Capanivo Series CN 4000

Similar documents
Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4



Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications


Level limit switch Series RF 3000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list

Continuous level measuring system NB 4000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list

DIAMOND POINT VIBRATING PROBES

Continuous level measuring system NB 3000 Selection list

Kondunivo Table of contents

Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Control and Terminal Box Type A21-**-*****

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

Continuous level measuring system NB 3000 Selection list. Overview

Soliswitch FTE30. Technical Information

CVR-625. Compact Vibrating Rod Instruction Manual

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Capacitive Sensors. Series 80 - PNP

Technical Data. Dimensions

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Operating Instructions

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Nivobob 1. Table of contents. Continuous level measuring system NB 4000 Technical information / Instruction manual. Page

Safety Switches Series 8537

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Operating Instructions

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

10 Load and Motor Switchgear

ExBin-P Pressure switches 5 Pa Pa

Ex m Solenoid Operator Type 0519

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

Plug and Socket Devices SolConeX 16 A Series 8570

Operating Instructions (Translation)

Position Switches Series 8074/2

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

7 Lighting Technology

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Panelboards & Motor Starters

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Load and Motor Switches, Load-Break Switches Series 8549

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

A good connection. International approvals.

Level Measurement Point level measurement - RF Capacitance switches

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

Floodlight LED Series 6525

Level Limit Switch soliphant FTM 930/931/932/ Z

UWT Lot. Table of contents. Continuous level measuring system SLS 3000 Technical information / Instruction manual. Page

Installation and Operating Instructions

A good connection. International approvals.

Accessories Cable glands

IQL Helios Area-/Streetlight. User Manual

Unused flameproof threads for cable glands have to be closed with certified plugs.

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

M-0. M-0... series control, monitoring and signalling devices. Ex e

Isolating transformer ES710

ILED Dorado. User Manual

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Clarius EP PLUS LED FLOODLIGHT Installation Guide

BMRX Series ROTARY LEVEL CONTROL

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/

Floodlight Series 6121

Floodlight LED Series 6125

Floodlight LED Series 6525

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Flow switches Series AD/VH

DIN EN UL 508 / CSA 3RF A A 0 2

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Load and Motor Switches, Load-Break Switches Series 8544

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Compact Sheet-Steel Light Fittings Series 6114/1

YFC. Limit switch. Ex d. 24 operating head types

International approvals.

ILED Aquarius Illuminated Windsock. User Manual

OPTISWITCH 6500 C Technical Datasheet

Load and Motor Switches, Load-Break Switches Series 8544

introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

7 Lighting Technology

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Transcription:

Capanivo Series CN 4000 Instruction manual 010516 1

UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction manual: Types CN 4020 / 4030 / 4050 Approval CE / TR-CU / ATEX / IEC-Ex Electronic modules Relay (SPDT, DPDT) PNP 2

Table of Contents Safety /warning notes Page 4 Fields of application Page 4 Technical Data Page 5 Installation Page 15 Electrical connection Page 21 Settings Page 27 Switching logic Page 29 Maintenance Page 30 Spare parts Page 31 ATEX / IEC-Ex Notes Page 32 3

Safety /warning notes Installation, maintenance and commissioning may be accomplished only by qualified technical personnel. For terminal connection of the device, the local regulations or VDE 0100 (Regulations of German electrotechnical Engineers) must be observed. All field wirings must have insulation suitable for at least 250V AC. The temperature rating must be at least 90 C (194 F). In the case of handling by untrained personnel or handling malpractice, the safety of the device cannot be guaranteed. Fields of application Level limit switch for level limit detection in powder and bulk materials. 4

Technical Data Plastics PA Aluminium 5

CN 4020 120 C Material according to order data Accessory min. -1bar (-14.5psi) max. +25bar (+363psi) ~ 0,5kg (1.1 lbs) 6

CN 4020 180 C L=190mm L=400mm min. -1bar (-14.5psi) max. +16bar (+232psi) ~ 1.8kg (4.0 lbs) 7

CN 4030 Material according to order data min. -1bar (-14.5psi) max. +16bar (+232psi) ~ 0.8 kg (1.8 lbs)+ L: 0.8 kg/m (1.8 lbs/39.9 ) ~ 1.5 kg (3.3 lbs)+ L: 1.6 kg/m (3.5 lbs/39.9 ) (2) 8 = Aluminium (2) = Stainless steel

CN 4050 Material according to order data min. -1bar (-14.5psi) max. +6bar (+87psi) ~ 0.9 kg (2.0 lbs)+ L: 0.25 kg/m (0.55 lbs/39.9 ) ~ 1.4 kg (3.1 lbs)+ L: 0.25 kg/m (0.55 lbs/39.9 ) (2) = Aluminium (2) = Stainless steel 9

C CN 4020 120 C 10

C CN 4020 180 C 11

C CN 4030 12

C CN 4050 13

Bulk material ε r 1.6 <30mm ε r Dielectric constant 14

Installation CN 4020 Protective angle (canopy) in case of high mechanical load 15

CN 4020 (2) (2) Mech. load of the sensor Observe minimum distances (2) 16

CN 4030 Sliding sleeve: Tighten straining screws with 20Nm 17

CN 4030 Mech. load of the sensor Observe minimum distances 18

CN 4050 (2) (2) Mech. load of the sensor Observe minimum distances 19

Fixing Threads 20Nm 40Nm (2) Flat gasket (2) Metal Alignment Ingress protection IP 66 20

Treatment Option: Weather protection cover for Ex only approved for Zone 22 21

Electrical connection Relay SPDT 0.14-2.5mm² (AWG 26-14) 25/26 PE + - max. 10A HBC 250V T/F max. 5A HBC 250V T/F AC max. 250V, 3A (3) DC max. 30V, 5A (3) 21...27V DC ±10% (2), max. 1.5W (4) 2225Vrms (2) (3) (4) Power supply Including 10% from EN 61010 Non inductive Isolating voltage 22

Relay DPDT 0.14-2.5mm² (AWG 26-14) 25/26 (5) PE + - L N 21...230V 50-60Hz ±10% (2), max. 18VA 21...45V DC ±10% (2), max. 2W (5) (5) AC max. 250V, 8A (3) DC max. 30V, 5A (3) (5) max. 10A HBC 250V T/F 2225Vrms (4) 2225Vrms (2) (3) (4) Power supply Including 10% from EN 61010 Non inductive Isolating voltage 23

PNP 0.14-2.5mm² (AWG 26-14) 25/26 max. 4A HBC 250V T/F max. 0,4A PE + - 20...40V DC ±10% (2), max. 0.5A (2) Power supply Including 10% from EN 61010 24

Functional grounding by process connection (2) (2) Metal Use flat gasket, no teflon tape 25

alternative by cable (2) (2) Use internal or external terminal Grounded metal parts in case of non metal bin 26

Settings Relay SPDT 29 14 Signal delay 27

Relay DPDT / PNP Signal delay 29 14 28

Signal output logic 27 yellow green green yellow = Relais SPDT (2) = Relay DPDT (3) = PNP (4) = LED Signal 29

Maintenance 30

Spare parts CN 4020 120 C SPDT 21..27V DC pl406100 DPDT 21..230V AC 21..45V DC pl406110 PNP 20..40V DC pl406120 SPDT DPDT CN 4020 180 C DPDT 21..230V AC 21..45V DC pl406111 PNP 20..40V DC pl406121 CN 4030 / CN 4050 PNP No spare parts available 31

ATEX + IEC-Ex Notes Permitted relative pressure -0,2...+0,1bar (-2.9 +1.45psi) Ambient temperature T Max. surface temperature 60 C (140 F) 60 C (140 F) 60 C (140 F) CN 4020: 120 C (248 F) CN 4030: 110 C (230 F CN 4050: 80 C (176 F) 120 C (248 F) 120 C (248 F) 135 C (275 F) 60 C (140 F) 60 C (140 F) 60 C (140 F) 60 C (140 F) 60 C (140 F) 60 C (140 F) 60 C (140 F) CN 4020: 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) 160 C (320 F) 170 C (338 F) 180 C (356 F) CN 4020: 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) 160 C (320 F) 170 C (338 F) 180 C (356 F) 32

Installation (2) (2) A pull relief must be provided Connect with equipotential bonding of the plant 33

ATEX / IEC-Ex: Further Remarks For installation and field wiring the respectively valid installation regulations of the respective country must be observed. Commissioning only with closed lid. Do not remove the lid (cover) while circuits are alive. Before opening the lid take care, that no dust deposits or whirlings are present. The installation has to be carried out in a way, that mechanical friction or impact does not cause sparks between the aluminium enclosure and steel. Cable glands: Installation according to the regulations of the country, where the product is installed. Not used entries have to be closed with blanking elements certified for this purpose. Where applicable the factory provided parts must be used. A strain relief must be provided for the field wiring cables, when the device is installed with the factory provided cable glands. The diameter of the field wiring cable must match to the clamping range of the cable clamp. If other than the factory provided parts are used, following must be ensured: The parts must have an approval adequate to the approval of the level sensor (certificate and type of protection). The approved temperature range must be from the min. ambient temperature of the level sensor to the max. ambient temperature of the level sensor increased by 10 Kelvin. The parts must be mounted according to the instructions of the supplier. 34