Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

Similar documents
CUKUROVA GENERATOR SYSTEMS

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

Perkins 1006TAG2 diesel engine Newage/Stamford UCI274F alternator Standard Generator Features

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

C U K U R O V A GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 404D-22G diesel engine Newage/Stamford BCI184E alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

CUKUROVA GENERATOR SYSTEMS

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

Volvo TAD732GE diesel engine Leroy Somer LSA 46.2 M3 alternator Standard Generator Features

Voltage. kva kw kva kw

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

Volvo TAD941GE diesel engine Leroy Somer LSA 46.2 VL12 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

GNS 670 P. Stand-by power: 670 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

GNS 1100 P. Stand-by power: 1100 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

WPS20/S EP Series. Features:

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

130 KW / 165 KVA POWERED by

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

GNS 630 V. Stand-by power: 630 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GNS 500 V. Stand-by power: 500 kva. Diesel Generating Sets, made for Europe

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

WPS350/S EP Series. Features:

500 KW / 625 KVA POWERED by

Standby Amper VOLTAGE

70 KW / 90 KVA POWERED by

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GNS 400 V. Stand-by power: 400 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

60 KW / 75 KVA POWERED by

WPS100/S EP Series. Features:

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

WPS250/S EP Series. Features:

57 KW / 71 KVA POWERED by

WPS60/S EP Series. Features:

300 KW / 375 KVA POWERED by

WPS150/S EP Series. Features:

400 Series 404A-22G1 ElectropaK 20.3 kwm / rpm

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

1100 Series 4.4TW2GM Marine Auxiliary Engine kw (143.2 hp) gross prime 1800 rpm

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATOR SET MTU 12V1600 DS660

Volvo TAD1344GE diesel engine Leroy Somer LSA 47.2 S4 alternator Standard Generator Features

130 KW / 165 KVA POWERED by

GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

16 KW / 20 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

DIESEL GENERATOR SET MTU 10V1600 DS500

4000 Series TRG3 Diesel Engine ElectropaK rpm

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

4000 Series TAG3A Diesel Engine ElectropaK rpm

Diesel generator set QSK23 series engine

400 Series 404D-22G ElectropaK rpm

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

640 KW / 800 KVA POWERED by

400 Series 403A-15G1 ElectropaK 13.2 kwm / rpm

PPU Diesel Power 50/60Hz Containerized Generator Set

8,000 Watt Diesel Generator

ژنراتور : Alte Mecc. موتور دیزل Penta: Volvo KVA KW KVA KW

SIDE VIEW FRONT VIEW

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

Transcription:

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 6 cylinder, water cooled engine 50 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features ISO 9001:2000 This generator is available with CE certification Automatic load transfer panel Automatic syncronization and power sharing systems Soundproof canopy Container type enclosers Road trailer Job-site trailer Protection circuit breaker Air start Remote type radiator Base fuel tank External type fuel tank Automatic fuel transfer system Residential silencer Standby Prime kva kw kva kw CJ110PC 115 92 105 84

Perkins 1006TG2A Engine Standard Features Standby kw Prime kw Gross Net Gross Net Economic Power Single side servicing for reduced service time and cost. Unique Quadram combustion system enables high power output plus low fuel consumption and noise. Rated speed is changable between 1500 rpm or 1800 rpm allowing standard builds to operate at either 50 Hz or 60 Hz. Clean, Efficient Power Operator and environmentally friendly with low noise, rapid startibility and low emissions that satisfy TA Luft requirements. 1006TG2A 105 84 Lubricating System Pressurized Capacity, Liters 16,1 Lub oil pressure, kpa 345-414 Flat bottomed aluminium fan Spin-on ful flow oil filters Oil cooler 95,5 76 Durable Power Maximum cooling efficiency is provided by gear driven water pump and independent fan drive. Leak free operation is ensured by Viton crankshaft seals and sophisticated controlled swell joints, giving protection in the thoughest conditions. Inserted valve seats, oil spray cooled pistons and compact plate cooler give enhanced engine life. Relaible power Wherever a Perkins' Electropak engine is put into service, it will never be far from the support provided by a global network of 4000 distributors and dealers, all backed by a parts distribution centre giving 24 hours service, 365 days a year. Fuel System of injection system Direct injection Fuel atomiser Multi-hole Fuel injection Pump Rotary type Delivery/hour at 1500rev/min, Liters 122.4 Governor type Mechanical integral Rotary fuel injection pump Mechanical governing - speed control to BS5514 Class A1,ISO 3046-4M3 Spin-on full flow fuel oil filters and pre-filter Cold start aid Technical Specifications Electrical System Manufacturer Number of cylinders Cylinder arrangement Displacement, Liters Bore X Stroke, mm Compression Ratio Combustion System Aspiration Rotation Gross engine power, kwb Fan Power, kwm BMEP gross, kpa Combustion air flow, m³ / min Exhaust gas temp.(after turbo), C Exhaust gas flow (after turbo),m³ / min Mean piston speed, m / s PERKINS 1006TG2A 4 cycle, water-cooled, diesel engine 6 Vertical In-line 5.99 100 X 127 16.0:1 Direct injection Turbocharged, air to air charge cooled Clockwise viewed on the flywheel 105 5 1263 5,74 550 16,24 6.35 Alternator 12/24V options Starter motor (DC) 12/24V options Oil pressure switch and coolant temperature switch 12 volt starter motor and 55 amp alternator Fuel Consumption liters per hour gallons per hour %110 Load %100 Load %75 Load %50 Load %110 Load %100 Load %75 Load %50 Load 24.1 L 21.8 L 16.5 L 11.4 L 5.3 gallons/hour 4.8 gallons/hour 3.6 gallons/hour 2.5 gallons/hour Cooling System Tropical, heavy duty type Ambient temperature, C 50 Engine+Radiator coolant cap., Liters 27.7 Pressure cap setting, kpa 75 Thermostat controlled cooling system with gear driven water pump. Fan drive and 22" pusher fan Radiator (and piping) with fan guards

Mecc Alte ECP 34-2S/4 Standard Features Range The ECO generators are available with a 50/60 Hz frequency, either with 2 poles ranging from 8 to 114 KVA or with 4 poles ranging from 6.5 to 3,000 KVA, with a single or double support.in order to couple them with the prime mover it is possible to choose among a wide range of flanges and couplings. Mechanical Structure The robust mechanical structure permits easy access to the connections and components during routine and extraordinary maintenance check-ups. The materials used for the manufacture of the mechanical structure are the following: FeP12 steel for the frame, C45 steel for the shaft and cast iron for the end-brackets. The standard degree of protection is IP21 or IP23; upon the customer s request, other higher degrees of protection, such as IP45, IP54, etc., are available. Insulation And Impregnation Insulation is of class H standard. Impregnation is made with tropicalized epoxy resins by dipping and dripping, whilst for the high voltage parts by vacuum, so that the insulation level is always very good. In the highpower models, the stator windings undergo a further insulation. Special treatments for particular environmental conditions are available on request. Regulation The self-regulation is obtained through an electronic regulator. The regulator is fed by an auxiliary winding which guarantees an almost constant supply under any possible operating condition of the generator. The ECO series can be equipped with the new interchangeable U.V.R.6-F or S.R.7/2-G regulator,ensuring the same performance. Voltage Accuracy The voltage accuracy is ±1% in static condition with any power factor and with speed variation between 5% and +30% with reference to the rated speed. Standby Prime kva kw kva kw ECP 34-2S/4 116 93 115 92 Technical Specifications Manufacturer Mecc Alte ECP 34-2S/4 4-Poles, Rotating Field, Brushless Standby power at rated voltage, kva 116 Efficiency, % 92 Power factor 0.8 Phase 3 Frequency, Hz 50 Speed, Rpm 1500 Voltage, V 380/415 Excitation Self excited Stator winding 12 ends Regulation Simplified Regulator,seventh generation Voltage Regulator SR7/2 Voltage Regulation, % ± 1,5 R.F.I Suppression EN50081-1; EN50082-1; VDE0875K. For others standards apply to factory Waveform Distors.at f. load LL/LN % 1,8 / 1,9 Waveform Distors.at no load LL/LN % 2,8 / 2,9 Rotor with damping cage Overspeed, Rpm 2250 Short circuit current >300% TIF Telephone Interference THF < 2% Insultion class H Stator Winding Resistance (20 C), Ω 0,02 Rotor Winding Resistance (20 C), Ω 2,951 DE bearing 6314.2RS NDE bearing 6311.2RS Protection class IP 21 (other protection on request) Voltage Regulation The voltage can be regulated by the VOLT potentiometer of the electronic regulator. By connecting a 100K potentiometer in the proper terminals it is also possible to obtain a remote voltage regulation in a range of 5% of the rated voltage. Optional Equipment Anti Condensation Heaters Air Filters Temperature Indication RTD s Winding Protection Thermistors SR7/2 AVR Simplified Regulator,seventh generation Standards The entire series is manufactured according to and complies with the most common specifications such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/CSA C22.2 N 14-95 N 100-95; special versions are available on request to meet specific specifications and regulations.

Control Panel Standard Equipments Features Datakom DKG307 digital automatic control module Hourmeter Emergency stop button Automatic mains failure with genset control and protection Remote Start operation capability Analogue temperature and oil pressure inputs Genset KW and Power Factor measurement Engine hours run counter Periodic maintenance request display 165 programmable parameters Battery backed-up real time clock Weekly operation schedule programs Daily, weekly, monthly exerciser Event logging with time stamp Statistical counters Serial RS-232 data output for telemetry on PC Free MS-Windows remote monitoring SW Configurable analogue inputs: 2 Configurable digital inputs: 7 Configurable relay outputs: 2 Output expansion capability Small dimensions (155x115x48mm) Datakom DKG307 Control Module Description The DKG-307 is a comprehensive AMF unit for a single generating set operating in standby mode. In AUTOMATIC position, DKG-307 monitors mains phase voltages and controls the automatic starting, stopping and load transfer of the generating set in case of a mains failure and once the generator is running, it monitors internal protections and external fault inputs. If a fault condition occurs, the unit shuts down the engine automatically and indicates the failure source with the corresponding red led lamp. The DKG-307 provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations and operating sequences. The unauthorized access to program parameters is prevented by the program lock input.all programs may be modified via front panel pushbuttons, and do not require an external unit. The fault conditions are considered in 2 categories as Warnings and Alarms. Measured values have separate programmable limits for warning and alarm conditions. The service request indicator lamp turns on at the expiration of either engine hours or time limits. It is possible to monitor the operation of the system locally or remotely with the WINDOWS based PC utility program. The unit is designed for front panel mounting. It is fitted into the cut-out with the steel spring removed.connections are made with 2 part plug and socket connectors. Pushbutton Controls STOP / START AUTO, TEST, MANUAL LCD PAGE Input Functions display on LCD Generator Volts Volts L1-N, L2-N, L3-N Generator Volts Volts L1-L2, L2-L3, L3-L1 Generator Amps Amps L1, L2, L3 Generator Frequency Hz Mains Volts Volts L1-N, L2-N, L3-N Mains Volts Volts L1-L2, L2-L3, L3-L1 Mains Frequency Hz Engine Speed RPM Plant Battery Volts Volts Engine Hours Run Hour Generator total power kva L1, L2, L3,total Generator total power kw L1, L2, L3,total Generator power factor Cosφ L1, L2, L3,total Optional Input Functions Engine Oil pressure kpa Fuel level % Engine Temperature C Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits

Codes and General Information CJ 110 P C C Group - Alternator brand (Mecc Alte) P Series - Engine brand (Perkins) Standby Power - kva Perkins 1000 Series Diesel Engine Mecc Alte Alternator 1006 T G 2A ECP 34 2 S 4 Number of poles Power level Genset Engine Turbocharged Information Power Ratings 1000 Series, 6 cylinder Electric Formulas Standby power rating is for the supply of emergency power at variable load for the duration of the non-avalaibality of the mains power supply.no overload capacity is available at this rating.a standby rated engine should be sized for an avarage load factor of 80% based on published standby rating for 500 operating hours per year.standby ratings should never be applied except in true emergency power failure conditions. Prime power rating is available for unlimited hours per year with a variable load of which the average engine load factor is 80% of the published power rating, incorporation of a 10% overload for 1 hour in every 12 hours of operation which permitted Values kwe kwe kva I (Amp) Frequency Formula kwm X E (U x I x 1.73 x pf) / 1000 kva x pf (U x I x 1.73) / 1000 kwe / pf (kwe x 1000) / (U x 1.73 x pf) (kva x 1000) / (U x 1.73) ( Rpm x N Pole) / (2 x 60) Continuous power rating is available for continuous full load operation.no overload is permitted. Acc. to ISO 3046/1, BS 5514, DIN6271 Rpm kwm: Mechanical Power kwe : Electrical Power pf : Power factor E : Alternator efficiency (2 x 60 x Frequency) / N Pole I : Current (A) U : Voltage (V) kva : Power Rpm: Revolutions per minute

O I General Dimensions Standard Generator W Length, L Heigth, H Width, W 2,20 m 1,5 m 1.15 m H Weight, Total 1250 kg L Generator with Soundproof Canopy W Length, L 3,3 m Heigth, H 2 m H Width, W Weight, Total 1,2 m 1700 kg L Generator Room Layout 1,5 m 1,4 m 2 m 2,5 m 1,2 m 4,5 m