Gewässer Umwelt Schutz

Similar documents
User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Instruction Manual. Sewage lifting station compli 300

Condensate Drain Valve AK 45. Original Installation Instructions English

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Ball valve for pipeline systems

Assembly and Maintenance Manual Type ASNU

Installation Instructions for Load Management Kit A051C329

Starting up hydraulic systems

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Swing Piston Compressors and Vacuum Pumps

Assembly and operating Instructions. Bypass Flow Meter DST

Pan and Tilt Head CDD2416-T

HST -LS Interlocking device (Translation of Original Manual)

Exchange of rollers from the XTS-Mover

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Assembly and Maintenance Manual Type AS

Operating Instructions

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Angle seat valve with diaphragm actuator VZXA-...-M

Pressure relief valve

Assembly and Maintenance Manual Type RSBW

Operating & Maintenance Manual For Steam Conditioning Valve

After Sales & Service. IST METZ GmbH

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Technical Documentation

ACTIVAL Two-way Ball Valve with Threaded-end Connection

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

CO01 Radiator Assembly

1200W INVERTER GENERATOR

Operating instructions

Declaration of Conformity as per Directive 97/23/EC

Operating Instructions for Elevator Buffers type LP

Installation, Operation, and Maintenance Manual

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Important instructions

FU01 Tank Assembly. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

2014 Volkswagen Golf

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

These installation and maintenance instructions must be read in full and completely understood before the installation!

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

RESOL SBS 1000 * * Connection Operation

Installation Instructions. Ultimate Screen. English Version 2.3

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Tank Foam Generator OPERATION AND MAINTENANCE

Installation manual wall-mounted distributor

USE AND MAINTENANCE MANUAL

Angle seat valve with piston actuator VZXA-...-K

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

Instruction Manual. Maximum Operating Pressure 510 bar

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operating Instructions

Flue Gas Analyzer IMR 1100F

JUNG PUMPEN BAUFIX 200. Instruction Manual

Operating instructions

OPERATING MANUAL 18V Ni-Cd Battery Pack

Type 6213 EV, 6281 EV

Assembly and Operating Manual Membrane-Controlled Siphon Safety Device Type HS-F - Fixed Height Type HS-V - Adjustable Height

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

Spare Parts List Return line filter RF

USE AND INSTALLATION HANDBOOK

Owner s Information Manual

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Breezair TBA 550 Installation Manual

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating Instructions

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Tina 4A Connection block

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

Installation Guide perma STAR VARIO

Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

P239-1 Supply Pumper Instructions

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

ELITE SERIES R-410A Ready - Multi-Position

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

1100W PORTABLE GENERATOR

Installation and Operation Manual

User Manual dpette+ Electronic Pipette 2016-ver.1

Level Measuring Sensor for Diesel Fuel Tanks

Installation Instructions **THIS RAIL MOUNTING KIT USES 11 BOLTS**

Adjustable Speaker Mount GRAVIS 8

Flash Point Process Analyzer

Adjustable Speaker Mount GRAVIS 12

ProMinent. Operating Instructions Turbine Meter turbodos

Spare parts list Inline filter FLND switchable

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Hydronic Corporation

Transcription:

The qualification of the system has been proven by TÜV Rheinland. Gewässer Umwelt Schutz GmbH GGW Glycol protector Assembly instructions

2 Foreword Always study this assembly instruction manual before installation and initial operation. This assembly instruction manual is part of the protector and should be stored close to the device. We reserve the right to amend this document. Any liabiliy for errors and misprints of this document is excluded. November 2017 Content 3 Product overview 4 Notes on safety 6 Contents of delivery - GGW Glycol protector 7 Assembly instructions for - GGW Gylcol protector 14 Circuit diagram of GGW Glycol protector switch box/control module 15 Connection plan 16 Service & maintenance, warning notices and leakages Ölprotektor.de

GGW Glycol protector - Assembly instructions Product overview Special sizes: GGW Glycol protector, according to your requirements Accessory options: Leaf protection grating Heating kit with heating mats and heating thermostat (Heating requirements) for operation of heat pump Sensor for second circuit Platform to be set up in GGW Glycol protector Fault indicating module (via SMS, Fax oder E-Mail) Material: stainless 1.4301 in 1,5 mm or aluminum AlMg3 Process: welding according DIN EN ISO 9606-1 2.0 3

4 Notes on safety Always read the manual before initial operation. It contains vital and important tips and references to avert danger to people as well as equipment. Disregarding the operating manual can lead to endangerment of individuals, the environment and damage to the unit. We reject liability for neglectful operation. Please note: Keep this manual in close proximity to the unit. Setup and assembly of GGW Gylcol protector and compoments to be carried out by qualified professionals only. Setup, connection and operation of GGW Gylcol protector and components to be operated for its intended purpose according to this instruction as well as in accordance with local rules and regulations. The condensation pan must be earthed. Alterations and modifications to our product and its components are prohibited and can lead to failure or malfunction. Do not operate GGW Gycol protector and components in areas with a high risk of damage. Specified minimum clearances are to be observed. Safe operation of Protector and components can only be guaranteed for properly assembled devices and use as intended by the manu- facturer. Safety systems may not be modified or bypassed. Do not operate damaged or faulty GGW Glycol protectors or components. Protectors and components require a minimum clearance to flamm- able, explosives, combustibles, aggressive substances or environments. Assembly, repair and service only to be carried out by autho- rised qualified professionals. Visual inspection and cleaning may be carried out by operator. Appropriate measures to be taken to avert danger to individuals while assembling, repairing, servicing or cleaning GGW Gycol protector. Ölprotektor.de

GGW Glycol protector - Assembly instructions 5 Recycling Disposal and packaging All products are carefully packaged to withstand transport damage. Please recycle all packaging material according to your countries waste management guidelines. Warranty Warranty conditions are outlined in our Allgemeine Geschäfts- und Lieferbedingungen (General terms and conditions). Please contact your local Distributor. Description The handling of material endangering water resources is regulated in the Federal water act and the German Anlagenverordnung (AwSV). Our GGW Glycol protector is manufactured from high grade stainless steel and is in full compliance with those regulations. GGW Glycol protector with its integrated oil separator is designed to withstand the most extreme precipitation events ever recorded in Germany. It will safely drain the liquids away withouth spilling, thereby preventing overflow. In the event of leakage, escaping oil and glycol (water hazard class one till three, according to legal requirements) will be prevented from escaping to the surrounding environment.

6 Contents of delivery GGW Glycol protector connecting screws ½", 3 per connection level screw nut ½, 3 per connection level Assembly parts for pan according to drawing Note: washer, 6 per connection level Check delivery for completeness 1 safety valve with actuator 1 switch box (control module) 1 pressure sensor ½" (incl. 5 m cable) 1 protective cover with 3 screws per safety valvel platforms, either standard or made to your requirements Ölprotektor.de

GGW Glycol protector - Assembly instructions 7 Installation instruction GGW Glycol protector When choosing the appropriate size make sure all water hazarduous components can be fitted within the GGW Glycol protector. Make sure the oil separator is not covered by the unit and rain water can reach the pan. Ensure a supporting structure able to support the weight of the 1.5 mm stainless steel device without deformation. Note: Installation to be carried out by 2 personnel. More complicated structures will be accompanied by a drawing. Make sure to align pan properly, resting firmly on the supporting structure. Alignment The supporting structure is to be aligned horizontally using a spirit level to ensure proper operation. Clean all surfaces before levelling.

8 Align first part of pan vertically with outer edge of supporting structure. Assembling the pans is illustrated in drawings. Note position of separators. upended side Assembly Place second part of pan into first part as per drawing. Follow the same procedure with remaining parts. Make sure not to bend material. Ölprotektor.de

GGW Glycol protector - Assembly instructions 9 Note: Make sure pan is resting firmly on supporting structure and oberserve drying time of loctite. Connecting Connect all parts with connecting screws. Use loctite to secure threads. Place washer onto thread and put screw through drilled hole. Put second washer onto protruding thread. Add more loctite and tighten screw nut by hand. Use same routine for remaining screws. Use appropriate tool to tighten screws, achieving a watertight connection.

10 Platform Apply an oil and water repellant sealing compound to the underside of the platform (e.g. Silicone). Position platform in protector. Observe drawing. Seal exterior of platform with oil and water repellent material (e.g. Silicone) Hinweis: If the pan is accidently damaged when drilling, perform a pressure test for 24 hours to ensure leak tightness. Fastening silicone seam Make sure to connect the device with the platform and the separator to the supporting structure. Be aware that perforation can lead to leakage problems. We recommend a construction surrounding the pan. If you have to drill make sure to seal the hole properly. We can provide information on different fastening methods. Pressure sensor test port The cold water circuit needs to have a ½" interrnal threaded connection for the pressure sensor. Make sure the test port can be isolated from the circuit so you can replace the pressure sensor without having to drain the system. incl. 5 m cable Ölprotektor.de

GGW Glycol protector - Assembly instructions 11 We can supply you with a copper adapter which includes a Schrader-Valve to be soldered into place. Please take note to remove the Schrader-Valve during soldering. Screw pressure sensor onto existing or newly attached test port. Pressure sensor to be tightened with max 30 NM to avoid damage. When connecting the pressure sensor, refer to connection diagramm (Page 14). A 5 m cable is included with the pressure sensor for ½" thread-connection. Position the two wires according to connection plan. Safety valve with actuator Choose one of three actuator positions on valve body. Positioning of actuator determines position of pan. When installing the valve observe direction of flow indicated by arrow on valve. Screw valve onto welded cone at drainage point of GGW Glycol protector. To allow condensation to be drained, a second ¾" connection can be used. Make sure to provide a bleeding function, thereby eliminating the risk of the separator running dry. Electrical connections to be made according to connection plan. A cover is provided for every valve. Make sure to install it when running the device in an outside area.

12 Switch box / controle module pressure sensor platform protective cover (per safety valve) switch box (controle module) The control module is monitoring the Glycol pressure. It is fitted with a push-button to check operation. Pressure fluctuations are monitored and assessed. The valve will be closed in case of leakage. The red signal indicates the current pressure. Correct operation is indicated by a green Druck sign. The LED display ticker Druckabfall indicates a leak. The green push-button will close the valves for an operational check. Ölprotektor.de

GGW Glycol protector - Assembly instructions 13 Operation Different levels of configuration are accessed via key combinations. The User-level is sufficient for device operation. All other configuration levels are secured with a PIN. Activate User-level by pushing PGM-Key twice. Arrow-key will move cursor to parameter to be adjusted. Parameters available: DRUCK (Pressure): Operating pressure Note: Warning! An alert will be send to GLT when valves are completely closed. The control module requires a 230V supply. Follow connection plan. Choose the parameter using the arrow keys. Press PGM key to activate and change settings with the arrow keys. This setting will be saved automatically after ten seconds. Pressing the PGM key will fast track the procedure. DRUCK (Pressure) is the consigned operating pressure. All pressure alarms have to be reset. A reset is only possible once correct operating pressure has been restored. Press F / Exit - key for two seconds Ventilsignal (Valve signal) appears in Display. A defect valve will also trigger Ventilsignal in Display. The system distinguishes between Gylcol protector errors and errors triggered by loss of pressure.

14 Circuit diagram of GGW Glycol protectorswitch box / control module PE N L1 terminal row 1 1 terminal row 3 2 3 4 5 optional on number x expandable contact ¾ 0-10 bar 3mA 6 7 8 9 <85 % open S5 S11 S4 10 11 12 terminal row 2 optional on number x expandable contact ½ <10 % open S3 S1 S3 S1 13 alarm contact 14 15 potential free 16 17 18 Optional on number x expandable 19 terminal row 1 20 S1E 21 22 23 24 25 26 27 28 29 30 Ölprotektor.de

GGW Glycol protector - Assembly instructions 15 Connection plan Note: Make sure the display is clearly visible when mounting the control module. For any questions regarding assembly, implementation or service please contact our service telephone at: +49 5921 71347-0. Recommendations for cable routing:: Supply cable for switch box: NXM 3x1.5² Control cable for pressure sensor switch box: Olflex 2x0.75² (shielded) Supply cable for valve switch box: Olflex 2x1.5² Control cable for valve switch box: Olflex 4x1.5² UV-resistant if exposed to sun light Connection Voltage supply switch box (1.5 mm²) Ph, terminal L 1 N, blue terminal strip Ph, green terminal strip Connect pressure sensor, (0.8 mm²) Terminal block switch box, terminal block pressure sensor Terminal 7 = terminal 1 (white) Terminal 8 = terminal 2 (brown) Connecting valves (1.5 mm²) Terminal block switch box, terminal block valves Terminal 17 = terminal 1 (brown) Terminal 23 = terminal 2 (blue) Terminal 11 = terminal S4 (4) Terminal 12 = terminal S5 (5) Terminal 13 = terminal S1 (1) Terminal 14 = terminal S3 (3)

16 Service & maintenance, warning notes und leakage Service & maintenance When servicing the unit in regular intervalls, always check and clean the GGW Glycol protector. Leaves and other contaminants can compromise the oil separator s performance. The oil separator can be rinsed via the water drainage. Within the scope of the maintenance, please press the green button for the control of the valve for 10 seconds in order to remove deposits in the valve and to check the functioning of the fault signaling device. If there are any water-polluting substances in the GGW Glycol protector you have to shut down the system immediately and inform your refrigeration and climate expert. The water-polluting substances are to be disposed of professionally. Warning notes Please note that different detergents dissolve oil in water. The GGW glycol protector must be rinsed with water until no detergent is left in the GGW glycol protector if such cleaning has been used. Avoid bi-metal corrosion by keeping other metal parts separate from GGW Glycol protector. Ölprotektor.de

GGW Glycol protector - Assembly instructions 17 Leakage, Check the GGW glycol protector if a leakage is detected. Collected water of the GGW glycol protector must be disposed properly. For this purpose a ¾" connection can be screwed on the drain and the process can be opened by acknowledging the error message. Alternative: Open the valve manually with the supplied manual drive. Note: For any questions regarding assembly, implementation or service please contact our service telephone at: +49 5921 71347-0.

18 Ölprotektor.de

GGW Glycol protector - Assembly instructions 19

Gewässer Umwelt Schutz GmbH Lise-Meitner-Straße 14 D-48529 Nordhorn T: +49 5921 71347-0 F: +49 5921 71347-29 info@oelprotektor.de Ölprotektor.de