Guidance to Installers of Viridian EV Charging Stations

Similar documents
User Guide for Viridian EV Charging Stations

Installation manual wall-mounted distributor

Installation manual portable distributors

LED emergency exit signage from Channel Safety Systems

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Installation and Maintenancee Manual

PSU1 Power Supply Unit

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service

ZonePlus Z322 zone valve Installation and commissioning instructions

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Single Phase Electronic Speed Controllers

LED Emergency Luminaires

Owner's/Installation Manual

Enelion Vertica. Installation manual. 22 kw. for the specialists

The Powermatic User Guide Test Sieve Shaker

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

System Monitoring SCHOOLMETERBOX AU

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pay For Water System DU 1A046A

RESTWELL RISE & RECLINE ARMCHAIRS LARS AND SVEN - OWNER S HANDBOOK MODEL DESCRIPTION

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions For Motor Control Center (MCC) Units

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Wind Power Inverter WINDY BOY 5000A/6000A

PHEV Conversion Kit User Manual

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

DC Master 24/ A

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Roller Door Operator

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

HOME BOX EV CHARGING STATION WITH FIXED CABLE

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

Technical Manual. DLM Module. This manual should remain with the unit.

3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

Technical Manual POD Point

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Instruction Manual. Q Series 2 Motor Control Modules - OEM

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

Boring Unit Sitework Systems Attachment

Operating Instructions

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

B DUAL DRUM SANDER

OPERATING INSTRUCTIONS

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

PHEV Conversion Kit User Manual

ibusway for Data Center

MODEL 2604 WARNING <THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> Custom 5th Wheel Hitch Mounting Rail Installation Instructions

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

PSU EN54-4 Power Supplies

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model ACS

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

Fuse state indicator MEg72. User manual

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

VT Oil-Free Range Operators Handbook

Battery Charger Series EASY Charger

i-energy i-micro inverter GT260

Consists of. Date:17/02/2011 Page 1/8

Installation Power Management Unit Battery Cables and Battery Harness

SERVICE MANUAL. Koala

INSTRUCTIONS FOR USE

SUS9 Swing Away Series

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

Battery Charger. Series EASY Charger. User s manual

INSTRUCTION MANUAL SINKER. By HAY

Stealth Power i-tilt

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

82V LITHIUM-ION BATTERY CHARGER GC 400

Operators Guide: RoboSign Stop/Go Traffic Control System

easyflow-vs Variable Speed Peristaltic Dosing Pump

IR600 Infra-red Lamp


PM - Projector Mount System

BlinkerBeam SL80 Controller User Guide

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> Custom 5th Wheel Hitch Mounting Rail Installation Instructions

SUS9 Swing Away Series

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Transcription:

Guidance to Installers of Viridian EV Charging Stations

Iss 6 - Jul 2016 Page 2 of 9 This guide is intended to instruct in the proper installation of a Viridian EV Charging Station. Please note that when installing this equipment care must be taken to ensure that all, local and national safety and planning requirements are met. INSTALLATION OF THIS EQUIPMENT SHOULD ONLY BE CARRIED OUT BY A FULLY QUALIFIED INDIVIDUAL. VIRIDIAN EV ACCEPTS NO RESPONSIBILITY FOR DAMAGE CAUSED BY IMPROPERLY INSTALLED EQUIPMENT. Cautions and Dangers This guide contains several instructions to which the following symbols have been attached. Failure to comply with instruction could result in: DANGER Indicates where failure to comply with instructions will cause death or serious injury. WARNING Indicates where failure to comply with instructions could lead to death or serious injury. CAUTION Indicates where failure to comply with instructions could lead to minor or moderate injury. This document is intended to instruct in the installation of all models of Viridian manufactured charging stations (current model numbers at the time of writing listed below). Instructions specific to particular models will be highlighted and clearly marked. M03-T1C-16A-1P M03-T2C-16A-1P M03-T2S-16A-1P M07-T1C-32A-1P M07-T2C-32A-1P M07-T2S-32A-1P M12-T2C-16A-3P M12-T2S-16A-3P M22-T2C-32A-3P M22-T2S-32A-3P Understanding the model number of your charging station Enclosure Type Example: Metal Enclosure Connector Type Example: Type 2 Maximum Available Current per phase Example: 32A M07-T2S-32A-1P Approximate maximum available power in kwh Example: 7kWh Socket or cable (Socket type 2 only) Example: Socket Number of phases Example: Single Phase

Iss 6 - Jul 2016 Page 3 of 9 WARNING The charging station is designed for electric vehicle (EV) charging only. It is designed to only allow the flow of electricity once an EV is connected and correct communication is established. Any tampering of the charging station to allow the flow of electricity at any times other than this will present a risk of electric shock. CAUTION The Charging station is covered by a manufacturers parts and labour warranty. Alterations to the charging station that are not permitted will invalidate this warranty. Fig. A - Charging Station Features 2 5 1 1 3 4 6 1. The charging station connects to an EV via the attached vehicle coupler (shown right) or via the socket (shown left). Models fitted with sockets allow the use of a range of approved interconnecting cables. 2. Integrated RCBO 3. Status LED 4. Cover strips 5. Identification label 6. Socket drainage tube

Iss 6 - Jul 2016 Page 4 of 9 Model Number Charging Current Serial Number Fig. B - Identification label breakdown Mounting of the charging station The charging station should be mounted vertically on either a post or a wall. The position of the charging station should allow all main functions of the charging station to be accessible between 750mm and 1200mm of the ground in accordance with BS8300:2009, unless otherwise instructed not to. The charging station has four integrated mounting holes that are accessible by removing the cover strips (Fig. A - 4). Internal components Mounting hole 1. Contactor 2. RCBO 3. EPC 4. Mains input Earth terminal 5. Main charging station earth point. 6. Label stating the equipment must be earthed 6 Fig. C Inside the box

Iss 6 - Jul 2016 Page 5 of 9 Installation method DANGER Installation requires access to the properties electrical consumer unit. Ensure that power to it is isolated before commencing any work. WARNING Due to the high and constant current draw, the charging station must be installed on a dedicated spur within the consumer unit. CAUTION The charging station must be installed in accordance with all current safety and legislative requirements relevant to the location to which it is being installed. If any of the actions listed by the installation method described below contravene current safety and legislative requirements, they MUST be adjusted to meet the required standard. If that is NOT possible they MUST NOT be done. THE INSTALLER MUST ENSURE THE CHARGING STATION IS EARTHED It is recommended but not required that an isolation switch should be located near the charging station. Plastic hinges have been provided with the charging station for optional fitting to the two rightmost slots under the cover strips (Fig. A - 4). These hinges allow the front panel of the charging station to hinge to the right of the rear casing allowing work to be carried out on the unit without removal of the front panel. Install a MCCB within the consumer unit that is appropriately rated for the charging station(s) that is being installed. Drill an appropriate sized hole on the side of the charging station for a cable gland, ensuring that no damage is done to any internal components or wiring and removing any burrs and swarf that may have been generated in the process. The cable gland used must be suitably rated for the location of the charging station. The charging station should be secured to a wall or post as described on page 4. Pass a suitably rated cable for the current draw, cable length and cable chasing method directly* from the consumer unit through the gland and connect LIVE and NEUTRAL to the correct terminals of the RCBO (Fig. C - 2). The terminals should be tightened to between 2.5 and 3Nm. For three phase charging stations ensure that all 3 LIVE are connected to the correct terminals *If you are carrying out an OLEV approved install, an external energy meter is required between the charging station and consumer unit. It is recommended that you use an Emlite ASLH 382. The Emlite must be positioned in a suitable location to receive a GSM signal Connect the EARTH to the mains input earth terminal (Fig. C - 4) THE INSTALLER MUST ENSURE THE CHARGING STATION IS CORRECTLY EARTHED.

Iss 6 - Jul 2016 Page 6 of 9 Inspect ALL other connections as these may have become loose in transit. For all T2S type chargers connect the drain tube supplied to the bottom of the socket (Fig. A 6) pulling the excess liquid through to the outside of the charging station. Close and secure the lid using the four supplied captive screws. Replace the cover strips. Ensure all cables connected to the charging station are suitably secured. Re-establish the electrical connection and test the RCBO for correct operation. The status LED should be flashing blue to indicate that the charging station is ready to charge Test the operation of the charging station on an EV simulation box and if possible the customers EV. It is recommended that you notify the local DNO that you have completed a charging station install. This MUST however be done on an OLEV approved install. If this is a second charging install, you must state both this and the combined current rating of both chargers. If at any time during the install the charging station is damaged you MUST stop the current installation and restart it using a new charging station. On completion of the install, please ensure o The customer receives the User Guide for Viridian EV Charging Station leaflet. o The customer receives a demonstration on how to use the charging station and its features. o You demonstrate the RCBO test function and instruct them to do this monthly. o The customer is shown how to isolate the power to the charging station in the event of an electrical fault. o The customer receives information on the warranty and what to do in the event of a claim. o The customer receives your contact details in case of any issues that may arise within the warranty period. (A space has been provided at the back of the User Guide for Viridian EV Charging Station leaflet) o For OLEV installations: A note is taken of the Emlite meter serial number and the charging station serial number (optionally: the customer s name and address). Direct these to team@viridianev.energy at your earliest convenience. (Forwarding the photos taken for OLEV s requirements is suitable method). o For OLEV installations: Permission is obtained if passing the customer s name and address back to us, the manufacturer, for the purpose of record keeping and identifying the installations. 1

Iss 6 - Jul 2016 Page 7 of 9 1 The information will never be passed on to any other party or company. The information will also enable us to produce usage data for users of our charging stations if requested. Service and maintenance DANGER Contact with live components can result in serious injuries. Isolate the power before commencing any work. THERE ARE NO USER SERVICEABLE COMPONENTS WITHIN THIS CHARGING STATION. Please note that even though every care has been taken to select only the highest quality components, in the event that you should experience problems with this unit servicing should only be carried out by a suitably qualified individual. As the charging station is modular in design the affected component can be replaced on site with the defective part being sent back to the manufacture for analysis. Procedure Cleaning Isolate all power to the charging station. Disconnect the wiring from the affected component by loosening the terminals. Remove the device by pulling the locking slider and swivel the device away from the DIN rail. Install a new device by placing it over the DIN rail and firmly pushing it down until it clicks into place. Reconnect all wiring and check that all connections are tightened to the required torque. Re-establish the power supply to the charging station. It is recommended that cleaning of the outside of the charging station should be performed using a damp cloth and a mild cleaning solution. CAUTION Cleaning the charging station with a high-pressure water hose is not permitted and could cause water build up within the charging station. The charging station should not be opened and cleaned internally.

Iss 6 - Jul 2016 Page 8 of 9 -- -- THIS PAGE INTENTIONALLY LEFT BLANK-- --

Iss 3 - JUL 2015 Page 9 of 9 Viridian EV 42 Elliott Road, Love lane Industrial Estate, Cirencester, Gloucestershire GL7 1YS Tel: +44 (0)177 230 7172 Web: www.viridianev.co.uk Email: info@viridianev.co.uk Viridian EV is a trading name of EcoHarmony Ltd.