SMART Application Structure Acoustics s n fa f o o R

Similar documents
Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

NCF fans 50 Hz. Protection class IP 55

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

MegaBox Product-specific information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

CHMT Series, F Rated Fans

GigaBox centrifugal fans Product specific information

HIGH-POWERED VENTILATORS

CGT Series Adjustable Pitch Fans

COMFORT AIR CURTAIN. SensAir

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CYCLONE F 400 smoke extraction casing

Industrial Mini Vent Sets

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CGT Series Adjustable Pitch Fans

Axial fans. What s more, non-stock models are normally available within two weeks.

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Vent-Axia Sabre Sickle Roof Fans (VSR)

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Extraction arm FX100 Original

Application. Dane techniczne. Structure

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

ACOUSTIC CABINET FANS CVAB / CVAT Series

COMFORT AIR CURTAIN. SensAir

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Short casing. Long casing (L version) Commercial premises

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

COMPACT Series type HCFB / HCFT (Plastic impellers)

JM Aerofoil Multi-Stage 50 Hz

Plate mounted axial flow fans HXBR / HXTR Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

ALSIDENT SYSTEM 50. A small flexible extraction arm

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

COMFORT AIR CURTAIN. SensAir

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

FAN & BLOWER CENTRIFUGAL FANS

CAST ALUMINUM PRESSURE BLOWERS

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

SERPENT. A complete ventilation system for successful tunneling and mining operations, including system design, fan station, ducting and installation.

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

Pipe connection All pump types have a treaded pipe connection: Rp2 1/2 for 6 WPS 16 N, Rp 3 for 6 WPS 30 N and Rp 4 for 6 WPS 45 N and 6 WPS 60 N.

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Novenco axial flow fans. ZerAx - Standard January 2010

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

TECHNICAL INFORMATION

F a n t y p e s J K K - J K K

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

FANS WITH ENERGY EFFICIENT EC TECHNOLOGY

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

NOVENCO FAN CATALOGUE

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CENTRIFUGAL IMMERSION PUMPS

Export Pricelist. Extraction rail type AS Exhaust rail, pipe connections. Extraction rail type AS Exhaust rail, Pipe Connections

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Sabre Plate Mounted Sickle Fans (VSP)

TECHNICAL INFORMATION

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

DC INVERTER VRF SYSTEMS C-VRF

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

MAJAX-2 GENERAL SPECIFICATION

AXIAL FANS & VANEAXIAL FANS


TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

Transcription:

Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature +60 C, and dustiness not exceeding 0,3 g/m³, without viscous, aggressive pollutants or substances that could cause explosion risk. The SMART family of fans, as a series of eight sizes of motor rates, ranges from 0,37 kw up to 7,5 kw and maximum 27. m³/h. Structure SMART fans, as unique among the examples on the market, are featured by original construction of bent steel profiles providing a skeleton of aerodynamic and at the same very robust properties. Inside is a motor with a radial impeller of aluminium and steel plate. The impeller is statically and dynamically balanced. The circumferential surface around the lower skeleton constitutes an openwork structure through which the air is discharged. The upper part of the fan is shielded by a hood made of a polyester-glass composite. The fan has to be mounted on a roof base. It is recommended to apply a sound absorbing roof base type TPD-N or TPDC-N of adequate size adapted to the given fan. Acoustics Low noise level was crucial in the design process of the SMART family of fans. This is the basic target of the KLIMAWENT Policy of Quality. Due to this, in the course of constructional works, several impellers, varying in shape, size, blade quantity and blade inclination, have been designed and prepared. All these impellers were submit to tests in the company Research Development Laboratory. In this course an impeller of the lowest noise level and optimal flow performances was finally selected. Complementary elements: TPD-N or TPDC-N sound absorbing roof bases on which the fans are mounted. The application of these roof bases reduces the noise getting to the room by 12 up to 18 d(a), silencers for the roof fans, which are suspended under the sound absorbing roof bases, inside the room.

Stylistics Could the fan additionally become decoration to the building, apart from the practical features? For sure SMART series is also fulfilling this aspect. The unique visual features consist in stylistics formed by the streamline shape and the four water drop-shape concaves in the laminate hood. Due to this, the fan experiences high approbation among the architects, as they are in harmony with the environment. As standard the fan is in light-grey colour. Efficiency adjustment On demand we offer inverters meant for adjustment of the rotational speed of the motors. The series of types of the inverters is represented in the section Electrical control units. Installing It is recommended to install the SMART fan on sound absorbing roof bases. The series of the roof bases matches the types of fans. The sound absorbing roof base is made of zinc-coated sheet. The inner surface is padded with a sound absorbing material. We offer two sorts of sound absorbing roof bases varying in the mode of mounting on the roof. TPD-N roof base mounted directly on the roof. In order to facilitate its installing on a roof of various inclination angle (0 up to 18 ), there are special support profiles rotatably placed on the opposite walls of the roof base, for levelling the mounting flange of the fan. TPDC-N roof base mounted directly on a roof pedestal of the ventilation duct, by screwing it to the mounting flange of the base.

Roof fan SMART-160/3000 Connection flange TPD-160-N TPDC-160-N Motor rate underpressure SMART-160/3000 812W40 3000 230 0,55 54 1900 970 20 TPD-160-N 843P40 - - - - - - 28 TPDC-160-N 843P50 - - - - - - 30 SMART-160/3000 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Roof fan SMART-200/3000 Roof fan SMART-200/1 SMART-200/1000 Connection flange TPD-200-N TPDC-200-N Motor rate underpressure SMART-200/3000 812W41 3000 230 0,55 54 2650 970 20 SMART-200/1 812W42 1 230 0,55 54 1870 740 40 SMART-200/1000 812W43 1000 230 0,37 54 1380 360 40 TPD-200-N 843P41 - - - - - - 28 TPDC-200-N 843P51 - - - - - - 30

SMART-200/3000 SMART-200/1 SMART-200/1000 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Roof fan SMART-250/3000 Roof fan SMART-250/1 SMART-250/1000 Connection flange TPD-250-N TPDC-250-N Motor rate underpressure SMART-250/3000 812W44 3000 230 0,55 54 3000 970 20 SMART-250/1 812W45 1 230 1,1 54 3130 820 44 SMART-250/1000 812W46 1000 230 0,37 54 2100 380 41 TPD-250-N 843P42 - - - - - - 41 TPDC-250-N 843P52 - - - - - - 46

SMART-250/3000 SMART-250/1 SMART-250/1000 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Roof fan SMART-315/3000 Roof fan SMART-315/1 SMART-315/1000 Connection flange TPD-315-N TPDC-315-N Motor rate underpressure SMART-315/3000 812W47 3000 230 0,55 54 3170 970 20 SMART-315/1 812W48 1 3 400 1,5 54 5020 980 58 SMART-315/1000 812W49 1000 230 0,37 54 3540 440 54 TPD-315-N 843P43 - - - - - - 41 TPDC-315-N 843P53 - - - - - - 46

SMART-315/3000 SMART-315/1 SMART-315/1000 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Connection flange TPD-400-N TPDC-400-N Motor rate underpressure SMART-400/1 812W50 1 3 400 3 54 8800 1120 75 SMART-400/1000 812W51 1000 230 0,75 54 5590 490 64 SMART-400/750 812W52 750 3x400 0,37 54 4770 260 63 TPD-400-N 843P27 - - - - - - 75 TPDC-400-N 843P54 - - - - - - 84 SMART-400/1 SMART-400/1 SMART-400/750 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Conection flange TPD--N TPDC--N Motor rate underpressure SMART-/1000 812W53 1000 3 400 2,2 54 11055 789 105 SMART-/750 812W54 750 3 400 1,1 54 7850 400 98 TPD--N 843P45 - - - - - - 75 TPDC--N 843P55 - - - - - - 84 SMART-/1000 SMART-/750 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Roof fan SMART-630/100 SMART-630/750 Connection flange TPD-630-N TPDC-630-N Motor rate underpressure SMART-630/1000 812W55 1000 3 400 5,5 54 19920 1110 179 SMART-630/750 812W56 750 3 400 3 54 15520 600 172 TPD-630-N 843P46 - - - - - - 88 TPDC-630-N 843P56 - - - - - - 100 SMART-630/1000 SMART-630/750 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Roof fan SMART-710/100 SMART-710/750 Connection flange TPD-710-N TPDC-710-N Motor rate underpressure SMART-710/1000 812W57 1000 3 400 7,5 54 27580 1260 212 SMART-710/750 812W58 750 3 400 3 54 19790 690 177 TPD-710-N 843P47 - - - - - - 88 TPDC-710-N 843P57 - - - - - - 100 SMART-710/1000 SMART-710/750 Caution: These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Application BULLET-type roof fans are meant for general ventilation of buildings. They have been developed for conveying dry air of maximum temperature +40 C, of dustiness not exceeding 0,3 g/m³, without viscous impurities, aggressive compounds or substances causing explosion risk. The series of fans consists of four sizes of subsequent connection diameters 160, 200, 250, 315 mm. Structure BULLET consists of a cylindrical aluminium housing, with a radial impeller inside and a motor. The fan housing is protected by a polyester-glass composite hood. The outlet is directed downwards to the roof. The fan has to be installed on a roof base by means of a flange fastened to the inlet ferrule. It is recommended to install the fan on a sound absorbing roof base type TPD-N or TPDC-N, eventually on typical bases type BI or BII. On demand we offer speed governors type RP for a stepless adjustment of the rotational speed. As standard the fans are manufactured in light-grey colouring. Motor rate underpressure BULLET-160 807W55 3000 230 58 44 650 310 6,0 BULLET-200 807W56 3000 230 135 44 1000 510 7,0 BULLET-250 807W57 3000 230 135 44 1400 550 8,0 BULLET-315 807W58 3000 230 255 44 2150 610 8,3 A A1 B C D BULLET-160 194 (6 07) 160 538 460 80 BULLET-200 224 (8 09) 200 538 460 80 BULLET-250 274 (8 09) 250 538 460 80 BULLET-315 344 (8 09) 315 538 460 80

BULLET-160 Flow characteristics Acoustic characteristics Acoustic characteristics Static pressure Noise level [db(a)] from distance 1m 5m Noise level [db(a)] from distance 1m 5m Volume flow Volume flow Volume flow BULLET-200 Flow characteristics Acoustic characteristics Acoustic characteristics Static pressure Noise level [db(a)] from distance 1m 5m Noise level [db(a)] from distance 1m 5m Volume flow Volume flow Volume flow BULLET-250 Flow characteristics Acoustic characteristics Acoustic characteristics Static pressure Noise level [db(a)] from distance 1m 5m Noise level [db(a)] from distance 1m 5m Volume flow Volume flow Volume flow BULLET-315 Flow characteristics Acoustic characteristics Acoustic characteristics Static pressure Noise level [db(a)] from distance 1m 5m Noise level [db(a)] from distance 1m 5m Caution: Volume flow Volume flow Volume flow These above characteristics have been carried out for the fans installed on a TPD-N or TDPC-N sound absorbing roof base. In order to reduce the noise level additionally a TK silencer can be suspended under the TPD-N or TPDC-N roof base.

Application Roof fans are used for general ventilation or local extraction. They are reliable and efficient in application with ventilation systems and local exhausts because of the increased fan pressure, in comparison with traditional roof fans. Fans are designed for conveying the dry air of dustiness not exceeding 0,3 g/m³, without viscous, aggressive impurities and compounds causing explosion risk. Structure The fan consists of spiral housing, radial impeller, flange motor and a steel hood. The distinctive feature of the fan is a silencer mounted at the housing outlet. The fan inlet is equipped with a connection with flange and therefore it is possible to install it on a roof base as well on a special wall bracket. WP-5-D 475 WP-5-D Ø 160 Ø 256 Fan pressure pressure 4000 3000 2000 1000 60 6 holes Ø6,5 Ø 160 Ø 194 max 900 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow WP-7-D 490 WP-7-D Ø 200 Ø 307 Fan pressure pressure 4000 3000 2000 1000 60 6 holes Ø6,5 Ø 160 Ø 194 max 960 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow WP-8-D 505 WP-8-D Ø 200 Ø 307 Fan pressure pressure 4000 3000 2000 1000 60 8 holes Ø 9 Ø 224 985 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow WP-9-D 575 60 8 holes Ø 9 Ø 224 1025 WP-9-D Ø 200 Ø 307 Fan pressure pressure 4000 3000 2000 1000 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow

WP-10-D 695 WP-10-D Ø 250 Ø 360 Fan pressure pressure 4000 3000 2000 1000 60 8 holes Ø 9 Ø 250 Ø 274 1030 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow WP-11-D 695 WP-11-D Ø 250 Ø 360 Fan pressure pressure 4000 3000 2000 1000 100 8 holes Ø 9 Ø 250 Ø 274 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow WP-13-D 745 WP-13-D Ø 315 Ø 410 Fan pressure pressure 4000 3000 2000 1000 110 8 holes Ø 11 Ø 315 Ø 344 1465 750 400 300 200 200 300 400 1000 2000 3000 4000 0 10000 10 Volume flow Motor rate Noise level [db(a)] from distance 1 m 5 m vacuum WP-5-D 807W25 3000 230 0,55 54 75 66 2200 1400 29 WP-5-D 807W26 3000 3 400 0,55 54 75 66 2200 1400 29 WP-7-D 807W27 3000 230 1,1 54 80 73 3 1800 36 WP-7-D 807W28 3000 3 400 1,1 54 80 73 3 1800 36 WP-8-D 807W30 3000 3 400 1,5 54 83 76 3 2200 40 WP-9-D 807W32 3000 3 400 2,2 54 85 78 4000 2800 50 WP-10-D 807W33 3000 3 400 3,0 54 86 81 8000 2 60 WP-11-D 807W34 3000 3 400 4,0 54 87 82 9000 2800 69 WP-13-D 807W35 3000 3 400 6,0 54 89 84 11000 3100 95 1. Motor protective switches, rotational governors, installation equipment are in cards ACCESSORIES p.56. 2. temperature of the forwarded air +60 C. temperature in the work area +40 C. 3. dustiness of the transported air should not exceed 0,3 g/m 3. Roof base BII ACCESSORIES p.156-157 Wall bracket WBN Silencer TK for the inlet