RPP Medium range pressure switches

Similar documents
RD Differential pressure switches

RD Standard differential pressure switches

RPPN3 - RPPN7 Industrial pressure switch

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

RDN4 - RDN8 Differential pressure switch

Compact pressure switch Model PCS

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

HV gate valve with protective ring Series 17

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

BETAMINI. The User Friendly OEM Switch

Limit Switch Type 3776

Compact differential pressure switch Models DC, DCC

0190 / Tolerance in psi (bar) at room temperature. Adjustment range in psi (bar) psi. ± 2.90 psi. (± 0.2 bar) (0.3-1.

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move

2/2 Pressure operated valves

Mini pressure switch Stainless steel switch enclosure Model PXS

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

P70, P72, and P170 Controls for Low Pressure Applications

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread

Pressure switch, high adjustability of switch differential

Pressure switch hex 27

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP

Pressure. Pressure. Mechanical. Press. Switches

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

J 6 Se r i e s. Pressure and Vacuum switches. features

Bourdon Tube Pressure Switches

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

TSSE Gas filled thermometer with contacts

Pressure switches hex 24

1/4 BSPP. 500 psi / 35 bar) psi / 35 bar) 8 018X XXX 03 X XXX

Product Information Page

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Waterproof Series Waterproof

CombiTemp Temperature Measuring System

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Differential pressure gauges with Bourdon tube

Data Sheet. A-Series Miniature Watertight Pressure Switches

BRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

PS11 Ultra-Long Life OEM Pressure Switches

flow switches J with pipe tees (inline) J Direct installation (insertion) J for hvac applications J with interchangeable paddles J For air flow

PRESSURE AND TEMPERATURE RECORDER

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

Quick Reference Charts

Accessories Series PSB. Specifications

Compact temperature switch Model TCS

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Electrical position feedback for actuator sizes Ø mm

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

HV gate valve Series 11

Differential pressure switch Model DPS40

Limit Switch Type 4747

Pressure Control, Differential Pressure Control, Type RT

Explosion-Protected Pressure Switches

FLOW SWITCHES. With pipe tees (inline) Direct installation (insertion) For OEM applications Flow monitors. Including products with:

Brass: 200 psi Media: max. 140 F (+93 C); min. 0 F (-18 C) Brass Brass, available with "T" or lever type handle None

Pressure and Temperature Switches

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Differential pressure gauge Model , copper alloy Model , stainless steel version

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Electropneumatic positioner APIS

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

Rod thermostat with micro switch

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

English copy version 2010/REV04 PISTON PRESSURE SWITCH DS-117 / DS-112

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

SATRON VDt Differential Pressure Transmitter

Pressure switches 30 A/F

Metal tube variable area flowmeter for gases, liquids and steam

Servo-assisted 2/2 way piston valve

Plastic tube variable area flowmeter for liquids and gases

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

UHV gate valve Series 10

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106

Technical explanations for mechanical pressure switches

ACCESSORIES AND DIAPHRAGM SEAL

THERMOMETERS FOR TRANSFORMERS

Pressure and temperature controls, Type CAS

Solenoid Valve Island Type 3965

Data sheet pneumatic barring devices KD80-KD200

New compact powerful maintenance-free

2 1 /2" Glycerin-Filled Dual Scale Vacuum Gauges

PRESSURE MONITORING.

For industrial applications For marine applications With proximity switch. Piston type flow switches

GVI Series Industrial Globe Valves for Flow Control

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

Right Angle Control Valve 7051

Type 4746 Electric or Pneumatic Limit Switch

SOLON PRESSURE SWITCHES

Mechanical pressure gauges

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Transcription:

RPP Medium range pressure switches ll industrial environments ll fluids One or two thresholds ll stainless steel version for aggressive environments French lectricity Generating Board (F) electronuclear version Marine version onforms to (Low voltage irective N 73/23/ modified by N 93/68/) These pressure switches maintain a constant level of pressure around a preset value, "Regulatory Function", or actuate an alarm or safety circuit when the pressure being monitored reaches a critical level, "Safety Function". Technical ata (20 ) Black Zamac enclosure and blue cover protected Protection IP 65 to NF N 60529 standard aptive screws for cover attachment Wall-mounting by removable bracket xternal adjustment screw fitted with an antivibration system locking the set point and the deadband, protected by screwed and sealable caps Internal mechanism of bichromate-treated cadmium-plated steel lectrical connections via internal terminal-block with P N 11 cable gland for cable between 7 and 10.5 mm in diameter Internal earth connection alibrated scale for set point reading Pressure connections: G 1/2, female 1/4 NPT, G 1/4 (171, 172, 173 only) Important : ny pulsating circuit must be fitted with pulsation dampeners. Mechanical vibrations should be reduced by means of antivibration mounts fitted to the pressure switches. Normal operation is between 10 % and 90 % of the selected scale. The deadband values given in the tables (see inside pages) are defined under these conditions. The maximum overpressure values correspond to accidental overpressures of limited duration. Technical specifications : Storage temperature: - 40...+ 70 Reproducibility ± 1% of full scale : microswitch ; ± 2% (other microswitches) SPT microswitches xplosion-proof version x d ll T6: certificate N L..I.. 81 60 57-03 Intrinsically safe version x ia II T6: certificate N LI 88 B 6081 X. This version must be used only with an intrinsically safe electrical installation xplosion-proof and intrinsically safe versions valid until 30 June 2003 New TX/94/ certification (in progress) Tests certification : French lectricity Generating Board (F) certification of tests HM063/6864 on ZPN 204 SH Page 1

Operating range RPP - RPPN - RPPH - RPHN (ZP1) low pressure RPP : standard sensing with treated steel flanges and diaphragm according to (1) or (2). RPPN : standard sensing with lower flange in stainless steel 1.4404 (316 L) and diaphragm in Viton. djustable eadband Fixed eadband Fixed eadband t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % mbar bar mbar mbar mbar mbar mbar mbar mbar mbar -50 to 0 0.15 101 (1) 2 to 25 2.5 to 25 6.5 to 25 7.5 to 25 0.5 0.5 2.5 3 Fig 3-2 to 10 0.15 102 (1) 1 to 5 1.2 to5 4.5 to 5 4.5 to 5 0.3 0.3 1.5 1.5 Fig 3-5 to 50 0.15 103 (1) 1.2 to 15 2 to 15 5 to 15 7 to 15 0.4 0.4 1.5 2.5 Fig 3-8 to 100 0.15 104 (1) 1.5 to 25 2 to 25 5 to 25 10 to 25 0.5 0.5 2 2.5 Fig 3-200 to 0 1 151 (2) 6 to 80 8 to 80 15 to 80 15 to 80 2 3 7.5 10 Fig 3 0 to 200 1 152 (2) 6 to 80 8 to 80 15 to 80 15 to 80 2 3 7.5 10 Fig 3 0 to 400 1 153 (2) 15 to 150 20 to 150 30 to 150 35 to 150 4 6 18 25 Fig 3 IMN- (1) Viton diaphragm (2) PM diaphragm RPPH : sensing withstanding overpressure with treated steel flanges and PM diaphragm. RPHN : sensing withstanding overpressure with lower flange in stainless steel 1.4404 (316 L) and viton diaphragm. djustable eadband Fixed eadband Fixed eadband t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % mbar bar mbar mbar mbar mbar mbar mbar mbar mbar IMN- -50 to 0 10 101 2 to 25 2.5 to 25 6.5 to 25 7.5 to 25 0.6 0.6 2.5 3 Fig 3-2 to 10 10 102 1 to 10 1 to 10 4.5 to 10 4.5 to 10 0.4 0.4 1.5 1.5 Fig 3-5 to 50 10 103 1 to 20 2 to 20 4.5 to 20 5 to 20 0.4 0.4 1.5 2.5 Fig 3-8 to 100 10 104 1.5 to 25 2.5 to 25 5 to 25 10 to 25 0.5 0.5 2 3 Fig 3-200 to 0 50 151 12 to 80 20 to 80 25 to 80 40 to 80 3 4 14.5 25 Fig 3 0 to 200 50 152 15 to 80 25 to 80 30 to 80 45 to 80 3.5 4 18 30 Fig 3 0 to 400 50 153 17 to 150 30 to 150 35 to 150 50 to 150 4 5.5 20.5 35 Fig 3 0 to 1000 50 154 22 to 150 35 to 150 45 to 150 60 to 150 6 7 26.5 45 Fig 3 0 to 700 100 171* 20 to 350 40 to 350 40 to 350 70 to 350 7 9 24 50 Fig 3 0 to 1500 100 172* 20 to 350 60 to 350 40 to 350 100 to 350 7 9 24 75 Fig 3 0 to 2500 100 173* 25 to 350 90 to 350 50 to 350 160 to 350 9 11 30 110 Fig 3 T fluid : -15 + 150 T ambient : -25 + 70 } RPP/RPPN * G 1/4 female connection RPPH/RPHN These microswitches can be implemented with two simultaneous contacts : SII (2 x SI), GSS (2 x GS), SHH (2 x SH), GSHH (2 x GSH) Warning : in this case, deadbands are multiplied by 1.5 xplosion-proof model : deadbands are multiplied by 1.5 SM version : consult us. Page 2

Operating range RPP - RPPN - RPP - RPPX (ZP2) medium pressure RPP : standard sensing with brass base plate, tombac bellow or nickel plated piston. RPPN : stainless steel sensing, stainless steel bellow or nickel plated piston. djustable eadband Fixed eadband Fixed eadband t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % bar bar mbar mbar mbar mbar mbar mbar mbar mbar IMN- -1 to 0 1.5 200 25 to 250 35 to 250 80 to 250 95 to 250 5 6 30 42 Fig 4-1 to 2.5 7 201 80 to 1200 100 to 1200 150 to 1200 200 to 1200 22 25 96 120 Fig 4 0 to 0.2 1.5 202 15 to 100 20 to 100 60 to 100 65 to 100 4 5 18 24 Fig 4 0.05 to 1 1.5 203 20 to 400 25 to 400 80 to 400 95 to 400 4 5 24 30 Fig 4 0.5 to 10 15 204 (1) 200 to 3000 250 to 3000 650 to 3000 850 to 3000 45 50 240 300 Fig 4 3.5 to 25 30 205 600 to 5000 1200 to 5000 750 to 5000 1300 to 5000 60 100 720 1440 Fig 4 bar bar bar bar mbar mbar bar bar 5 to 50 65 206 1 to 10 2 to 10 2.5 to 10 3 to 10 150 200 1.5 2.5 Fig 4 5 to 100 220 207 (3) 2.5 to 15 3 to 15 5.5 to 15 6.5 to 15 700 900 3 3.5 Fig 4 20 to 150 220 208 (3) 2.5 to 15 3.5 to 15 5.5 to 15 6.5 to 15 700 1000 3 4.5 Fig 4-1 to 3.5 15 209 0.15 to 1.5 0.2 to 1.5 0.65 to 1.5 0.85 to 1.5 45 50 0.2 0.25 Fig 4 bar bar bar bar bar bar bar bar 25 to 175 800 600 (2) 20 to 80 30 to 80 30 to 80 35 to 80 14 10 24 36 Fig 4 30 to 350 800 601 (2) 20 to 100 30 to 100 30 to 100 35 to 100 16 16 24 36 Fig 4 60 to 600 800 (2) 602 20 to 120 30 to 120 30 to 120 35 to 120 16 16 24 36 Fig 4 (1) 30 bar in stainless steel version (2) sensing with piston (3) stainless steel version only RPP : sensing withstanding overpressure with bichromate finish galvanized base plate and Perbunan diaphragm (code 201 only). RPPX : sensing withstanding overpressure with stainless steel base and diaphragm. (except code 201) djustable eadband Fixed eadband Fixed eadband t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % t 10 % t 90 % bar bar bar bar bar bar mbar mbar bar bar IMN- -1 to +2.5 80 201 0.25 to 2 0.30 to 2 0.8 to 2 1 to 2.5 65 75 0.3 0.35 Fig. 4 0.5 to 10 50 204 0.18 to 3 0.25 to 3 0.63 to 3 0.8 to 3 45 62 0.25 0.3 Fig. 4 3.5 to 25 100 205 0.45 to 10 0.9 to 10 1.5 to 10 3.1 to 10 150 200 0.55 1.1 Fig. 4 5 to 50 100 206 1 to 10 2 to 10 3.5 to 10 7 to 10 200 300 1.5 2.5 Fig. 4 5 to 100 200 207 2 to 25 4 to 25 5 to 25 10 to 25 700 900 2.5 5 Fig. 4 20 to 150 200 208 2 to 25 6 to 25 5 to 25 15 to 25 1500 2000 2.5 7.5 Fig. 4 0.2 to 4 50 210 0.1 to 3 0.18 to 3 0.35 to 3 0.63 to 3 40 50 0.15 0.25 Fig. 4 T fluid : -50...+ 200 ; - 50 + 80 (RPP only) T ambient : -25...+ 55 (all versions) These microswitches can be implemented with two simultaneous contacts : SII (2 x SI), GSS (2 x GS), SHH (2 x SH), GSHH (2 x GSH) Warning : in this case, deadbands are multiplied by 1.5 xplosion-proof model : deadbands are multiplied by 1.5 SM version : consult us. Page 3

imensions (mm) Watertight case Fig. 1 xplosion-proof case ifferential adjustement Set point adjustement 3 holes ø 9 equidistants on ø 22 Sealing hole Window for setting scale able gland able 7 to 12 mm dia (not mounted) arth terminal weight of explosion-proof case: 3 kg Fig. 2 RPP / RPPH / RPPN / RPHN (ZP1) low pressure RPP / RPPN - 101-102 - 103-104 weight : 3 kg RPP / RPPN - 151-152 - 153 weight : 2.8 kg RPPH / RPHN - 101-102 - 103-104 weight : 10 kg RPPH / RPHN - 151-152 - 153 weight : 6.4 kg RPPH / RPHN - 171-172 - 173 weight : 7 kg Fig. 3 Page 4

imensions (mm) RPP / RPP / RPPN / RPPX (ZP2) medium pressure RPP / RPPN - 200-202 - 203 weight : 2.5 kg RPP / RPPN - 201 weight : 2.4 kg RPP / RPPN - 204-205 - 206-207 - 208-209 600-601 - 602 weight : 2 kg RPP - 201 weight : 2.4 kg RPPX - 204-205 - 206-207 - 208-210 weight : 2.4 kg 26/flat square G1/2 male Fig. 4 Operating principle flexing, bellows, diaphragm or piston, actuates one or two microswitches by means of levers. The set point and the deadband are set by springs mounted in opposition. ccessories daptator for welded connection in steel ZRM1 or stainless steel ZRMN 1. Ring siphon steel or 1.4401 (ISI 316) stainless steel. hemical seal (no bottom housing version) Isolating valve. Manifold. Pulsation dampener. Page 5

Options Uncoded options (have to be listed after the code number) Knurled knob for adjustment of the set point (ZB2) knurled knob for adjustment of the deadband (ZB3). Tropicalization (SI and SII microswitches only). Micro N Gold contact (SI and SII microswitches only). Micro M Blow out disc. Socket connector. MRIN version. ll stainless steel construction for aggressive environments (screws and sensing ). Pneumatic version. lectronuclear model, consult us. Specific connection. leanliness for oxygen service. Ordering etails - RPP Model Pressure switch Type ZP1 ZP ZPH ZPN ZPHN ZP2 ZP ZP ZPN ZPX Microswitch** 1 digit 2...4 digit 5 digit urrent rating (resistive circuits) SI 1 standard changeover switch (1xSPT) 5/250Vac 0.5/110Vdc SII 2 simultaneous changeover switches (2xSPT) 2 x 5/250Vac 2x0.5/110Vdc SH 1 hermetically sealed changeover switch (1xSPT) 2.5/250Vac 1/110Vdc GSH 1 herm. sealed ultra sensitive changeover switch (1xSPT) 1/250Vac 2/30Vdc GSHH 2 herm. sealed ultra sensiti. changeover switches (2xSPT) 2 x 1/250Vac 2x2/30Vdc GS 1 ultra sensitive changeover switches (1xSPT) 2 /250Vac 1/30Vdc GSS 2 ultra sensitive changeover switches (2xSPT) 2 x 2/250Vac 2x1/30Vdc SM 2 movable changeover switches 2 x 2/250Vac 2x1/30Vdc SHH 2 hermetically changeover switches (2xSPT) 2 x 2.5/250Vac 2x1/110Vdc *SR 1 changeover switch with manual reset opening on rise 5/250Vac 5/30Vdc *SRF 1 changeover switch with manual resest opening on fall 5/250Vac 5/30Vdc RPxx xx x xxx R PP PPH PPN PHN PP PP PPN PPX B V F G W H J ZP1 ZP2 Range in mbar RPP RPPN RPPH RPHN 101-50 + 0 X X 102-2 + 10 X X 103-5 + 50 X X 104-8 + 100 X X 151-200 + 0 X X 152 0 + 200 X X 153 0 + 400 X X 154 0 + 1000 X 171 0 + 700 X 172 0 + 1500 X 173 0 + 2500 X Range in bar RPP RPP RPPX RPPN 200-1 + 0 X 201-1 + 2.5 X X 202 0 + 0.2 X 203 0.05 + 1 X 204 0.5 + 10 X X 205 3.5 + 25 X X 206 5 + 50 X X 207 5 + 100 X X 208 20 + 150 X X 209-1 + 3.5 X 210 0.2 + 4 X 600 25 + 175 X 601 30 + 350 X 602 60 + 600 X UK/10-2002 This data sheet may only be reproduced in full. Protection Standard xplosion proof IS - Intrinsically safe Hydraulic connection G 1/4 female (171, 172, 173 only) G 1/2 male 1/2 NPT male 6 digit 7 digit Y 2 3 6 8 Pressure range codes in table 8...10 digit xxx * Not possible in xplosion Proof version. ** SPT microswitches only lectronuclear versions : ZPN-M, ZPHN-M, Order under the following commercial references: ZPN-M, ZPHN-M : code = (SHM or HM) Page 6