Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV

Similar documents
Distribution transformers Efficiency over life-cycle

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

INESING GROUP. Power System Solution

Power IT RESIBLOC Dry Type Distribution Transformers. 250 kva up to 40,000 kva

ABB Ltd. FACTORY IN HANOI

ABB Transformers Egypt

EMPAC Metal enclosed capacitor bank for wind applications

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

TRANSFORMERS UP TO 750 kv

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

OLIVER ONLINE VOLTAGE REGULATION

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Cast resin transformers

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

MEDIUM POWER TRANSFORMER

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

AIR CORE REACTORS. Phoenix Electric Corporation

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Key features. DESIGNS: - Conservator type - Hermetically sealed

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

TGK Prefabricated Substation Technical Data

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

Our Global Solutions CAPABILITIES

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Surge arrester POLIM-H..SD

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SERIES TAP-CHANGER

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

Standard Features and Accessories

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

History of the company. TUMETIC and TUNORMA: Tailor-Made Technology

LV Capacitors QCap-L series Capacitors for power factor correction

Power and Distribution Transformers

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

Marine generators Proven generators for reliable power on board

Surge arrester POLIM-C.. HD

Surge arrester POLIM-H.. ND

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Mini contactors B6, BC6 with 3 pole

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Large Power Transformers

A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY

Transformers Global product offering

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

Power Voltage Transformers for Air Insulated Substations

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

DRY TYPE TRANSFORMERS

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

CAST RESIN TRANSFORMERS

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

B kv T&D GAS INSULATED SWITCHGEAR

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

SECTION PADMOUNT TRANSFORMER - OIL FILLED

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

The construction features of EdM transformers

B kv Gas-insulated Substations

Unit Substation Transformers 5 and 15 KV Class

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

Brochure. Synchronous generators for diesel and gas engines Proven generators reliable power

Powering industry since 1947.

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Prime Power Energie Systems Inc.

Green T.HE. High efficiency Transformers. THE Global specialist in electrical and digital building infrastructures

NXPLUS C Single busbar. Maintenance-free for lifetime

ZX2 Gas-insulated medium voltage switchgear

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Voltage limiting device HVL

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Combined instrument transformers

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

Low voltage bushings for pad-mounted distribution transformers Technical information guide

ZX-Family Gas-insulated medium voltage switchgear

Transcription:

Power IT Liquid Filled Transformers IEC standard, small and medium, rated power 2000kVA, HV 36kV

Even our standard solutions are special In almost every place where people live and work you will find at least one transformer. But as long as it keeps working and supplying power to the escalator in the department store, the hotel lift, the office computer, the oven in the local bakery, the farm machinery or the petrochemical plant nobody gives it a second thought. However, transformers are one of the most important units in every production process. Without them the core activities of nearly every business and factory would come to a standstill with serious financial consequences. After nearly 100 years developing and manufacturing transformers we are well aware of this dependency. This is why we never compromise on the performance, security or reliability of our products. Nor on design, materials, manufacturing methods, environmental protection or recycling. Our objective is to support you and to add value to your activities by offering a comprehensive range of top quality transformers. We also provide top class service and support. With this approach we can tailor the most appropriate technical solution to every problem. A high quality solution with better service and support, better for the environment and yet with greater availability and a lower total cost ownership than our competitors. All over the world in underground railways, in amusement parks and every place where people work or live you will find ABB transformers at work. ABB invites you to find the optimal solution to your application and to see with your own eyes that even our standard solutions are special.

Mission ABB is a global leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. Introduction to ABB ABB is the worlds leading supplier of Distribution Transformers. We offer: Introduction to Industrial IT Industrial IT is ABB's name for a powerful commitment to solutions for Real-Time Automation and Information. Industrial IT guides every step ABB takes going forward in technology, business processes, and more. All ABB Distribution Transformer products are Industrial IT certified, which guarantees structured, easy accessible and online documentation. It can be viewed on its own but also as a part of a larger system. All technologies (Dry/Liquid) All standards (IEC, ANSI, etc) Applications up to 72,5 kv Facts and figures (approx) Production facilities around the world: 30 Countries with Sales and Services centers: 140 Number of units sold yearly: 400.000 Quality statement Working with us, you have access to a worldwide network of factories and facilities serving you locally with a full range of products and solutions. Our warranty provides one ABB quality and service. Working together gives you access to production facilities using Industrial IT and the most up to date technologies, providing the highest quality for standard and specialty products as well as solutions. Our production facilities are ISO 9001/14001 certified. Our aim is to deliver your distribution transformers fast, on time and conform to your specifications. ABB 3

Construction features Description ABB Distribution Transformers manufacture a wide range of oil and dry type transformers. This brochure describes three phase oil type distribution transformers up to 2000 kva and 36kV. They are used to step down three-phase high voltage to low voltage for power distribution, mainly in urban areas and for industrial applications. Our standard transformers are designed for use in moderate climates and can be installed both outdoors and indoors. The loading capability is designed to comply with IEC 354. Distribution transformers can be hermetically sealed (the tank is completely filled with oil) or equipped with an oil conservator. Tanks are constructed with flexible corrugated walls (fins), which enables sufficient cooling of the transformer. The corrugated walls also compensate for the changes in the oil volume during operation. An advantage of the hermetically sealed transformers is that oil is never in contact with the atmosphere thus avoiding periodic oil analysis. Our transformers are adaptable for pole mounting or assembly in substations. Standard features Hermetically sealed: Corrugated tank HV and LV DIN bushings Off-circuit tap changer Oil drain valve Oil filling plug on the cover Lifting lugs Earthing terminals Rating plate Mineral oil (inhibited or uninhibited) Overpressure valve ABB technology Common Technology (CT) Our transformers are manufactured to provide you with a high quality and reliable transformer. ABB have developed a Common Technology (CT) platform, which defines design standards, equipment and processes used in all our factories. Use of this Common Technology enables us to guarantee our customers a high quality and consistent product. The key production features of our small and medium distribution common technology are: oval core step lap automatic cutting and stacking of core legs windings directly wound on the core legs or mandrels with 2 HV coils in parallel (smallest units) epoxy diamond dotted paper insulation between LV layers tapered or full width layer insulation in HV windings What we achieved is: standardisation of products automation of production stable process and quality high reliability higher LV insulation level Additionally, for transformers with a conservator: Magnetic oil level indicator Buchholz relay Oil filling plug on the conservator Dehydrating breather Other product types with different dimensions and technical specifications can be designed and manufactured on request. 4 ABB

ABB 5

Core The magnetic circuit is of the three-column type with mitred joints. It is manufactured with firstrate, grain oriented magnetic, cold-rolled silicon steel laminations. The mounted core is clamped down in order to reduce vibrations and minimize noise levels. Further noise level and no load losses decreasing are achieved by step lap core construction. Core design is an important factor of any transformer s efficiency. The geometric core arrangement and the materials chosen determine the losses and noise levels. Grain oriented transformer sheet steel is used in the core construction. It is cut by the most modern, fully automated core cutting machinery and assembled into limb and yoke sets. This results in high dimensional accuracy, excellent space factor, and low loss values. By using step-lap technology, the no-load currents can be reduced improving the drawbacks associated with reactive power compensation. Windings The windings are made of two components, conductor material and the insulation material. The conductors used are a high grade electrolytic copper or aluminium. They are insulated with pure cellulose or double enamel. The HV windings are wound either with round, double enamel insulated, or rectangular, paper insulated wire. The LV windings are wound with rectangular paper insulated wire, enameled wire or foil. The windings are designed to meet the customer s insulation level requirements and also to withstand the short circuit forces as outlined in IEC 60076-5. The neutral points of LV windings are brought up to the tank cover. 6 ABB

Off-circuit tap changer The tappings of the HV winding, are connected to the off-circuit tap changer located horizontally between the yoke and the tank cover. The handle is located on the cover and should only be operated when the transformer is de-energized. The design prevents setting the off-circuit tap changer to intermediate positions. The mechanism can also be padlocked during normal transformer operation. Insulating liquids The mineral oil both inhibited and uninhibited types - with its electrical and chemical characteristics is in compliance with the IEC Standards and is P.C.B. and P.C.T. free. ABB provides and promotes its own solution as well. BIOTEMP is biodegradable, vegetable-oil-based dielectric insulating fluid used in electrical transformers. The product reduces environmental threats posed by transformer insulating oil spills. On special requests other fluids are available. ABB 7

...manufactured, assembled, tested and painted in the factory Tank and cover Tank walls are made of corrugated cooling surfaces. The bottom plate, side and frames are of welded construction. The welds are tested for oil tightness. All protection device flanges, bushings, tap switch drive and lifting lugs are fitted on the tank cover. The cover is bolted to the tank frame. The underbase channel is welded to the base plate and the rollers are suitable for either longitudinal or transverse movements. Single pole 3-phase transformers are delivered with flat base as standard, but optionally can be equipped with underbase channel beams where bi-directional wheels are a requirement. The complete tank is tested and approved according to CENELEC HD 428.6 S1 standard. Special type lifecycle tests of more than 10 000 cycles simulating over 30 years operation were carried out with positive results. Painting and surface treatment All metal parts are carefully sand-blasted. The initial protective coating is made up of a single coat of one pack epoxy paint. The final paint coating is made up of several coats of paint. Alternatively, hot dip galvanized transformers can be supplied for use in heavy corrosion areas. All units are painted in RAL 7033 but other colours are available on request. Detailed painting procedures for different environmental conditions are also available. Options and accessories Plug-in bushings on HV side Dial type thermometer with or without contacts Oil level indicator Pressure relief valve with or without contacts Multifunction protection device Cable boxes Off-circuit tap changer with 3-7 positions (9 on request) Thermometer pocket Skid base or bi-directional rollers Integrated pole brackets on tank Arcing horns Dual voltage transformers Galvanized tank 8 ABB

ABB 9

Quality and testing Our production facilities where all ABB transformers are manufactured are certified acc to ISO 9001 and ISO 14001. At the end of the manufacturing process the transformers are individually tested in accordance with the IEC Standards. The routine tests are: Voltage ratio and phase displacement IEC 60076-1 Insulation resistance IEC 60076-1 Applied voltage test (insulation to ground) IEC 60076-3 Induced voltage test (winding insulation) IEC 60076-3 No load loss test IEC 60076-1 Winding resistance IEC 60076-1 Impedance and load loss test IEC 60076-1 Control wiring, auxiliary operation. Upon request, witnessed type/special tests can be carried out: Insulation lighting impulse test IEC 60076-3 Temperature rise test IEC 60076-2 Sound level test IEC 600551 Partial discharge test IEC 600270 Specially designed reinforced transformers suitable for pole mounting, protected with arcing horns are tested in accordance with to SFS 2646 steep wave execution! 10 ABB

ABB 11

References ABB has thousands of liquid filled transformers at work all over the world in many different applications, such as utilities, windmills, compact substations and industrial transformers. ABB is different offering the best and most reliable products acc to meet the demanding requirements of all our customers. We offer our customers: Quality guaranteed by the most modern technology, equipment, processes and constantly improved in ABB R&D centres all over the world Speed the shortest delivery time within days instead of weeks Production and management processes based on the newest Industrial IT factory concept to allow control production every minute in the real time Focus Factories concept specialized factories that are focused on specific product ranges to deliver consistent quality and competitive products across the globe. 12 ABB

Outline drawing 1 Thermometer pocket 2 Tap-changer handler 3 Oil drain valve 4 Rating plate 5 Lifting lug 6 LV bushings 7 HV bushings 8 Filling plug 9 Roller ABB 13

Technical Data HV uk kva NLL LL losses L W H oil weight total weight Lwa (75 C) comb. appr. appr. appr. appr. appr. kv % W W mm mm mm kg kg db 50 10 4 50 190 1100 A - A' 780 670 890 90 365 55 50 125 1350 B - C' 880 670 890 90 370 47 50 125 1100 A - C' 780 670 890 90 375 47 50 125 875 C - C' 860 645 890 100 420 47 20 4 50 190 1100 A - A' 840 645 1015 100 395 55 50 125 1350 B - C' 780 620 1015 95 375 47 50 125 1100 A - C' 840 645 1015 110 420 47 50 125 875 C - C' 900 670 1015 130 475 47 Wheelbase (D): 520mm Wheel diameter: 125mm 100 10 4 100 320 1750 A - A' 840 795 1040 130 580 59 100 210 2150 B - C' 1140 745 1090 150 610 49 100 210 1750 A - C' 1140 745 1090 145 660 49 100 210 1475 C - C' 900 670 1090 150 690 49 20 4 100 320 1750 A - A' 1200 770 1065 145 625 59 100 210 2150 B - C' 1200 770 1065 145 605 49 100 210 1750 A - C' 1200 770 1065 145 625 49 100 210 1475 C - C' 960 690 1115 165 680 49 Wheelbase (D): 520mm Wheel diameter: 125mm 160 10 4 160 460 2350 A - A' 1060 690 1140 180 840 62 160 300 3100 B - C' 960 740 1140 180 805 52 160 300 2350 A - C' 1060 690 1140 180 840 52 160 300 2000 C - C' 1060 690 1140 180 865 52 20 4 160 460 2350 A - A' 1020 715 1215 205 880 62 160 300 3100 B - C' 1060 690 1215 180 825 52 160 300 2350 A - C' 1020 715 1215 205 880 52 160 300 2000 C - C' 1020 715 1215 205 905 52 Wheelbase (D): 520mm Wheel diameter: 125mm 200 10 4 200 550 2850 A - A' 1120 715 1140 200 960 65 200 360 3800 B - C' 1120 865 1140 215 960 55 200 360 2850 A - C' 1120 715 1140 200 960 55 200 360 2450 C - C' 1120 765 1140 200 1010 55 20 4 200 550 2850 A - A' 1120 765 1215 200 990 65 200 360 3800 B - C' 1120 865 1215 210 980 55 200 360 2850 A - C' 1120 765 1215 200 990 55 200 360 2450 C - C' 1380 780 1215 230 1090 55 Wheelbase (D): 520mm Wheel diameter: 125mm 250 10 4 250 650 3250 A - A' 1320 765 1245 205 1110 65 250 425 4200 B - C' 1320 815 1245 215 1100 55 250 425 3250 A - C' 1320 765 1245 205 1110 55 250 425 2750 C - C' 1020 715 1275 200 1160 55 20 4 250 650 3250 A - A' 1080 780 1320 220 1135 65 250 425 4200 B - C' 1320 765 1245 230 1140 55 250 425 3250 A - C' 1080 780 1320 220 1140 55 250 425 2750 C - C' 1080 780 1350 230 1230 55 Wheelbase (D): 520mm Wheel diameter: 125mm 14 ABB

HV uk kva NLL LL losses L W H oil weight total weight Lwa (75 C) comb. appr. appr. appr. appr. appr. kv % W W mm mm mm kg kg db 400 10 4 400 930 6000 B - A' 1420 890 1350 270 1350 68 400 930 4600 A - A' 1350 850 1420 260 1310 68 400 610 6000 B - C' 1500 940 1400 280 1340 58 400 610 4600 A - C' 1250 850 1500 260 1400 58 400 610 3850 C - C' 1260 850 1540 340 1600 58 20 4 400 930 6000 B - A' 1420 890 1400 270 1350 68 400 930 4600 A - A' 1350 850 1470 260 1310 68 400 610 6000 B - C' 1500 940 1450 280 1340 58 400 610 4600 A - C' 1250 850 1550 260 1400 58 400 610 3850 C - C' 1260 850 1590 340 1600 58 Wheelbase (D): 670mm Wheel diameter: 125mm 500 10 4 500 1100 5500 A - A' 1420 850 1420 280 1500 69 500 730 5500 A - C' 1470 850 1810 310 1720 59 20 4 500 1100 5500 A - A' 1420 850 1470 280 1500 69 500 730 5500 A - C' 1470 850 1860 310 1720 59 Wheelbase (D): 670mm Wheel diameter: 125mm 630 10 4 630 1300 8400 B - A' 1590 1010 1530 350 1800 70 630 1300 6500 A - A' 1220 980 1530 410 2155 70 630 860 8400 B - C' 1800 1100 1620 400 2070 60 630 860 6500 A - C' 1200 900 1580 390 2040 60 630 860 5400 C - C' 1220 850 1630 340 2040 60 10 6 630 1200 8700 B - A' 1660 1010 1490 410 1810 70 630 1200 6750 A - A' 1420 850 1540 390 1900 70 630 800 8700 B - C' 1580 1010 1520 360 1800 60 630 800 6750 A - C' 1220 980 1510 400 2000 60 20 4 630 1300 8400 B - A' 1590 1010 1580 395 1790 70 630 1300 6500 A - A' 1220 980 1580 410 2155 70 630 860 8400 B - C' 1800 1100 1670 400 2070 60 630 860 6500 A - C' 1200 900 1630 390 2040 60 630 860 5400 C - C' 1220 850 1700 340 2040 60 20 6 630 1200 8700 B - A' 1660 1010 1530 410 1810 70 630 1200 6750 A - A' 1420 850 1590 390 1900 70 630 800 8700 B - C' 1580 1010 1570 360 1800 60 630 800 6750 A - C' 1220 980 1560 400 2000 60 Wheelbase (D): 670mm Wheel diameter: 125mm 800 10 6 800 1300 10000 B - A' 1740 1090 1530 490 2230 72 800 1300 8500 A - A' 1680 940 1540 430 2190 72 800 920 10000 B - C' 1470 980 1620 460 2400 62 800 920 8500 A - C' 1560 870 1570 460 2270 62 20 6 800 1300 10000 B - A' 1740 1090 1580 490 2230 72 800 1300 8500 A - A' 1680 940 1590 430 2190 72 800 920 10000 B - C' 1470 980 1670 460 2400 62 800 920 8500 A - C' 1560 870 1620 460 2270 62 Wheelbase (D): 670mm Wheel diameter: 125mm ABB 15

HV uk kva NLL LL losses L W H oil weight total weight Lwa (75 C) comb. appr. appr. appr. appr. appr. kv % W W mm mm mm kg kg db 1000 10 6 1000 1700 13000 B - A' 1770 1080 1740 610 2650 73 1000 1700 10500 A - A' 1780 1100 1630 500 2520 73 1000 1100 13000 B - C' 1700 1120 1800 550 2740 63 1000 1100 10500 A - C' 1900 1220 1600 510 2750 63 20 6 1000 1700 13000 B - A' 1770 1080 1790 610 2650 73 1000 1700 10500 A - A' 1780 1100 1680 500 2520 73 1000 1100 13000 B - C' 1700 1120 1850 550 2740 63 1000 1100 10500 A - C' 1900 1220 1650 510 2750 63 Wheelbase (D): 820mm Wheel diameter: 160mm 1250 10 6 1250 2100 15400 B - A' 1900 1180 1760 640 3030 75 1250 2100 13000 A - A' 1880 1170 1810 600 3080 75 1250 1320 15400 B - C' 1960 1250 1750 605 3210 65 1250 1320 13000 A - C' 1880 1180 1730 620 3340 65 20 6 1250 2100 15400 B - A' 1900 1180 1810 640 3030 75 1250 2100 13000 A - A' 1880 1170 1860 600 3080 75 1250 1320 15400 B - C' 1960 1250 1800 605 3210 65 1250 1320 13000 A - C' 1880 1180 1780 620 3340 65 Wheelbase (D): 820mm Wheel diameter: 160mm 1600 10 6 1600 2600 20000 B - A' 1940 1160 2040 900 3880 76 1600 2600 17000 A - A' 1990 1270 1860 680 3640 76 1600 1700 20000 B - C' 1930 1240 1760 640 3610 66 1600 1700 17000 A - C' 1980 1160 1800 750 4140 66 20 6 1600 2600 20000 B - A' 1940 1160 2170 945 4050 76 1600 2600 17000 A - A' 1990 1270 1910 680 3640 76 1600 1700 20000 B - C' 1930 1240 1810 640 3610 66 1600 1700 17000 A - C' 1980 1160 1850 750 4140 66 Wheelbase (D): 820mm Wheel diameter: 160mm 2000 10 6 2000 3100 21000 A - A' 2070 1290 2040 870 4530 80 2000 2100 21000 A - C' 1960 1140 1900 870 4590 70 20 6 2000 3100 21000 A - A' 2070 1290 2090 870 4530 80 2000 2100 21000 A - C' 1960 1140 1950 870 4590 70 Wheelbase (D): 820mm Wheel diameter: 160mm Above data are only examples to give an overview of possible standard transformers. Transformers can be optimized with respect to capitalised losses for optimization of Total Cost of Ownership (TCO). ABB 16

Distribution transformers offered by ABB Liquid filled distribution transformers: - up to 72,5 kv - single phase and three phase - ground mounted, pole mounted or pad mounted Dry transformers: - Open Wound - Vacuum Cast Coil - RESIBLOC Services offered by ABB Distribution Transformers - Environmental Services - PCB Elimination Services - Installation and Commissioning - Training - Testing and maintenance - Retrofits, Revamping and up-grading - Spare parts procurement - Technical information available from abb.com/distributiontransformers Transformers for special applications like: - Railway application - Marine: propulsion and distribution - Carrier Vessel Nuclear - Rectifier Transformers - Variable Speed Drive - Excitation Transformers - HVDC Converter - Transformers for windmills - Autotransformers - Grounding/Earthing Transformers - Neutral Earthing Reactors - Current Limiting Reactors - Arc Furnace - Boostertransformers 17 ABB

Leaflet Ident. no. 1LAC000005 Printed in Germany (04.04-2000-COW) ABB Transformers Power Technologies Division Affolternstrasse, 44 8050 Zurich Switzerland www.abb.com/transformers e-mail: info@abb.com Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction in whole or in parts is forbidden without ABB s prior written consent. Copyright 2004 ABB All rights reserved.