TECHNICAL DATA HYDRAULIC UNIT

Similar documents
INSPECTIONS AND MAINTENANCE

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Oil-hydraulic operator for swinging gates

INSTALLATION MANUAL GB

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

CHECKING AND MAINTENANCE:

DRIVE 700 OVERALL DIMENSIONS

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

GB INSTALLATION MANUAL

GB Instructions Manual

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox

INSTALLATION MANUAL (cod )

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

a p prove d ELECTROMECHANICAL SLIDING GATE OPENER

Automatic concealed bollards 275 H600 and 275 H800 with pit

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

INSTRUCTIONS FOR INSTALLATION

SLIDE NEW CONTROL BOARD

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

BISON 20 OM BISON 25 OTI

E R A I GATE AUTOMATION DIVISION

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

TITANO 400V SLIDING GATE OPENER

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

SWING GATE OPENERS 24V DC GEAR MOTOR

EC DECLARATION OF CONFORMITY

SWING GATE OPENERS 24V DC GEAR MOTOR

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Automatic concealed bollards 275 H600 and 275 H800 Control station

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

IMPORTANT NOTICE FOR THE INSTALLER

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

VER KIT. Installation Instructions TECHNICAL HELPLINE

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

ELECTRONIC CONTROL PANEL FOR ONE 230VAC MOTOR TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Typical Installation Schematic

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

Instruction Manual for the. E-SL 450 Series

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

ELSEMA 240VAC Slider Control Board, SLD

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Automation Swing Gate Opener

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

Automatic hidden traffic bollards 275 H600 and 275 H800 with pit

SWING GATE OPENER SW300 SERIES

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

BULL 424 ESA BULL 624 ESA

Installation Manual. Swing Gate System. Leading the way...

FITTING AND CONNECTION INSTRUCTIONS

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Automation systems for swing gates hydraulic

E R A I INSTALLATION MANUAL. Gate Opener Department MERCURIO 302 F MERCURIO 502 F MERCURIO 802 F MERCURIO 501 F

MBM8 / MBM11- Barriers. Installer and User s manual

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

FORCE SPD 800/1500/2000

FEATURES AND SPECIFICATIONS

CE DECLARATION OF MACHINE CONFORMITY

E R A I Gate Automation Division

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

CAUTION CM-SE CM-S21 CM-S41

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

access

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

Installation Manual 820/860. Sliding Gate System. Leading the way...

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

PY600AC Sliding Gate Opener User Manual

V. 003 QUESTO LIBRETTO È DESTINATO SOLO ALL'INSTALLATORE.

VERG 24V BARRIER. English

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

UNIK2E _ V2 (COMPLETE) UNIK2ESK _ V2 (WITHOUT BOX AND TRANSFORMER)

BARRY BARRIER GATE AUTOMATION

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Sliding Gate Operator User's Manual

GL1200T Cut & Seal. (GL1200 Seal only)

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Transcription:

GB INSTRUCTIONS MANUAL

RISING BOLLARD OIL-HYDRAULIC AUTOMATION COMPONENTS strabuc 918 RELEASE KEY PLUG FOR RELEASE HOLE BOLLARD COVER 12 V WARNING LIGHTS REFLECTORS COMPLETELY RETRACTABLE POST WITH ELECTROPHORESIS ANTI- CORROSION TREATMENT 4 SCREWS FOR FIXING THE POST TO THE ANCHORAGE FLANGE SUPPORT FLANGE WELDED TO THE CONTAINMENT CYLINDER FIXING FLANGE WITH BRACKETS TO BE SET IN CONCRETE AT 1 cm BELOW THE WITH ELECTROPHORESIS ANTI-CORROSION TREATMENT CONTAINMENT CYLINDER IN ELECTROPHORESIS ANTI-CORROSION TREATED STEEL INTERNAL OIL-HYDRAULIC UNIT 3 WATER DRAINAGE AND WIRING HOLES ELECTRIC CABLES WITH EARTH CONNECTION 24 V LIMIT SWITCH CABLE ELECTRIC MOTOR CABLE 2 230 V TRANSFORMER CABLE FOR WARNING LIGHTS

AUTOMATION INSTALLATION INSTRUCTIONS FOR THE STRABUC 918 TO BE INSTALLED AND OPERATE CORRECTLY, WE RECOMMEND TO FOLLOW THE INSTRUCTIONS AND RELATIVE ILLUSTRATIONS BELOW. The Strabuc 918 is an oil-hydraulic traffic bollard which retracts completely down to the level of the road surface. It is designed to prevent vehicles from passing, but can also be completely retracted without leaving the slightest trace. It is an oil-hydraulic automation with an incorporated internal hydraulic unit, while its control programmer, Elpro 10 CEI is installed externally, in a sheltered area. In order to install the Strabuc 918, it is necessary to dig a containment hole and lay an underground conduit for the electric cables. INSTALLATION OF THE FIXING FLANGE AND THE CONCRETE CONTAINMENT SLEEVE - Dig a hole so as to insert a concrete tube beneath the road following the measurements shown in Pic. 1 (make sure that the hole does not cut into the water table or damage other pipes). You should also dig a lateral hole for the insertion of a conduit for the electric cables to be connected to the electronic programmer (to be installed in a dry place). - The concrete sleeve should enable rainwater to drain away through the base, we therefore recommend gravel foundations. - The fixing flange should be cemented into position at 1 cm beneath the road surface (Pic. 2), above the concrete sleeve, so as to allow the Strabuc 918 rising bollard installed inside the concrete sleeve to be on a level with the road surface when re-entering the containment cylinder. FIXING FLANGE WITH BRACKETS CEMENTED 1 cm BENEATH THE 1.10 metres CONCRETE SLEEVE FOR HOUSING THE STRABUC 918 INTERNAL DIAMETER 40 cm ELECTRIC CABLE CONDUIT CONNECTED TO THE CONCRETE SLEEVE FOUNDATION GRAVEL FOR WATER DRAINAGE PIC. 1 WATER DRAINAGE PIPES CROSS-SECTION OF STRABUC 918 INSTALLATION 1 cm FIXING FLANGE WITH CEMENTED BRACKETS STRABUC 918 INSTALLED WITH BOLLARD LOWERED TO LEVEL CONCRETE SLEEVE PIC. 2 CROSS-SECTION OF CONCRETE SLEEVE WITH STRABUC 918 INSTALLED 3

PLACING THE STRABUC 918 INTO THE CONCRETE SLEEVE AND PASSING THE ELECTRIC CABLES THROUGH THE CONDUIT Once the fixing flange has been cemented into position, the Strabuc 918 can be placed into the cement sleeve as it is already ready for use. - Open the rising bollard cover by unscrewing the three screws (Pic. 3), thereby uncovering the top of the rising bollard. - Attach a winch to the Strabuc 918 lifting hook and lift the entire bollard, positioning it above the concrete sleeve (Pic. 4) - Place the electrical cables inside the conduit, letting them rest freely on the conduit floor (Pic. 4) - Place the Strabuc 918 inside the concrete sleeve, accompanying the electrical cables at the same time without tugging or cutting them. - Attach the Strabuc 918 to the fixing flange using the four fixture screws - Close the rising bollard cover, screwing the three screws into place. WARNING: After the installation has been completed, there should be at least 30 cm of space between the hole foundation and the bottom of the Strabuc 918 bollard (Pic. 4). 1 REMOVE THE COVER BY UNSCREWING THE 3 SCREWS BOLLARD COVER FIXING SCREWS BOLLARD COVER LIFTING HOOK PIC. 3 FIXING SCREWS 2 USE A WINCH TO INSERT THE AUTOMATION, HOOKING IT TO THE SPECIFIC LIFTING HOOK IMPORTANT: WHILE LIFTING THE BOLLARD, BE CAREFUL NOT TO PULL OR SQUASH THE ELECTRIC CABLES IMPORTANT: 3 INSERT THE ELECTRIC CABLES CONNECTING THE BOLLARD TO THE ELECTRONIC PROGRAMMER INTO THE CONDUIT, LETTING THEM LAY ON THE BASE WITHOUT SHORTENING THEM 4 SCREW THE 4 FIXING SCREWS INTO THE FIXING FLANCE WHICH HAS ALREADY BEEN CEMENTED INTO PLACE AT 1 CM BENEATH THE 5 REPLACE THE COVER AND SCREW THE SCREWS BACK IN CONDUIT FOR ELECTRIC CABLES CONNECTING THE BOLLARD TO THE ELPRO 10 CEI ELECTRONIC PROGRAMMER 30 cm PIC. 4 4 STRABUC 918 INSERTION INTO THE CONCRETE SLEEVE

ELECTRICAL CONNECTIONS TO ELPRO 10 CEI PROGRAMMER ALL CONNECTIONS INSIDE THE STRABUC 918 BOLLARD (ELECTRIC MOTOR, LIMIT SWITCH AND WARNING LIGHTS) HAVE ALREADY BEEN MADE. IMPORTANT: all the electrical connections and wiring (Pic. 5) must respect good installation practice and be installed professionally by qualified personnel, in compliance with the current Machinery Directive 98/37/EC safety standards, carrying out a complete risk analysis and adopting suitable safety measures. - The Elpro 10 CEI programmer should be installed in a dry, sheltered place. - The Elpro 10 CEI programmer should be powered by electric wires with a section of 1.5 mm 2, for a maximum distance of 50 metres. For distances of over 50 metres, we recommend using electric wires with a section of 2 mm 2. - Electric wires with a section of 1 mm 2 can be used to power photocells, pushbuttons, keyswitches and accessories. IMPORTANT: before connecting the electricity supply, switch the voltage change switch to 230 V (Pic. 8). 1 2 x 1 mm 2 RGB wire 8 2 4 4 x 1 mm 2 3 4 x 1 mm 2 2 x 1 mm 2 5 9 6 3 2 x 1 mm 2 7 4 x 1 mm 2 8 PIC. 5 10 ELECTRICAL CONNECTIONS DIAGRAM ELECTRIC SYSTEM COMPONENTS: 1 Miri 4 flashing light with incorporated antenna 2 Prit 19 keyswitches 3 Polo 44 photocell transmitter 4 Astro 43 plug-in card 5 Elpro 10 CEI electronic programmer 6 Electric cable shunt box 7 Differential magneto-thermal mains switch 8 Polo 44 photocell receiver 9 Strabuc 918 rising bollard 10 Small Astro 43 remote control 5

RELEASE OPERATION FOR MANUALLY LOWERING THE BOLLARD This operation is generally referred to as the Manual Release operation and involves manually lowering the rising bollard by using a specially moulded key if the Strabuc 918 s power supply happens to be cut off. Warning: This operation only enables the bollard to be lowered and cannot be used to make it rise. 1 - Use a hexagonal key to unscrew the protective plug placed in the bollard cover (Pic. 6) 2 - Insert the release key into the lock inside the bollard cover hole 3 - Turn the release key anti-clockwise, thus making the bollard slowly descend to ground level. RELEASE KEY PROTECTIVE PLUG BOLLARD COVER RISING BOLLARD DESCRIPTION OF ELECTRICAL WIRING CONNECTIONS IN THE STRABUC 918 The Strabuc 918 comes supplied with three electric cables, 10 metres long: a 230 V 50 Hz power supply cable, an electrical limit switch cable and an electrical transformer cable for the warning lights. The connections are only made to the Elpro 10 CEI programmer as illustrated in diagrams in Pic. 7 and Pic. 8. PIC. 6 ALL STRABUC 918 CABLES CAN BE IDENTIFIED BY THEIR IDENTIFICATION LABELS. ELECTRIC MOTOR CABLE LIVE BLACK - LIVE BROWN - NEUTRAL BLUE - EARTH - YELLOW/GREEN - 12µF WARNING LIGHTS TRANSFORMER CABLE LIVE 230 V - BROWN - IN THE CASE OF LACKING IMPETUS ADD A 12µF CAPACITATOR NEUTRAL BLUE - EARTH - YELLOW/GREEN - ELECTRIC CABLE CONDUIT TO BE INSTALLED UNDERGROUND (PIC. 4) LIMIT SWITCH CABLE OPEN LIMIT SWITCH - BLACK - NEUTRAL BLUE - IMPORTANT: IF THE RISING BOLLARD DOES NOT RISE ONCE ALL THE CONNECTIONS HAVE BEEN MADE, INVERT THE LIMIT SWITCHES OPEN AND CLOSE CLOSE LIMIT SWITCH - BROWN - PIC. 7 6

26 27 28 TERMINALS FOR THE CONNECTION OF THE PUSH BUTTONS PULIN 3 VOLTAGE CHANGE-OVER SWITCH 400 V 230 V 10 CEI ON PIC. 8 DIP-SWITCH B 1 2 3 4 ON - PHOTOCELLS OFF DURING OPENING ON - REMOTE CONTROL DOES NOT INVERT ON - CLOSES AUTOMATICALLY ON - WITHOUT PRE-FLASHING 24 V OUTPUT 1 CHANNEL RADIO CONTROL PLUG-IN CARD SUPPORT ON N.B: for inverse operations, turn the DIP-SWITCH levers to the OFF position. OFF 3 7 FADINI POWERED CARD 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 16 17 18 19 20 21 22 23 N.C. CONTACT. PHOTOCELLS ALL OPERATIONS OPEN, CLOSE & REVERSE RADIO CONTACT MICROPROCESSOR COMMON. PUSH BUTTONS & INDICATOR 1 AMP. FUSE: 24 V OUTPUT TERMINALS 12-13 N.O. CONTACT. OPEN N.O. CONTACT. CLOSE N.C. CONTACT. STOP DESCRIPTION OF INDIVIDUAL GATE ELECTRONIC PROGRAMMER OPERATION FOR SLIDING GATES Make sure that all the electrical connections comply with the diagram enclosed. Once terminals 21, 22 and 23 are supplied with single-phase 230 V 50 Hz power, the red LED No. 1 should light up, indicating that the card is powered. The OPEN and CLOSE operation timer should be greater than the gate stroke. The PAUSE timer should be adjusted to fit requirements. PROGRAMMER OPERATION LOGIC: following impulse, the warning light comes on and the automation comes into operation after three seconds. The warning light continues to flash during the pause; the flashing light functions for a further three seconds when the gate is closed. In order to deactivate the flashing light before opening (pre-flashing), use DIP-SWITCH B position 4. SETTING DIP-SWITCH B SIGNAL LEDs: LED No. 1: lights up when the card is powered. LED No. 2: Photocells normally lit up. Only switches off when an obstacle is placed between the photocells. LED No. 3: Open, lights up when the relative button is pressed. LED No. 4: Close, lights up when the relative button is pressed. LED No. 5: Stop normally lit up. Switches off if the relative button is pressed. LED No. 6: Closure limit switches off when the gate is completely closed. LED No. 7: Open limit switches off when the gate is completely open. LED No. 8: Radio lights up whenever an impulse is received from the remote control or pushbuttons. RADIO CONTACT. N.O. LIMIT SWITCH. CLOSE. N.C. LIMIT SWITCH. COMMON PEDESTRIAN OPENING CARD CONNECTOR LIMIT SWITCH. OPEN. N.C. 24 V - 3 W max. INDICATOR Should more pairs of photocells be required than the recommended quantity, fit an auxiliary transformer outside the control box. 24 Vac OUTPUT Max. permitted load: 2 pairs photocells 1 radio receiver DWELL TIME CONNECTION WARNINGS: 1) The programmer should be installed in a dry, sheltered place. If it is installed outside, it will require a protective box to protect it from the elements. 2) The whole system should be earthed. 3) If the photocells are not used, create a bridge between terminals 1 and 2. 4) In order to install two pairs of photocells the connections should be made in series with the 1 2 contact normally closed; if installed one next to the other they should be crossed in pairs i.e. transmitter next to the receiver of the next pair. 5) If no pushbuttons are used, create a bridge between terminals 3 and 6. 6) Before the programmer, apply a high-sensitivity 0.03 Amp differential magneto-thermal switch. 7) For single-phase motors use cables of at least 1.5 mm 2. 8) The 24 V~ output to terminals 12 13 is able to power 2 pairs of photocells plus 1 radio receiver. An auxiliary transformer placed outside the programmer should be used in the case of more than two pairs of photocells or more radio receivers. 9) Terminal No. 11 indicator light output is able to cater for max. 24 V 3 W bulb; terminals No. 19-20 flashing light output maximum absolute power 25 W. PP MOTOR RUN TIME OPEN & CLOSE CUT OFF SWITCH BY COVER KNOB COMMON M SINGLE-PHASE ELECTRIC MOTOR M THREE-PHASE ELECTRIC MOTOR 230 V - 25 W max. FLASHING LAMP NEUTRAL OPEN CLOSE PHASE LIVE NEUTRAL SUPPLY VOLTAGE 230 V SINGLE-PHASE 21 22 23 SUPPLY VOLTAGE 230-400 V THREE-PHASE LINE 630 ma FUSE FLASHING LAMP 5 A FUSE HIGH VOLTAGE N. W.: for special applications, ie. to switch on lights - CCTV etc, SOLID STATE RELAYS are recommended to be used only. Standard relays would affect the micro-processor. ON EARTH DIP-SWITCH B 1 2 3 4 630 ma FUSE LOGIC N.W.: THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH FADINI ACCESSORIES. NO GUARANTEE FOR ACCESSORIES OF OTHER MAKE OR SPECIAL APPLICATIONS. ON OFF 1 - ON: PHOTOCELLS OFF DURING OPENING OFF: PHOTOCELLS INVERT MOTION DURING OPENING 2 - ON: REMOTE CONTROL DOES NOT INVERT OFF: REMOTE CONTROL INVERTS 3 - ON: AUTOMATIC CLOSURE OFF: SEMIAUTOMATIC CLOSURE 4 - ON: WITHOUT PRE-FLASHING OFF: WITH PRE-FLASHING 7

TECHNICAL DATA HYDRAULIC UNIT Hydraulic pump...p10 Hydraulic pump capacity...4.45 l/min. Average working pressure...2 MPa (20 bar) Maximum supplied pump pressure...4 MPa (40 bar) Working temperature... 20 C +80 C Hydraulic oil type...oil FADINI A15 by AGIP Static weight of the pump assembly...10 Kg Protection standards...ip 54 OIL-HYDRAULIC PISTON Piston stroke time...6 sec. Useful piston stroke...740 mm Rod diameter...16 mm Piston diameter....30 mm Max. traction force during opening...276 Kg Max. thrust during closure...147 Kg STRABUC 918 total weight...128 Kg Full protection standards...ip 557 Flashing light power supply...230 V - 25 W ELECTRIC MOTOR Power yielded...0.25 KW (0.33 HP) Power supply voltage / Frequency...230 V - 50 Hz Absorbed current...1.8 A Absorbed power...330 W Capacitor....12.5 µf Motor rotation speed...2 800 revs/min. Duty mode...s 3 PERFORMANCE Duty cycle...6 s Opening - 30 s Pause - 6 s Closing Complete cycle time...42 seconds Complete Opening Pause Closing cycles...85/hour Annual cycles (with 8 hours of use per day)...nr. 250 000 INSPECTIONS AND MAINTENANCE In order to ensure optimal system performance over time and so as to comply with current safety standards, it is necessary to follow the correct maintenance and monitoring procedures for the entire automation, electronic devices and wiring: - Oil-hydraulic automation: maintenance inspection around every 6 months - Electronic devices and safety systems: maintenance inspection monthly. Ø25 Ø 425 Ø 425 thickness 10 mm Ø 325 thickness 6 mm Ø100 Ø 275 thickness 4 mm 10 10 metres 700 920 1 620 Lineagrafica 10-2003 WARNINGS - Perform a Risk Analysis before every installation and resolve risks through the use of safety devices in compliance with EN 12445 and EN 12453 safety standards - Follow the instructions provided - Check that the information on the electric motor plate conforms to the distribution network - Dispose of all cardboard, nylon, polystyrene and other packaging with specialized waste disposal firms - If removing the actuator, do not cut the electric wires, but disconnect them from the terminal box by loosening the screws inside the shunt box - Disconnect the mains switch before opening the electrical wire shunt box cover - The whole automation should be earthed with the yellow/green wire - CUSTOMER GUARANTEE CERTIFICATE ON CUSTOMER S REQUEST. We recommend reading the warning regulations, suggestions and observations in this booklet very carefully. The CE mark certifies that the operator conforms to the essential requirements of the European Directive art. 10 EEC 73/23, in relation to the manufacturer s declaration for the supplied items, in compliance with the body of the regulations ISO 9000= UNI EN 29000. Automation in conformity to EN 12453, EN 12445 safety standard. EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98/37/EC DECLARATION OF CONFORMITY GENERAL WARNINGS EN 12453, EN 12445 STANDARDS CEI EN 60204-1 STANDARDS WARRANTY CERTIFICATE ON THE CUSTOMER S REQUEST The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards, updated knowledge of the European Standards and compliance with their requirements, in view of an ever increasing process of improvement. Made in Italy s.n.c. Distributor s box AUTOMATIC GATE MANUFACTURERS The manufacturers reserve the right to change the products without any previous notice Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. 0442 330422 r.a. - Fax 0442 331054 - e-mail: info@fadini.net - www.fadini.net