Retrofit Actuator MS and MS Instructions R L

Similar documents
AV-602. Application. Globe Valve Linkage General Instructions

AV-611. Application. Applicable Literature. Schneider Electric DuraDrive Globe Valve Linkage General Instructions

MX4X-6XXX-20X Series MX4X-7XXX-20X Series

AV-608 Linkage Adapter Kit

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

MF4E MF4E

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

VA-4233-GGx Series Electric Valve Actuators

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

Application. Features

MA-5200 Series MA-5300 Series

MAx1-720x Two Position Series MFx Floating Series MSx Proportional Series

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

NV Direct Coupled Globe Valve Actuator

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

VA-715x Electric Valve Actuator

VA-4233-AGx Series Electric Valve Actuators

Electronic Globe Valves

MK-6600 Series, MK-6800 Series, and MK-6911

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

SAX Electronic Valve Actuator

MS Application. Features. Proportional Valve Actuator General Instructions

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

M9216 Series Electric Spring Return Actuators

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

AM-676, AM , AM-690-R, AM-692, AM-693-R, AM-762, and AM-763

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

SAV Electronic Valve Actuator

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Fisher 2052 Diaphragm Rotary Actuator

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

DP Series Diaphragm Valve Installation and Maintenance Instructions

NETSIAN TECHNOLOGY VALVE SCHEDULE

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

MC-351, 421, 431, MC-4311

VG7000 Valve Linkage for M100 Series Motor Actuators

Ball Valve Bracket Kit

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

Surepowr Series 100 Installation Manual

Electric Actuator Instructions

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

M x Series Valve Linkage Kits

Installation, Operation and Maintenance Manual

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

HQ Series ¼ Turn Electric Actuator

LF Series Spring Return Direct Coupled Actuator

IOM FOR DYNATORQUE D-LOCK LOCKING DEVICE (DL TYPE)

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

VA-715x Electric Valve Actuator

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

AF Series Spring Return Direct Coupled Actuator

VA-7450 Series. Electric Valve Actuators

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Valve Retrofit Installation Instructions for use with Electronic Actuators

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

MA40-704X Series MA41-707X Series MA41-715X Series

HQ Series ¼ Turn Electric Actuator

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Ball Valve Bracket Kit

Mounting UNV Kits to NV Type Actuators

ML7421A,B Electric Linear Valve Actuator

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

Versatile and Powerful

ML6425, ML7425 Spring Return Electric Linear Valve Actuators

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

ELECTRONIC CONTROL ACTUATOR

VA-4233-GGx Series Electric Valve Actuators

HS6B Series Subminiature Interlock Switch

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Transcription:

Retrofit Actuator MS40-7073 and MS40-7153 Instructions R OCK

Ta b l e o f c o n t e n t s Actuator removal instructions Remove existing actuator and linkage electronic hydraulic actuator...................................... 3 Remove existing actuator existing DuraDrive actuator............................................... 3 Assembly Assembling linkage to valve electronic hydraulic actuator only........................................... 4 Spring-return actuators without manual override 2-way valves............................................ 5 Spring-return actuators without manual override 3-way valves............................................ 6 Wiring diagram Typical wiring diagram for MS40 series.................... 7 Environmental specifications Temperature, humidity, and NEMA rating................. 7 P a g e 2 D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s

A c t u a t o r r e m o v a l i n s t r u c t i o n s Note: Personal working on an actuator replacement should wear safety glasses at all times during this changeout. Remove existing actuator and linkage MP55XX electronic hydraulic actuator 1. Disconnect all wiring attached to actuator. 2. Disassemble actuator from valve body by unscrewing actuator from extension. 3. Remove extension from valve body. 4. Using channel locks, compress the spring and square washer on top of spring. Using a flat head screwdriver, turn the brass square nut counter-clockwise to release the washer. CAUTION: Spring is under compression and brass square nut and/or spring could be propelled from valve body if not firmly held. Note: Remove spring, washer, and brass extension attached to valve stem. 5. See Figure 4-1 on page 4. Remove existing actuator existing DuraDrive actuator 1. Disconnect all wiring attached to actuator. 2. Disassemble actuator from linkage. oosen the nuts on the shaft clamp and the anti-rotation shaft. 3. See Figure 5-1 on page 5 for a 2-way valve (STS, Ultra-sorb and steam injection humidifiers). Or see Figure 6-1 on page 6 for a 3-way valve (TS ). D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s P a g e 3

A s s e m b l y Assembling linkage to valve changing from a MP55XX electronic hydraulic actuator to a DuraDrive actuator. Assemble the linkage to the valve, according to Figure 4-1 below. Continue the assembly process according to Figure 5-1 on page 5. Note: Turn to page 5 if replacing an existing DuraDrive actuator. Figure 4-1: Assembling linkage to valve. 1 ocate and remove the two jam nuts taped to the linkage housing, then screw the nuts to the bottom of the valve stem (at least 1/4" of the stem should extend above the top nut). 2 Tighten the jam nuts against each other, using two 5/16" open-end wrenches. 3 Raise the valve stem to the full up position. R OCK Typical Actuator (MS41-707X shown) 5 oosen the shaft clamp nuts and remove the actuator from the linkage. Typical Valve Body (2-Way shown) 4 oosen the anti-rotation screw and disengage it from the slot on the bottom of the actuator. Remove the actuator if necessary. inkage 6 Rotate the pinion shaft CW to fully lower the rack, and then position the linkage over the valve stem. 7 Fully thread the linkage rack onto the valve stem, and then engage the valve mounting nut in the linkage adaptor. 8 Orient the linkage on the valve as desired, and then tighten the valve mounting nut against the linkage adaptor, using a 1-5/8" open end wrench. 9 Rotate the pinion shaft CCW to raise the rack and expose the jam nuts. 10 Tighten the jam nuts against the rack, using a 5/16" open-end wrench on the lower jam nut. P a g e 4 D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s

A s s e m b l y 2-Way valve actuator replacement (stem up closed) Spring-return actuators without manual override MS40-707X and MS40-715X Install the actuator onto the linkage and 2-way valve, and set-up the assembly according to Figure 5-1 below. Figure 5-1: Mounting spring-return actuator on 2-way valve and setting-up actuator/linkage/valve assembly. 1 Rotate the linkage's pinion shaft to the valve open position: Stem Up Closed Valves - Rotate the pinion shaft CW to extend the linkage rack to the down position. COSED OPEN Optional: Affix the Open and Closed labels to the indicator in the appropriate positions. 2 Slide the actuator, "" side facing out, onto the linkage's pinion shaft. 3 Align the actuator with the linkage. 4 Slide anti-rotation screw NYBA-161 half way into the slot on the bottom of the actuator, and then tighten the nut on the anti-rotation screw. NYBA-161 Anti-Rotation Screw for MS40-707X, MS40-715X R R 6 ightly finger-tighten the two nuts on the shaft clamp(s), and then set up the actuator and tighten the shaft clamp(s) as follows: For N.C. Operation, Stem Up Closed Valves a. Power the actuator to the end of stroke MS40-704X, MS40-707X, MS40-715X Proportional Control - Change the reversing switch setting from direct acting () to reverse acting (R), and then apply power to drive the actuator to the end of stroke. 1 b. Verify that the linkage rack is still in the full down position. c. Using a 10 mm wrench or socket, torque the nuts equally on the shaft clamp(s), 8 to 10 lb-ft (11 to 14 N-m). The actuator is now in the open position, at the end of stroke. d. When finished, return the switch setting to direct acting (). 5 Make sure the actuator is in full contact with the plastic stand-offs on the linkage. 1 Caution: When used on a VB-9XXX or similar 1/2" to 1-1/4" (15 mm to 32 mm) valve body, push the valve stem all the way down and adjust the rack to get at least 1/32" (1 mm) clearance above the top of the packing. Use only 35 lb-in. (16 N-m) MS40-704X actuators on obsolete valves. Stem or plug damage may result from using actuators with higher output torques. Apply power to the actuator and check the system's operation for proper operation, in response to the control signal. For electronic hydraulic actuator to DuraDrive actuator, refer to the wiring diagram on page 7. For existing DuraDrive to DuraDrive actuator assembly, refer to wiring diagrams supplied with your humidifier. D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s P a g e 5

A s s e m b l y 3-Way valve actuator replacement Spring-return actuators without manual override MS40-707X and MS40-715X Install the actuator onto the linkage and 3-way valve, and set-up the assembly according to Figure 6-1 below. Figure 6-1: Mounting MS40-707X and MS40-715X and setting-up actuator/linkage/valve assembly. 1 Rotate the linkage's pinion shaft CCW, to retract the rack (stem up). 2 Slide the actuator, "" side facing out, onto the linkage's pinion shaft. COSED OPEN Optional: Affix the Open and Closed labels to the indicator in the appropriate positions. 4 Make sure the actuator is in full contact with the plastic stand-offs on the linkage. 5 Holding the actuator at the 10 position, use a 10 mm wrench or socket to tighten the two nuts equally on the shaft clamp, 8 to 10 lb-ft (11 to 14 N-m). R R OCK 3 Align the actuator with the mounting plate, then rotate it 10 CW. Note that 1-3/8" movement at the anti-rotation slot (measured at the antirotation slot's centerline) is sufficiently equal to 10. 3 Tip: 1 2 1 MS40-707X and MS40-715X actuators are shipped at the end of stroke, without preload. 1-3/8" MS40-707X, MS40-715X Proportional Control - Change the reversing switch setting from direct acting () to reverse acting (R), and then apply power to drive the actuator to the end of stroke. When finished, return the switch setting to direct acting (). 10 1-5/8" Open-End Wrench 2 2 1-5/8" 2 Tip: A 1-5/8" open-end wrench can be used to measure the amount of rotation (measured between opposite sides of the slot). NYBA-161 Anti-Rotation Screw for MS40-707X, MS40-715X 6 Apply power to the actuator to rotate it CCW into alignment with the mounting plate, and then slide anti-rotation screw NYBA-161 halfway into the slot on the bottom of the actuator. Tighten the nut on the anti-rotation screw. 3 Warning: Take care not to pinch your fingers or hand between the actuator and the mounting plate, when powering the actuator into alignment. Caution: When setting the valve preload, power must be used to position the actuator. Do not manually force the actuator into the mounting position. If forced, damage to the pinion shaft or improper close-off may occur. Apply power to the actuator and check the system's operation for proper operation, in response to the control signal. For electronic hydraulic actuator to DuraDrive actuator changeover, refer to the wiring diagram on page 7. For existing DuraDrive to DuraDrive actuator change-over, refer to wiring diagrams supplied with your humidifier. P a g e 6 D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s

W i r i n g d i a g r a m s f o r e l e c t r o n i c h y d r a u l i c a c t u a t o r s t o D u r a D r i v e Figure 7-1: Typical wiring diagram for MS40-7073 and MS40-7153 proportional actuators. Environmental specifications Ambient temperature limits: Shipping and storage, -40 to 60 F (-40 to 71 C) Operating, -22 to 140 F (-30 to 60 C) Humidity: 15 to 95% RH, non-condensing NEMA rating: NEMA 1 (IEC IP30). NEMA 2 (IEC IP54) with conduit connector in the down position D R I S T E E M R e t r o f i t a c t u a t o r i n s t r u c t i o n s P a g e 7

For more information www.dristeem.com sales@dristeem.com DRISTEEM Corporation An ISO 9001 certified company and a subsidiary of Research Products Corporation U.S. Headquarters: 14949 Technology Drive Eden Prairie, MN 55344 800-328-4447 952-949-2415 952-229-3200 (fax) Invensys and DuraDrive are trademarks of Invensys plc and its subsidiaries and affiliates. Specifications may change as design improvements are introduced. 2004 DRISTEEM Corporation Form No. Retrofit instructions, MS40-7073 & MS40-7153 - 03/04 Part No. 890000-116