Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Similar documents
Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

UPFLOW/ HORIZONTAL GAS FURNACE

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Table of Contents GF801U Series

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Value Series Downflow Gas Furnace

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Rheem Value Series Upflow/Horizontal Gas Furnace

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

80% A.F.U.E. DOWNFLOW GAS FURNACES

Sample Residence HVAC Load Calculations

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Cased/Uncased Coils For Gas And Oil Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

G8MVL. Product Specifications

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Cased/Uncased Coils For Gas And Oil Furnaces

Ruud High Efficiency Air Handler

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Product Data. that this product meets the S 95% AFUE S Two -stage operation

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

KG7S (A and K Series)

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Cooling Capacity CFM in. w.c. (125 Pa)

FG7T (A and K Series)

FG7T (E and N Series)

KG7T (E and N Series)

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Rheem High Efficiency Air Handler

Cooling Capacity CFM in. w.c. (125 Pa)

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

FG7S (C and L Series)

F8MTL. Product Specifications

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

KG7T (C and L Series)

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Cooling Capacity CFM in. w.c. (125 Pa)

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Multi-Position, Multi-Speed Gas Furnaces

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

This parts list is current as of the above revision date. See for the current revision.

FG7T (A and K Series)

G9MXE. Product Specifications

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

G9MXE. Product Specifications

Cased/Uncased Coils For Gas And Oil Furnaces

TSTAT0101SC Recommended (sold separately)

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

This parts list is current as of the above revision date. See for the current revision.

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

93% Gas Furnaces Single Stage

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

Transcription:

Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. 80% residential Gas Furnace CSA certified Two stages of operation to save energy and maintain optimal comfort level. 3 way multi poise design UF / HZ PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Solid doors provide quiet operation Solid bottom Insulated blower compartment Low profile 34" cabinet ideal for space constrained installations Blower shelf design serviceable in all furnace orientations Hemmed edges on cabinets and doors 1/4 turn door knobs for tool less access Integrated Control board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet FORM NO. G22-545 REV. 4

Table of Contents TABLE OF CONTENTS Standard & Optional Equipment...3 Model Features/Physical Data & Specifications...4 Model Number Identification...5 Dimensional Data...6-7 Blower Performance Data...8 Accessories...9 Limited Warranty...10 2

Standard & Optional Equipment PATENTED HEAT EXCHANGER DRAFT INDUCER MOTOR IN-SHOT BURNERS DIRECT SPARK IGNITOR INTEGRATED FURNACE CONTROL STANDARD EQUIPMENT Completely assembled and wired; 2 speed induced draft; high and low fire pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multispeed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics. OPTIONAL EQUIPMENT Side and bottom filter frame assembly. 4" Flue Adapter NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. All models can be converted by a qualified Ruud distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Ruud parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% safety lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3

Model Features/Physical Data & Specifications Model Features 80% residential Gas Furnace CSA certified Two stages of operation to save energy and maintain optimal comfort level. 3 way multi poise design UF / HZ PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Solid doors provide quiet operation Solid bottom Insulated blower compartment Low profile 34" cabinet ideal for space constrained installations Blower shelf design serviceable in all furnace orientations Hemmed edges on cabinets and doors 1/4 turn door knobs for tool less access Integrated Controls board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Physical Data and Specifications MODEL NUMBERS R802P SERIES R802PA050314M*A R802PA075317M*A R802PA075417M*A R802PA100417M*A R802PA100521M*A R802PA125524M*A R802PA150524M*A Input-BTU/Hr ➁ 50,000 75,000 75,000 100,000 100,000 125,000 150,000 Heating Capacity BTU/Hr ➀ 41,000 60,000 61,000 81,000 81,000 101,000 121,000 Low Input BTU/Hr ➁ 35,000 52,500 52,500 70,000 70,000 87,500 105,000 Heating Capacity BTU/Hr ➀ 28,000 42,000 42,000 56,000 56,000 70,000 84,000 Heat Ext. Static Pressure.18.20.20.28.28.28.28 Blower (D x W) 11 x 6 11 x 7 11 x 7 11 x 7 11 x 10 11 x 10 11 x 10 Motor H.P. Speed Type 1/3-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 3/4-4-PSC 3/4-4-PSC Min Circuit Ampacity 9 10 12 12 11 12 13 Min. Overload Protection 15 15 15 15 15 15 20 Max. Overload Protection 15 15 15 15 15 20 20 Motor Full Load Amps 5.7 6.7 7.8 7.8 7.5 8.4 9.3 Heating Speed Fire Med-Low Med- Med- Med- Med-Low Med- Med- Heating Speed Low Fire Low Med-Low Low Med-Low Low Low Low Cooling Speed Low Med- Cooling CFM @.70" W.C. E.S.P. 1164 1198 1657 1292 1807 1742 1916 Max. E.S.P. (In. W.C.) 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Temperature Rise Range F Input 25-55 25-55 25-55 35-65 35-65 35-65 45-75 Temperature Rise Range F Low Input 20-50 20-50 20-50 25-55 25-55 30-60 35-65 Max. Outlet Air Temp. F 155 155 155 165 180 165 190 Approx. Shipping Weight (Lbs.) 110 110 125 110 140 150 160 AFUE ➀ 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1 /2" N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate. * S = Standard, X = Low Nox 4

Model Number Identification Model Number Identification R 80 2 P A 075 4 17 M S A Ruud 80 = 80% AFUE 2 = Two Stage P = Premium PSC Design Series A = 1st Design Input BTU/HR [kw] 050 = 50,000 075 = 75,000 100 = 100,000 125 = 125,000 150 = 150,000 3 = Up to 3 Ton 4 = 2 1 /2 to 4 Ton 5 = 3 1 /2 to 5 Ton Cabinet Width 14 = 14".0 17 = 17.5" 21 = 21".0 24 = 24.5" M = Multi X = Low NOx S = Standard Revision- Marketing (A First Time Release) 5

Dimensional Data Upflow Application Dimensional Data: Upflow Model MINIMUM CLEARANCE (IN.) SHIP MODEL A B C D E F WGTS. R802P- LEFT RIGHT BACK TOP FRONT VENT SIDE SIDE (LBS.) 050 14 1 /2 12 27 /32 10 5 /8 ➀ 11 1 /2 1 7 /8 0 4 ➁ 0 1 3 6 ➂ 110 075/ 100417 17 1 /2 16 11 /32 12 3 /8 ➀ 15 1 /2 2 1 /2 0 3 ➁ 0 1 3 6 ➂ 125 100521 21 1 /2 19 27 /32 14 1 /8 ➀ 18 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 140 125 24 1 /2 23 11 /32 15 7 /8 ➀ 22 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 150 150 24 1 /2 23 11 /32 15 7 /8 ➀ 22 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 160 NOTES: ➀ May require a 3" to 4" or 3" to 5" adapter. ➁ May be 0" with type B vent. ➂ May be 1" with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes. 6

Dimensional Data Horizontal Application WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS. Dimensional Data: Horizontal Model MINIMUM CLEARANCE (IN.) SHIP MODEL A B C D E F WGTS. R802P- SUPPLY RETURN BACK TOP FRONT VENT AIR SIDE AIR SIDE (LBS.) 050 14 1 /2 12 27 /32 10 5 /8 ➀ 11 1 /2 1 7 /8 4 ➁ 0 0 1 3 6 ➂ 110 075/ 100417 17 1 /2 16 11 /32 12 3 /8 ➀ 15 1 /2 2 1 /2 3 ➁ 0 0 1 3 6 ➂ 125 100521 21 1 /2 19 27 /32 14 1 /8 ➀ 18 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 140 125 24 1 /2 23 11 /32 15 7 /8 ➀ 22 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 150 150 24 1 /2 23 11 /32 15 7 /8 ➀ 22 1 /2 2 1 /2 0 0 0 1 3 6 ➂ 160 NOTES: ➀ May require a 3" to 4" or 3" to 5" adapter. ➁ May be 0" with type B vent. ➂ May be 1" with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes. 7

Blower Performance Data Blower Performance Data MODEL (-)802PA050314M*A (-)802PA075317M*A (-)802PA075417M*A (-)802PA100417M*A (-)802PA100521M*A (-)802PA125524M*A (-)802PA150524M*A MOTOR H.P. [W] BLOWER SIZE IN 1/3 11 x 6 1/2 11 x 7 1/2 11 x 7 1/2 11 x 7 1/2 11 x 10 3/4 11 x 10 3/4 11 x 10 SPEED TAP Low** Med. Lo* Med. Hi Low Med. Lo** Med. Hi* Low** Med. Lo Med. Hi* Low Med. Lo** Med. Hi* Low** Med. Lo* Med. Hi Low** Med. Lo Med. Hi* Low** Med. Lo Med. Hi* ** Heat Factory Speed Tap **Low Heat Factory Speed Tap Note: Table represents blower performance data WITHOUT filters. CFM AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 823 803 787 732 718 691 651 593 1030 1018 1006 976 929 897 850 808 1129 1132 1112 1087 1054 1028 971 919 1361 1353 1331 1297 1264 1232 1164 1117 1008 1215 1421 1668 1229 1308 1553 1969 1211 1305 1520 1874 1209 1438 1902 2071 1358 1541 1799 2015 1411 1606 1889 2178 977 1181 1408 1648 1200 1267 1542 1924 1183 1261 1498 1810 1182 1420 1883 2037 1354 1517 1774 1989 1395 1579 1891 2160 935 1133 1372 1633 1181 1266 1516 1893 1148 1225 1464 1767 1131 1386 1844 2001 1331 1476 1746 1929 1370 1569 1849 2105 893 1098 1326 1580 1155 1233 1491 1840 1116 1185 1427 1686 1112 1350 1817 1962 1301 1453 1712 1902 1334 1537 1828 2067 854 1065 1299 1545 1120 1204 1451 1803 1077 1157 1387 1678 1051 1320 1753 1905 1250 1416 1691 1862 1310 1499 1764 2024 823 1023 1247 1481 1078 1176 1417 1728 1040 1113 1340 1650 976 1293 1700 1856 1224 1371 1629 1815 1252 1468 1717 1976 777 975 1198 1442 1013 1113 1358 1657 984 1068 1292 1582 929 1248 1636 1807 1154 1339 1554 1742 1220 1407 1659 1916 735 937 1152 1373 970 1062 1306 1570 953 1012 1226 1497 867 1186 1547 1709 1089 1277 1495 1665 1150 1346 1609 1832 8

Accessories SIDE RETURN FILTER RACK: RXGF-CD BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION: RXGF-CB MODEL FILTER RACK FILTER SIZES* INCHES RXGF-CB (UPFLOW/ HORIZONTAL) RXGF-CD (UPFLOW) SIDE RETURN R802PA050 12 1 /4 x 25 15 3 /4 x 25 R802PA075/ R802P100521 15 3 /4 x 25 15 3 /4 x 25 R802PA100417 19 1 /4 x 25 15 3 /4 x 25 R802PA125 22 3 /4 x 25 15 3 /4 x 25 R802PA150 22 3 /4 x 25 15 3 /4 x 25 INDOOR COIL CASINGS 4" FLUE ADAPTER: RXGW-C01 MODEL NUMBER RXBC-D14AI RXBC-D17AI RXBC-D21AI RXBC-D21BI RXBC-D24AI WARNING: IMPORTANT NOTICE A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. FURNACE SOLID BASE BASE WIDTH BOTTOM PLATE NO. PLATE SIZE IN. KIT NO. IN. 14 1 /2 RXGB-D14 AE-61874-01 11 5 /8 x 23 9 /16 17 1 /2 RXGB-D17 AE-61874-02 15 1 /8 x 23 9 /16 21 1 /2 RXGB-D21 AE-61874-03 18 5 /8 x 23 9 /16 24 1 /2 RXGB-D24 AE-61874-04 25 5 /8 x 23 9 /16 FOR HIGH ALTITUDES: OPTION CODE FOR HIGH ALTITUDE: U.S. None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. None required for high altitudes. 80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information. 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts* (Registration Required)...Ten (10) Years Heat Exchanger...Limited Lifetime 10

Notes 11

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.ruud.com Ruud Canada 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A. 1/17 QG FORM NO. G22-545 REV. 4