Access Interlock with Safety Switch User Manual - Original Language Version

Similar documents
Access Interlock with Safety Switch User Manual - Original Language Version

Dual Key Access Interlock with Safety Switch User Manual - Original Language Version

Bolt Interlock with Safety Switch User Manual - Original Language Version

Multi Key Bolt Interlock with Safety Switch User Manual - Original Language Version

Multi Key Powersafe Electrical Switch User Manual - Original Language Version

KSS Solenoid Controlled Switch

Multi Key Solenoid Controlled Switch User Manual - Original Language Version

Dual Key Claw Interlock User Manual - Original Language Version

KSUPS + Solenoid Controlled Switch

Sliding Door Interlock User Manual - Original Language Version

Motion Sensing Interlock User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Motion Sensing Interlock User Manual - Original Language Version

Modular Ball Valve Interlock User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Peristaltic Cased Tube Pumps

Sense7-series Non-contact coded safety switch

Data Sheet. AmLok.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

DMR & DMSR. Product Data Sheet. Modular Door Lock with Rotary Switch. Description

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

D4BS CSM_D4BS_DS_E_8_4

Technical Data. Dimensions

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

BMRX Series ROTARY LEVEL CONTROL

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

Swaging Machine Type H32B4

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

IMPORTANT SAFETY NOTICE

Actuator (DM-F Shown) DM1-CLIN-F

EStrong-series Emergency Stop

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

CAUTION CM-SE CM-S21 CM-S41

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

NHP SAFETY REFERENCE GUIDE

RELAY BOX PRODUCT MANUAL IMPORTANT

UNDER VEHICLE ACCESS SAFETY

MKey9-series Safety Interlock Switch with Guard Locking

Installation and Operating Instructions

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

CBS 1035 CAPSTAN WINCH

Prevents Unscheduled Truck Departures

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Installation and Operating Instructions

CE Operating and Maintenance Manual

OPERATING INSTRUCTIONS

Hinge Wing Safety Interlock Switches

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

RELIANT HOLDINGS LTD AND ITS AFFILIATES Safety Management System. Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 5

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

1329I Integrated Drive/Motor CE Filter Option Kit

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

Electrically Released Brakes ERS VAR10 SZ 5000/5000

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Single Phase Electronic Speed Controllers

Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Safety switches with solenoid and separate actuator

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

D o o r I n t e r l o c k s

Safety switches with solenoid and separate actuator

PLS / WPLS / PLV / PLS-HP / PLF-HP PLN / WPLN / WGN / PLFN PSN / PSFN PLE / WPLE / PLFE PLPE / WPLPE / PLHE

SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Continuous, Prime, Standby, Mission Critical

TC26-B Vehicle Sensor

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Element C8.3 Installation, Use and Inspection of Electrical Systems

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

INDUSTRIAL SPRING REELS

SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

Square Inline Fans with Multi-Directional Discharge

DRAFT COPY, NOT FOR DISTRIBUTION

BMRX Series Rotary Level Indicator

CONSTRUCTION FEATURES AND OPTIONS

Appendix: Safety and application notes for... 15

Safety switches with separate actuator

3 - Protection components Motor circuit-breakers

Operating Instructions

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Mixed Flow Inline Fan, Model MFSI

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Safety Interlock Switches

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

General_technical_data Series

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

4TCH Submersible Pumps. Installation and Operating Manual

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Transcription:

-FSS-KF-2 The or HERCULES is a single key access interlock complete with electrical contacts for use on hinged and sliding doors. The Hercules contacts can be used to switch off the machine via its control circuitry or to initialize a signal to visual beacons/ sounders. The switch is sealed to IP65 with, 1N/O 2N/C contacts, rated to 6 amps making it ideal for use in cross monitored safety systems. The interlock is manufactured in a durable stainless steel making it ideal for use in harsh or corrosive environments and where the lock is subject to heavy use. Operation The Hercules is used for machine isolation in order to protect the hazardous area from access while power is on. (Hercules) access interlock with safety switch: bolt trapped - key trapped condition 1 Power is on, sidebolt is trapped 2 Turn and release key, to change 3 and key is trapped the switch contact condition and turn and release the bolt Power is off, bolt is free and key is free 1. While the power in the hazardous area is on, the sidebolt of the is trapped in the mechanism. The door is locked and the key is trapped. 2. By turning and releasing the key, the contact condition changes switching the power off. The bolt can now be released. The key should be kept by the personnel as long as the door is opened, ensuring the power cannot be turned on. 3. With the sidebolt and key released, the switch condition cannot be reversed. (Hercules) access interlock with safety switch: bolt trapped - key free condition 1 Power is on, sidebolt is trapped 2 Insert and turn the key, to change 3 and key is free the switch contact condition and release the bolt Power is off, bolt is free and key is trapped 1. While the power in the hazardous area is on, the sidebolt of the is trapped in the mechanism. The door is locked and the key is free. 2. By inserting and turning the key, the contact condition changes switching the power off. The bolt can now be released. This will trap the key. 3. With the sidebolt released and key trapped, the switch condition cannot be reversed. U--001-E Issue 1 1 of 6

Usage The access interlock with safety switch is designed to be part of a safety system and is used to isolate the power which is then allows to gain access to a hazardous area. The access interlock is not designed for security purposes. Installation The housing of the access interlock with safety switch should normally be mounted on the static frame of the guard and the bolt to the sliding or hinged door using suitable fasteners. Fixed bolt bracket is highly tolerant to misaligned guards and should be fitted with suitable fasteners. Please refer to the drawing on page 4 for hole and mounting details. The interlocks are avalable in Hand 1 and Hand 2 version suitable for left or right hinged doors, respectively. Anti vibration pads should be used on machines that generate a high level of vibration IMPORTANT: The access interlock should be mounted on the guard using anti-tamper fasteners to prevent unauthorised removal. The access interlock must be installed by a competent and qualified person who has read and understood these instructions. Please retain this document in your technical file. Force required to shear lock bolt is 24KN. Maintenance Periodic visual checks should be carried out by the site manager / safety officer. Do not lubricate lock barrel with oil or grease, use CK Dry Powder Graphite if necessary. In case of defects being detected please contact your nearest Castell Support Department for further actions. Please see Contact section for contact details. U--001-E Issue 1 2 of 6

Technical Data Temperature rating Type of mounting Weight Material Power isolation Motor Isolation (AC Values) Switch approvals MTTF Certification Ambient temperature of stages: open at 100% lu/lth - 55 C during 24 hours with peaks up to 60 C, enclosed at 100% lthe - 35 C during 24 hours with peaks up to 40 C Storage temperature: -40 C to 85 C (in case temperature below -5 C no shock load permissible) Surface mount using suitable fasteners (see drawing on page 4 for mounting details) 2,5 kg Stainless steel 10A 400V AC CE, UL, CSA, IP65 Available on request Application The Castell Hercules () access interlock with safety switch is used as apart of a safety system, typically in machine guarding applications. The removal of the key from the, isolates the electrical supply to the machine and allows the removal of the sidebolt. Therefore the guard can only be opened when the electrical supply has been switched into a safe condition. This key is then taken into the area by the operative to safeguard against accidental lock in or start up or to initialize another part of the process, i.e. switching the machine into a teach mode. The machine cannot be restarted until the door is closed, the bolt is trapped in the access interlock and the key is replaced. EC-Declaration Hercules: access interlock with safety switch We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential health and safety requirements applying to them. Empowered signatory: Mr T.C. Whelan Managing Director U--001-E Issue 1 3 of 6

Drawing Dimensions: in mm Note: For safe mounting, use security screws, Hand 1, key free - bolt trapped, Hand 2, key free - bolt trapped U--001-E Issue 1 4 of 6

Wiring Diagram 2 NC/1NO Contacts as shown in the following positions: Key Bolt Version 1 - KF FREE TRAPPED Version 2 - KT TRAPPED TRAPPED U--001-E Issue 1 5 of 6

Order Information Product Type 1 2 3 4 Part Number - - - Example - FS S - KT - 1 5 ABC 1 Lock portion type FS (1) / Q (1) 2 Material S = Stainless steel (standard) 3 Condition (by bolt trapped) 4 Handing KT = key trapped while bolt trapped KF = key free while bolt trapped 1 = left hinged door (bolt enters left) (2) 2 = right hinged door (bolt enters right) (2) 5 Lock portion symbol FS (1) up to 3 characters / Q (1) up to 6 characters (1) FS - Lock type Q - Lock type Up to 3 characters Up to 6 characters (2) Handing 1 2 Accessories Special construction available upon enquiry Product Part number Flip Cap FLIP-S Contact Information U--001-E Issue 1 6 of 6