Wind Energy Conversion System using Back to Back Power Electronic Interface with DFIG

Similar documents
Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Performance Analysis of Grid Connected Wind Energy Conversion System with a PMSG during Fault Conditions

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

Dynamic Analysis of Grid Connected Wind Turbine with a Permanent Magnet Synchronous Generator during Fault Conditions

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

Performance Analysis of DFIG Based Wind Power Generation under Unbalanced Conditions

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Possibilities of Distributed Generation Simulations Using by MATLAB

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Control Scheme for Grid Connected WECS Using SEIG

A New Control Algorithm for Doubly Fed Induction Motor with Inverters Supplied by a PV and Battery Operating in Constant Torque Region

Using energy storage for modeling a stand-alone wind turbine system

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Studies regarding the modeling of a wind turbine with energy storage

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

K. M. Aboras and A. A. Hossam El-din Ahmed H. H. Ali. Egypt-Japan University of Science and Technology

Neural network based control of Doubly Fed Induction Generator in wind power generation.

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Asian Journal on Energy and Environment ISSN Available online at

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM

PERFORMANCE ANALYSIS OF SQUIRREL CAGE INDUCTION GENERATOR USING STATCOM

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Dynamic Response Analysis of Small Wind Energy Conversion Systems (WECS) Operating With Torque Control versus Speed Control

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Increasing the Power Quality for Grid Connected Wind Energy System Using Facts

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

Wind Farm Evaluation and Control

Sliding Mode Control of a Variable Speed Wind Energy Conversion System based on DFIG

International Journal of Advance Research in Engineering, Science & Technology

DUAL BRIDGE RECTIFIER FOR PMSG VARIABLE SPEED WIND ENERGY CONVERSION SYSTEMS

RTDS Training course of IEPG

Statcom Operation for Wind Power Generator with Improved Transient Stability

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Vector Control of wind conversion system based on a

Design and Modelling of Induction Generator Wind power Systems by using MATLAB/SIMULINK

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

Available online at ScienceDirect. Energy Procedia 42 (2013 ) Mediterranean Green Energy Forum MGEF-13

Performance Analysis of SCIG Coupled With Wind Turbine with and Without Fault Using RLC Load

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Modelling and Simulation of DFIG with Fault Rid Through Protection

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

Converteam: St. Mouty, A. Mirzaïan FEMTO-ST: A. Berthon, D. Depernet, Ch. Espanet, F. Gustin

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Low-Voltage Ride-Through Capability Improvement of DFIG-Based Wind Turbines

Wind Generation and its Grid Conection

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Modeling Of DFIG and Improving the LVRT Capability Of System Using Crowbar And Battery Energy Storage System

Open Loop Control of Switched Reluctance Motor Using Theta Position Sensing

Power Control of a PMSG based Wind Turbine System Above Rated Wind Speed

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

BEHAVIOUR OF VECTOR CONTROLLED DFIG BASED LOW VOLTAGE WECS AT VARIOUS WIND SPEEDS

Wind Turbine Emulation Experiment

Fault Rid Through Protection of DFIG Based Wind Generation System

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

Design and Simulation of Wind Energy Conversion System Synchronized with Electrical Grid Using DFIG

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine

e t Electronics Based Dump Load Controller (DLC) for an Grid Isolated Asynchronous Generator (GIAG)

Keywords: DFIG wind turbine, MPPT, Voltage stability control, Power factor control, PSCAD simulation, Voltage oriented vector control.

Chapter 2 Literature Review

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

Adaptive Power Flow Method for Distribution Systems With Dispersed Generation

Maximum Power Point Tracking in DFIG based Wind Energy Conversion System using HCS Algorithm

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 201

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

Controlling Of DFIG Wind Turbine Under Unbalanced Grid Fault Condition

Wind-Turbine Asynchronous Generator Synchronous Condenser with Excitation in Isolated Network

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Modeling and Neuro-Fuzzy Control of DFIG in Wind Power Systems for Grid Power Leveling

DC Voltage Droop Control Implementation in the AC/DC Power Flow Algorithm: Combinational Approach

Simple Direct Sensorless Control of Permanent Magnet Synchronous Generator Wind Turbine

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Synchronous Motor Drives

Modelling and Simulation of DFIG based wind energy system

A Dual Stator Winding-Mixed Pole Brushless Synchronous Generator (Design, Performance Analysis & Modeling)

CONTROL OF DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Transcription:

Wind Energy Conversion System using Back to Back Power Electronic nterface with DFG B.D. GDWAN Department of Mechanical Engineering Engineering College Ajmer Ajmer, Rajasthan NDA gd97@rediffmail.com Abstract: - This paper presents a grid connected DFG WECS using back to back power electronic interface. Transient simulations are carried out under the condition of sudden short circuit disturbances. The paper aims to present in a thorough and coherent way the aspects of power quality in terms of Total Harmonic Distortion (THD) at various fault locations and buses. Simulated results are obtained in detail. All the simulations are made in Matlab/Simulink. Key-Words: - Doubly Fed nduction Generator, Power Electronic nterface, Power Quality, Total Harmonic Distortion, Wind Energy Conversion System. 1 ntroduction Wind Energy Conversion Systems (WECS) constitute a mainstream power technology that is largely under exploited. Wind technology has made major progression from the potypes of just 30 years ago. The main differences in WECS technology are in electrical design and control. At present, typically two types of WECS for large wind turbines exists [1-3]. The first one is a variable speed WECS that allows variable speed operation over a large, but still restricted, range. This type of WECS mainly uses a Doubly Fed nduction Generator (DFG) with the stator windings connected directly to the three phase constant frequency grid and the or windings connected to a partial scale back to back converter. A multi stage gear box is necessary in this drive. This type of WECS offer high controllability, smoother grid connection, maximum power extraction and reactive power compensation using back to back power converters of rating near to 25-30% of the generator capacity [2-4]. The complete modelling and simulation of a grid interfaced WECS based on DFG, using dynamic vector approach is presented in [7-8]. The paper is organized as follows: Section 1 presents an introduction along with objectives of the present work. System configuration and proposed strategy are described in Section 2. The simulation models developed in MATLAB Simulink are detailed in Section 3 and the results obtained from models are explained in Section 4. The conclusions drawn from these results are finally summarized in Section 5. 2 Modeling of Wind Turbine The modelling of wind turbine will now be discussed here. The mechanical power available from a wind turbine is as follows [9] : (1) where, P w is power extracted from the wind, ρ is air density, R is blade radius, V w is wind speed and C p is power coefficient. C p is given as a nonlinear function of the parameters tip speed ratio λ and blade pitch angle β. The calculation of the power coefficient requires the use of blade element theory. As this requires knowledge of aerodynamics and the computations are rather complicated, numerical approximations have been developed [10]. Here the following function will be used [9] (2) where, λ is tip speed ratio and β is blade pitch angle. The tip speed ratio is given as : V w λ = (3) ωb where, ω B is ational speed of turbine. Usually C p is approximated as, SBN: 978-960-474-400-8 330

(4) where α, β and γ are constructive parameters for a given turbine. The torque developed by the windmill is (5) To describe the impact of the dynamic behaviour of the wind turbine, a simple model is considered, where the tower bending mode and the flap-bending mode of the wind turbine are neglected [9]. Emphasis is placed on the parts of the dynamic structure of the wind turbine. The transmission is described by following equations : dt dω = k = T s ω T ω η gen gear (6) (7) where, is or inertia, ω is turbine or speed, ω gen is generator speed, T is or torque, T is low-speed shaft torque, k s is shaft stiffness and η gear is ratio of gear box. t is also assumed that the losses in the gearbox are zero. Thus the gear transmits ideally from the low speed to high speed. The output of the model is T T hss = (8) ηgear where, T hss is high-speed shaft torque. The high speed shaft torque, T hss is the mechanical torque input, T m to wind generator used. The design parameters of wind turbine are shown in Table 1. Table 1: Design Parameters of Wind Turbine Wind Turbine Data for One Wind Turbine Nominal Wind Turbine Mechanical Power Base Wind Speed Pitch Angle Controller Proportional Gain 5 Pitch Angle Controller ntegral Gain 25 Maximum Pitch Angle Maximum Rate of Change of Pitch Angle 3 x 10 6 Watt 9 m/sec. 45 deg. 2 deg./sec 3 WECS using DFG with Back to Back Converters This section considers the mutual effects of integrating wind power using DFG with back to back converters in power systems under transient fault situations. A 9 MW wind-farm consisting of three 3 MW wind turbines, connected to a 33 kv distribution system, exports power to a 220 kv grid through a 30 km, 33 kv feeder. A 500 KW resistive load and a 0.9 MVAR (Q = 50) filter are connected at the 440 V bus. A fault is simulated and connected to 132 kv line and grounding transformer is connected to 33 kv bus. Fig.1 shows the layout of the wind system with its interconnection to the transmission grid. 220 kv Bus 220 kv/132 kv 132 kv Bus 132 kv/33 kv 33 kv Bus X0=4.7 Power System Fault 33 kv/440 V B 4 V- measurement 440V Bus B 1 THD measurement WT using DFG Load Fig. 1: Power System Model ntegrated with Wind Power using DFG While modeling DFG, the generator convention will be used, which means that the currents are outputs instead of inputs and real power and reactive power have a positive sign when they are fed into the grid. The d-q reference frame is ating at synchronous speed with the q-axis 90 ahead of the d-axis. The position of the d-axis coincides with the maximum of the stator flux. The flux linkages can be calculated using the following set of equations in per unit : B 3 B 2 (9) (10) SBN: 978-960-474-400-8 331

(11) (12) where L s and L r are stator and or leakage inductance respectively and L m is the mutual inductance between the stator and the or. The or slip s is defined as : p ωs ωm s = 2 (13) ωs where p is the number of poles and ω m is the mechanical frequency of the generator. The active power P and reactive power Q generated by the DFG : (14) (15) Equation 9 to Equation 15 describes the electrical part of a DFG. However, also the mechanical part should be taken into account in developing a dynamic model. The following equation gives electromechanical torque T e generated by DFG : (16) The mechanical torque can be calculated by dividing power extracted from the wind, P w by the mechanical generator frequency ω m. The changes in generator speed that result from a difference in electrical and mechanical torque are calculated as : dω = 1 2H ( ) T m T e (17) where H is the inertia constant and T m is the mechanical torque. The design parameters of DFG are shown in Table 2. Table 2: Design Parameters of DFG Generator Data for One Turbine Nominal Electrical Power 3.33 x 10 6 VA Stator Resistance, R s 0.023 p.u. Stator nductance, L s 0.18 p.u. Rotor Resistance, R r 0.016 p.u. Rotor nductance, L r 0.16 p.u. Magnetizing nductance, L m 2.9 p.u. nertia Constant, H 0. 685 Pairs of Poles, p 3 The WECS considered for analysis consist of a DFG driven by a wind turbine, or side converter and grid side converter, as shown in Fig.2. Wind Turbine Rotor Drive Train Stator nduction Generator Pitch Angle Rotor Side Converter V r C Control System Grid Side Converter Fig.2: WECS with DFG and Converters V C AC Grid Rotor side converter consists of three phase GBT- Diode rectifier connected in Graetz bridge configuration with snubber resistance and capacitance. The power is controlled in order to follow a pre-defined power-speed characteristic, named tracking characteristic. The circuit is discretized at a sample time of 2 micro seconds. Grid side converter also consists of three phase GBT-Diode rectifier connected in Graetz bridge configuration. The grid side converter is used to regulate the voltage of the DC bus capacitor. The pitch angle control is used to limit the power extracted at high wind speeds conditions. n this model the wind speed is maintained constant at 10 m/sec. The control system uses a torque controller in order to maintain the speed. The reactive power produced by the wind turbine is also regulated at zero MVAR. Rotor side converter consists of three-phase GBTdiode rectifier connected in Graetz bridge configuration with snubber resistance and capacitance. The values of snubber resistance R s and snubber capacitance C s for or converter are derived from the following criteria: The snubber leakage current at fundamental frequency is less than 0.1% of nominal current when power electronic devices are not conducting. The time constant (RC) of snubbers is higher than 2 time sample time (2 T s ). The circuit is discretized at a sample time of 2 µs. Fig.3 shows voltage and VAR regulation of or SBN: 978-960-474-400-8 332

side converter. A Proportional-ntegral (P) regulator is used to reduce the power error to zero. The actual component of positive-sequence current ( qr ) is compared to qrref and the error is reduced to zero by a current regulator (P). The output voltage of this regulator is q-axis or voltage V qr. The reactive power at grid terminals is kept constant by a VAR regulator. converter (V c ) from the dcref produced by the DC voltage regulator and specified qref. The pitch angle is regulated at zero degree by pitch angle regulator until the speed w r reaches desired speed of the tracking characteristic w d. Beyond w d, the pitch angle is proportional to the speed deviation from desired speed. The control system is illustrated in the Fig.5. Q ref V Q VAR VAR dr ref V dc V dc ref DC Voltage dcref V Tracking Characteristics Power r P ref P Power dr qr - qrref V dr, V qr c dc qc qc ref Fig.4: s of Grid Side Converter V c gc Power Losses Pl Pitch Angle Max s & r Fig.3: s of Rotor Side Converter. The output of the voltage regulator or VAR regulator is d-axis reference or current drref which is injected in the or by or converter. The same current regulator is used to regulate the actual component of positive-sequence current ( dr ). The output of this regulator is the d-axis or voltage V dr. The control system of grid side converter, illustrated in the Fig.4 consists of: systems which measure d-axis and q-axis components of AC positive-sequence currents to be controlled as well as the DC voltage V dc. An outer regulation loop which consists of a DC voltage regulator. The output of the DC voltage regulator is the reference DC current dcref for the current regulator ( dc = current in phase with grid voltage which controls active power flow). An inner current regulation loop which consists of a current regulator. The current regulator controls the magnitude and phase of the voltage generated by ω d Pitch Angle Gain 0 Fig.5: Pitch Control System. Pitch Angle 4 Results and Discussions THD measured at different buses during unsymmetrical and symmetrical faults and at different fault locations is shown in Table 3. t is observed that THD is maximum when measured at bus B1 during single phase fault at bus B1 and minimum when measured at bus B4 during phase to phase to ground fault at bus B1. THD values are comparitevely less when measured at bus B4 and more when measured at bus B1. t is observed that THD measured at bus B1 is same when fault occurs at bus B4 irrespective of type of fault. The same is true when THD is measured at buses B2 to B4. THD is more when measured at Bus B1, decreases as bus voltages increase, becoming minimum when measured at Bus B4. SBN: 978-960-474-400-8 333

Table 3: THD Measured at Different Buses Fault THD Measured (% of Fundamental) at Bus B1 Bus B1 9.94 9.4 7.68 7.79 6.39 6.69 Bus B2 9.8 8.96 7.68 7.68 7.42 7.42 Bus B3 10.52 9.76 7.94 8.9 9.76 7.24 Bus B4 9.89 9.89 9.89 9.89 9.89 9.89 Fault THD Measured (% of Fundamental) at Bus B2 Bus B1 5.27 5.29 5.28 5.42 4.93 5.02 Bus B2 5.1 5.4 8.18 7.59 7.33 7.33 Bus B3 5.46 6.26 5.32 5.62 6.26 5.7 Bus B4 5.32 5.32 5.32 5.32 5.32 5.32 Fault THD Measured (% of Fundamental) at Bus B3 Bus B1 2.31 2.34 2.94 3.03 3.39 3.36 Bus B2 2.19 2.72 7.68 7.45 7.31 7.31 Bus B3 2.8 4.08 3.79 4.1 4.06 4.51 Bus B4 2.29 2.29 2.29 2.29 2.29 2.29 Fault THD Measured (% of Fundamental) at Bus B4 Bus B1 0.11 0.09 0.08 0.07 0.13 0.11 Bus B2 0.09 0.1 0.28 0.29 0.3 0.3 Bus B3 0.14 0.18 0.17 0.19 0.18 0.19 Bus B4 0.1 0.1 0.1 0.1 0.1 0.1 5 Conclusion An attempt has been made in this paper to analyse the performances of the WECS based on DFG, pertaining to power quality, active power, reactive power and speed control that each of the generators can handle. The system models are developed in the MATLAB/Simulink. This paper has presented the detailed model of the variable speed wind turbine with DFG connected to power grid through back to back power electronic interface simulated. THD is measured at different locations during different faults at different buses. t is observed that THD is more when measured at Bus B1, decreases as bus voltages increase, becoming minimum when measured at Bus B4. References: [1] H Li, Z Chen, Overview of Different Wind Generator Systems and their Comparisons, ET Renewable Power Generation, Vol. 2, No. 2, 2008, pp. 123-138. [2] D. Rajib, VT Ranganathan, Variable Speed Wind Power Generation using Doubly Fed Wound Rotor nduction Machine - A Comparison with Alternative Schemes, EEE Transactions on Energy conversion, Vol. 17, No. 3, 2002, pp. 414-421. [3] R. Mittal, KS Sandhu, DK. Jain, An Overview of Some mportant ssues Related to Wind Energy Conversion System (WECS), nternational Journal of Environmental Science and Development, Vol. 1, No. 4, 2010, pp. 351-363. [4] F.A. Ramirez, M.A. Arjona, Development of a Grid-Connected Wind Generation System with a Modified PLL Structure, EEE Transactions on Sustainable Energy, July 2012, Vol. 3, ssue 3, pp. 474-481. [5] R.J. Wai, C.Y. Lin, Y.R. Chang, Novel Maximum-Power-Extraction Algorithm for PMSG Wind Generation System, ET Electric Power Applications, Vol. 1, ssue 2, Mar. 2007, pp.275-283. [6] Y.M. Kawale, S. Dutt, Comparative Study of Converter Topologies used for PMSG Based Wind Power Generation, Proc. nt. Conf. on Computer and Electrical Engg., Dubai, Dec. 28-30, 2009, Vol. 2, pp. 367-371. [7] B. Chitti, K.B. Mohanty, Doubly Fed nduction Generator for Variable Speed Wind Energy Conversion Systems Modeling and Simulation, nternational Journal of Computer and Electrical Engineering, Vol. 2, No. 1, 2010, pp. 141-147. [8] LM Fernandez, CA Garcia, F Jurado, Comparative Study on the Performance of Control Systems for DFG Wind Turbines Operating with Power Regulation, Energy 33, 2008, pp. 1438-1452. [9] J.G. Slootweg, H. Polinder, W.L. Kling, Dynamic Modeling of a Wind Turbine with Doubly Fed nduction Generators, EEE Power Engg. Society Summer Meeting, Vancouver, BC, Jul.15-19, Vol. 1, 2001, pp. 644-649. [10] D. Liu, J. Hu, C. Zhang, Blade Design for a Horizontal Axis Variable Speed Wind-Driven Generator, World Non-Grid-Connected Wind Power and Energy Conf., Nanjing, Nov. 5-7, 2009, pp. 1-4. SBN: 978-960-474-400-8 334