Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Similar documents
kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

TECHNICAL DATA SHEET KVA UPS Systemss

Liebert Hipulse-E TM. 500kVA - 800kVA AC Power for Business-Critical Continuity

Liebert. FP 50Z kva

Technical Data Sheets

Nfinity Battery Run Time Charts

Technical Data Sheets

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Technical Data Sheets

POWER kva

EFFEKTA Power Supplies

1.1 GENERAL CHARACTERISTICS

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Master Plus kva

PowerValue 11/31 T kva

LIEBERT: A CLEAR PATH TO THE FUTURE

TLE Series UPS 400/500 kw With eboost Technology

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 160/200/225/250 kw with eboost Technology

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Technical Data Sheets

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Data Sheets

TLE Series UPS 750/1000 kw With eboost Technology

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Master Plus kva

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS Multi Sentry 10-20kVA

Est FlexiPower Mini UPS FPX Mini kVA

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Master MPS kva kva 3:1 3:3 VFI TYPE

MKN-DSP SERIES - THREE PHASE

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Industrial PFC UPS System

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

MASTERYS IP+ 10 to 80 kva

MGE TM Galaxy TM 7000 GFC

POWERTRONIX QUASAR 5-40 KVA

Green Power 2.0 MASTERYS GP

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Master MPS kva kva 3:1 3:3 VFI TYPE

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

MGE TM Galaxy TM 7000

PowerWave 33, kw

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Flywheel UPS Systems, kva

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Onfiniti. 1 Phase UPS

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

AME. Rectifier - Battery charger. Industrial applications: Key features:

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Technical data sheets

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

DC POWER SUPPLY SYSTEMS

Est DCM Double Conversion Module 400kVA - 800kVA

60 to 160 kva.

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Transcription:

Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems

We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions for the benefit of our customers We re the world leader in providing Business-Critical Continuity to organizations like yours, enabled by our product and service centres of expertise Liebert, is one of industry-leading Product Brand for many technology solutions in power systems, connectivity, embedded power, outside plant, precision cooling and monitoring The Liebert Adaptive Architecture TM creates a power and cooling infrastructure for IT systems that can meet the highest availability requirements, enhance operation flexibility and reduce the cost of ownership 2

Liebert Hipulse E Hi-Availability UPS The growth of mission critical applications in today's digital world and the increased dependence of your business on such applications have led Emerson Network Power to design Liebert Hipulse E UPS to provide you with reliable, high-availability power Having extensively surveyed customers needs and thoroughly mapped their requirements, Hipulse E has been carefully designed to deliver maximum Return On Investment (ROI) The Liebert Hipulse E provides industry-leading overload and short-circuit capability 3 Phase 110% for 1hour 125% for 10 min 150% for 1 min 1 Phase 200% for 30 sec Inverter Short-Circuit 3 phase = 15 times nominal current 1 phase = 29 times nominal current for <5 sec (EN 50091-1) 3

Liebert Hipulse ensures you the highest availability From scalability to redundancy, from user-friendliness to maintainability, from parallel ability to connectivity, and from investment protection to lower cost of ownership, whichever values you need, Liebert Hipulse E provides industry leading efficiency Liebert Hipulse E, is the top line in our range of power quality solutions for mission critical applications, some of which are listed below Liebert Hipulse E (with true on-line double conversion topology) comes in five popular ratings, ranging from 300 to 800 kva (400 V, 50/60 Hz) With a set of options and features that address customer needs by providing value and achieving high availability and reliability The New Liebert Hipulse E with its parallel redundant and dual bus configurations is best in class for MTBF and MTTR, providing your critical load with the optimum availability With a dual bus system, availability can reach 99,9999999 4

The best flexibility in and adaptability to load type (Leading PF compatibility) Load compatibility The trend in ICT loads is to absorb a capacitive PF especially in light load conditions Hipulse has an innovative design that adapts the UPS output filter to the capacitive PF and an output transformer with a rating that is optimised to handle these loads With Liebert Hipulse E you can tune the output filter by matching different load power factor values With the option of the internal Xtreme power factor, a wide range of output power factors can be covered, increasing the maximum value of active power Different factory settings enable the unit to provide its max power performance whatever the load power factor is 1) Level 1: No kw derating for a load PF range from 095 lead to 08 lagging 2) Level 2: No kw derating for a load PF range from 09 lead to 09 lagging Medium flexibility with Xtreme PF1 Maximum flexibility with Xtreme PF09 Line compatibility The new Liebert Hipulse E provides optimum harmonic reduction, thanks to three key features: - Upstream Green Power through low input current THDI & high input power factor using different solutions by way of 6-pulse with harmonic filter or 12-pulse with passive harmonic filter, depending on the requirement - Further reduced THDI can be achieved with the addition of the Active Filter as an external option; this reduces the cost of ownership thanks to an improved input power factor that will reduce electricity costs 5

The new Liebert HipulseE provides you with an extremely efficient way of using the UPS Available in single module or dual bus configuration, the Intelligent ECOMode improves UPS Efficiency by up to 98% Efficiency without compromise and lower ownership costs The brand new Intelligent ECOMode option Intelligent ECOmode gives you many advantages and cost savings: Set UPS control either in double conversion or ECOmode without any impact on the load Immediately achieve significant energy savings in existing data centers Save energy continuously or in periodical cycles and transfer to double conversion when the utility exceeds the ITIC limit Ecomode can be activated in various ways, depending upon the customer s needs Compared with a double conversion running at a typical efficiency of around 93% at full load (92% at 50% of Load), annual savings on the UPS can be considerable (@ 01 /kwh) Indirect effect Generally, the UPS is kept in an air conditioned room The heat losses from the UPS must be compensated for by air conditioning, which further increases electricity consumption Therefore, UPS efficiency affects the degree of air conditioning required Cost saving per year at 01 /kwh (estimation) At 50% /year 6996 9327 11659 13991 18655 UPS At 100% /year 11534 15379 19223 23068 30757 Cooling at 100% load /year 300 kva 400 kva 500 kva 600 kva 800 kva 3845 5126 6408 7689 10252 6

How much you can save and how 1) With the power utility within a user-adjustable voltage range, the UPS is working on bypass at high efficiency The inverter is always syncronised with the bypass 2) If the grid exceeds the pre-fixed limits, the UPS switches immediately to double conversion 3) For wide grid variation, the UPS switches to battery, continuously feeding the load 7

This operation mode reduces the cost of ownership by saving energy The UPS can work either in DOUBLE CONVERSION or in ECO-MODE and either continuously or in duty cycles fixed by the user The cost savings in ECO-MODE operation vs DOUBLE CONVERSION, working at 93% of full load efficiency, are sumarised in the following graph, in continuous operation at 100% of load and with an energy cost of 01 /kwh Total cost saving Cost saving UPS Cost saving Cooling 8

Value-added power options Liebert Hipulse E offers you an array of value-added options listed below: External Battery circuit breaker (wall or cabinet mounted) Battery cabinet Main static switch (MSS) for centralised static bypass switch Wrap-around maintenance bypass cabinet Top cable entry Input isolation transformer Remote alarm monitor (wall mounted) Internal Paralleling kit (for 1+5 modules) Input harmonic filter Common battery sharing kit Fan failure alarm Power communication option IP protection: IP21 - IP30 - IP31 Special feature applications (SFA s)* Dynamic system expander (DSE) Multi-bus (2-bus, 3-bus and 4-bus) *On request 9

Multi bus configurations Liebert Hipulse E is designed to include numerous useful optional configurations The top 4 are listed below: Hot Stand-by 1 + N with Distributed Bypass Parallel configuration without centralised bypass N + 1 with Centralized Bypass Parallel configuration with centralised bypass Multi Bus (2-bus, 3-bus, 4-bus) 2- bus configuration with HiSwitch2 Normal Mains Normal Mains Normal Mains Normal Mains UPS 1 UPS 2 UPS6 MSS LOAD *Both HiSwitch and HiSwitch2 are compatible 10

General Characteristics - [Liebert Hipulse E] Model Name Hipulse E Nominal Power Rating at 08 PF Load KVA 300 400 500 600 800 Input Parameters Input Voltage to Rectifier Vac 380/400/415*(400V:nominal) 3-phase, 3-wire Input Voltage to Bypass Vac 380/400/415*(400V:nominal) 3-phase +N, 4-wire Permissible Input Voltage Range Vac 323 to 457 Input Frequency Hz 50 or 60 Permissible Input Frequency Range Hz 47 or 63 Input THDi at nominal voltage at full load % <4-5% with 12-pulse + Filter Input Power Factor at nominal voltage >=0,90% with 12-pulse + Filter Flexi Power Walk-In second 5 to 120 (selectable) Battery & DC Parameters Battery Type VRLA (Valve Regulated lead Acid) or Wet or NiCd Nominal Battery Bus Vdc 396 (Float Voltage: 446V) 480 396 480 (F V: 540V) (F V: 446 V) (F V: 540V) End-Cell Voltage Vdc/Cell Selectable from 1,65 to 1,90 (for VRLA/Wet Cells) DC ripple voltage in float & Const V Chmode % <1 (RMS value) Temperature compensated Battery Charging Optional Output Parameters Inverter Type IGBT-based Sine-Sine PWM Cotrolled Output Power KW 240 320 400 480 640 Output Voltage Vac 380/400/415* (400V:nominal) 3-phase, 4-w Output Voltage Regulation % +/- 0,5 (3 phase RMS average) Output Frequency Hz 50 or 60 Output Frequency Regulation % +/- 0,05 Output Voltage THD at nominal voltage % 1 (typ), 2% (max) Capability to handle High Crest Factor Load 3:1 (compliant with IEC 62040-3) Capability to handle Step Load % 0-100 or 100-0 Transient Recovery m seconds 10 (recovery to 95% of the voltage level) Capability to handle Leading PF Load Up to 0,7** Voltage Displacement el 120 +/- 1 el (with 100% unbalanced load) Overload Conditions %FL 110 for 60 minutes 125 for 10 minutes 150 for 1 minutes System Parameters UPS Efficiency (without any power option) % Up to 98% in ECOmode Physical Parameters & Standards Width (applicable to 6 pulse version)*** mm 1640 2460 Not Applicable Width (applicable to 12 pulse version)*** mm 2280 2460 2460 3200 4410 Depth mm 850 1000 Height mm 1900 Weight 6p (approx) Kg 1850 2400 Not applicable Weight 12p (approx) Kg 2540 3100 4200 4500 5050 Colour Ral 7021 - Ral 7035 Front door Opening (for better Serviceability) More than 180 Degree of Protection for UPS Enclosure IP 20 even with front door in opened condition Standards & Conformities IEC 62040-3, IEC 62040-2, IEC 62040-1-1, CE Mark ; EN 62040-1-1, EN 50091-2, EN62040-3, EN 60950, EN 60529 and VFI 111 Enviromental Parameters Storage Temperature Range C -25 to 70 (UPS) & -20 to 30 (Battery) Operating Temperature Range C 0 to 40 (UPS) & 20 +/- 5 (Battery) Relative Humidity % 0 to 95 (non condensing) Maximum Altitude above MSL (Mean Sea Level) m 1000 (as per IEC 62040/3) * 4-5% more power output for 415V input & output ; ** with suitable derating; ***with OR without input harmonic filter While specifying the parameters here, it is assumed that, extremes of all the conditions do not apply simultaneously While every precaution has been taken to ensure accuracy and completeness in this brochure, Liebert Corporation assumes no responsibility, and discaims all liability for damages resulting from use of this information or for any errors or omissions 2004 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners 11

Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business- Critical Continuity TM from grid to chip for telecommunication networks, data centers, health care and industrial facilities Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, embedded computing and power, integrated racks and enclosures, power switching and controls, monitoring and connectivity All solutions are supported globally by local Emerson Network Power service technicians Liebert power, precision cooling and monitoring products and services from Emerson Network Power improve the utilization and management of data center and network technologies by increasing IT system availability, flexibility and efficiency For more information, visit wwwliebertcom, wwwemersonnetworkpowercom or wwweuemersonnetworkpowercom Locations Emerson Network Power - Headquarters EMEA Liebert Business Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 marketingemea@emersonnetworkpowercom Emerson Network Power - Service EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 9719045 serviceemea@emersonnetworkpowercom Emerson Network Power Ltd Fourth Avenue, Globe Park Marlow, Buckinghamshire, SL7 1YG UK Tel: +44 (0) 1628 403 200 Fax: +44 (0) 1628 403 294 ukenquiries@emersonnetworkpowercom While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2010 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners HIPEE-BRO-EN-0909-01 Emerson Network Power TM The global leader in enabling Business-Critical Continuity TM wwweuemersonnetworkpower com marketingemea@emersonnetworkpowercom AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Out Side Plant Power Switching e Controls Precision Cooling Rack & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2010 Emerson Electric Co