V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Silent centrifugal air heater hot water supply

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Performance. Sound Levels. Impellers. Motors. Accessories

CGT Series Adjustable Pitch Fans

Sabre Plate Mounted Sickle Fans (VSP)

CGT Series Adjustable Pitch Fans

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

NCF fans 60Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Short casing. Long casing (L version) Commercial premises

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ACOUSTIC CABINET FANS CVAB / CVAT Series

NCF 60 Hz. Protection class IP 55

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

IN-LINE CENTRIFUGAL DUCT FANS VT Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Heat recovery units type GTDHR

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Vent-Axia Sabre Sickle Roof Fans (VSR)

CYCLONE F 400 smoke extraction casing

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

TGT Series Adjustable Pitch Fans

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Unobox units with backward curved centrifugal impellers

Powerful centrifugal fans for universal use: The product ranges TEM and REM

AXIAL FANS Catalogue CN0050C01 May 2008

ACOUSTIC CABINET FANS CVB / CVT Series

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

VORTICENT C E RANGE Centrifugal fans

CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES

F a n t y p e s J K K - J K K

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

CHMT Series, F Rated Fans

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CYLINDRICAL CASED AXIAL FLOW FANS

TGT Series Adjustable Pitch Fans

Fan coil units MAJOR 2 CV/CH

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

BELT DRIVEN CABINET FANS CVTT Series

Plate mounted axial flow fans HXBR / HXTR Series

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Mixed Flow Roof Fans (RMH)

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

ROOFMASTER STEF-HT ROOF FAN

FAN & BLOWER CENTRIFUGAL FANS

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CVHT Series - F rated cabinet fans

Sentinel D-Box Single Fan

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Sentinel D-Box Twin Fan

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Powerful centrifugal fans for universal use: The product ranges TEM and REM

GigaBox centrifugal fans Product specific information

Horizontal Cartridge DUST COLLECTOR OPF

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

Specifications ROOF MOUNTED SEAT SERIES. ATEX version. 1 - Roof unit kit. 2 - Enclosed pedestal. Roof unit kit includes:

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

VCPA Plastic Centrifugal Fan Air Flows up to 6,000 CFM and static pressures to 10 inches w.c.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

MAJAX-2 GENERAL SPECIFICATION

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CENTRIFUGAL FAN COIL UNIT VCE

BRIZA 22 HYBRID HEATING & COOLING

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

TORIN by: AIRDEX Index Page No.

Transcription:

Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings, for clean air at a maximum temperature of 40 C. They can be installed inside or outside the buildings. RANGE 7 sizes covering an air flow rate range from 0.11 to 9.72 m 3 /s at high available pressures. Sizes 7-9 - 10-12 are equipped with direct coupling fan motors. Sizes 35-45 - 56 are equipped with direct drive pulley/belt assembly fan motors. DESIGN Casing Self-supporting reinforced panels made of grey lacquered (RAL 7024) corrosion-proof galvanised sheet metal. Removable panels for access to motor fan unit. Galvanised sheet steel fan motor unit Statically and dynamically balanced forward curved blade impeller. models 7-9 - 10-12 - single-phase motor 230 V - 50 Hz direct coupling - flow rate / pressure variation with voltage variator (optional). models 35-45 - 56 - pulley/belt assembly. three-phase motor - 50 Hz. IP 55 motors - class F - tropicalised with thermal protection. OPTIONS AND ACCESSOIRES MOUNTING Anti-vibration mounts M0 air intake flexible M0 air discharge flexible Air intake circular sheet metal Air discharge circular sheet metal Rain guard and bird-proof screen on intake side Rain guard and bird-proof screen on discharge side G2 or G4 filter Proximity switch Pressostat Circuit breaker Voltage variator Frequency variator 2-speed control box ELECTRICAL AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A 1

SELECTION CURVES Static pressure : pressure level in db(a) measured at 5 m in a room with average reverberation. Intake and discharge outlets connected. Precision 3 db(a). To obtain the power level, add 15 db to the values written on the curves. 2 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A

VENTILATION BOXES Direct coupling motor fan units 1-speed motor - single phase 230-50 Hz - IP 55 - Class F - Tropicalised 7 9 10 12 Code B342475 B342483 B342491 B342505 Variable speed drive Code 0593209 0593210 Direct drive fan motor assembly 1-speed motor - 4 poles - Three phase 230/400V* - 50 Hz - IP 55 - Class F - Tropicalised Motor power in kw 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 35 45 56 Code B342513 B342556 B342572 B342599 B344516 B344524 Code B342564 B342580 B342602 B342629 B342645 B344532 B344540 Code B342610 B342637 B342653 B342661 B342688 B344559 * Three-phase 230 / 400 up to 4 kw or 400 / 700 V from 5.5 kw Direct drive fan motor assembly 2-speed motor - 4/8 poles - DAHLANDER coupling - Three phase 400V - 50 Hz - IP 54 - Class F - Tropicalised Motor power in kw 0,75/0,12 1,5/0,25 2,2/0,37 4/0,75 5,5/1,1 7,5/1,5 11/2,8 35 45 56 Code B342750 B342696 B342726 B344567 Code B342718 B342734 B342831 B344575 B344583 Code B342742 B342858 B342882 B342912 B344591 Supplement for built-in filtration kit 7 9 10 12 35 45 56 Efficiency G2 Code B344656 B344664 B344672 B344680 B344699 B344702 B344710 65 % ASHRAE gravimetric test Efficiency G4 Code B344729 B344737 B344745 B344753 B344761 B344788 B344796 90 % ASHRAE gravimetric test Electrical characteristics of motors - MODELS 7-9 - 10-12 7 9 10 12 W 147 550 550 736 Polarity 4 4 4 6 IN in A 1,7 4,9 4,6 7,2 Models 35-45 - 56 kw 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 0.75/0.12 1.5/0.25 2.2/0.37 4/0.75 5.5/1.1 7.5/1.5 11/2.8 1 speedmotor * 2 2.5 3.6 5.1 7.2 9.1 11.9 15.2 21.1 motor * 2.3/0.9 4/1.5 5.5/2.2 8.9/3.2 11/3.7 15.3/5 21.5/7.7 2-speed IN in A 4P motor * Characteristics in 3 ph - 400 V - 50Hz - Indicative values as per motor manufacturer s catalogue. Dimensioning of protection devices must be done according to the rating affixed on the motor mounted on the unit. AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A 3

DIMENSIONS Drilling for diam. 5.5 self-tapping screw G2 or G4 filter option (th. 48) 4 diam. 9.1 holes Drilling for diam. 5.5 self-tapping screw A B C D E F G H J K L M N P a b c d e f g h j k Mass maxi kg 7 520 400 500 240 240 420 300 140 93.5 66.5 50 50 546 450 1 270 0 1 270 0 2 225 2 165 25 9 605 455 550 299 299 505 355 153 99 57 50 50 631 500 0 0 164.5 0 0 164.5 2 267.5 2 192.5 34 10 700 505 600 333 333 600 400 183.5 116.5 55.5 50 52.5 726 550 0 0 181.5 0 0 181.5 2 315 2 215 40 12 800 600 700 415 415 700 500 192.5 119.5 65.5 50 50 826 650 1 125 160 1 125 160 3 243.3 2 265 61 Drilling for diam. 5.5 self-tapping screw G2 or G4 filter option (th. 48) 4 diam. 9.1 holes Drilling for diam. 5.5 self-tapping screw A B C D E F G H J K L M N P a b c d e f g h j k Mass maxi kg 35 1000 700 1100 464 464 900 600 268 181 55 50 50 970 1070 1 125 184.5 1 125 184.5 3 310 3 210 112 45 1400 1100 1300 574 574 1200 900 413 312.5 213.5 100 100 1370 1270 1 250 177 1 250 177 4 307.5 3 310 195 56 1400 1400 1500 724 724 1200 1200 338 362.5 313.5 100 100 1370 1470 3 125 189.5 3 125 189.5 4 307.3 4 307.5 285 Gound fixation Note : only the unit fixed on the ground can be equipped with anti-vibration mounts. The units must always be installed with the fan axis in the horizontal position. 4 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A

ACCESSORIES Inlet M0 flexible 7 9 10 12 35 45 56 code B355909 B355917 B355925 B355933 B355941 B355968 B355976 Discharge M0 flexible code B355984 B355992 B356018 B356026 B356034 B356042 B356050 Inlet metal sheet circular code 2844895 2844896 2844897 2844898 2844899 2844900 2844901 Inlet circular M0 flexible code B356069 B356077 B356085 B356093 B356107 B356115 B356123 code 2844877 2844878 2844879 2844880 2844881 2844882 2844883 Rain guard and screen on the air intake AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A 5

ACCESSORIES 7 9 10 12 35 45 56 code 2844884 2844886 2844887 2844889 2844890 2844892 2844894 Rain guard and screen on the air intake code 0218027 0218027 0218027 0218028 0218031 0218032 0218032 Anti-vibration mounts (per set) A 480 565 660 760 960 1260 1260 B 360 415 460 560 660 960 1260 Dimensions C 300 359 393 475 514 634 784 D 250 355 400 500 560 900 1120 E 260 290 310 365 415 560 710 F 220 270 290 350 410 495 610 6 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.566 A