXO5BH and LUXO5VBH can be connected to the VIVAH control panel. The electrical wiring and the start-up of the gearmotors LUXO are shown in figure and in the installation manuals of the E2, LOGICM, E2HLX and VIVAH control panels. To increase the protection of the motor cable, a flexible Ø16 raceway [N] may be used and the associated Ø20 union [P], not supplied by us. Tighten the screw [F]. 8. Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation. Disconnect the 230 V~ power supply and batteries if present: - Clean and lubricate, using neutral grease, the turning pins, the hinges of the gate and the drive screw - Check that fastening points are properly tightened. - Check the electrical wiring is in good condition. Reconnect the 230 V~ power supply and batteries if present: - Check the power adjustments. - Check the good operation of all command and safety functions (photocells). - Check the good operation of the release. - If present, check for battery continuity by powering off and performing several manoeuvres in sequence. Upon test completion, power back on (230 V~). i NOTE: For spare parts, see the spares price list. 30

Operating instructions General safety precautions DETACH AND DELIVER TO THE CUSTOMER These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use. This product must not be used by people (including children) with reduced physical, sensorial or mental abilities, or lack of experience or knowledge, unless they are given proper surveillance and instructions for operating the device by a person responsible for their safety. Avoid operating in the proximity of the hinges or moving mechanical parts. Do not enter within the operating range of the motorised door while it is moving. Do not block the movement of the motorised door since this may be dangerous. Do not allow children to play or stay within the operating range of the motorised door. Keep remote controls and/or any other control devices out of the reach of children in order to avoid possible involuntary activation of the motorised door. In the event of a fault or a malfunction of the product, turn off the power supply switch, do not attempt to repair or intervene directly and contact only qualified personnel. Failure to comply with the above may cause a dangerous situation. All cleaning, maintenance or repair work must be carried out by qualified personnel. To ensure that the system works efficiently and correctly, the manufacturer s indications must be complied with and only qualified personnel must see to the routine maintenance of the motorised gate. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. To dispose of electrical and electronic equipment as well as batteries correctly, users must take them to special recycling centres provided by the municipal authorities. 31

Manual release instructions In the event of a fault or blackout, insert the key and turn it clockwise. Unlock the electric lock, if mounted. Manually slide the gate open. To relock the wings, turn the key anticlockwise. WARNING: the door wing block and release operations must be performed with the motor idle. For any problems and/or information, contact the support service. Installer's stamp Operator Date of intervention Technician's signature Customer's signature DETACH AND DELIVER TO THE CUSTOMER Intervention performed Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.com 32

All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication. We reserve the right to make changes without prior notice. Copying, scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB. 33

Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.com