OPERATOR S MANUAL TWIN REGULATOR LUBRO CONTROL UNIT. Part Number Issue 3 Original Instructions (English)

Similar documents
OPERATOR S MANUAL TORQUE WRENCH CALIBRATOR (TWC) TWC 400 & TWC Part Number Issue 1 Original Instructions (English)

OPERATOR S MANUAL PNEUTORQUE PTM, PTME, TRUKTORQUE SERIES STALL TOOLS. Part Number Issue 5 Original Instructions (English)

OPERATOR S MANUAL HANDTORQUE TM MULTIPLIER WITH INTEGRAL TORQUE TRANSDUCER. Part Number Issue 1 Original Instructions (English)

OPERATOR S MANUAL HANDTORQUE TM MULTIPLIERS. Part Number Issue 9 Original Instructions (English/Deutsch)

PNEUTORQUE PTM, PTME & TRUKTORQUE TM SERIES STALL TOOLS

PNEUTORQUE STANDARD & SMALL DIAMETER SERIES STALL TOOLS

ISO 1500 TORQUE WRENCH LOADER WITH 90 ROTATION

Norbar - Torque Tools. Products

PNEUTORQUE PTM & PTME SERIES EXTERNAL CONTROL (EC) SHUT-OFF TOOLS

Air-Assist Service Jack Max. Capacity: 10 Tons

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

15,000kg HYDRAULIC BOTTLE JACK

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

/ Air Line Kit AL - M1203BS2 / OPERATION MANUAL. P1 - P8 / English P11 - P18 OM-K0652

RATE CONTROLLED TORQUE WRENCH TESTER

SUBMERSIBLE DIRTY WATER PUMP

PURESTREAM -FRL PURESTREAM - FRL. Installation / Operating / Maintenance Instructions Filter Series F1. Specifications.

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

3.25 Ton Heavy Duty Floor Jack

SUBMERSIBLE WATER PUMP

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

2 PCE HYDRAULIC VEHICLE POSITIONING JACKS

Diaphragm Valve Type 14 Pneumatic Model Type AV

1S24V 250. Oil Filtration and Coolant Handling Specialists. Removes Contaminants. Extends Oil Life. Reduces Component Wear.

Ready for outdoor use too!

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

Instruction manual & spare parts lists for models TRP-6 to TRP-90

The mechanism that generates mist (moisture) Principles of water removal valve operation

OPERATING INSTRUCTIONS FOR TPA SERIES AIR DRIVEN TORQUE PUMPS (ANALOGUE GAUGE)

3-Way Ball Valve Type 23H

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

Operating instructions in the back. PD1820LF

1100W PORTABLE GENERATOR

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

OPERATION & MAINTENANCE INSTRUCTIONS

Low Lift Transmission Jack

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

2 Ton - 50 Ton Bottle Jack

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

VT Oil-Free Range Operators Handbook

POWERWASHER OPERATING & MAINTENANCE INSTRUCTIONS. Models: PLS130AB & PLS130AH - PLS200AB & PLS200AH DLS200AL & PLS160AH

Temperature Sensor Series

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

28W WORK LAMP Model: CTL28 Part No:

Operating instructions in the back. PD1420LP

Battery Powered Hydraulic Pump; Kit PN [ ]

Air / Hydraulic Under Axle Jack

SUBMERSIBLE WATER PUMP

Installation & Operation Manual

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

80 Litre Suction Oil Drainer With Inspection Chamber

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

LP 9-20 E PAC. Crowder Supply Co., Inc Roslyn St., Commerce City, CO Toll Free:

18 KG MOBILE SODA BLASTING UNIT

Installation and operating manual

Automated socks packaging machine PS-1

500kg TELESCOPIC TRANSMISSION LIFTER

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

These installation and maintenance instructions must be read in full and completely understood before the installation!

PRODUCT OPERATING MANUAL

Dosage Pumps - Installation Guide

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

Diaphragm Valve Type 16 (Pneumatic Model Type AD)

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

SAFETY AND OPERATING MANUAL

APT14 Automatic Pump Trap Installation and Maintenance Instructions

WPS500X 500 psi /34.5 bar Automotive Pressure Transducer. User s Guide

Free Float Air Trap G8

ACF Operation Manual

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

OWNER S MANUAL PRODUCT CODE: BOD1907

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

OPERATION & MAINTENANCE INSTRUCTIONS

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Diaphragm Valves Type 15

PRODUCT OPERATING MANUAL

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

Air / Hydraulic Floor Service Jack

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

PRODUCT OPERATING MANUAL

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

SUBMERSIBLE WATER PUMPS

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

A Issue F. Instruction Manual. EMF3, EMF10 and EMF20 EMF20 Oil Mist Filter

LARZEP, S.A. LARZEP AUSTRALIA PTY. LTD. LARZEP AUSTRALIA PTY. LTD. Avenida Urtiaga, Wedgewood Road, 49A Sustainable Avenue MALLABIA,

Operation and Maintenance Guide Pneumatic Piston Scabbler

Transcription:

OPERATOR S MANUAL TWIN REGULATOR LUBRO CONTROL UNIT Part Number 34375 Issue 3 Original Instructions (English)

CONTENTS Safety 2 Introduction 3 Parts Included 3 Spare Parts 3 Features and Functions 3 Set up Instructions 4 Preparation 4 Hose Connection 5 Operating Instructions 6 Before Use 6 Daily Checks 6 Torque Select 6 Set Outlet Pressure 7 Lubricator Flow 7 Maintenance 8 General 8 Repair 8 Lubricator Filling and Bowl Replacement 8 Draining Condensate 8 Filter Element Replacement and Filter Bowl Replacement 9 Pressure Gauge 10 Cleaning 10 Disposal 10 Specifications 11 Trouble Shooting 11 1

SAFETY IMPORTANT: DO NOT OPERATE THIS PRODUCT BEFORE READING THESE INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR DAMAGE. This product is intended for controlling the air pressure to Norbar PneuTorque and similar pneumatic tools. Any other use is not recommended. Read pneumatic tool manual before use. It is recommended to have an air isolation device located in the air supply close to this product. Isolate the tool from all energy sources before changing or adjusting the drive square or socket. Compressed air can be dangerous for those unfamiliar with it. Only trained and experienced personnel should setup, operate and maintain pneumatically operated equipment. Only connect to a clean dry air supply. To avoid hazard from whipping air hoses make all connections before turning on the air supply. Ensure any connected tool is turned to OFF to prevent potential movement. Failure to follow proper maintenance procedures could cause the product to malfunction and could lead to damage to the equipment. Before filling or maintaining this product, all compressed air should be exhausted. If equipment is to be removed, first switch off air and electrical supplies and exhaust all residual compressed air in the system. Do not make any modifications to the product. Do not take the product apart, except where specified in the Maintenance section. Keep this manual available for whenever necessary. 2

INTRODUCTION The Norbar Twin Regulator Lubro Control Unit provides a controlled output air pressure for powering pneumatic tools. The twin regulators allow the user to instantly change between two different air pressure settings without having to make a time consuming adjustment. In addition, the unit removes excess saturated water and solid foreign particles that could damage the connected tool. Parts Included Description Twin Regulator Lubro Control Unit Hose 3m ½ BSP M/M Adaptor ½ BSP Seal Operators Manual Picture Part Number 16075 28911 28946 28906 34375 NOTE: A 6 metre long hose is also available as an optional accessory. Spare Parts Description Pressure Gauge Filter Element Filter Bowl Lubricator Bowl ½ BSP Swivel Adaptor Adjuster Knob Picture Part Number 28913 28914 28939 28940 28905 19376 FEATURES AND FUNCTIONS Switch between two independent torque settings with a separate exhaust setting to remove any residual air trapped in the system. Adjustable pressure control for pneumatic tools. Ability to supply controlled oil feed for lubrication of connected tool. Bowl to remove excess saturated water that could damage the connected tool. 5μm filter element to remove solid foreign particles that could damage the connected tool. Input pressure up to 145 psi / 10 bar. Output pressure from 7.25 psi / 0.5 bar to 100 psi / 6.9 bar 3

SET UP INSTRUCTIONS Preparation NOTE: If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. WARNING: TO AVOID HAZARD FROM WHIPPING AIR HOSES MAKE ALL CONNECTIONS BEFORE TURNING ON THE AIR SUPPLY. Air pressure adjusters Oil Drop Sight Glass / Adjuster Torque Select Inlet port (IN) Filter Bowl Outlet Port (OUT) Drain Valve Pressure Gauge FIGURE 1 Features Lubricator Bowl Recommended Installation Considerations: Follow any applicable regulations and standards, e.g.: ISO 4414:1998 Pneumatic fluid power General rules relating to systems Install near an air isolation valve. Keep enough space around the unit for safe operation and maintenance. Install horizontally to allow all features to operate as intended. Do not use in a place subject to heavy vibrations and/or shocks. Use flexible hoses to reduce any load or vibration being passed to the unit. Keep hose length and the number of fittings / connectors to a minimum. Handle with care to avoid damage to the precision components. Do not expose the product to direct sunlight for an extended period of time. Do not mount the product in locations where it is exposed to radiant heat. Ensure installation area is within temperature limits. Where a reduction in water vapour content is required, an air dryer should be considered. Ensure inlet air pressure does not exceed 145 psi / 10 bar / 1.0MPa. Fill lubricator bowl before installation (see Maintenance section (page 8)). 4

Hose Connection Ensure all hoses are clean and free from any foreign material. TIP: When using thread sealing tape start 1.5 to 2 threads from the end of the thread to ensure Potential loose tape cannot enter the air supply. 1. Connect the tool air hose to the outlet port on the right hand side. Use a minimum hose size of ½ (12mm) bore. Tighten to 28-30 N m. Do not over tighten as threads have a taper fitting. TIP: To connect the air inlet hose to a ½ bore hose use a ½ BSP Male/Male connector. A pair of spanners will be required to perform this task (22mm ( 7 8 ) A/F and 24mm ( 15 16 ) A/F open-ended spanners). Use ½ BSP male/male connector (supplied) to connect air hose to Norbar PneuTorque. Tighten to 28-30 N m. Do not over tighten as threads have a taper fitting. 2. Connect the inlet port on the left hand side to the air supply. Use a minimum hose size of ½ (12mm) bore. Tighten to 28-30 N m. Do not over tighten as threads have a taper fitting. 3. Before applying air, ensure complete air system is connected. Ensure any connected tool is switched to OFF to prevent potential movement. 4. Apply air supply. 5. Check for leaks. 5

OPERATING INSTRUCTIONS Before Use Ensure the Twin Regulator Lubro Control Unit has been connected and set up correctly. Ensure the inlet air pressure is present. Daily Checks Ensure lubricator bowl has sufficient oil. Do not drop below MIN. OIL LEVEL. Ensure filter bowl is below MAX. DRAIN LEVEL. Ensure lubrication flow is correct. Torque Select Turn torque select to TORQUE 1, EXHAUST or TORQUE 2. Use Exhaust to remove any residual air left in the Twin Lubro system before switching between TORQUE1 and TORQUE 2. If any residual air in the Twin Lubro system is not fully exhausted before switching torque setting, this will lead to a higher than intended torque output. IMPORTANT: BEFORE SWITCHING BETWEEN TORQUES ANY RESIDUAL AIR LEFT IN THE SYSTEM MUST BE EXHASTED FOR AN ACCURATE TORQUE. FIGURE 2 Torque Select 6

Set Outlet Pressure Refer to connected pneumatic tool for required outlet pressure. WARNING: DO NOT SET THE PRESSURE ABOVE MAXIMUM INDICATED ON THE PRESSURE GAUGE. NOTE: MAKE ADJUSTMENTS BY HAND, THE USE OF TOOLS MAY DAMAGE THE ADJUSTER. FIGURE 3 Front adjuster for TORQUE 1. FIGURE 4 Rear adjuster for TORQUE 2 Lift the air pressure adjuster to unlock. Rotate adjuster clockwise to increase outlet pressure. Rotate adjuster counter-clockwise to decrease outlet pressure. NOTE: To allow for tool air consumption the tool MUST be operating whilst adjustment is made. Adjust until the desired outlet pressure is indicated on the pressure gauge. Push the air pressure adjuster down to lock in position. Select other torque setting and adjust if required. Check outlet pressures regularly to ensure they are still accurate. TIP: For forward / reverse applications set TORQUE 1 to required tightening torque and set TORQUE 2 to the untightening torque. Lubricator Flow Many air tools are designed to operate with a small amount of oil in the air flow; the Twin Regulator Lubro Control Unit has the facility to allow this. Refer to air tool manual for required flow rate. Run the tool to draw air flow. Count the number of oil drops per minute in the oil sight glass. Turn sight glass clockwise to decrease oil flow. Turn sight glass counter clockwise to increase oil flow. FIGURE 5 Lubricator Flow 7

MAINTENANCE WARNING: ALWAYS COMPLETE MAINTENANCE TASKS ON A CLEAN WORK AREA. ALWAYS WEAR SUITABLE GLOVES AND EYE PROTECTION. WARNING: COMPRESSED AIR CAN BE DANGEROUS. SETUP, MAINTENANCE AND REPAIR OF PNEUMATIC SYSTEMS MUST BE PERFORMED BY QUALIFIED PERSONNEL ONLY. BEFORE MAINTENANCE ENSURE ALL AIR IS EXHAUSTED AND ALL ELECTRICAL POWER IS OFF. General Perform periodic checks for lubricator bowl level, the filter bowl level and amount of dirt in the filter bowl. Also check on the general condition of all hoses and features looking for cracks and leaks. Replace / fix any faults found. Repair Repairs not specified in this manual should be carried out at Norbar or by a Norbar approved agent. Lubricator Filling and Bowl Replacement The lubricator bowl is located on the right of the unit. Step 1. Exhaust all air. 2. Remove bowl. 3. Fill. 4. Replace bowl. Draining Condensate Procedure See WARNINGS at start of section. Read warning on the lubricator bowl. Pull down lock. Turn through 45 (left or right) Then pull bowl out. Replace bowl if damaged. Fill to MAX. OIL LEVEL with specified oil. Use FUCHS SILKAIR VG22 or SHELL TELLUS S2 VX15. Align marking on lubricator bowl and assembly. Insert lubricator bowl into assembly and rotate 45 (left or right) until the lock is up. FIGURE 6 Lubricator Bowl Replacement The filter bowl collects condensate from the air supply. The amount of condensate depends on the air consumption. Drain the filter bowl before the level reaches MAX. DRAIN LEVEL. Step 1. Exhaust all air. 2. Drain condensate. 8 Procedure See WARNINGS at start of section. Read warning on the filter bowl. Place waste receptacle under filter bowl. Press drain valve to release condensate. FIGURE 7 Draining Condensate

Filter Element Replacement and Filter Bowl Replacement The life of the filter element depends on product usage and air supply quality. Under typical usage with a clean air supply replace the filter element every 2 years. If the outlet pressure is low or the flow is restricted check the condition of the filter. The filter element is Part Number 28914. The filter element is within the filter bowl. Baffle Connector Filter Element Baffle FIGURE 8 Filter Bowl Components Step 1. Exhaust all air. 2. Remove filter bowl. 3. Remove filter element. Procedure See WARNINGS at start of section. Read warning on the bowl. Pull down bowl lock. Turn through 45 (left or right). Pull bowl out. Replace bowl if damaged. Rotate and lift out the baffle connector with filter element and baffle attached. Rotate baffle anti-clockwise by hand. Remove baffle. Remove filter element. 4. Clean filter bowl. Use natural detergent only 5. Insert new filter element. Slide the new filter element onto the baffle connector. Place the baffle on the end of the baffle connector and rotate clockwise by hand until part locks. Insert the baffle connector with newly attached components into the filter bowl and rotate until secure. 6. Insert filter bowl. Align mark on bowl with assembly. Insert bowl. Rotate bowl 45 (left or right) until the lock is up. FIGURE 9 Replacing the Filter Element 9

Pressure Gauge The gauge is a precision item that must be treated with care. The body of the Lubro Control Unit is fitted with a ⅛ M / ¼ F BSP adaptor for the pressure gauge. If the gauge is damaged replace as follows: Step Procedure 1. Exhaust all air. See WARNINGS at start of section. Use 14mm spanner to hold nut on back of the gauge and 17mm spanner on 2. Remove gauge. adaptor. Rotate gauge counter-clockwise to remove. When using thread sealing tape start 1.5 to 2 threads from the end of the 3. Prepare new gauge. thread to ensure potential loose tape cannot enter the air supply. Use 14mm spanner to hold nut on back of the gauge and 17mm spanner on 4. Replace gauge. adaptor. Rotate gauge clockwise to mount. Tighten to 12 14 N m. 5. Apply operating Check for proper operation and possible air leaks. pressure. Cleaning Do not use abrasives or solvent based cleaners. Disposal This symbol on the product indicates that it must not be disposed of in the general waste. Please dispose of according to your local recycling laws and regulations. Contact your distributor or see the Norbar web site (www.norbar.com) for further recycling information. 10

SPECIFICATIONS Input port thread: Output port thread: Minimum hose bore: ½ BSP. ½ BSP. ½ (12mm). Input pressure: Maximum 145 psi / 10 bar / 1.0 MPa. Proof rating 217 psi / 15 bar / 1.5 MPa. Output pressure: Minimum 7.25 psi / 0.5 bar. Maximum 100 psi / 6.9 bar. Pressure gauge range: Pressure gauge accuracy: Filtration: Drain capacity: Oil: 0 to 100 psi / 0 to 6.9 bar. +/- 2.5% of scale (+/- 2.5 psi for Max 100 psi pressure gauge) 5μm. 45 cm³. FUCHS SILKAIR VG22 or SHELL TELLUS S2 VX15 or equivalent. Weight: Twin Regulator Lubro Control Unit 6.5 Kg. Hose 3m 1.5 Kg. Dimensions: Environment: Ambient and fluid temperature: 375 mm high x 425 mm wide x 180 mm deep. Indoor use within a light industrial environment. -5 C to +60 C (No freezing). Due to continuous improvement all specifications are subject to change without prior notice. NOTE: If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment could be impaired. TROUBLE SHOOTING Tips are located within the manual to help with troubleshooting. Common problems are listed below: Problem Air flow reduced. Pressure not regulated. Pressure will not return to zero. Air leak. Unit will not drain. Fluid in outlet hose. Oil does not drop Likely Solutions Filter element is clogged; see Maintenance (page 8) for replacing. Check orientation of INLET PORT and OUTLET PORT connections. Possible valve or spring damage; return to Norbar. Possible valve, spring or O ring damage; return to Norbar. Investigate area of leak. Check for loose part, crack or break of component or foreign matter in system. Always tighten components to correct torque value. Foreign matter in outlet drain. Clean / replace bowl assembly. Filter bowl is full; see Maintenance section (page 8) to drain filter bowl. Replace filter element if necessary. Ensure sight glass is turned counter clockwise to increase flow. Ensure air flow is sufficient to allow oil flow. Ensure amount of oil in lubricator bowl is sufficient. Ensure there are no air leaks from the lubricator bowl. 11

NORBAR TORQUE TOOLS LTD Wildmere Road, Banbury, Oxfordshire, OX16 3JU UNITED KINGDOM Tel + 44 (0)1295 270333 Email enquiry@norbar.com NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop #07-20 Pantech Business Hub SINGAPORE 128383 Tel + 65 6841 1371 Email enquires@norbar.sg NORBAR TORQUE TOOLS 45 47 Raglan Avenue, Edwardstown, SA 5039 AUSTRALIA Tel + 61 (0)8 8292 9777 Email enquiry@norbar.com.au NORBAR TORQUE TOOLS (SHANGHAI) LTD 7 / F, Building 91, No. 1122, Qinzhou North Road, Xuhui District, Shanghai CHINA 201103 Tel + 86 21 6145 0368 Email sales@norbar.com.cn NORBAR TORQUE TOOLS INC 36400 Biltmore Place, Willoughby, Ohio, 44094 USA Tel + 1 866 667 2279 Email inquiry@norbar.us NORBAR TORQUE TOOLS INDIA PVT. LTD Plot No A-168, Khairne Industrial Area, Thane Belapur Road, Mahape, Navi Mumbai 400 709 INDIA Tel + 91 22 2778 8480 Email enquiry@norbar.in www.norbar.com Norbar Torque Tools Ltd 2016