Drive Technology \ Drive Automation \ System Integration \ Services Catalog AC Motors DRS, DRE, DRP 71 315 DT56, DR63, DVE 50/80 Morskate Aandrijvingen BV Oosterveldsingel 7A 7558 Edition PJ Hengelo 01/010 (Ov) The Netherlands T +31 (0)7-760 11 11 F +31 (0)7-760 11 19 info@morskateaandrijvingen.nl www.morskateaandrijvingen.nl K.v.K. Enschede 0607393 BTW nr. NL 00160960B01 ABN-AMRO rek.nr. 59.09.83.350 IBAN: NL75ABNA0590983350 BIC: ABNANLA 168710 US
for the DR. motor series.1 for the DR. motor series AC motor series DRS.. Standard efficiency motor DRE.. High efficiency motor DRP.. Premium efficiency motor 71-315 Sizes: 71 / 80 / 90 / 100 / 11 / 13 / 160 / 180 / 00 / 5 / 315 K - L Lengths: K= very short / S = short / M = medium / L = long MC/LC = Rotors with copper cage,, 6, 8/, 8/ Number of poles Unit designation DR: Output variants /FI /FG /FF /FT /FL /FM /FE /FY /FK /FC IEC foot-mounted motor with specification of shaft height 7 Series integral motor, as stand-alone motor IEC flange-mounted motor with bore holes IEC flange motor with threads General flange-mounted motor (other than IEC) 7 series integral gearmotor with IEC feet, with specification of shaft height if required IEC flange-mounted motor with bore holes and IEC feet, with specification of shaft height IEC flange-mounted motor with thread and IEC feet, with specification of shaft height if required General flange-mounted motor (other than IEC) with feet, with specification of shaft height if required C-face flange-mounted motor, dimensions in inch MOT1 AC Motors
for the DR. motor series Output types of the motors Foot-mounted motor Unit designation /FI SEW motor with IEC feet and A endshield 1 3 7 series gearmotor Unit designation The /FI foot-mounted motor is designed as a motor with a shaft end and feet to IEC specifications. The shaft and feet dimensions for -pole motors are based on the power rating of the DRS motor. Different feet and shaft dimensions are available for motors with efficiency rating requirements (DRE, DRP). According to EN5037, each power rating is assigned the corresponding shaft height. Some DR motors allow for implementing a higher power rating in a smaller size (e.g. DRS100LC with kw). If an application requires the EN compliant shaft height, the motor can be equipped with another foot height instead. If the power assigned to the motor differs from EN5037, the shaft height will be indicated in the unit designation. For example: DRS100LC/FI11M. /FG Motors for gear unit mounting Motors sold as stand-alone motor with preparation for mounting to a gear unit are assigned the designation /FG. This designation is eliminated if the motor is mounted together with the gear unit (as conventional gearmotor). The /FG flange mounted motor is the gear unit mounting version of the motor. The flange dimensions are implemented according to the SEW work standards for gear unit mounting. The pinion shaft end is dimensioned according to the motor power rating. It is therefore possible that DRS, DRE and DRP motors have different pinion shaft ends within one motor size and length. 5 6 7 8 9 10 11 1 13 1 15 16 IEC flange-mounted motor with boreholes Unit designation /FF IEC flange-mounted motor with bores 17 18 The design /FF is a variant with through bores in the flange, comparable to IEC type of construction B5. The flange dimensions for -pole motors with Standard Efficiency (DRS), High Efficiency (DRE) or Premium Efficiency (DRP) are according to the standard and based on the power rating. Flange combinations deviating from the standard are given the unit designation /FL (see below). If the motor size deviates from the standard, the flange size is added accordingly: e.g.: DRS90L/FF100M 19 0 1 MOT1 AC Motors 5
for the DR. motor series IEC flange-mounted motor with threads Unit designation /FT IEC flange motor with threads This type is for example comparable with the IEC type B1. The flange dimensions for shaft dimensions of -pole motors with standard efficiency level (DRS) are designed according to the standard EN 50 37 001. Other shaft dimensions are available for energy-efficient motors or for power enhanced motors with copper rotor. Flange-mounted motor (deviating from IEC) Unit designation /FL Flange-mounted motor with dimensions deviating from IEC This flange-mounted motor is a motor variant deviating from IEC. The /FL option enables the customer to choose an IEC flange that does not correspond to the power assigned to the motor (see IEC standard flange assignment /FF). The shaft collar is not necessarily at the same level as the flange bolt surface. "C-face" flange-mounted motor Unit designation /FC The "C-face" flange-mounted motor is a motor type with tapped holes in the flanged end shield similar to an FT type (B1). The flange and shaft dimensions for -pole motors level are designed in compliance with the NEMA standard (in inches). 7 series gearmotor with feet Unit designation /FM Integral motor on 7 series with feet Only motors sold as stand-alone motors with preparation for being mounted to a gear unit are assigned the designation /FM. This designation is eliminated if the motor is mounted together with the gear unit. /FM is the gear unit mounting version of the motor with feet. It is the combination of the options /FG and /FI. The flange dimensions are implemented according to the SEW work standards for gear unit mounting. The pinion shaft end is dimensioned according to the motor power rating. It is therefore possible that DRS, DRE and DRP motors have different pinion shaft ends within one motor size and length. 6 MOT1 AC Motors
for the DR. motor series Foot-/flange-mounted motor Unit designation /FE Motor with flange, bores and feet according to IEC 1 The foot- and flange-mounted motor is an IEC variant of the motor and is, for example, comparable with the IEC type B35. The foot and flange dimensions for -pole motors with Standard Efficiency (DRS), High Efficiency (DRE) or Premium Efficiency (DRP) are based on the power rating according to the standard. 3 5 IEC flange-mounted motor with threads and feet Unit designation /FY Motor with flange, threads and feet according to IEC 6 7 The foot- and flange-mounted motor is an IEC variant of the motor and is, for example, comparable with the IEC type B3. The foot and flange dimensions for -pole motors with Standard Efficiency (DRS), High Efficiency (DRE) or Premium Efficiency (DRP) are based on the power rating according to the standard. 8 9 10 11 1 13 1 15 16 17 18 19 0 1 MOT1 AC Motors 7
for the DR. motor series Mechanical attachments BE.. HR HF /RS Spring-loaded brake with specification of size Manual brake release of the brake, automatic disengaging function Manual brake release, lockable Backstop /MSW MOVI-SWITCH /MI Motor identification module for MOVIMOT /MM03 - MM0 MOVIMOT /MO MOVIMOT option(s) Temperature sensor/temperature detection /TF /TH /KY /PT Temperature sensor (positive coefficient thermistor or PTC resistor) Thermostat (bimetallic switch) One KTY8-130 sensor One / three PT100 sensor(s) For detailed information, refer to page 300. Encoder /ES7S /EG7S /EH7S /EV7S /ES7R /EG7R /EH7R /EI7C /EI76 /EI7 /EI71 /AS7W /AG7W /AS7Y /AG7Y /AH7Y /ES7A/EG7A /XV.A /XV.. Mounted speed sensor with sin/cos interface Mounted speed sensor with TTL (RS-) interface, V = 9-6 V Mounted speed sensor with HTL interface Mounted speed sensor with HTL interface and 6 / / 1 period(s) Mounted absolute encoder, RS-85 interface (multi-turn) Mounted absolute encoder, SSI interface (multi-turn) Mounting adapter for encoders from the SEW portfolio Mounting adapter for non-sew encoders Mounted non-sew encoders For detailed information, refer to page 85. 8 MOT1 AC Motors
for the DR. motor series Connection variants Ventilation Bearing /IS /ASB. /ACB. /AMB. /ABB. /ADB. /AKB. /ASE. /ACE. /AME. /ABE. /ADE. /AKE. /KCC /KC1 For detailed information, refer to page 305. For detailed information, refer to page 311. For detailed information, refer to page 3. Integrated plug connector HAN 10ES plug connector on terminal box with two-clamp closure (cage clamps on motor end) HAN 10E plug connector on terminal box with two-clamp closure (crimp contacts on motor end) HAN Modular 10B plug connector on terminal box with twoclamp closure (crimp contacts on motor end) HAN 10ES plug connector on terminal box with single-clamp closure (cage clamps on motor end) HAN 10ES plug connector on terminal box with single-clamp closure (crimp contacts on motor end) HAN Modular 10B plug connector on terminal box with singleclamp closure (crimp contacts on motor end) Terminal strip with cage clamps (for DR.71 - DR.13) C1 profile compliant connection of the DR80 overhead trolley drive (VDI guideline 363) (for DR71, 80) /V Forced cooling fan /Z Additional inertia (flywheel fan) /AL Metal fan /U Non-ventilated (without fan) TENV /OL Non-ventilated (closed B side) TENV /C Protection canopy for the fan guard /LF Air filter /LN Low-noise fan guard (for DR.71 13) /NS /ERF /NIB Relubrication device (for DR.315 only) Reinforced bearing A-side with roller bearing (for DR.315 only) Insulated bearing B-side (for DR.315 only) 1 3 5 6 7 8 9 10 11 1 13 1 15 16 17 18 19 0 1 MOT1 AC Motors 9
for the DR. motor series Condition monitoring /DUB /DUV Diagnostic unit brake = brake monitoring Diagnostic unit vibration = vibration sensor For detailed information about /DUB refer to page 81, zu, and for /DUV refer to page 319. Other additional features /DH Condensation drain hole /RI Reinforced winding insulation /W Second shaft end on the motor/brakemotor For detailed information, refer to page 3. 30 MOT1 AC Motors
Serial number. Serial number 87. 113. 09. 09. 003 Multiple unit identifier (3 digits) Year shipped ( digit) Year ordered ( digits) Order number (7 digits) Sales organization 1 3 5 6 7 8 9 10 11 1 13 1 15 16 17 18 19 0 1 MOT1 AC Motors 31
Examples for the unit designation of DR series AC motors.3 Examples for the unit designation of DR series AC motors Motor variant Unit designation of the motor variant AC motor series Series DR Unit designation S E P Size 71 80 90 100 11 13 160 180 00 5 315 Length S M L MC LC Number of poles 6 8/ 8/ Output flange design Output design /FF /FG /FM /FI* /FT /FC /FE* /FY* /FL /FK* *= shaft height Mechanical attachments Brake - BE05 BE1 BE BE5 BE11 BE0 BE30 BE3 BE10 BE1 Manual brake release - HF HR Backstop - /RS Decentralized installation - /MI /MO /MSW /MM03 /MM05 /MM07 /MM11 /MM15 /MM /MM30 /MM0 Temperature sensor/temperature detection Temperatures detection - Thermal motor protection - /KT /TF /PT /TH Encoders Encoder - /ES7. /EG7. /EH7. /EV7. /AS7. /AG7. /AH7. /XV.. Built-in encoder - /EI7C /EI76 /EI7 /EI71 3 MOT1 AC Motors
Examples for the unit designation of DR series AC motors Motor variant Unit designation of the motor variant Connection alternatives 1 Connection alternatives - /IS /AB.. /AC.. Fan /AD.. /AK.. /AM.. /AS.. /KCC /KC1 3 Forced cooling fan - /V Fan - Fan guard - /C /Z /AL /LF /U /OL 5 Low noise fan guard - Higher overhung load (only 315) - /ERF /LN Bearing 6 7 Relubrication (only 315) - /NS 8 Insulated bearing (only 315) - /NIB Condition monitoring 9 Brake monitoring /DUB /DUV 10 Condensation hole - /DH Other additional features 11 Reinforced winding insulation - /RI 1. shaft end - /W 13 1 15 16 17 18 19 0 1 MOT1 AC Motors 33