SECTION LIFT ARM PARKING GATES

Similar documents
A. This Section includes the following types of sectional overhead doors:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION ENCLOSED CONTROLLERS

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

PROJ. NO SECTION HYDRONIC PUMPS

SECTION [ ] SECURITY GRILLES. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] HIGH PERFORMANCE OVERHEAD HIGH SPEED DOORS. Display hidden notes to specifier. (Don't know how?

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

SECTION RAPIDVIEW MODEL 999. Copyright ARCAT, Inc. All rights reserved

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

** NOTE TO SPECIFIER ** Overhead Door Corporation; High performance overhead coiling door products.

IN2 Enclosed Switches and Circuit Breakers

SECTION AXIAL HVAC FANS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SECTION HIGH PERFORMANCE OVERHEAD COILING DOORS

SECTION OVERHEAD COILING DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

AUTOMATIC ENTRANCES SLIDING GILDOR, INC. SECTION [08460] MODEL SLM SERIES TYPE COM

SECTION HIGH PERFORMANCE OVERHEAD COILING DOORS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

SECTION HIGH PERFORMANCE OVERHEAD COILING DOORS

SECTION CENTRIFUGAL HVAC FANS

INSTALLATION M ANUAL

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

SECTION VistaGard ROLLING GRILLES CLEAR PANEL DESIGN

SECTION HIGH-SPEED ROLLING DOORS. B. Wiring from electric circuit disconnect to operator to control station.

FREE STANDING WORK STATION JIB CRANE

1. Wiring Diagrams: Power, signal, and control wiring.

MODEL D-SBG Single Arm Barrier Gate Operator

SECTION DUCTWORK ACCESSORIES

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

University of Delaware

CEILING MOUNTED WORK STATION STEEL BRIDGE CRANE

Guide Specification SECTION VINYL WINDOWS

R. Manually Operated: Standard closure to be manually operated push up, pull down with removable retrieval rod as standard. The effort to raise or low

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC

SOUND-RETARDANT- VERTICAL LIFT DOORS

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SteelForm S-24C SECTIONAL OVERHEAD DOORS

Intelli-Park Series Barrier Arms. Intelli-Park 9. Intelli-Park 14. Intelli-Park 18. Intelli-Park 32

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

5. Contractor Information 3M Model 2300 Series System Layout Checklist

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

Parking Control Equipment Vehicle Fare Collection Roadway Construction Roadway Equipment

MODEL D-WBG Wishbone Arm Barrier Gate Operator

SECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.

National Reach. Local Service.

Ice Rink Renovation & New Clubhouse

9900 SERIES SECTION LECTURE ROOM SEATING & TABLET ARM SPECIFICATIONS

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

(1032 mm) 30.5 (775 mm) 44 ( mm)

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION MOTOR CONTROL

F. VAV hoods shall have a restricted bypass plate.

SECTION COILING DOORS AND GRILLES

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage

A NEW GENERATION OF DOORS FOR TEMPERATURE CONTROLLED ENVIRONMENTS

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS

SECTION ROLLER WINDOW SHADES

Heavy Duty Commercial Linear Gate Operator

BARRY BARRIER GATE AUTOMATION

SECTION ROLLING SERVICE DOORS

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

SECTION METAL ATHLETIC SPORT LOCKERS

SECTION FACILITY FUEL OIL PIPING

Installation Instructions

SKC400U SLIDING GATE OPENER OWNER S MANUAL

UL (9050, 9100, 9150) PG. 10 PG.

PART 1 GENERAL. Pfannenberg Inc.

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16" x 2 3/16" x 10 Ga. 12" 15.5" 1 1/2" x 1 1/2" x 12 Ga.

Installation/Owner s Manual 1603

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

Installation/Owner s Manual 1601 / 1602

SECTION ROLLING SERVICE DOORS

Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at

MODEL WBG WISHBONE BARRIER GATE OPERATOR

MST. Full Height Turnstiles. alvaradomfg.com

East Central College

VALVES, FIRE HYDRANTS, AND APPURTENANCES

SECTION WELDING FUME EXHAUST SYSTEM

SPECIFICATIONS - DETAILED PROVISIONS Section Valve and Gate Operations CONTENTS

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Heavy Duty Commercial Linear Gate Operator

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

SECTION METERS AND GAGES FOR HVAC PIPING

SECTION HVAC POWER VENTILATORS

Transcription:

St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 SECTION 11 12 33.13 LIFT ARM PARKING GATES PART 1 - GENERAL 1.01 SUMMARY A. Section includes lift arm parking gates. B. Related Sections include Division 01 Section Alternates for Schedule of Alternates affecting Work of this Section. 1.02 PREINSTALLATION MEETINGS A. Preinstallation Conference: Conduct conference at Project site. 1. Inspect and discuss electrical roughing-in, equipment bases, and other preparatory work specified elsewhere. 1.03 ACTION SUBMITTALS A. Product Data: For each type of product. B. Shop Drawings: For parking control equipment. 1. Include plans, elevations, sections, details, and attachments to other work. 2. Include diagrams for power, signal, and control wiring. 3. Vehicle Detectors: Layout and method of placement of vehicle loop detector system. 1.04 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For lift arm gates to include in emergency, operation, and maintenance manuals. PART 2 - PRODUCTS 2.01 LIFT ARM GATES A. General: Provide lift arm gate consisting of operator and controller housed in a weathertight, tamper-resistant cabinet enclosure with gate arm. Device shall be activated by a signal from access device. Fabricate unit with gate-arm height in down position of not more than 35 inches above pavement. B. Standards: ASTM F 2200 for barrier gates and gate operators that are listed and labeled according to UL 325 by a qualified testing agency. LIFT ARM PARKING GATES 11 12 33.13-1

St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 C. Controller: Factory-sealed, solid-state, plug-in type, with galvanized-steel box for wiring connections. 1. Type: Noncommunicating. a. Separate momentary contacts for vehicle entries and vehicle exits. 2. Physical Characteristics: a. On-off power supply switch. b. Automatic-manual switch. c. Thermal-overload protection with manual reset. d. Plug-in connectors for two vehicle loop detectors. e. Switch to test motor and limit switches. f. Emergency manual disconnect. g. Single, 115-V ac grounded power receptacle. 3. Operational Characteristics: a. Automatic instant-reversing obstacle detector mechanism that stops downward motion of gate arm if arm contacts or nears an object and that immediately returns arm to upward position. Include a zero- to 60-second, variable-time reset device. b. Broken gate-arm monitoring. c. Diagnostic mode for on-site testing, with LEDs for inputs and outputs. d. Reversible arm capability for right- or left-handed operation. D. Cabinets: Fabricated from sheet metal with seams welded and ground smooth; approximately 15 inches square by 40 inches tall. Provide single, gasketed access door for each cabinet with flushmounted locks. Furnish two keys for each lock. Fabricate cabinet with internal reinforcing and four mounting holes accessible only from inside cabinet. 1. Steel Sheet: Not less than 0.097-inch-thick, galvanized- steel sheet. a. Finish cabinet, interior and exterior, with manufacturer's standard white baked-enamel or powder-coat finish. E. Straight Gate Arm with Counterbalance: 1-by-6-inch nominal-size pine or redwood with steel counterweights; with painted finish and black diagonal stripes on traffic-side face. Provide mounting flange with breakaway feature to ensure a clean break if arm is struck by vehicle. 1. Length: 18 feet. F. Operator: UL labeled and listed, Class II. 1/3 hp; 120 v, 60-Hz, single-phase, instant-reversing, continuous-duty motor for operating gate arm. Transmit power to gate-arm drive shaft through the speed reducer to harmonic-acting crank and connecting rod. Fabricate crank, rod, and drive shaft of galvanized solid bar steel. Provide an operable cam for adjusting arm travel. 1. Opening Time: Three to six seconds. 2. Inherently adjustable, torque limiting clutch for safety. LIFT ARM PARKING GATES 11 12 33.13-2

St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 G. Characteristics: 1. Additional obstruction detector; noncontact infrared. 2. Barrier-arm warning safety signs on both sides of unit to limit traffic to vehicular traffic. 3. Manually operated crank for emergency operation. 2.02 VEHICLE DETECTORS A. General: Provide detection devices that sense presence or transit of vehicles and emit signals activating gate-arm operators. B. Vehicle Loop Detector System: Self-tuning electronic presence detector with adjustable detection patterns, adjustable sensitivity and frequency settings, and panel indicator light. Include automatic closing timer with adjustable time delay before closing, timer cut-off switch, designed to hold gate arm open until traffic clears. Provide number of loops consisting of multiple strands of wire, number of turns, loop size, and method of placement at location indicated on Drawings, as recommended in writing by detection system manufacturer for saw-cut installation. 1. Field-Assembled Loop: Wire, in size indicated for field assembly. 2. Operation: a. Recognize vehicles within 6 inches of each other on standard-sized loop. b. Recognize vehicle direction by detecting vehicle moving from one loop to another. c. Crosstalk test between adjacent loops. 2.03 ACCESS CONTROL UNITS A. General: Provide access control unit that activates barrier gates. B. Card Reader Controlled Unit: Functions only when authorized card is presented. 1. System: Programmable, multiple-code capability permitting validation or voiding of individual cards. 2. Reader: Proximity type for proximity cards. 3. Operation: Online communication to remote security-access control system computer. 4. Characteristics: Timed antipassback with capability of monitoring and auditing barrier gate activity. 5. Mounting: In enclosed cabinet. 6. Unit Housing: Fabricate from welded cold-rolled steel or aluminum sheet with weatherproof front access panel equipped with flush-mounted lock and two keys. Provide face-lighted unit fully visible at night. a. Metal Finish: Manufacturer's standard baked-enamel or powder-coat finish system. 7. Cards: Provide 25 cards. LIFT ARM PARKING GATES 11 12 33.13-3

St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 C. Remote Controls: Electric controls separated from gate and motor and drive mechanism, with NEMA ICS 6, Type 1 enclosure for surface mounting, and with space for additional optional equipment. Provide the following remote-control device(s): 1. Control Station: Momentary-contact, single-button-operated with open and close function; located remotely from gate. 2. Locate control station as indicated on Drawings or if not indicated as directed by Architect. 2.04 ANCHORAGES A. Anchor bolts; hot-dip galvanized according to ASTM A 153/A 153M and ASTM F 2329. PART 3 - EXECUTION 3.01 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, including equipment bases; accurate placement, pattern, and orientation of anchor bolts; critical dimensions; and other conditions affecting performance of the Work. B. Examine roughing-in for electrical and communication systems to verify actual locations of connections before parking control equipment installation. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.02 INSTALLATION A. General: Install parking control equipment as required for complete and integrated installation. 1. Rough-in electrical connections. B. Lift Arm Gates: Anchor cabinets to concrete bases with anchor bolts or expansion anchors, and mount barrier gate arms. 1. Install barrier gates according to UL 325. C. Vehicle Loop Detectors: Cut grooves in pavement and bury and seal wire loop at locations indicated on Drawings according to manufacturer's written instructions. Connect to parking control equipment operated by detector. 3.03 ADJUSTING A. Adjust parking control equipment to function smoothly, and lubricate as recommended by manufacturer. B. After completing installation of exposed, factory-finished parking control equipment, inspect exposed finishes and repair damaged finishes. LIFT ARM PARKING GATES 11 12 33.13-4

St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 3.04 PROTECTION A. Remove barrier gate arms during the construction period to prevent damage, and install them immediately before Substantial Completion. 3.05 DEMONSTRATION A. Train Owner's maintenance personnel to adjust, operate, and maintain parking control equipment. END OF SECTION LIFT ARM PARKING GATES 11 12 33.13-5