Functions provided by measuring relays in railway equipment

Similar documents
2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Publication No.: PSG

34 th Hands-On Relay School

COM Overcurrent Relay

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

KD LV Motor Protection Relay

Government Polytechnic Muzaffarpur Name of the Lab: Electric Traction-II Lab

EE 741 Over-voltage and Overcurrent. Spring 2014

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

TECHNICAL DESCRIPTION

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

AIR COOLED RECTIFIER SPECIFICATION S-50-A

TECHNICAL DESCRIPTION

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Components for EEx e Panels

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Auxiliary Relay. Type RXP8n, RXPQ8n

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Type SOQ Negative Sequence Time Overcurrent Relay

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

Technical Description

Horizontal Circuit Switchers

Horizontal Circuit Switchers

LR9 F OVERLOAD RELAYS

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Auxiliary Relay. Type CV2

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

SECTION MOTOR CONTROL

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Model HEA Multicontact Auxiliary

Protection and control VIP30, VIP35. Relays technical manual

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

Auxiliary Relay. Type P8n, PQ8n, PN8n

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Outdoor vacuum breaker for railway applications - FSK II

Power Electronics. Motor brake relay GA 9031 ministop

Transforming Energy.. For Advanced Technology

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

The galvanic separation of the primary or actuating circuit and the load circuits

.3 Section Waste Management and Disposal.

Electronic Protection Systems for Direct Current Railways. The Future for Railways Made in Germany

8. Filter / Autoranging Rectifier Module (FARM )

Reverse power relay and protection assemblies

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

LOCOMOTIVE CIRCUIT BREAKER MAINTENANCE TEST SETUP

Electrical network protection VIP30, VIP35. User s manual 12/2008

Power System Solutions (PSS)

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

MX431 Generator Automatic Voltage Regulator Operation Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER


CP Automatic capacitor bank

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

XM1 - Motor protection relay

MAGNETIC MOTOR STARTERS

Control Relays Overview

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Ceramic PTC Thermistor:

Essential equipment for all your requirements

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Adapted from presentation developed by Scott Fausneaucht

B CW POWER RELAY

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Installation Manual for DC Injection Brake Units

Battery powered ignition

AF series contactors (9 2650)

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

1 THE WOLVERTON SYSTEM OF TRAIN LIGHTING.

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

MaxPak Plus Analog DC V S Drive

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Presented to the IAPMO Standards Review Committee on December 9, 2013

Ledex Drive Electronics and Coil Suppressors

Specification for 1500V DC Traction Supply WOS 01.E

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

Zone Selective Interlocking

DPX moulded case circuit breakers

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Qingdao Zener Electric Co., Ltd

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

1489-M Circuit Breakers

GP/GPA GROUND FAULT PROTECTION

Power systems Protection course

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Solid Dielectric, Single Phase Recloser

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

Transcription:

Functions provided by measuring relays in railway equipment 1-Current relays -Minimum current relays (During normal operation, if the current is present these relays are in operating position and switch to rest state if current consumption becomes too low.) -Operate with direct current (DC) or alternating current (AC). -Close if the current drops below the rated operating value. -Open if the current value is greater than 0. -Used to check that current is present in a circuit, in other words to check that the power supply is operating. -Examples of application: -Checking the presence of the power supply current for a DC motor, -Checking the presence of the power supply current for a traction line. -Checking the current direction in a traction line (braking or traction). -Maximum current relays (During normal operation, if the current is present these relays are in rest position and switch to operating position if current consumption becomes too great.) -Operate with direct current (DC) or alternating current (AC). -Reset if the current value exceeds the normal operating value. -Used to protect a circuit against an overload harmful to operation. -Examples of application: -Protects the primary or secondary side of a power transformer. The relay coil is energised by a measuring core. In the event of overload, it transmits a signal acting directly on the tripping circuit. -Monitoring traction or braking overload. -Monitoring auxiliary circuit overload. Note: exists as an option in polarised version, with time-delay, and adjustable pick-up and drop-out values. -Current balance relays -Operate with direct current. -These relays have two coils used to compare two currents which should normally be balanced. They close. if the difference between the two currents measured reaches an abnormal level. -Examples of application: -Checking the input and output currents of a motor or traction line or current imbalance resulting from an isolation fault. -Checking current imbalance in the circuit of two traction motors mounted in series. -Relay for thyristor filter short-circuiter: this relay protects the precharge resistor of the filter.

2-Voltage relays -Minimum voltage relays -Operate with direct current (DC) or alternating current (AC). -Close for a voltage value less than the rated operating value. -Check the presence of voltage at the terminals of a circuit to confirm that the power supply is operating. -Examples of application: -Checking absence of line voltage (sensing function) for single-phase alternating current or direct current; pick-up and drop-out can be delayed to offset pantograph bounce. -Monitor the presence of voltage at the auxiliary circuit terminals. -Maximum voltage relays -Interval relays -Operate with direct current (DC) or alternating current (AC). -Close for a voltage value greater than the rated operating value. -Used to protect a circuit against overvoltage harmful to operation. -Operate with direct current (DC) or alternating current (AC). -In make position when the voltage is between two set values and in break position if the voltage is less than the minimum setpoint or greater than the maximum setpoint. -Examples of application: -Monitoring a network or power supply. -Voltage balance relays -Based on the same principle as current balance relays (see above). -Battery voltage test relay (charge or discharge). 3-Other functions -Time-delay relays with pick-up or drop-out time-delay. This function can be installed with most of the functions described in the other paragraphs. -Grounding detection relays used to detect accidental grounding of circuits by current measurement. -Relays monitoring current return to the rail used to protect persons and equipment against a fault in the circuit returning the traction current to the rail. -Wheel slip monitoring relay, for two traction motors connected in series.

!"#$%&'%(##$)&'*$+,(#")-'#$.+/ Application: This relay monitors the presence of current in the traction circuit of electric railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle. The traction or braking current passes through the relay which is energised at a threshold set in the factory. Maximum dielectric isolation between the power rail and the contacts is 20KV 50HZ 1mn. The pick-up threshold current of the relay is 100A. The drop-out threshold current of the relay is 50A. The rated primary current varies from 600A to 2000A depending on the power of the traction system. These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. NC NO Damping rings I primary 1348ST

%(##$)&'01$#.0+!'&$,&'#$.+/ Application: This relay monitors the overload current in the traction circuit of electric railway equipment such as: Subway systems Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle The traction and braking current passes through the relay which is energised at a pre-set overload current. Maximum dielectric isolation between the power rail and the contacts can be 20KV 50HZ 1mn. The pick-up threshold value of the relay depends on the specifications. The drop-out threshold value of the relay is immaterial. The rated primary current is determined according to the traction line power. These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. NC NO I primary 1429ST

20.+#",$!'%(##$)&'*$+,(#")-'#$.+/, Application: This relay differentiates the traction current from the braking current in the traction circuit of electric railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle. The traction current or braking current passes through the relay which, because it is fitted with a magnetic diode, can only be energised in one direction of the current (direct). Maximum dielectric isolation between the power rail and the contacts can be 20KV 50HZ 1mn. The pick-up threshold current of the relay for the traction current direction is 100A. The non-pick up threshold current of the relay for the braking current direction is 2000A. The rated primary current varies from 600A to 2000A depending on the traction equipment. These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. NC NO Dumping rings I direct 1416ST

!"##$%&'($)*"#+%,'+%-$#*$'&+($'#$.)/ Application: This relay protects the filter precharge resistor of a traction circuit chopper on railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle The filter precharge resistor is sized to take the power required by the capacitor load but cannot permanently withstand the maximum load current. It is therefore short-circuited by a thyristor or capacitor and the relay triggers the opening of the precharge circuit, by measuring the current passing through the resistor using a higher response curve than the theoretical precharge curve of the capacitor. Dielectric isolation between the power rail and the contacts is 10KV 50HZ 1mn. The pick-up threshold depends on the filter precharge curve. The response time is inversely proportional to the current passing through the relay. The rated primary current varies from 600A to 2000A depending on the power of the traction system. These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. NC NO 1206ST

!"33$#$)&"+.'%(##$)&'*$+,(#")-'#$.+/ Application: This relay monitors isolation faults in the traction circuit of electrical railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle. The traction current crosses the relay, with the positive in opposition to the negative. If there is an isolation fault, the differential of the two currents is no longer zero and the relay switches to make position. The dielectric isolation between the two power rails may be 20KV 50HZ 1mn. The pick-up threshold current of the relay in l varies from 80A to 200A depending on the power rating of the traction system. The rated primary power varies from 600A to 2000A depending on the rated power of the traction system. These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. The relay has a very fast response time. In addition, it is inversely proportional to the level of the fault current (inverse time). NO NC IA IB 1357ST

,40#&5%"#%("&'%(##$)&'*$+,(#")- #$.+/'30#'&4$'&#+),30#*$#'2#"*+#/ Application: This relay triggers the opening of the main circuit breaker of a 50Hz or 16Hz2/3 traction line if the power transformer primary is short-circuited, for electric railway equipment such as: Electric locomotives Any other electric traction vehicle with pantograph power supply. The relay is energised by a measuring core with a ratio of 100 connected to the 25KV 50 Hz or 18KV 16Hz2/3 power transformer primary. The relay closes if the current is greater than the magnetising current of the transformer. Dielectric isolation between the coil circuit terminals (measuring core secondary) and the contact terminals is 1.5KV 50HZ 1mn, high voltage isolation being provided by the measuring core. The operating thresholds vary according to specifications. They are adapted to the catenary power supply networks and the transformer power. These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. NO NC Dumping rings I ac. BR 1405ST

,")-.$524+,$'%(##$)&'&$,&'#$.+/ Application: This relay is used to check a 50HZ or 60HZ or 16HZ 2/3 single-phase current. For all railway applications, rolling stock or fixed installations. The operating characteristics range from a few amperes to several hundred amperes. The current is measured by a cable crossing the core. Dielectric isolation between the coil circuit terminals (measuring core secondary) and the contact terminals is 1.5KV 50HZ 1mn, with isolation of the 10KV high voltage provided by the measuring core and the insulating sheath of the cable crossing it. Pick-up and drop-out values vary according to specifications. These relays are fitted with a NO contact and NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. I NC NO Dumping rings 1409ST

&$,&'#$.+/'30# %(##$)&'#$&(#)'&0'#+". Application: This relay monitors the traction current return via the ground shunt braids of the axle boxes of electric railway equipment such as: Electric locomotives Under normal operation, the relay is short-circuited by the current return circuit in the axles. If the normal return circuit is broken, the current return passes through the axle boxes via resistors and causes the relay to close. These relays provide protection of personnel by preventing the line voltage from passing through the body of the motor unit and protects the bearings of the axle boxes. Dielectric isolation is 2KV 50HZ 1mn. The pick-up threshold current of the relay is 6A 50HZ or 16HZ 2/3 or 7Acc. These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. ESSIEU 1 ESSIEU 2 ESSIEU 3 ESSIEU 4 Axle boxes Axle +HV Return to rail in event of anomaly Traction system Normal return to rail Return to rail -HV 1448ST

4$+&'&#+%")-'%+6.$'2#0&$%&"0)',/,&$* Application: This product is a Hall-effect system that monitors the current in the heat tracing cable circuit of the traction rails for aerial subways. The heat tracing cables are powered directly by the traction 750 VDC power supply. They are connected in series along the tyre running strips of the rails in order to thaw them during cold weather before operating the rolling stock. The system comprises two relays, one measuring the minimum current to indicate a break in the heat tracing cable circuit and the other measuring the maximum current to indicate that a section of the heat tracing cable circuit is in short circuit with the rail. Dielectric isolation between the current measurement and the relay contacts is 10KV 50HZ 1mn. Pick-up and drop-out thresholds depend on the length of the heat tracing cable circuit. This monitoring system requires a permanent auxiliary source. The rated primary current varies from 10A to 50A depending on the network configuration. The relays are fitted with a NO contact and NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. + I dc AUXLIARY SOURCE 220 V alt. Relay A 1 2 3 4 Primary - I dc Secondary 0 Measure t ANALOGUE OUTPUT 5 6 7 8 Relay B 1109ST

%(##$)&',$),0# 7"&4',"-)+.'2#0%$,,")- Application: This sensor measures the current level delivered by electric railway equipment substations operating under 750VDC, 1500VDC or 3000VDC. The sensor is directly connected to the output of the substation rectifier bridge. The first module delivers a secondary current proportional to the direct current delivered by the substation: e.g. 0/20mADC or secondary 4/20mADC for primary 0/2000ADC, and the second module delivers a logic signal for an inverse current threshold indicating the failure of a branch of the substation rectifier bridge. Dielectric isolation between the primary circuit bar and the secondary circuit terminals can be 20KV 50HZ. This sensor is used primarily to guarantee galvanic isolation between the substation output voltage and the distribution board device indicating the voltage level, and to protect the rectifier bridge on the substation power circuit. This equipment requires an auxiliary power supply rated according to specifications: e.g. 0/+24VDC or 220V. 1234ST

6+&&$#/'10.&+-$'*0)"&0#")-'#$.+/ Application: This relay monitors the voltage level of the LV auxiliary network batteries for electric railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives Diesel locomotives Any other electric traction vehicle. The battery voltage energises the coil of the relay which closes at a threshold set in the factory. It opens when the voltage becomes too low in order to reduce battery drain by load shedding on the auxiliary circuits. The relay can have a slight drop-out delay to offset transient voltage drops. Dielectric isolation between the measuring coil and the contacts is 2KV 50HZ 1mn. The pick-up threshold voltage of the relay is lower than the rated voltage of the battery. The drop-out threshold voltage of the relay is greater than the minimum contractual level of the battery. The rated coil voltage varies from 24VDC to 110VDC depending on the equipment specifications. These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. NO NC 1294ST

,")-.$524+,$'.")$'10.&+-$',$),")-'#$.+/ Application: This relay monitors the voltage level of a pantograph power supply line for rolling stock of electric railway equipment such as: Electric locomotives Any other electric traction vehicle with catenary power supply The relay is powered by a secondary winding of the 25KV 50 Hz or 18KV 16 2/3 Hz power transformer. It is energised continuously, while the line voltage is at least equal to the minimum authorised voltage. The relay opens when the line voltage drops below the minimum authorised level. It has a time delay of a few milliseconds to allow for pantograph bounce. Dielectric isolation between the coil circuit terminals and the contact terminals is 2.5KV 50HZ 1mn, high voltage isolation being guaranteed by the power supply transformer secondary. The operating thresholds vary according to the type of load. They are adapted to catenary power supply networks. These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. NO 110 V AC BR R1 D1 R3 NC R2 C1 1312ST

41'-#0()!'3+(.&'!$&$%&"0)'#$.+/ Application: This relay detects an isolation fault in the HV cables on electric railway equipment powered via a power transformer, such as: Electric locomotives The relay coil is connected between the - HV wiring and the + battery, with the - HV cable not connected to the general ground of the vehicle and the - battery connected directly to the general ground of the vehicle. If there is an isolation fault between the HV wiring and the general ground, the relay coil is directly energised by the battery and closes. If there is no isolation fault, the relay coil is never energised. The relay pick-up threshold voltage is lower than the minimum level of the battery voltage, and there is no drop-out threshold voltage since the relay opens when the power supply is cut. Dielectric isolation between the coil circuit terminals and the contact terminals is 10KV 50HZ. This relay is fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. NC NO 1385ST

89:1!%'!$&$%&"0)'#$.+/ Application: This relay monitors the presence of voltage in fixed railway installations of 750VDC networks such as: Subway systems Tramways Trolley buses etc. The relay is powered by the 750VDC network of the substation and is continuously energised while the voltage is between 500VDC and 900VDC. It can withstand high voltage surges. The relay drops out when the 750VDC voltage disappears or drops below 250VDC. Dielectric isolation between the coil circuit terminals and the contact terminals is 10KV 50HZ 1mn. These relays are fitted with two NO contacts and two NC contacts with a breaking capacity of 2A 220V 50Hz. Pin 7 - NC1 Pin 2 - NO1 Pin 5 - Pin 1 - Pin 9 NC2 Pin 4 - NO1 Pin 8 Pin 3 + HV - 1214ST

;9::1!%'10.&+-$'*$+,(#")-'#$.+/ Application: This relay monitors the voltage level of a catenary power line for rolling stock used with electric railway equipment such as: Electric locomotives Any other electric traction vehicle with pantograph power supply. The relay is powered by the 1500 VDC pantograph voltage and its continuously energised while the line voltage is at least equal to the minimum authorised voltage. The relay opens when the line voltage drops below the authorised minimum. It has a time delay of a few milliseconds to offset pantograph bounce. Dielectric isolation between the terminals of the coil circuit and the contact terminals is 10KV 50HZ. The operating thresholds vary according to specifications. They are adapted to the catenary power supply networks. Hysteresis between the closing threshold and the opening threshold is very slight ( < 5% ). These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms NC NO + HV - 1329ST

10.&+-$',$),0# Application: This sensor measures the voltage level delivered by all the substations of electric railway equipment operating under 750VDC, 1500VDC or 3000VDC. The sensor is directly connected to the output of the substation rectifier bridge. It delivers a secondary current proportional to the input voltage: e.g. secondary 0/20mADC or 4/20mADC for primary 0/2000VDC. Dielectric isolation between the primary circuit terminals and the secondary circuit terminals can be 20KV 50HZ. This sensor is used primarily to guarantee galvanic isolation between the substation output voltage and the distribution board device indicating the voltage level. This equipment requires an auxiliary power supply rated according to specifications: e.g. 0/+24VDC or 220V 1121ST

&$,&'#$.+/'30#'207$#,(22./')$&70#<'10.&+-$'#+)-$ Application: This relay monitors the line voltage level of a catenary power supply for rolling stock of electrical railway equipment such as: Electric locomotives Any other electric traction vehicle with catenary power supply. The relay is powered by the 1500 VDC catenary voltage. It is permanently energised while the line voltage remains within the authorised voltage range. The relay drops out when the line voltage drops below the authorised minimum or exceeds the authorised maximum. It has a time-delay of a few milliseconds to offset pantograph bounce. Dielectric isolation between the coil circuit terminals and the contact terminals is 10KV 50HZ. The pick-up and drop-out values vary according to specifications. They are adapted to the catenary power supply network. Hysteresis between the pick-up values and drop-out values is very slight ( < 5% ). These relays are fitted with a NO contact and a NC contact with breaking capacity of 0.3A 90VDC L/R 20ms. NC NO + D1 _ 43 45 72 75 1431ST

24+,$',$=($)%$'*0)"&0#")-'#$.+/ Application: All industrial and railway three-phase networks The relay picks up when the three phases are connected in the direct rotation direction (clockwise) and drops out when a phase is cut. It cannot reset for inverted rotation of the phases even for a voltage 20% greater than the rated voltage. Dielectric isolation between the three-phase terminals and the contacts is 2.5KV 50HZ 1mn. The pick-up threshold voltage of the relay depends on the voltage of three-phase network. It is less than the minimum value of the voltage. The drop-out voltage threshold is 15% less than the pick-up voltage. These relays are fitted with a NO contact and a NC contact with breaking capacity of 2A 220V 50HZ. NC NO 1452ST

*0&0#'+.&$#)+&0#'2#0&$%&"0)',/,&$* Application: This system provides protection of the drive motor of a motor alternator supplying power to the rolling stock of electric railway equipment such as: Subway trains This system comprises a Hall-effect sensor measuring the power supply voltage of the unit motor ( 750VDC or 1500VDC ) and a signal processing card providing the following functions: Detection of the motor power supply low voltage to provide a load shedding function by suppressing loads at the alternator output. Detection of line voltage minimum and maximum values to enable closure of the motor power supply contactor. Detection of the line voltage du/dt to distinguish between a non-bridgeable interruption of line power and an in-line load demand in order to avoid current surge in the motor caused by additional power supply without a start-up cycle. This system requires a permanent auxiliary source (72VDC for example). Dielectric isolation between the HV input and LV outputs is 10KV 50Hz 1mn. The outputs are fitted with NO and NC contacts with breaking capacity of 0.3A 90VDC L/R 20ms. 1130ST

+.&$#)+&0#'*0)"&0#")-',/,&$* Application: This system monitors the three-phase outputs of a motor alternator supplying the auxiliary power to on-board railway equipment such as: Subway trains This system comprises 4 electronic circuits providing the following functions: Detection of under-frequency and over-frequency with a time delay to offset transient faults. Detection of under-voltage and over-voltage with a time delay to offset transient faults. Detection of current unbalance between phases with a time delay to offset transient faults. Detection of over-current with an inverse-time time delay to offset short over-current. This system requires a permanent auxiliary source connected directly to the threephase output of the alternator. Dielectric isolation between the alternator three-phase output and the unit outputs is 2.5KV 50HZ 1mn. The outputs are fitted with NO and NC contacts with a breaking capacity of 0.3A 90VDC L/R 20ms. 1/2

2/2

",0.+&"0)'3+(.&'!$&$%&"0)',/,&$* 30#'&4#$$524+,$')$&70#< Application: This system detects an isolation fault or loss of phase on the three-phase auxiliary circuit for electrical railway equipment such as: Subway trains Tramways Trolleybuses Electric locomotives The system comprises three relays and is powered by the three phases of a threephase inverter and an artificial neutral point connected to the ground. In the event of an ground fault or interrupt of one of the three phases, one of the three relays is energised causing the general circuit of the three-phase network to open. This system has been developed for safety applications preventing the re-injection of a 50Hz component on the current return rail to avoid disturbing train network signalling. Dielectric isolation between the terminals and the ground is 2.5KV 50HZ 1mn. The relays close for a phase interrupt or isolation fault 1500Ω in a voltage range of +/- 10% of the rated voltage. The response time is inversely proportional to the resistance value of the fault. The rated primary voltage varies from 200V to 400V 50HZ or 60HZ depending on requirements. These relays are fitted with a NO contact and a NC contact with a breaking capacity of 0.3A 90VDC L/R 20ms. U V W 1195ST

Australian Distributor Relay Monitoring Systems Pty Ltd 6 Anzed Court Mulgrave, Victoria, 3170, Australia Phone: +61 3 8544 1200 Fax: +61 3 8544 1201 Email: rms@rmspl.com.au Web: www.rmspl.com.au