CATALOGUE. Flowmeters Measurement systems kids Filters. Group of industrial companies «EMIS»

Similar documents
Metal tube variable area flowmeter for gases, liquids and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

VersaFlow Vortex 100 Vortex Flow Meter Specifications

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Magnetic-inductive flow meter for hazardous areas

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

ISTEC MAGNETIC METERS

VLM20 In-line Vortex Flowmeter

F-2600 SERIES INLINE VORTEX FLOW METER

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Thermal Gas Mass Flowmeter Series TMF-300

VIM20 Vortex Insertion Flowmeter

HH5 Variable Area Flow meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Plastic tube variable area flowmeter for liquids and gases

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Model TUR-200D Turbine Flowmeter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Multivariable Vortex Flow Meter

Liquid Turbine Flow Meter OwnerÊs Manual

Vortex Flow Meter Model DVH

F-2700 SERIES INSERTION VORTEX FLOW METER

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

mass flowmeter for compressed air

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Electromagnetic Flowmeters. Product Overview.

Multivariable Vortex Flow Meter

Food & beverage. Oil & gas. Water & waste water

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

STEEMCO-MAS Flowmeter for Steam

PRODUCT IDENTIFICATION & COMPANY

VIM20 Vortex Insertion Flowmeter

Turbine flowmeters Series TM

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Armstrong In-Line and Insertion Vortex Flow Meters

VIM20 Vortex Insertion Flowmeter

F-2600 SERIES INLINE VORTEX FLOW METER

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

F-2500 SERIES VORTEX METER

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Range of Ultrasonic Flowmeters.

The readings you need, right where you need them. AX Series Vortex Meters

TORRIX Magnetostrictive level sensor

mass flowmeter for compressed air

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Vortex Flowmeter Model DVE

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

DY-LWGY Liquid turbine flow meter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Smart Pressure Transmitter

RIM20 Rotor Insertion Flowmeter

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

OPTIMASS 3000 Technical Datasheet

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Magnetic Inductive Flowmeter EP / UMF2 (B)

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

MagFlux Q 8200 Series

Smart Pressure Transmitter

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

LC OVAL GEAR FLOWMETER

Fuel level sensors Strela - Users manual. Fuel level sensors Strela. Users manual

4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

SINGLE-TURN AND MULTI-TURN ELECTRIC ACTUATORS

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

OPTIMASS 2000 Technical Datasheet

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

Flow VA 550 / 570. DVGW tested. Flow.

STEEMCO Flowmeter for Steam

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Transmitting Transducer. Gas/Air Velocity Range:

Transcription:

CATALOGUE Flowmeters Measurement systems g skids skid kids Metering Filters Asso so ociatte oc ted ed equipm eq e iip pm m n men ntt Associated equipment 2014 Group of industrial companies «EMIS»

table of contents FLOW SMART VORTE FLOWMETER EMIS-VIHR 200 4 Vortex flowmeter (for formation pressure maintenance) EMIS-VIHR 200 PPD 6 INSERTION VORTE FLOWMETER EMIS-VIHR 205 8 VORTE BOREHOLE FLOWMETER EMIS-VIHR 200-SKV 10 PLASTIC ROTAMETER EMIS-META 210 11 METAL ROTAMETER EMIS-META 215 12 ELECTRONIC FLOWMETER FOR LIQUIDS EMIS-PLAST 220 14 ELECTRONIC FLOWMETER FOR LIQUIDS WITH INTEGRATED FLOW CONTROLLER EMIS-PLAST 220R 16 HIGH ACCURACY ROTOR FLOWMETER FOR LIQUIDS EMIS-DIO 230 18 OVAL GEAR METER EMIS-DIO 230L 20 MASS FLOWMETER EMIS-MASS 260 22 MAGNETIC FLOWMETER EMIS-MAG 270 24 PADDLE TYPE FLOW SWITCH EMIS-POTOK 236 27 THERMAL DISPERSION FLOW SWITCH EMIS-POTOK 285 27 EMIS DEEP-WELL RESEARCH COMPLE 29 ENERGY CARRIER METERING SKID EMIS-ESKO 2210 30 METERING SKID WITH SELF-CONTAINED POWER SUPPLY UNIT EMIS-ESKO 2210-AIP 33 FLOW CONDITIONERS / STRAIGHTENERS EMIS-VEKTA 1200 34 LIQUID FILTERS EMIS-VEKTA 1210 35 GAS FILTERS EMIS-VEKTA 1215 37 FILTER-SEPARATOR EMIS-VEKTA 1212 38 INSERT PIPES EMIS-VEKTA VT 40 ORIFICE PLATES FOR FLOWMETERS DKS, DBS, DFK 41 LEVELING VESSELS, SEPARATION VESSELS AND CONDENSING VESSELS 42 PRESSURE VALVE BLOCKS FOR PRESSURE SENSORS EMIS-VEKTA 1100 43 PRESSURE REDUCING VALVE EMIS-VEKTA 44 SYSTEM COMPONENTS PULSE POWER SUPPLY UNIT EMIS-BRIZ 60 45 TRANSFORMER POWER SUPPLY UNIT EMIS-BRIZ 90 48 RS-485 INTERFACE CONVERTER EMIS-SYSTEMA 750 47 INTRINSIC SAFETY BARRIERS BIS-A-111-E 47 SERVICES SELECTION, ENGINEERING, SUPERVISING INSTALLATION, INSTALLATION OF EMIS INSTRUMENTS 48 VERIFICATION OF LIQUID FLOWMETERS 49 Flow measurement and automatization page 3

catalogue-2014 EMIS-VIHR 200 SMART VORTE FLOWMETER EMIS-VIHR 200 Applications Suitable for commercial and industrial metering of associated petroleum gas, saturated and overheated steam, natural gas, compressed air, oxygen, hydrogen and other industrial gases. It is also used to measure the volume flow, water solutions and other liquids, including polluted liquids and different liquid compositions. Certificate of approval for almost all industries. Flow ranges* DN, mm Liquids, m 3 /h Gas/Steam, m 3 /h 15 0,2 5 3,2 32 25 0,4 16 3,5 120 32 0,6 26 6 200 40 1 41 9 310 50 1,4 64 14 480 65 2,6 107 24 810 80 4 160 36 1230 100 6 250 60 1920 125 10 400 90 3000 150 14 575 130 4325 200 26 1060 235 8000 250 42 1700 380 12900 300 60 2460 550 18600 * the lower limit of gas and steam flow depends on operating conditions. Flow ranges are specified for maximum process temperature 100 С. Specifications Process fluids... gas, steam, liquids Process fluid temperature... -200 C to 460 C Process pressure...to 25MPa Pipeline DN...15mm to 300mm Dynamic range...up to 1:46 Accuracy (liquids)... ±0,5% Accuracy (gas/steam)... ±1,0% Output signals...1000hz / 4-20mA /RS485/USB Explosion proof... 1ExibIIB(T1-T5) / 1ExibIIC(T1-T5)/ 1ExdIIC(T1-T5) / РВ ExdI Power supply... 10V DC to 30V DC Ambient temperature... -50 C to 70 C Water and dust ignition-proof... IP65 Verification interval... 4 years Features & advantages Wide dynamic range High metrological stability of measurement Stable work under high temperature Low pressure loss With no moving parts Durable and reliable in service Hydroblow resistant Large amount of maintenance works are not required permits remote data communication, configuration, testing through RS-485 Modbus RTU Flow-calibrated on liquid flow test stand Explosion proof PB ExdI «Simulation» diagnostics are available Optional specifications Item Description EMIS-VIHR 200.CK Connection kit (cast steel flanges, gaskets, bolts, stud bolts, screw nuts, washers) EMIS-VIHR 200.CK-N EMIS-VEKTA VT200 EMIS-VIHR 200.KIP EMIS-BRIZ Connection kit (stainless steel flanges, gaskets, bolts, stud bolts, screw nuts, washers) Insert pipes for installation use Cable kit for simulation diagnostic needs Power supply unit!attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. page 4 http://www.emis-kip.ru/prod/ev200

EMIS-VIHR 200 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Order EMIS-VIHR 200 - Vn - 050 - A - - - Zh - H - FR - - - 2,5-250 - - - A - GP 1 Type of explosion protection Standard* - Without explosion protection (standard) ExB Explosion-proof class 1ExibIIB (T1-T5) ExC Explosion-proof class 1ExibIIC (T1-T5) (special order) Vn Flameproof enclosure 1ExdIIC(T1-T5) PB Explosion proof PB ExdI 2 Nominal Diameter 015 DN = 15 mm (only for 100 С) 100 DN=100mm 025 DN=25mm 125 DN=125mm 032 DN=32mm 150 DN=150mm 040 DN=40mm 200 DN=200mm 050 DN=50mm 250 DN=250mm 065 DN=65mm 300 DN=300mm 080 DN=80mm 3 Accuracy A Class A(nominal accuracy for liquids ± 0,5%, for gas and steam ± 1,0%) B Class B(nominal accuracy for liquids ± 1,0%, for gas and steam ± 1,5%) 4 Flow range - Standard, according to User Manual Specail order 5 Process fluid Zh Liquid G Gas, saturated steam, overheated steam K Oxygen 6 Process-Wetted Materials H Stainless steel c Hastelloy analogue 7 Pipeline connections S Wafer type (DN from 15 to 100 mm) F Flange type FR Flanged Reducer type (DN from 25 to 100 mm) 8 Electronic transmitter type - Integral type (sensor and electronic transmitter are mounted together) D Remote type electronic transmitter (cable length 3 m) D Remote type electronic transmitter (with customer-specified cable length, for example, R08) 9 Process fluid pressure 1,6 Maximum pressure up to 1,6 MPa 2,5 Maximum pressure up to 2,5 MPa 4,0 Maximum pressure up to 4,0 MPa 6,3 Maximum pressure up to 6,3 MPa 20 Maximum pressure up to 20 MPa 25 Maximum pressure up to 25 MPa (up to 25 MPa) 10 Process fluid temperature 50-200 to+50 С (special order) 320-40 to +320 С 100-40 to +100 С 460-40 to +460 С 250-40 to +250 С 11 Digital display - Without display CI Digital display with basic options 12 Output signals - Pulse output signal 0 1000 Hz and digital output signal RS-485 A Optional analog output signal 4 20 ma 13 Calibration, verification - 5 points factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) * - positions represents the most common options with the best delivery time. The example of the order: EMIS-VIHR 200-Vn-050-A-Zh-Н-FR-2,5-250-A-GP (EMIS-VIHR 200. CK) Integral type (sensor and electronic converter are mounted together)vortex flow converter EMIS-VIHR 200, flameproof enclosure 1ExdIIC(T1-T5), reducer type DN =50 mm, measurement accuracy 0,5%, process fluid - liquids, process-wetted material is stainless steel, maximum process pressure up to 2,5MPa, process fluid temperature from -40 to +250 С, with optional analog output signal, verified, connection kit made of cast steel. http://www.emis-kip.ru/prod/ev200 page 5

catalogue-2014 EMIS-VIHR 200 PPD Vortex flowmeter (for formation pressure maintenance) EMIS-VIHR 200 PPD Applications PPD flowmeters are used to measure the volume flow of water injected into the reservoir during oil production to support pressure of the reservoir, to measure the flow of Cenomanian water and other liquids transmitted under high pressure. EMIS-VIHR PPD observes maximum process pressure requirements, requirements for gas, mechanical and other kinds of fluid pollution. Features & advantages Wide dynamic range Standard mounting dimensions and flow rate allow to replace any other flowmeter used in water injection systems Measures polluted and gaseous liquids Durable and reliable in service Wide range of nominal sizes Regular maintenance is not required permits remote data communication, configuration, testing through RS-485 Modbus RTU «Simulation» diagnostics are available Specifications Process fluids... liquids Mechanical impurity... up to 20g/l Gaseous impurities...up to 15% Process temperature limits... -40 C to 100 C Pressure limits...up to 25MPa Dynamic range...up to 1: 64 Accuracy...±1,0% Output signals...1000hz / 4-20mA /RS485 Explosion proof... 1ExibIIC(T1-T5) Ambient temperature...-50 C to 70 C Water and dust ignition-proof...ip65 Verification interval...4 years Flow ranges Optional specifications DN/ maximum flow Operation range Water flow, m 3 /h Full range Qmin Qmax Qmin Qmax 50/10 0,3 8 0,2 10 50/20 0,7 20 0,5 25 50/35 1 35 0,7 40 50/60 1,5 60 1 65 80/20 0,6 20 0,4 25 80/35 1 35 0,7 40 80/50 1,6 50 1 60 80/150 4 150 2,5 160 100/25 1 25 0,8 32 100/50 2 50 1,25 55 100/200 8 200 6 220 100/300 12 300 10 330 Item EMIS-VIHR 200-PPD.CK EMIS-VIHR 200-PPD.CK-N EMIS-VEKTA VT200 EMIS-VIHR 200.KIP EMIS-BRIZ Description Connection kit (cast steel flanges, stud bolts, screw nuts) Connection kit (stainless steel flanges, stud bolts, screw nuts) Insert pipes for installation use Cable kit for simulation diagnostic use Power supply unit PPD transmitter process pressure value should not be less than: 0,3MPa for Q Qmin ; 0,4MPa for Qmin <Q 0,5 Qmax ; 0,8MPa for Q>0,5 Qmax.!Attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. page 6 http://www.emis-kip.ru/prod/ev200

EMIS-VIHR 200 PPD Ordering information 1 DN / flow range code 50/10 DN=50mm, flow range code 10 50/20 DN=50mm, flow range code 20 50/35 DN=50mm, flow range code 35 50/60 DN=50mm, flow range code 60 80/20 DN=80mm, flow range code 20 80/35 DN=80mm, flow range code 35 80/50 DN=80mm, flow range code 50 80/150 DN=80mm, flow range code 150 100/25 DN=100mm, flow range code 25 100/50 DN=100mm, flow range code 50 100/200 DN=100mm, flow range code 200 100/30 DN=100mm, flow range code 300 2 Accuracy (see table 1.6) - Class B (nominal accuracy ± 1,5% is allowed) A Class A (nominal accuracy ± 1% is allowed) 3 Maximum process pressure - Up to 25MPa (standard) 20 Up to 20MPa 4 Calibration, verification - 5 points factory calibration, pressure test GP Verification The example of the order: EMIS-VIHR 200-PPD-100/50-GP (EMIS-VIHR 200-PPD.CK) Integral type (sensor and electronic transmitter are mounted together) Vortex flowmeter EMIS-VIHR 200-PPD, flameproof enclosure 1ExdIIC(T1-T5), DN=100, flow range code 50, measurement accuracy is 1,5%, maximum process pressure up to 25MPa, process fluid temperature from -40 to +100 С, with pulse, digital and current output signal, verified, connection kit made of cast steel. High pressure vortex fliowmeter EMIS-VIHR 200 PPD on-thespot High pressure vortex flowmeter EMIS-VIHR 200 PPD on the test stand http://www.emis-kip.ru/prod/ev200 page 7

catalogue-2014 EMIS-VIHR 205 insertion VORTE FLOWMETER EMIS-VIHR 205 Applications Suitable for commercial and industrial metering of liquids, gas and steam. Pipeline DN 200 mm to 2000 mm. Certificate of approval for almost all industries. Features & advantages Easy installation No need to stop flow* No moving parts Durable and reliable in service Maintenance works are not required Only flow sensor requires water testing Accuracy is not related to process parameter changes * For process pressure 1,6 MPa. Specifications Process fluids...gas, steam, liquids Process temperature limits...-40 C to 250 C Pressure limits... up to 4,0MPa Pipeline DN... 200mm to 2000mm Dynamic range... 1:27 Accuracy (liquids... ±1,5% Accuracy (gas/steam... ±2,5% Output signals... 1000Hz / 4-20mA /RS485 Explosion proof...1exibiib(t1-t5) / 1ExibIIC(T1-T5)/ 1ExdIIC(T1-T5) Power supply...10v DC to 30V DC Ambient temperature... -40 C to 70 C Water and dust ignition-proof... IP65 Verification interval... 4 years Flow ranges* DN, mm Liquids, m 3 /h Gas/Steam, m 3 /h 200 29 570 320 4410 250 45 880 500 7070 300 66 1270 710 10180 350 90 1730 970 13850 400 120 2260 1260 18100 450 150 2860 1600 22900 500 185 3540 1980 28260 600 265 5090 2850 40700 700 360 6920 3880 55400 800 470 9040 5060 72350 900 595 11450 6400 91560 1000 735 14140 7900 113040 1100 890 17110 9580 136780 1200 1060 20360 11400 162780 1300 1240 23900 13370 191040 1400 1440 27700 15500 221560 1500 1650 31800 17800 254340 1600 1880 36200 20260 289380 1800 2380 45800 25640 366250 2000 2940 56550 31650 452160 DN pipeline nominal diamete. Optional specifications Item BV EMIS-BRIZ Insertion equipment Description Ball valve Power supply unit Equipment for non-stop flow insertion* * For process pressure 1,6MPa. page 8 http://www.emis-kip.ru/prod/ev205

EMIS-VIHR 205 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 Order EMIS-VIHR 205 - Vn - 400 - A - - - Zh - N - - - 1,6-250 - - - - - GP 1 Type of explosion protection Standard* - Without explosion protection (standard) ExB Explosion-proof class 1ExibIIB (T1-T5) ExC Explosion-proof class 1ExibIIC (T1-T5) Vn Explosion-proof enclosure 1ExdIIC(T1-T5) 2 Nominal Diameter 200-2000 DN=200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1800, 2000 mm 3 Accuracy A Class A(nominal accuracy for liquids ± 1,5%, for gas and steam ± 2,5% is allowed) B Class B(nominal accuracy for liquids ± 2,0%, for gas and steam ± 3,0% is allowed) 4 Flow range - Standard 5 Process fluid Zh Liquid G Gas/ saturated steam/ overheated steam 6 Process-Wetted Materials N Stainless steel (standard) 7 Electronic transmitter type - Integral type (sensor and electronic transmitter are mounted together) D Remote type electronic transmitter (cable length 3 m) D Remote type electronic transmitter (with customer-specified cable length, for example, R08) 8 Maximum fluid pressure 1,6 Maximum pressure to 1,6 MPa (standard) 2,5 Maximum pressure 2,5 MPa 4,0 Maximum pressure to 4,0 MPa 9 Process fluid temperature 100-40 to +100 С 250-40 to +250 С 10 Digital display - Without display SI Digital display with basic options 11 Output signals - Pulse output signal 0 1000 Hz and digital output signal RS-485 A Optional analog output signal 4 20 ma 12 Calibration, verification - 5 points factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) * - positions represents the most common options with the best delivery time. The example of the order: EMIS-VIHR 205-Vn-400-A-Zh-N-1.6-250-GP Integral type (sensor and electronic transmitter are mounted together) submersible Vortex flowmeter EMIS-VIHR 205, explosion proof 1ExdIIC(T1-T5), Pipeline DN DN =400 mm, measurement accuracy 1,5%, process fluid - liquids, maximum process pressure up to 1.6MPa, process fluid temperature from -40 to +250 С, verified. http://www.emis-kip.ru/prod/ev205 page 9

catalogue-2014 EMIS-VIHR 200-SKV VORTE BOREHOLE FLOWMETER EMIS-VIHR 200-SKV Applications EMIS-VIHR 200-SKV is up-to-date solution for permanent monitoring of oil and water-injection wells. Flowmeter should be installed on production string. This equipment provides high accuracy of current flow and well discharge. High reliability, thermal and pressure resistance and protection from measuring fluids influences allow to use this flowmeter in the most difficult conditions. Features & advantages unique Well Parameter Control System, no analogues on the market Vortex type Permanent monitoring of well parameters With no moving parts Corrosion-resistant, material stainless steel Durable and reliable in service High thermal and pressure resistance Data transmission to high level of Process Control System (PCS) Specifications Process fluids... oil, layer, wate Process temperature and ambient temperature limits...-20 C to 110 C Pressure limits... up to 50MPa Dynamic range... 1: 17 Accuracy... ±1,5% Output signals...pulse signal/modbus/manchester code-ii Explosion proof... 1ExdIIAT4 Power supply... 12V DC to 30V DC Water and dust ignition-proof... IP68 Verification interval... 4 years Ordering information Flowmeter version Flow range, m 3 /day Q min Q max EMIS-VIHR 200-SKV-020 4,7 190 EMIS-VIHR 200-SKV-036 12,5 500!Attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. Flowmeters can be delivered separately or in oil well systems. For more details, please contact our sales department. EMIS deep-well research complex based on vortex borehole flowmeter EMIS-VIHR 200-SKV see page 29. page 10 http://www.emis-kip.ru/prod/skv

EMIS-META 210 Applications Suitable to measure the low volume flow of liquids and gases. Their main application field is water purging and water treatment, moreover it is used in chemical, oil, food, pulp and paper industries and medicine. EMIS-META 210R has integrated flow regulator that is why it can be used to control the flow. PLASTIC ROTAMETER EMIS-META 210 Features & advantages Directly read flow value Minimum work during installation Doesn t require any settings before installation Flow regulator Durable and reliable in service Stable work VERSIONS Index DN, mm Type* Flow rate, m 3 /h min max Flow rate of liquids ЕМ 210-008А-Zh 8 0,002 0,02 ЕМ 210-008B-Zh 8 0,004 0,04 PА ЕМ 210-008V-Zh 8 0,006 0,06 ЕМ 210-008G-Zh 8 0,01 0,1 ЕМ 210-010А-Zh 10 0,03 0,24 ЕМ 210-010B-Zh 10 PR1 0,06 0,42 ЕМ 210-010V-Zh 10 0,12 1,08 ЕМ 210-010G-Zh 10 0,03 0,24 ЕМ 210-010D-Zh 10 PА 0,06 0,42 ЕМ 210-010Е-Zh 10 0,12 1,08 ЕМ 210-015А-Zh 15 0,016 0,16 ЕМ 210-015B-Zh 15 0,025 0,25 PR2 ЕМ 210-015V-Zh 15 0,04 0,4 ЕМ 210-015G-Zh 15 0,06 0,6 ЕМ 210-025А-Zh 25 0,16 1,6 PR2 ЕМ 210-025B-Zh 25 0,25 2,5 ЕМ 210-025V-Zh 25 0,3 2,1 ЕМ 210-025G-Zh 25 PR1 0,24 3,6 ЕМ 210-025D-Zh 25 0,6 4,2 ЕМ 210-025Е-Zh 25 0,3 2,1 ЕМ 210-025Zh-Zh 25 PА 0,24 3,6 ЕМ 210-025Z-Zh 25 0,6 4,2 ЕМ 210-032А-Zh 32 0,4 4 PR2 ЕМ 210-032B-Zh 32 0,6 6 ЕМ 210-040А-Zh 40 0,9 9 ЕМ 210-040B-Zh 40 1,5 15 PR1 ЕМ 210-040V-Zh 40 1,8 18 ЕМ 210-040G-Zh 40 3 21 ЕМ 210-050А-Zh 50 1 10 PR2 ЕМ 210-050B-Zh 50 1,6 16 ЕМ 210-065А-Zh 65 5 25 ЕМ 210-065B-Zh 65 PR2 8 40 ЕМ 210-065V-Zh 65 12 60 ЕМ 210-100А-Zh 100 16 90 ЕМ 210-100B-Zh 100 PR2 18 120 ЕМ 210-100V-Zh 100 25 200 ЕМ 210-125А-Zh 125 16 90 ЕМ 210-125B-Zh 125 PR2 18 120 ЕМ 210-125V-Zh 125 25 200 ЕМ 210-150А-Zh 150 16 90 ЕМ 210-150B-Zh 150 PR2 18 120 ЕМ 210-150V-Zh 150 25 200 *PR1, PR2 straight through type, PA panel type Index DN, mm Type* Flow rate, m 3 /h min max Adjustable flow rate of liquids ЕМ 210-Р-008А-Zh 8 0,002 0,02 ЕМ 210-Р-008B-Zh 8 0,004 0,04 PА ЕМ 210-Р-008V-Zh 8 0,006 0,06 ЕМ 210-Р-008G-Zh 8 0,01 0,1 ЕМ 210-Р-010А-Zh 10 0,03 0,24 ЕМ 210-Р-010B-Zh 10 PА 0,06 0,42 ЕМ 210-Р-010V-Zh 10 0,24 1,08 ЕМ 210-Р-025А-Zh 25 0,3 2,1 ЕМ 210-Р-025B-Zh 25 PА 0,24 3,6 ЕМ 210-Р-025V-Zh 25 0,6 4,2 Flow rate of gas ЕМ 210-010V-G 10 2,88 28,8 PА ЕМ 210-010G-G 10 4,32 43,2 ЕМ 210-025А-G 25 7 70 PА ЕМ 210-025B-G 25 10 100 Adjustable flow rate of gas ЕМ 210-R-008А-G 8 0,03 0,3 ЕМ 210-R-008B-G 8 0,06 0,6 ЕМ 210-R-008V-G 8 0,12 1,2 PА ЕМ 210-R-008G-G 8 0,24 2,4 ЕМ 210-R-008D-G 8 0,3 3 ЕМ 210-R-008Е-G 8 0,6 6 ЕМ 210-R-010А-G 10 0,72 7,2 ЕМ 210-R-010B-G 10 1,44 14,4 PА ЕМ 210-R-010V-G 10 2,88 28,8 ЕМ 210-R-010G-G 10 4,32 43,2 ЕМ 210-R-025B-G 25 PА 10 100 Specifications Liquid flow rate... 0,002 200 m 3 /h Gas flow rate... 0,03 100 m 3 /h Accuracy...±4% Repeatability... ±0,25% Process pressure limits... 100Pa to 1MPa Viscosity... 5mPa*s Process temperature... -20 to 80 C Connection thread material... plastic ABS, PVC Measuring mechanism material... stainless steel Rotameter material...pmma Ambient temperature... -40 to 70 C http://www.emis-kip.ru/prod/em210 page 11

catalogue-2014 EMIS-META 215 METAL ROTAMETER EMIS-META 215 Application The main difference between metal rotameter and plastic or glass is that metal one can be used for high pressure and high temperature applications. EMIS-META 215 rotameter measurement accuracy is high, it is easy to install, provides flow conversion to standard current signal 4 20 ma or to HART digital signal. It is not only measures volume flow, but also can totalize and display accumulated flow value. Flow ranges Flow rangers Water, l/h DN, mm Stainless steel Teflon (Ft) (N) Gas, m 3 /h 015А 2,5 25 0,07 0,7 015B 4 40 2,5 25 0,11 1,1 015V 6,3 63 4 40 0,18 1,8 015G 10 100 6,3 63 0,28 2,8 015D 16 160 10 100 0,48 4,8 015E 25 250 16 160 0,7 7,0 015Zh 40 400 25 250 1,0 10 015I 63 630 40 400 1,6 16 025А 100 1000 63 630 3 30 025B 160 1600 100 1000 4,5 45 025V 250 2500 160 1600 7 70 025G 400 4000 250 2500 11 110 040А 500 5000 400 4000 12 120 040B 600 6000 500 5000 16 160 050А 630 6300 600 6000 18 180 050B 1000 10 000 630 6300 25 250 050V 1600 16 000 1000 10 000 40 400 080А 2500 25 000 1600 16 000 60 600 080B 4000 40 000 2500 25 000 80 800 100 6300 63 000 4000 40 000 100 1000 150 20 000 100 000 600 3000 Optional specifications Item EMIS-META 215. CK http://www.emis-kip.ru/prod/em215 Magnetic filter HART modem EMIS-BRIZ EMIS-VEKTA VT.215 Features & advantages Simple design High accuracy Durable and reliable in service Measures aggressive(corrosive) fluids Integrated digital display Stable under high pressure and temperature conditions Integrated alarm system Easy to check and calibrate Specifications Flow rate of liquids...2,5 100000 l/h Flow rate of gas... 0,07 3000 m 3 /h Nominal diameter...15 to 150 mm Output signals and indication... LCD display / analog current signal 4-20mA / HART / one or two limit switches Accuracy...1,5%, 2,5% Process pressure... up to 10 MPa Process temperature... -80 C to 250 C Ambient temperature... -25 C to 55 C Water and dust ignition-proof... IP65 Explosion proof... 1ExibIIBT2/T4, 1ExdibIIBT2/T4 Power supply...24v DC Connection type...flange / coupling /fixture Verification interval... 5 years Delivery kit Item Amount, pcs 1 Metal rotameter 1 2 Certificate 1 3 User manual 1!Attention! Description Connection kit (flange, gaskets, metalware) Cleans mechanical contamination from fluid Provides data communication through HART protocol Power supply unit Insert pipes for installation use To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. page 12 http://www.emis-kip.ru/prod/em215

EMIS-META 215 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Order EMIS-META 215 - - - 050 - B - Zh - N - - - 1,6-100 - 1,5 - T - A - - GP 1 Type of explosion protection - Without explosion protection Ex 1ExibIIBT2/T4 intrinsically-safe circuit Vn 1ExdIIC(T1-T5) explosion-proof enclosure and intrinsically-safe circuit 2 Nominal Diameter 015 DN=15mm 080 DN=80mm 025 DN=25mm 100 DN=100mm 040 DN=40mm 150 DN=150mm 050 DN=50mm 3 Flow range* A Flow range A E Flow range E B Flow range B Zh Flow range Zh V Flow range V I Flow range I G Flow range G D Flow range D * According to the special order we can produce rotameters with individual flow ranges. In this case, please tell us your requirements for flow range and put after diameter code (see the example of the order). 4 Process fluid* Zh Liquid G Gas * Generally our rotameters are calibrated to be used under normal conditions (hereinafter referred as to NC). Normal conditions are: Liquid water at 20 C; Gas air at 20 C and 0,1013MPa If you need to change the process fluid that is different to NC, please indicate it in your order. 5 Process-Wetted Materials N Stainless steel (SS304) Ft Teflon (PTFE) 6 Pipeline connections* - Flange M Coupling, screw thread SMS1146 Z Fixture * M and Z type is not available in Teflon (Ft process-wetted material) 7 Process pressure 1,6 Maximum pressure 1,6 MPa 2,5 Maximum pressure 2,5 MPa 4,0 Maximum pressure 4,0 MPa 10 Maximum pressure 10,0 MPa 8 Process fluid temperature 100-40 C to 100 С 250* -80 C to 250 С * Is not available in Teflon (Ft process-wetted material) and with M and Z pipeline connections. 9 Accuracy 2,5 Accuracy class 2,5 1,5 Accuracy class 1,5 10 Thermal jacket - Without thermal jacket T Thermal jacket for heating rotameter body by steam or oil 11 Output interface - Without interface A Analog output interface 4 20 ma H* HART +analog output interface 4 20 ma PV1 One limit switch PV2 Two limit switchers 12 Optional LCD-display - Without display Zh* LCD-display * LCD-display is available only for rotameters with output signal type A and H. H-type output signal rotameters are always equipped with LCD-display. 13 Calibration, verification - Factory calibration, pressure test (for technological needs) GP Verification The example of the order: EMIS-META 215-050-400-B-Zh-N-1,6-100-1,5-T-A (EMIS-META 215.CK) Rotameter EMIS-META 215 with intrinsically-safe circuit, Pipeline DN DN =50 mm, process fluid - liquids, maximum process pressure up to 1.6MPa, process-wetted material stainless steel, process fluid temperature from -40 to +100 С, with heating module, accuracy 1,5%, analog output signal, without LCD-display, with connection kit, verified. http://www.emis-kip.ru/prod/em215 page 13

catalogue-2014 EMIS-PLAST 220 ELECTRONIC FLOWMETER FOR LIQUIDS EMIS-PLAST 220 Applications For high pressure line applications to measure the volume and volume flow of liquids, for process data communications and accountings. Electronic flowmeters EMIS-PLAST 220 are used in numerous branches of industry such as petroleum, chemical, petrochemical, metal industry and in public facilities. Flow range DN, mm Flow range, m 3 /h, depending on accuracy 0,5% 1% 1,5% 2,5% 008 0,1 0,5 0,15 0,7 0,1 0,8 0,08 0,8 015 0,15 0,75 0,2 1 0,15 1,5 0,12 1,5 020 0,3 0,5 0,3 1,5 0,3 3 0,2 4 025 1 5 1 5 0,6 6 0,5 7 040 3 15 3 15 2 15 1,5 15 050 4 20 4 20 2,5 25 2 25 065 6 50 5 50 4 50 080 10 80 10 100 6 100 100 30 200 20 200 18 250 150 50 300 40 400 30 400 200 100 500 60 600 70 700 250 200 1000 150 1500 120 1500 300 300 1500 250 2000 150 2000 Specifications Nominal diameter...8mm to 300mm Vibration limits... frequency 10-55Hz / maximum acceleration amplitude: 19,6m/s 2 Output signals... pulse / 4-20 ma / Modbus RTU Maximum process pressure... up to 42 MPa Process temperature limits... 0 C to 150 C Ambient temperature... -40 C to 50 C Explosion proof...1exdiibt4 / PB Exdl Water and dust ignition-proof... IP65 Power supply...24v DC or 3,6V integral battary Verification interval... 4 years Viscosity... up to 5 cp Connection type... flange Features & advantages Flow measurement under high pressure Non-clog design Suitable for corrosive fluids Stable work under high pressure Explosion proof 1ExdllBT4 and PB Exdl are available!attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. Versions Code Process-wetted part Primary transducer Applications Standard Straight Polluted liquids, water with oil and mechanical pieces Teflon-coated impeller U Angular est. Materials Generally we recommend to choice meter body and flanges made of cast steel. For corrosive fluid applications or in case of special requirements for hygiene, you should choice meter body and flanges made of stainless steel (N version). Optional specifications Item EMIS-PLAST 220.CK EMIS-VEKTA VT220 EMIS-BRIZ Description Connection kit (flange, gaskets, bolts, screw nuts, washers) Insert pipes for installation use Power supply unit page 14 http://www.emis-kip.ru/prod/ep220

EMIS-PLAST 220 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 Order EMIS-PLAST 220 - Vn - - - 050 - - - N - 6,3-80 - - - 1 - - - FR - GP 1 Type of explosion protection - Without explosion protection Vn Explosion-proof class 1ExdllBT4 PB Explosion-proof class PB Exdl 2 Version - Standard version U Angular version 3 Nominal Diameter 008 Dn = 8 мм 080 Dn = 80 мм 015 Dn = 15 мм 100 Dn = 100 мм 020 Dn = 20 мм 150 Dn = 150 мм 025 Dn = 25 мм 200 Dn = 200 мм 040 Dn = 40 мм 250 Dn = 250 мм 050 Dn = 50 мм 300 Dn = 300 мм 065 Dn = 65 мм Х 4 Flow range - Standard, according to UM Specail order 5 Process-Wetted Materials ST Cast steel N Stainless steel (standard) 6 Process fluid pressure 1,6 Maximum pressure 1,6 MPa 16,0 Maximum pressure 16,0 MPa 2,5 Maximum pressure 2,5 MPa 25,0 Maximum pressure 25,0 MPa 4,0 Maximum pressure 4,0 MPa 42,0 Maximum pressure 42,0 MPa 6,3 Maximum pressure 6,3MPa 7 Process fluid temperature 80 0 to 80 С 150 0 to 150 С 8 Output signals - Pulse output signal and digital output signal Modbus RTU A Optional current output signal (4 20 ma) 9 Accuracy 0,5 0,5% 1 1% 1,5 1,5% 2 2% 10 Digital display - Digital display with basic options 11 Pipeline connection - Flange FR Flanged reducer type 12 Calibration, verification - Factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) The example of the order: EMIS-PLAST 220-Vn-050-N-6,3-80-1-FR-GP (EMIS-PLAST 220.CK) Electronic flowmeter for liquids EMIS-PLAST 220 STANDART with explosion proof 1ExdllBT4, flanged reducer type DN=50mm, process-wetted material stainless steel, maximum process pressure up to 6,3MPa, measurement accuracy 1%, process temperature range 0 C to 80 C, pulse and digital output signals, with connection kit. http://www.emis-kip.ru/prod/ep220 page 15

catalogue-2014 EMIS-PLAST 220R ELECTRONIC FLOWMETER FOR LIQUIDS WITH INTEGRATED FLOW CONTROLLER EMIS-PLAST 220R Applications This is unique solution that includes flowmeter for liquids, valve and controller. Suitable for automatic measurement and control system and dosing system applications. Widely used in reservoir pressure maintenance systems and in oil wells for water and oil water interface measurement. Mechanical pollution protection and oil protection allow to use this flowmeter for waste water applications. Features & advantages Self-contained power supply Self-contained and manual flow control valve Space effective Wireless digital interface Cost-effective flow control system Doesn t require extra setting Principle of operation Customer through push-button operation or remote through the interface set the flow rate. During operation process controller regulate valve position to maintenance the flow level. Manual control is also available, that allows to use flowmeter in dosing systems effectively and provides flow control in case of power failure situations. Flow ranges DN, mm Full range, m 3 /h, depending on accuracy 1% 1,5% 2,5% 015 0,2 1 0,15 1,5 0,12 1,5 020 0,3 1,5 0,3 3 0,2 4 025 1 5 0,6 6 0,5 7 040 3 15 2 15 1,5 15 050 4 20 2,5 25 2 25 DN pipeline nominal diameter of pipeline, mm. If pipeline DN and meter DN are not match together, conical adapters can be used. Centre angle of adapter can t be more than 30. Optional specifications Specifications DN... 15 mm to 80 mm Accuracy...up to 1% Flow level stability...1% Output signals...pulse / 4-20mA /Modbus RTU Maximum process pressure... up to 16 MPa Process temperature... -20 C to 150 C Ambient temperature... -40 to 55 C Explosion proof...1exdiibt4 Water and dust ignition-proof... IP65 Power supply...3,6 V integral battery / 24 V DC / 220 V AC Connection type...flanged Verification interval... 4 years Viscosity... up to 5 sp!attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. Item EMIS-PLAST 220.CK EMIS-VEKTA VT220R EMIS-VIHR 200.KIP EMIS-SYSTEMA 750 EMIS-BRIZ Description Connection kit (flange, gaskets, bolts, screw nuts, washers) Insert pipes for installation use Cable kit for simulation diagnostic use RS-485 converter Power supply unit page 16 http://www.emis-kip.ru/prod/ep220

EMIS-PLAST 220R Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 Order EMIS-PLAST 220 - - - R - 050 - - - N - 6,3-80 - - - 1 - - - FR - GP 1 Type of explosion protection - Without explosion protection Vn Explosion-proof class 1ExdllBT4 2 Version - Standard version U Angular version 3 Nominal Diameter 015 Dn = 15 mm 020 Dn = 20 mm 025 Dn = 25 mm 040 Dn = 40 mm 050 Dn = 50 mm Х 4 Flow range - Standard, according to 1.3.2 specail order 5 Process-Wetted Materials ST Cast steel N Stainless steel 6 Process fluid pressure 1,6 Maximum pressure 1,6 MPa 6,3 Maximum pressure 6,3MPa 2,5 Maximum pressure 2,5 MPa 16 Maximum pressure 16,0 MPa 4 Maximum pressure 4,0 MPa Maximum pressure 42,0 MPa 7 Process fluid temperature 80-20 C to 80 С 150* 0 to 150 С * Previously contact us 8 Output signals - Pulse output signal and digital output signal Modbus RTU A Optional current output signal (4 20 ma) and digital output signal Modbus RTU 9 Accuracy 1 1% 1,5 1,5% 2 2% 10 Digital display - Digital display with basic options 11 Pipeline connection - Flange FR Flanged reducer type 12 Calibration, verification - 5 points factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) The example of the order: EMIS-PLAST 220r-Vn-R-050-N-6,3-80-A-1-FR-GP (EMIS-PLAST 220.CK) Electronic flowmeter for liquids EMIS-PLAST 220R with controller, flanged reducer type DN=50mm, process-wetted material stainless steel, maximum process pressure up to 6,3MPa,process temperature range -20 C to 80 C, measurement accuracy 1%, pulse and digital output signals, with connection kit. http://www.emis-kip.ru/prod/ep220 page 17

catalogue-2014 EMIS-DIO 230 HIGH ACCURACY ROTOR FLOWMETER FOR LIIQUIDS EMIS-DIO 230 Applications Suitablefor commercial and industrial metering of liquids with high accuracy up to 0,15%.For liquefied gas, light oil products, oil, oil water, black oil and other viscous fluids measurement applications. Used in fuel and energy industry and others. Features & advantages High accuracy No straight pipe length requirements High reliability, noiseless operation Power supply built-in lithium battery Digital display Specifications Process fluids... liquefied gas, liquids Viscosity... up to 20000mPa s Process temperature limits... -20 C to 250 C Process pressure limits... up to 6,4 MPa Pipeline DN... 8 mm to 400 mm Accuracy... 0,15 / 0,25 / 0,5% Output signals...pulse / 4-20mA /Modbus RTU Explosion proof... 1ExdIIC(T2-T6) Power supply... 3,6V / 24V Ambient temperature... -40 C to 70 C Water and dust ignition-proof... IP65 Verification interval... 1 years Connection type...flanged Specified uncertainty flow range DN, mm Full flow range, m 3 /h 0,32-0,8mPa s Petrol, liquefied gas 0,8-2 mpa s Kerosene, water 2 5 mpa s, 5 400 mpa s Diesel oil, crude oil 400 2000 mpa s bitumen 2000 20 000 mpa s Ultraviscous liquids 0,5 0,25 0,5 0,25 0,5 0,25 0,5 0,25 0,5 0,25 008 0,009 0,35 0,06 0,3 0,10 0,3 0,05 0,3 0,07 0,3 0,03 0,3 0,06 0,3 0,03 0,27 0,06 0,27 0,03 0,24 0,06 0,24 015А 0,025 0,9 0,2 0,8 0,27 0,8 0,1 0,8 0,2 0,8 0,08 0,8 0,16 0,8 0,08 0,7 0,16 0,7 0,08 0,6 0,15 0,6 015Б 0,03 1,1 0,25 1 0,33 1 0,2 1 0,25 1 0,1 1 0,2 1 0,1 0,9 0,2 0,9 0,1 0,8 0,2 0,8 015В 0,15 4,5 0,6 3 0,4 4 0,4 4 0,3 2,4 0,3 2,4 025А 0,2 6,5 1,5 6 1,2 6 1,2 6 1,5 6 0,6 6 1,2 6 0,5 5,4 1,2 5,4 0,6 5 1,2 5 025Б 0,3 11 3 8 1,5 10 1 10 1 8 1 6 040 0,8 28 8 20 8 20 2,7 22 5,5 22 2,5 25 4,4 22 2,1 18 4,2 18 1,5 12 3 12 050 1,2 44 9 36 15 36 4,5 36 9 36 4 40 7,2 36 2,8 24 6 24 2,2 18 4,5 18 080 3 100 20 80 32 80 10 80 20 80 9 90 16 80 6,5 56 14 56 5 40 10 40 100 4 110 25 100 40 100 13 100 25 100 12 100 20 100 8,5 72 18 72 6,5 54 14 54 150 8 280 55 225 88 220 31 250 57 225 25 250 44 220 18 150 38 150 12 100 25 100 200 15 440 90 360 150 360 50 400 90 360 40 400 72 360 28 240 53 210 20 160 40 160 250 20 650 135 540 180 540 68 540 135 540 60 600 108 540 42 360 90 360 30 240 60 240 300 30 1100 220 900 300 900 112 900 225 900 100 1000 180 900 70 600 150 600 54 450 113 450 400 90 1700 400 1600 550 1600 200 1600 400 1600 180 1800 320 1600 130 1100 275 1100 90 750 180 750 Those are actual flow ranges for meters made of cast steel and for process temperature up to 150 C; flow ranges for meters made of stainless steel (H1,H2) or for high temperature applications can be found in user manual.!attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. page 18 http://www.emis-kip.ru/prod/ed230

EMIS-DIO 230 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Order EMIS-DIO 230 - Vn - 050 - - - SG - St - F - T - - - 1,6-80 - 0,5 - SI - А - GP 1 Type of explosion protection - Without explosion protection Vn Explosion-proof class 1ExdllC(T2-T6) 2 Nominal Diameter 008 DN = 8 мм 150 DN = 150 мм 015 DN = 15 мм 200 DN = 200 мм 025 DN = 25 мм 250 DN = 250 мм 040 DN = 40 мм 300 DN = 300 мм 050 DN = 50 мм 400 DN = 400 мм 080 DN = 80 мм 100 DN = 100 мм 3 Flow range - Standard, according to UM A B Standard, according to UM * Specail order *According to the special order we can produce meters with individual flow ranges. In this case, please tell us your requirements for flow range and put after diameter code (see the example of the order). 4 Process fluid - Liquids with viscosity 0,8mPa to 20000mPa*s (kerosene, water, diesel oil, crude oil, bitumen, ultraviscous liquids) SG Liquids with viscosity up to 0,8mPa (liquefied gas, petrol) 5 Process-Wetted Materials ST Meter body and rotor made of cast steel N1 Rotor made of stainless steel, meter body made of cast steel N2 Meter body and rotor made of stainless steel 6 Pipeline connection F Flange FR* Flanged reducer type *Previously contact us 7 Thermal jacket - Without thermal jacket T* Thermal jacket for external heating meter body by steam or oil *EMIS-DIO 230 DN=8 mm is not available with thermal jacket. 8 Electronic transmitter type - Electronic transmitter are mounted on primary transducer body D* Remote type electronic transmitter *Maximum cable length 100 m for meters with accuracy 0,15% or for DN40 and more; for other versions maximum cable length is up to 5m. 9 Process fluid pressure 1,6 Maximum pressure 1,6 MPa 2,5 Maximum pressure 2,5 MPa 4 Maximum pressure 4,0 MPa 6,4 Maximum pressure 6,4 MPa 10 Process fluid temperature 80 Process fluid temperature -20 C to 80 C 150 Process fluid temperature 80 C to 150 C 250 Process fluid temperature 150 to 250 C 11 Accuracy 0,5 0,5% 0,25 0,25% 0,15 0,15% (please contact our specialists for confirmation) 12 Indication - Without indication SI Volume flow digital display 13 Output signal - Pulse + digital signal RS-485 A Optional analog current signal 4-20mA 14 Calibration, verification - Without calibration GP Verification (for fiscal metering) The example of the order: EMIS-DIO 230-Vn-050-SG-St-F-T-1,6-80-0,5-SI-A-GP Rotor flowmeter for liquids EMIS-DIO 230 with explosion proof 1ExdllCT6, DN=50mm, process fluid viscosity up to 0,8mPa s, process-wetted material is cast steel, with thermal jacket, maximum process pressure up to 1,6MPa, process temperature limits -40 C to 80 C, with analog current and digital output signals, with filter and connection kit. http://www.emis-kip.ru/prod/ed230 page 19

catalogue-2014 EMIS-DIO 230L OVAL GEAR METER EMIS-DIO 230L APPLICATIONS EMIS-DIO 230L is used for volume flow measurement of liquids with viscosity up to 2000mPa*s. is simplified version of rotor meter EMIS- DIO 230. The construction of measuring mechanism is easier. This kind of meters is used in petrochemical industry for commercial and process measurement. It is also used in other industries in case it s suitable for operating conditions. Process liquids include petrol, liquefied gas, kerosene, diesel oil, oil, oil water, fuel oil and other liquids used in fuel and energy industries. FEATURES AND BENEFITS Wide range of measurement. Measurement can be performed for wide viscosity range (up to 2000mPa*s) Compact and robust Simple and durable construction of measuring mechanism Cost-effective compared with rotor meters Mechanical version of meter is available, doesn t require power supply Easy installation and service SPECIFICATIONS Nominal diameter... 10 to 200mm Process viscosity... up to 2000 mpa*s Flow range... 0,03 to 340 m 3 /h Process fluid...liquids Process fluid temperature... -40 C to 200 C Process pressure... up to 6,3 MPa Dynamic range...up to 1:10 Accuracy...0,5 Output signal*... analog 4-20 ma / pulse Explosion proof*...1exdllbt4 Power supply*... 24 VDC Ambient temperature...-40 C to 60 C Water and dust ignition proof...ip65 Verification interval... 1 year *For version with output signal Диапазон расхода DN Flow ranges with normalized accuracy 0,5%, m 3 /h 200-1000 <0,3 mpa*s 0,3-0,8 mpa*s 0,8-2 mpa*s 2-200 mpa*s mpa*s 1000-2000 mpa*s 10 0,2 0,5 0,08 0,5 0,05 0,5 0,03 0,3 0,03 0,2 15 0,75 1 0,3 1,5 0,15 1,5 0,1 1,05 0,07 0,75 20 1,5 3 0,4 3 0,3 3 0,2 2,1 0,15 1,5 25 4 6 3 6 0,8 6 0,6 6 0,4 4,2 0,3 3 40 9 15 7,5 15 2 15 1,5 15 1,0 10,5 0,7 7,5 50 10 24 8 24 3 24 2,4 24 1,6 16,8 1,2 12 80 40 60 30 60 8 60 6 60 4,2 42 3 30 100 67 100 50 100 13 100 10 100 6 70 5 50 150 127 340 170 340 43 340 34 340 13,3 133 9,5 95 200 227 340 170 340 43 340 34 340 23,8 238 17 170 OPTIONAL SPECIFICATIONS Item Description EMIS-DIO 230L-CK EMIS-VEKTA VT230L EMIS-VEKTA EMIS-BRIZ Connection kit (flanges, gaskets, screw-bolts, nuts, washers) Insert pipes for installation use Filter and / or gas separator All-purpose power supply unit (for version with output signal) page 20 http://www.emis-kip.ru/prod/ed230l

EMIS-DIO 230L ORDERING INFORMATION 1 2 3 4 5 6 7 8 9 10 11 EMIS-DIO 230 - - - L - 50 - - - - - - - - - - - - - - - GP The example of the order: EMIS-DIO 230-L-50-GP 1 Type of explosion protection - Without explosion protection Vn* Explosion-proof class 1ExdllBT4 * For version with output signal 2 Version L Oval gears version 3 Nominal Diameter 010 DN =10 mm 015 DN = 15 mm 020 DN = 20 mm 025 DN = 25 mm 040 DN = 40 mm 050 DN = 50 mm 080 DN = 80 mm 100 DN = 100 mm 150 DN = 150 mm 200 DN = 200 mm 4 Process fluid - Liquids with viscosity from 0 to 200 mpa*s SV* Liquids with viscosity from 200 to 2000 mpa*s * Please contact our specialists first 5 Location of indicator - Integral type ( primary transducer and indicator are mounted on meter body) 6 Process pressure - Process pressure 1,6 MPa 2,5 Process pressure 2,5 MPa 4,0 Process pressure 4,0 MPa 6,3 Process pressure 6,3 MPa 7 Process-Wetted Materials - Gears and meter body made of cast iron St Gears made of cast iron, meter body made of cast steel A1 Gears made of cast iron, meter body made of aluminum A2 Gears made of aluminum, meter body made of cast iron 8 Process fluid temperature - Standard version, according to UM (see table 1.8) 80 High temperature version, according to UM(see table 1.8) Vn High temperature version, according to UM (see table 1.8) 9 Accuracy 0,5 Accuracy class 0,5 10 Output signal and indication - Without output signal, mechanical indicator with scale A* Analog current signal 4-20mA I* Pulse * *Please contact our specialists first 11 Calibration, verification - Factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) http://www.emis-kip.ru/prod/ed230l page 21

catalogue-2014 EMIS-MASS 260 MASS FLOWMETER EMIS-MASS 260 APPLICATION Used for volume and mass flow measurement, for density, mass and flow measurement of liquids. The information is used for process data communications and accountings in chemical, petrochemical, oil, food, pharmaceutical, other industries and public facilities applications. FEATURES & ADVANTAGES No obstructions inside of the process-wetted part Direct volume flow measurement with high accuracy Measures density and temperature of the fluid Modern digital signal processor No straight pipe length requirements Automatic temperature data correction Pressure data correction No moving parts, high reliability Can be installed and monitored thought RS-485 using EMIS-Integrator software Can be used with MicroMotion ProLink software Full Russian display menu, all parameters are available to install through the display DELIVERY KIT Item Amount, pcs 1 Flowmeter 1 2 Certificate 1 3 Verification certificate (if ordered verified meter) 1 4 User manual 1 5 Calibration instructions 1 SPECIFICATIONS Nominal diameter... 15 to 200mm Uncertainty of flow measurement... 0,15%, 0,25%, 0,5% Uncertainty of temperature measurement...±1 C Uncertainty of density measurement... ±0,001g/cm 3 Dynamic range...up to 1:100 Output signal... pulse / 4-20 ma / RS-485 Process pressure... up to 6,4 MPa Process fluid temperature... -50 C to 300 C Ambient temperature... -40 C to 55 C Explosion proof...1exd[ib]llct6 for electronic module / 1ExibllC(T1-T4) for sensor Water and dust ignition proof...ip65 Power supply...±24 V DC / ~220 V AC Verification interval... 4 year FLOW RANGE DN, mm Flow range t/h depending on accuracy class* Zero point stability, Full range 0,15% 0,25% / 0,5% kg/h 15 0,03 3 (0,02 2) 0,15 3 (0,2 2) 0,10 3 (0,15 2) 0,2 25 0,08 8 (0,06 6) 0,4 8 (0,6 6) 0,3 8 (0,4 6) 0,6 40 0,32 32 (0,36 36) 2 32 (3,6 36) 1,5 32 (2,4 36) 3 50 0,5 50 (0,5 50) 3,5 50 (5 50) 2,5 50 (3,5 50) 5 80 1,4 140 6 140 6 140 12 100 2 200 15 200 10 200 20 150 5 500 35 500 25 500 50 200 10 1000 70 1000 50 1000 100 We are also developing flowmeters with DN 250 and 300 mm, for process pressure up to 25MPa, automatic process pressure correction version and compact version. Please, ask our specialists first. *Flow ranges of compact version are specified in brackets. OPTIONAL SPECIFICATIONS Item EMIS-MASS 260-CK EMIS-VEKTA VT260 EMIS-BRIZ Description Connection kit (flanges, gaskets, stud bolts, screw- nuts, washers) Insert pipes for installation use Power supply unit page 22 http://www.emis-kip.ru/prod/em260

EMIS-MASS 260 ORDERING INFORMATION Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Order EMIS-MASS 260 - Ex - 050 - - - I - Zh - - - 1,6-100 - 220 - А - 0,15 - - - - - GP 1 Type of explosion protection - Without explosion protection (standard version) Ex 1ExibllC(T1-T4) for sensor, Exd[ib]llCT6 for electronic transmitter 2 Nominal Diameter 015 15 mm 100 100 mm 025 25 mm 150 150 mm 040 40 mm 200 200 mm 050 50 mm 080 80 mm 3 Meter body version - Standard, U-tube version C Compact version 4 Electronic transmitter type I Integral type - sensor and electronic transmitter are mounted as one structural element D Remote type electronic transmitter with cable length of 3m D Remote type electronic transmitter with cable length of m (maximum length 300m) 5 Process fluid Zh Liquid 6 Process-Wetted Materials - Stainless steel (standard version) 7 Process fluid pressure 1,6 Maximum process pressure 1,6 MPa 2,5 Maximum process pressure 2,5 MPa 4,0 Maximum process pressure 4,0 MPa 6,4 Maximum process pressure 6,4 MPa (for DN10 DN50) 8 Process fluid temperature 100-50 C to 100 C 200-50 C to 200, only for remote type transducer version 300-50 C to 300, only for remote type transducer version 9 Power supply 24 24 VDC 220 220 VAC 10 Output signal - Pulse output signal + digital signal RS-485 (standard version) A Optional current output signal 4-20mA 11 Accuracy 0,15 Accuracy class 0,15 0,25 Accuracy class 0,25 0,5 Accuracy class 0,5 12 Digital display - Digital display with basic options 13 Pipeline connection - Flange (standard version) 14 Calibration, verification - 5 points factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) THE EAMPLE OF THE ORDER: EMIS-MASS 260-Ex-050-I-Zh-1,6-100-220-A-0,15-GP(EMIS-MASS 260.CK) Mass flowmeter EMIS-MASS 260 with explosion proof, DN 50mm, integral type, process-wetted material stainless steel, maximum process fluid pressure up to 1,6 MPa, process fluid temperature limits -50 C to 100 C, with analog current, pulse and digital output signals, accuracy class equaled to 0,15% measurement uncertainty, verified, with connection kit. http://www.emis-kip.ru/prod/em260 page 23

catalogue-2014 EMIS-MAG 270 MAGNETIC FLOWMETER EMIS-MAG 270 APPLICATION EMIS-MAG 270 flowmeters are used for volume flow measurement of conductive liquids with flow velocity from 0,1 to 10 m/s, including corrosive, two-phase and polluted liquids (slurries and fluids with particles) with minimal conductivity 5 10-4 cm/m. EM-270flowmeters can be used in automatic process control systems for technological and fiscal metering in power, chemical, paper and other industries. It can be mounted on metal or plastic pipes. EMIS-MAG 270 is also provides reverse flow detection and it is available in two versions for general purposes and for explosion hazardous applications. Flow range DN, mm Qmin, Q1, Q2, Qmax, m 3 /h m 3 /h m 3 /h m 3 /h 15 0,06 0,19 0,64 6,40 20 0,11 0,34 1,13 11,30 25 0,18 0,53 1,77 17,70 32 0,30 0,87 2,89 28,90 40 0,45 1,34 4,50 45,00 50 0,71 2,13 7,10 71,00 65 1,20 3,57 11,90 119 80 1,80 5,43 18,10 181 100 2,80 8,49 28,30 283 125 4,40 13,30 44,20 442 150 6,40 19,10 63,60 636 200 11,30 33,90 113 1130 250 17,70 53,10 177 1770 300 25,50 76,20 254 2540 350 34,60 104 346 3460 400 45,00 136 452 4520 450 57,00 172 572 5720 500 70,50 212 707 7070 600 100 306 1020 10 200 700 140 416 1385 13 850 800 180 543 1810 18 100 900 230 687 2290 22 900 1000 280 849 2830 28 300 1200 407 1221 4070 40 700 1400 554 1662 5540 55 400 1600 724 2172 7240 72 400 1800 916 2748 9160 91 600 2000 1130 3393 11 310 113 100 2200 1368 4100 13 680 136 800 Pulse, frequency and digital signal intrinsic error limit is: ±0,5% for Qmax Q>Q2; ±1,0% for Q2 Q>Q1; ±5% for Q1 Q>Qmin. Features & advantages Wide range of lining materials and electrodes allow to use EMIS- MAG 270 for corrosive fluid applications Process pressure up to 32 MPa EMIS-MAG 270 flowmetersare able to measure two-phase liquids and polluted liquids (slurries and liquids with small pieces) because of magnetic measurement principle Accuracy of the flow measurement is not related with fluid viscosity and density Wide range of Pipeline DN with maximum DN 3000mm allows to use this flowmeter for high-flow applications Cost-effective (built-in indicator allows to use EMIS-MAG 270 without optional indicating devices) Variable installation (can be mounted on horizontal or vertical pipeline sections) Verification interval at the market leaders level No moving parts and parts inserted into pipe Low pressure loss SPECIFICATIONS Nominal Diameter... 15 to 3000mm Uncertainty... ±0,5 Dynamic range... 1:100 Process pressure... up to 32 MPa Process fluid temperature... -40 C to 180 C Ambient temperature... -40 C to 75 C Output signal...analog current signal 4-20 ma / frequency or pulse signal / ModBus /HART Explosion proof...1exd[ib]llct6 for electronic module / 1ExibllC(T1-T4) for sensor Water and dust ignition proof... IP65 Power supply...±24 V DC / ~220 V AC Verification interval...4 year Optional specifications Item EMIS-MAG 270-CK EMIS-MAG 270 VT EMIS-MAG 270 ZK EMIS-BRIZ EMIS -SYSTEMA 750 HART Modem Description Connection kit (flanges, gaskets, screw- bolts, screw- nuts, washers) Insert pipes Ground ring Power supply unit RS-485 converter HART protocol data communication device page 24 http://www.emis-kip.ru/prod/em270

EMIS-MAG 270 Ordering information Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Order EMIS-MAG 270 Ex - 080 - - - - - PP - TI - - - - - 6,4 - - - - - - - 24 - М - GP 1 Type of explosion protection - Without explosion protection Ex 1ExiallC(T3-T4) for sensor, Exd[ib]llCT6 (intrinsically-safe circuit)for primary transducer 1Exd[ia]llCT4 (intrinsically-safe circuit, explosion-proof enclosure) for electronic transmitter 2 Nominal Diameter 015 Dn = 15 600 Dn = 600 020 Dn = 20 700 Dn = 700 025 Dn = 25 800 Dn = 800 032 Dn = 32 900 Dn = 900 040 Dn = 40 1000 Dn = 1000 050 Dn = 50 1200 Dn = 1200 065 Dn = 65 1400 Dn = 1400 080 Dn = 80 1600 Dn = 1600 100 Dn = 100 1800 Dn = 1800 125 Dn = 125 2000 Dn = 2000 150 Dn = 150 2200 Дy = 2200 200 Dn = 200 2400* Dn = 2400 250 Dn = 250 2600* Dn = 2600 300 Dn = 300 2800* Dn = 2800 350 Dn = 350 3000* Dn = 3000 400 Dn = 400 Х 450 Dn = 450 * Please contact our specialists for confirmation first. 500 Dn = 500 3 Flow range - Standard, according to the Table 1 4 Transducer materials - Cast steel N1* Stainless steel(ss304) N2* Stainless steel (SS316L) * Please contact our specialists for confirmation first. 5 Lining materials PTF Polytetrafluoroethylene (PTFE-4) CR Chloroprene rubber (technical rubber) FEP Fluorinated ethylene propylene PP Polypropylene PFA* Perfluoroalkoxy PK* Polyurethane rubber (technical rubber) * Please contact our specialists for confirmation first. 6 Electrode Materials - Stainless steel (SS316L) HC Hastelloy C HB* Hastelloy B V Tungsten carbide TI Titanium TA Tantalum PT* Platinum-iridium composition * Please contact our specialists for confirmation first. http://www.emis-kip.ru/prod/em270 page 25

catalogue-2014 EMIS-MAG 270 7 Pipeline connection - Flange 8 Electronic transmitter type - Integral type - ( primary transducer and transmitter are mounted as one structural element) D* Remote type electronic transmitter with cable length of 3 m D* Remote type electronic transmitter with cable length of m (maximum length 300 m) *Explosion proof only for primary transducer. 9 Process pressure 0,6 0,6 MPa 1,0 1,0 MPa 1,6 1,6 MPa 2,5 2,5 MPa 4,0 4,0 MPa 6,4 6,4 MPa 10 10 MPa 15 15 MPa 25 25MPa 32 32 MPa 10 Process temperature - Standard, according to Table 5 11 Accuracy 0,5 Standard, according to Table 2 12 Digital display - Digital display with basic options 13 Power supply 24 24 V DC 220* 220 V AC *only for versions without explosion proof. 14 Output signal - Pulse output signal + analog signal 4 20 ma M H Optional digital interface ModBus-RTU Optional digital interface HART 15 Calibration, verification - Factory calibration, pressure test (for technological needs) GP Verification (for fiscal metering) THE EAMPLE OF THE ORDER: EMIS-MAG 270-Ex-080-PP-TI-6,4-24-M-GP(EMIS-MASS 260.CK) EMIS-MAG 270 flowmeter with explosion proof 0ExiallC(T3-T4) for primary transducer and 1Exd[ia]llCT4 for electronic transmitter, DN 80mm,standard flow range, primary transducer body material cast steel, lining material polypropylene, electrode material titanium, flange pipeline connection type, integral type transmitter, process fluid pressure 6,4 MPa, standard process fluid temperature limits, standard measurement accuracy, digital display with basic options, power supply 24V DC, with pulse and current 4-20 ma output signals and digital interface ModBus-RTU, verified. page 26 http://www.emis-kip.ru/prod/em270

EMIS-POTOK 236 FLOW SWITCH FOR LIQUIDS EMIS-POTOK EMIS-POTOK 236 PADDLE TYPE FLOW SWITCH EMIS-POTOK 285 THERMAL DISPERSION FLOW SWITCH APPLICATION Flow switches are used to protect pumps, engines and other devices from overheating, caused by low flow or it absence. It is usually used in automatic process control and management systems in power, chemical, petrochemical, food, paper and other industries. Flow switches are dedicated to be mounted on pipeline. Two versions: for general purpose and for explosion hazardous area. FEATURES & ADVANTAGES Durable and reliable in service Suitable for direct and reverse flow Resistant to high process fluid temperature Suitable for High North applications High process pressure limit SPECIFICATIONS Nominal pipe sizes...25-100mm Excess pressure... up to 5MPa Process fluid temperature... -30 C to +150 C* Explosion proof... 1ExdllB(T4-T6) Output signal... SPDT contact *Process fluid temperature for Vn version: -30 C +100 C. OPTIONAL SPECIFICATIONS Item Connection cables Description To connect flow switches to control and measuring instruments FEATURES & ADVANTAGES No moving part Body material aluminum alloy, flow sensor stainless steel SS304 Durable and reliable in service Suitable for direct and reverse flow Suitable for High North applications High process pressure limit SPECIFICATIONS Nominal pipe sizes... 25-300mm Process fluid pressure...up to 5MPa Process fluid temperature... -50 C to +65 C Flow velocity range: For water... 0,02-5m/s For crude oil... 0,03-3m/s For gas... 0, 3-5m/s Explosion proof...1exdllbt6 Output signal... SPDT contact http://www.emis-kip.ru/prod/ep_236 page 27

catalogue-2014 EMIS-POTOK 236 ORDERING INFORMATION FOR EMIS-POTOK 236 1 2 3 4 5 6 EMIS-POTOK 236 - Vn - - - 5 - Х - - - - 1 Explosion protection - Without explosion protection Vn Explosion proof 1ExdllB(T4-T6) 2 Nominal pipe sizes - Up to 100mm 3 Process fluid pressure 2,5 2,5MPa 5 5MPa 4 Process fluid temperature -* -30 C +150 C 5 Connection type - R1 GOST 6211-81 6 Output signal - SPDT contact The example of the order: EP 236-Vn-5- *- process fluid temperature for Vn version: -30 C +100 C. Flow switches for pipe sizes more than 100mm and other process fluid parameters are available by special order. Standard flow switches are dedicated for horizontal pipelines. ORDERING INFORMATION FOR EMIS-POTOK 285 1 2 3 4 5 EMIS-POTOK 285 - Vn - 5 - - - Х - - The example of the order: EP 285-Vn-5-1 Explosion protection - Without explosion protection Vn Explosion proof 1ExdllBT6 2 Nominal pipe sizes - Up to 300mm 3 Process fluid pressure 2,5 2,5MPa 5 5MPa 4 Process fluid temperature - -50 C +65 C 5 Connection type - K1/2 GOST 6111-52 6 Output signal - SPDT contact page 28 http://www.emis-kip.ru/prod/ep_236

EMIS DEEP-WELL RESEARCH COMPLE EMIS DEEP-WELL RESEARCH COMPLE APPLICATIONS EMIS deep-well research complex is based on vortex flowmeter EMIS- VIHR 200-SKV and ultrasonic flowmeter EMIS-ULTRA 292-SKV. It provides on-line parameters control and optimization of well operation process based on received data. EMIS deep-well research complex is dedicated for permanent liquid parameters control of certain developing wells equipped with independent parallel operation system. Controller (interface block) FEATURES & ADVANTAGES EMIS-VIHR 200-SKV and EMIS-Ultra 292-SKV flowmeter provides permanent control of well operating parameters Wide flow rang 1:40 and high measurement accuracy provides data communication to high level of Control System through radio link or GPRS; access to measurement data store is available anytime and anywhere Vortex principle and digital signal processing provide high accuracy 1,5%, warranted with certificate of conformity for measure instruments Up to 3 flowmeters can be set on one logging cable Smart signal processing, background noises reduction Metrological characteristics accuracy control Production tubing Special structure sucker rod pump Cable protectors with cable coupling boxes Producing formation Cable output Armored communication cable EMIS DEEP-WELL RESEARCH COMPLE Packer (sleeve packer) Specifications Well type... oil producing well / water-injection well Dynamic range... up to 1:40 Flow range... 1to 30 m 3 /day / 4,7 to 190 m 3 /day / 12,5 to 500 m 3 /day Flow measurement accuracy...up to ±5% Water cut... 0 to 100% Pressure measurement accuracy... 0,16% Process fluid pressure... up to 50MPa Pressure change resolution...0,001mpa Process fluid temperature... -20 C to +105 C Temperature measurement accuracy... 0,5% Temperature change resolution... 0,0033 MEASURING PARAMETERS Day well rate Current flow rate Pressure Temperature Producing formation BASE CASE Item Bore-hole vortex flowmeter EMIS-VIHR 200-SKV or ultrasonic flowmeter EMIS- Ultra 292-SKV Temperature sensor Pressure sensor Onshore interface module Application Day well rate measurement and current flow rate measurement Tubing outside temperature measurement Outside and inside pressure measurement Changed parameters data processing, storage and display. Data communication to high level of Control System Delivery kit includes component kit for easy installation and reliable service of the whole complex: Cable outlet sealing device Cable protectors for installation and protection use Armored cable with corrosive protection jacket!attention! To prevent wrong choice of equipment, EMIS questionnaire for deep-well research complex should be attached to your order, please. http://www.emis-kip.ru/prod/gik page 29

catalogue-2014 EMIS-ESKO 2210 ENERGY CARRIER METERING SKID EMIS-ESKO 2210 APPLICATIONS EMIS-ESKO 2210 metering skid is dedicated to measure flow, pressure, temperature, mass and the amount of media inside of the pipeline. It is used for commercial and technological metering of saturated and overheated steam, associated petroleum gas, natural gas, mixed gas, liquids and water solutions and also in water injection systems. FEATURES & ADVANTAGES Can be used in water injection systems Measures associated petroleum gas Serviceability High reliable construction Verification interval up to 4 years Stable metrological characteristics Flexibility ( suitable for different fluids) Remote data communications ( including wireless communication) OPTIONAL SPECIFICATIONS Application Item conditions Connection kit PipePipeline DN and Meter runs flowmeter DN are not match together Straight pipe length Flow straightener requirements can t be accomplished Installation closet For controllers, power KIP installation closet supply units and other devices To close metering skid Vandal-proof closet and functional inside of the closet. Communication devices Ethernet local area Controller K-104 network Controller GPRS/GSM Wireless communication Protocol interface unit USP 78 Bypass diode intrinsic safety barrier BIS-A-Ex (100 series) BIS-A-Ex (100 series) Intrinsic safety barrier with galvanic isolation BIS-A-Ex (300 series) RS-485 interface to connect external system Intrinsic safety barriers For Exd hazardous area application For Exia hazardous area application UI-200 Code EMIS-VEKTA 1200 InWBV 40.30.20 Pipe closet K-104 K-105 USP 78 BIS-A-108-Ex BIS-A-111-Ex BIS-A-301-Ex SpecificationS Nominal diameter...15 to 2000 mm Process fluids...steam/gas/liquid Process fluid temperature... -40 C to +460 C Process fluid pressure... up to 25MPa Accuracy ( for gas under normal conditions... 1,5% Accuracy (for steam under normal conditions... 3,0% Communication interface... RS-232/485; GSM/GPRS; Ethernet Power supply...(220 +22-33) V AC electricity network with frequency (50±1)Hz Ambient temperature for transmitters...40 C to +70 C Verification interval... 4 years MEASURING PARAMETERS Volume flow, mass flow, quantity of heat energy, process fluid temperature, process fluid pressure. BASE CASE Item Code Measuring devices* Vortex transmitter EMIS-VIHR 200 (205) Pressure transducer AIR-10Н (AIR-10L, AIR-10S, AIR-20) Resistance temperature sensor TPT-1-3 Computing device Metering controller TEKON 19-05M Power supply unit Power supply unit EMIS-BRIZ 90-4-24-100- DIN Connection kit Flowmeter CK EV-200.CK Valve block BKN-1-08 Weldolet for pressure sensor mounting EMIS-VEKTA 1130 Pressure reducing valve EMIS-VEKTA 1120 Protection sleeve EMIS-VEKTA 1300 Weldolet for temperature sensor mounting EMIS-VEKTA * - metering skid can be equipped with other measuring devices with the same specifications. page 30 http://www.emis-kip.ru/prod/emis-esko

EMIS-ESKO 2210 ORDERING INFORMATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 EMIS-ESKO 2210 1 - Zh - 1,5-1.60-100 - 150 / 200 - Ех - St - MSh - - - GP - I - - - - - V 0 Product name EMIS-ESKO 2210 EMIS-ESKO 2210 metering skid 1 Metering point number 1 One point 2 Two points 3 Three points 4 Four points 2 Process fluid Zh G P Liquid Gas Steam (saturated/overheated) Other 3 Accuracy 1,5 1,5% 2,5 2,5% 3,5 3,5% 5,0 5,0% 4 Maximum process fluid pressure (absolute) 0,04 0,04 MPa 0,40 0,40 MPa 4,00 4,00 MPa 0,06 0,06 MPa 0,60 0,60 MPa 6,30 6,30 MPa 0,10 0,10 MPa 1,00 1,00 MPa 10,00 10 MPa 0,16 0,16 MPa 1,60 1,60 MPa Х 0,25 0,25 MPa 2,50 2,50 MPa 5 Process fluid temperature 100-40 to +100 С 460-40 to +460 С 250-40 to +250 С Х 320-40 to +320 С 6 Pipeline connection size 015 15 mm 080 80 mm 300 300 mm 025 25 mm 100 100 mm 350 350 mm 032 32 mm 125 125 mm 400 400 mm 040 40 mm 150 150 mm. 050 50 mm 200 200 mm 2000 2000 mm 065 65 mm 250 250 mm Х 7 Flowmeter DN 015 15 mm 080 80 mm 300 300 mm 025 25 mm 100 100 mm 350 350 mm (for EV 205) 032 32 mm 125 125 mm 400 400 mm (for EV 205) 040 40 mm 150 150 mm. ( for EV 205) 050 50 mm 200 200 mm 2000 2000 mm (for EV 205) 065 65 mm 250 250 mm Х http://www.emis-kip.ru/prod/emis-esko page 31

catalogue-2014 EMIS-ESKO 2210 8 Explosion protection - General purpose industrial version Exd Exib Explosion proof enclosure for transmitters Intrinsically safe circuit for transmitters 9 Pipeline material N St Stainless steel Cast steel 10 Closet MSh ShT Closet for controllers and power supply units Closet for metering skid and functional devices - Without closet 11 Communication interface - RS-232 (USB) / CAN-BUS GPRS / GSM RS-485 E GPRS / GSM RS-485 Ethernet 12 Testing, calibration - Factory calibration GP Verification 13 Required software - Software for local data acquisition (Teleport software) I S ISKRa software for remote data acquisition Data integration to high level of SCADA 14 Connecting cable for metering controller D5/5 Cable 5x0,5 mm 2, 5m (standard, marked) - Not required 15 Meter runs 10/5 10DN upstream, 5DN downstream (standard version) - Without meter runs 16 Meter runs welding joints control V Visual and measuring control 100% H Chemical control 100%, visual and measuring control 100% UZ1 Ultrasonic control 100% (according to VSN 012-88), visual and measuring control 100% page 32 http://www.emis-kip.ru/prod/emis-esko

EMIS-ESKO 2210 METERING SKID WITH SELF-CONTAINED POWER SUPPLY UNIT EMIS-ESKO 2210-AIP APPLICATIONS Metering skid with self-contained power supply unit is dedicated for remote control of process parameters, to measure flow, pressure, temperature, mass and quantity of fluid inside of the pipeline. It is used for commercial and technological metering of saturated and overheated steam, associated petroleum gas, mixed gas, liquids and water solutions in areas situated far from warranted power supply. Self-contained power supply unit includes thermoelectric generator or solar battery with accumulator box. FEATURES & ADVANTAGES Can be used without external electricity source Vandal-proof closet is available Easy mounting, reliable construction Verification interval 4 years High durability of self-contained power supply unit Suitable for High North and for hot weather applications Remote data communications SPECIFICATIONS Nominal diameter...50 to 300 mm Process fluids...steam/gas/liquid Process fluid temperature... -40 C to +460 C Process fluid pressure... up to 6,3 MPa Communication interface... RS-232; GSM/GPRS Ambient temperature: For transmitters... -40 C to +70 C For controllers... -10 C to +50 C Verification interval...1 to 4 years Self-contained power supply unit resource: TEG... 8 years Solar panel... 15 years!attention! To prevent wrong choice of equipment, EMIS questionnaire for EMIS-ESKO 2210 metering skid should be attached to your order, please. BASE CASE Item Quantity Note 1 EMIS-ESKO 2210 metering skid 1 piece Version according to the order 2 Self-contained power supply unit 1 piece Version according to the order 3 Closet 1 piece 4 Calibration procedure manual 1 copy 5 User manual 1 copy 6 Certificate 1 copy http://www.emis-kip.ru/prod/emis-esko page 33

catalogue-2014 EMIS-VEKTA 1200 FLOW CONDITIONERS / STRAIGHTENERS EMIS-VEKTA 1200 APPLICATION Dedicated to reduce straight pipe length requirements. It is usually used with vortex flowmeters, ultrasonic flowmeters, differential pressure flowmeters and other types of flowmeters. Suitable for liquids, gases and stem pipelines. According to Zanker type flow conditioner GOST P 8.586.1. FEATURES & ADVANTAGES Compact design High-effective for flow stabilisation Suitable for different types of flowmeters Easy installation Long-term service Standard flanges (facing type 3, GOST 12815-80) SPECIFICATIONS Process pressure... liquid /gas / steam Nominal diameter... 15 mm to 1200 mm Material... cast steel / stainless steel / other ORDERING INFORMATION The example of the order: 0 1 2 EMIS-VEKTA 1200 078 - N 1 Pipeline DN 015 DN = 15 mm 025 DN = 25 mm 032 DN = 32 mm 040 DN = 40 mm 050 DN = 50 mm 065 DN = 65 mm 080 DN = 080 mm 100 DN = 100 mm 125 DN = 125 mm 150 DN = 150 mm 200 DN = 200 mm 250 DN = 250 mm 300 DN = 300 mm 350 DN = 350 mm 400 DN = 400 mm 500 DN = 500 mm 600 DN = 600 mm 700 DN = 700 mm 800 DN = 800 mm 900 DN = 900 mm 1000 DN = 1000 mm 1200 DN = 1200 mm To make hole sizes of flow conditioner in strict accordance with GOST R 8.586.1, please specify actual inner diameter of pipeline in mm 2 Material St Cast steel N Stainless steel Optional specifications Item EMIS-VEKTA 1200.CK-DN-St-P Description Connection kit (cast steel flanges, gaskets, stud bolts or bolts, screw- nuts, washers) Connection kit (stainless steel flanges, gaskets, stud bolts or screw- bolts, screw- nuts, EMIS-VEKTA 1200.CK-DN-N-P washers) Here P - is maximum pressure in MPa (1,6; 2,5; 4,0; 6,3; 10; 16; 20), DN is Nominal diameter, is special order. page 34 http://www.emis-kip.ru/prod/ev1200

EMIS-VEKTA 1210 LIQUID FILTERS EMIS-VEKTA 1210 APPLICATION Used to filter out particles from fluid. Are mounted upstream of flowmeter or metering system to protect it from breakdown, to improve metrological characteristics and service life. Used in oil filling and transfer stations (crude oil, oil products and other liquids). SPECIFICATIONS Nominal Diameter... 15 mm to 600 mm Maximum process pressure... 6,4 MPa Retention rate... 38 to 8000 µm (standard: 1700, 830, 380 µm, depending on process fluid viscosity) Connection type...flange VERSIONS Item Note DN, mm - (standard version) B DELIVERY KIT Item Amount, pcs 1 Filter 1 2 User manual and certificate 1 3 Passport 1 4 Package 1 Note: * - for DN 50mm. Maximum process pressure, MPa «Y»-type 15 40 4-30 to +250 50 300 6,4 400 600 2,5-20 to +250-40 to +250 With round attachments cower With quick-opening clump cover FLOW RANGES FOR EMIS-VEKTA 1210 (m 3 /h) 50 300 6,4-20 to 150 Petrol, liquefied gas, diesel oil, crude oil, residual oil Process temperature, C Ambient temperature, C Material Material St N1, N2, Stn St N1, N2, Stn Bitumen -20 to +80-40 to +80 Liquid viscosity 2000 mpa s DN, mm 0,32 400 mpa s 400 2000 mpa s 015 0 4,5 0 2,6 0 2,4 025 0 11 0,5 8,8 0 6,6 040 0 28 0 19,8 0 13,2 050 0 44 0 26,4 0 19,8 080 0 110 0 66 0 55 100 0 165 0 100 0 77 150 0 280 0 165 0 110 200 0 480 0 264 0 176 250 0 700 0 396 0 264 300 0 1100 0 660 0 495 400 0 1760 0 1210 0 825 OPTIONAL SPECIFICATIONS Item EMIS-VEKTA 1210.CK EMIS-VEKTA 1210.VT EMIS-VEKTA 1210.SFE Description Connection kit (flange, gaskets, screw-bolts, screw- nuts, washers) Insert pipes for installation use Filter cartridge http://www.emis-kip.ru/prod/ev1210 page 35

catalogue-2014 EMIS-VEKTA 1210 ORDERING INFORMATION 1 2 3 4 5 6 7 8 9 10 EMIS-VEKTA 1210 - B - 200 - St - - - Т - 4.0 - - - 830 - - 2 Version - Standard version B Quick opening cover 3 Nominal Diameter 015 Dn = 15 mm 300 Dn = 300 mm 025 Dn = 25 mm 400 Dn = 400 mm 040 Dn = 40 mm 500 Dn = 500 mm 050 Dn = 50 mm 600 Dn = 600 mm 080 Dn = 80 mm Х 100 Dn = 100 mm 150 Dn = 150 mm 200 Dn = 200 mm 250 Dn = 250 mm 4 Housing materials St Cast steel Ст20 Stn* Low-alloy steel 17Г1С N1 Stainless steel 08Х18Н10 (SS304 analog) N2 Stainless steel 03Х17Н14М2 (SS316 analog) * Only for DN 50mm. 5 Filter cartridge materials - Stainless steel 08Х18Н10 (SS304 analog) 6 Thermal jacket - Without thermal jacket T Thermal jacket for filter housing 7 Process pressure 1,6 1,6 MPa 2,5 2,5 MPa 4,0 4,0 MPa 6,4 6,4 MPa 8 Process temperature - According to Table 1 9 Retention rate 1700 For liquids with viscosity from 400 mpa*s to 3000 mpa*s 830 For liquids with viscosity from 2 mpa*s to 400 mpa*s 380 For liquids with viscosity from 0,32 mpa*s to 2 mpa*s Requiring mesh size(µm) 10 Differential pressure gauge connection - No D Thread holes for differential pressure gauges (standard M20x1,5)!Attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. page 36 http://www.emis-kip.ru/prod/ev1210

EMIS-VEKTA 1215 VERSIONS GAS FILTERS EMIS-VEKTA 1215 APPLICATION Used to filter out particles from fluid. Are mounted upstream of pressure regulator, meters or other equipment to protect it from breakdown, to improve metrological characteristics and service life. Dedicated for natural gas and other non-corrosive gases filtration in gas supply systems according to GOST 5542-87. SPECIFICATIONS Nominal Diameter... 15 mm to 300 mm Maximum process pressure... 2,5 MPa Retention rate... 38 to 8000 µm (standard: 180, 150µm, depending on process fluid parameters) Connection type... flange Item Note DN, mm - Y -type (standard version) With round attachments cower 50 300 B With quick-opening clump cover 50 300 DELIVERY KIT Item Amount, pcs 1 Filter 1 2 User manual and certificate 1 3 Passport 1 4 Package 1 Note: * - for DN 50mm. Maximum process pressure, MPa OPTIONAL SPECIFICATIONS Item Description EMIS-VEKTA 1215.CK EMIS-VEKTA 1215.VT EMIS-VEKTA 1215.SFE Process temperature, C Material St, N1, N2, Stn Connection kit (flange, gaskets, screwbolts, screw- nuts, washers) Insert pipes for installation use Filter cartridge 2 Version - Standard version B Quick opening cover 3 Nominal Diameter 015 Dn = 15 mm 150 Dn = 150 mm 025 Dn = 25 mm 200 Dn = 200 mm 040 Dn = 40 mm 250 Dn = 250 mm 050 Dn = 50 mm 300 Dn = 300 mm 080 Dn = 80 mm Х 100 Dn = 100 mm 4 Housing materials St Cast steel Ст20 Stn* Low-alloy steel 17Г1С N1 Stainless steel 08Х18Н10 (SS304 analog) N2 Stainless steel 03Х17Н14М2 (SS316 analog) * Only for DN 50mm. 5 Filter cartridge materials - Stainless steel 08Х18Н10 (SS304 analog) 6 Thermal jacket - Without thermal jacket T Thermal jacket for filter housing 7 Process pressure 1,6 1,6 MPa http://www.emis-kip.ru/prod/ev1210 2,5 2,5 MPa 8 Process temperature - According to Table 1 9 Retention rate 180 For liquids with viscosity 180 mpa*s 150 For liquids with viscosity 150 mpa*s Requiring mesh size(µm) 10 Differential pressure gauge connection - No D Thread holes for differential pressure gauges (standard M20x1,5) Ambient temperature, C Material St, N1, N2, Stn 2,5-20 to +80-20 to +70 ORDERING INFORMATION 1 2 3 4 5 6 7 8 9 10 EMIS-VEKTA 1215 - - - 15 - N1 - - - - - 1.6 - - - 180 - -!Attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. http://www.emis-kip.ru/prod/ev1210 page 37

catalogue-2014 EMIS-VEKTA 1212 FILTER-SEPARATOR EMIS-VEKTA 1212 APPLICATION Used to filter out steam, gas and particles from liquid. Are mounted upstream of flowmeter or metering system to protect it from breakdown, to improve metrological characteristics and service life. Used in oil filling and transfer stations (crude oil, oil products and other liquids). SPECIFICATIONS Nominal diameter... 40 mm to 800 mm Maximum process pressure... 6,4 MPa Retention rate... 38 to 8000 µm (standard: 1700, 830, 380 µm, depending on process fluid viscosity) Connection type... flange VERSIONS Item Note DN, mm - (standard version) B With round attachments cower With quick-opening clump cover Maximum process pressure, MPa 40 300 6,4 350 800 2,5 Process temperature, C Ambient temperature, C Material Material St N1, Stn St N1, Stn -20 to +250-40 to +250 40 300 6,4-20 to +150-20 to +80-40 to +80 FLOW RANGES FOR EMIS-VEKTA 1212 (m 3 /h) WITH DIFFERENT LIQUID VISCOSITY DELIVERY KIT DN, mm Petrol, liquefied gas, diesel oil, crude oil, residual oil Bitumen 0,32 400 mpa s 400 2000 mpa s Liquid viscosity 2000 mpa s 040 0 28 0 19,8 0 13,2 050 0 44 0 26,4 0 19,8 080 0 110 0 66 0 55 100 0 165 0 100 0 77 150 0 280 0 165 0 110 200 0 480 0 264 0 176 250 0 700 0 396 0 264 300 0 1100 0 660 0 495 400 0 1760 0 1210 0 825 300 0 1100 0 660 0 495 400 0 1760 0 1210 0 825 Item Amount, pcs 1 Filter 1 2 User manual and certificate 1 3 Passport 1 4 Package 1 OPTIONAL SPECIFICATIONS Item EMIS-VEKTA 1212.CK EMIS-VEKTA 1212.VT EMIS-VEKTA 1212.SFE Description Connection kit (flange, gaskets, screw-bolts, screw- nuts, washers) Insert pipes for installation use Filter cartridge page 38 http://www.emis-kip.ru/prod/ev1210

EMIS-VEKTA 1212 ORDERING INFORMATION 1 2 3 4 5 6 7 8 9 10 EMIS-VEKTA 1212 - - - 800 - St - - - - - 2.5 - - - 830 - - 2 Version - Standard version B Quick opening cover 3 Nominal Diameter 040 Dn = 40 mm 300 Dn = 300 mm 050 Dn = 50 mm 350 Dn = 350 mm 080 Dn = 80 mm 400 Dn = 400 mm 100 Dn = 100 mm 500 Dn = 500 mm 150 Dn = 150 mm 600 Dn = 600 mm 200 Dn = 200 mm 700 Dn = 700 mm 250 Dn = 250 mm 800 Dn = 800 mm Х 4 Housing materials St Cast steel Ст20 Stn* Low-alloy steel 17Г1С N1 Stainless steel 08Х18Н10 (SS304 analog) N2 Stainless steel 03Х17Н14М2 (SS316 analog) * Only for DN 50mm. 5 Filter cartridge materials - Stainless steel 08Х18Н10 (SS304 analog) 6 Thermal jacket - Without thermal jacket T Thermal jacket for filter housing 7 Process pressure 1,6 1,6 MPa 2,5 2,5 MPa 4,0 4,0 MPa 6,4 6,4 MPa 8 Process temperature - According to Table 1 9 Retention rate 1700 For liquids with viscosity from 400 mpa*s to 3000 mpa*s 830 For liquids with viscosity from 2 mpa*s to 400 mpa*s 380 For liquids with viscosity from 0,32 mpa*s to 2 mpa*s Requiring mesh size (µm) 10 Differential pressure gauge connection - No D Thread holes for differential pressure gauges (standard M20x1,5)!Attention! To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please. http://www.emis-kip.ru/prod/ev1210 page 39

catalogue-2014 EMIS-VEKTA VT INSERT PIPES EMIS-VEKTA VT APPLICATION Dedicated to be mounted on pipeline instead of relevant flowmeter. It is used during flowmeter repairs, verification or during welding counter flanges to the pipeline. ORDERING INFORMATION 0 1 2 3 4 5 6 INSERT PIPES EMIS-VEKTA VT VT200-080 - St - S - 1,6 - V 1 Flowmeter type VT200 EMIS-VIHR 200 VT215 EMIS-META 215 VT220 EMIS-PLAST 220 VT220R EMIS-PLAST 220R VT230 EMIS-DIO 230 VT240 EMIS-VENTURY 240 VT260 EMIS-MASS 260 VT270 EMIS-MAG 270 2 Nominal Diameter 008 DN=08 mm DN= mm 400 DN=400 mm 3 Material St Cast steel N Stainless steel 09G2S Steel 09G2S 4 Pipeline connection S Sandwich F Flange 5 Process pressure 1,6 Up to 1,6 MPa 6,3 Up to 6,3 MPa 25,0 Up to 25,0 MPa 2,5 Up to 2,5 MPa 10,0 Up to 10,0 MPa 42,0 Up to 42,0 MPa 4,0 Up to 4,0 MPa 16,0 Up to 16,0 MPa 6 Welding joins control V Visual and measuring control 100% H Chemical control 100%, visual and measuring control 100% UZ Ultrasonic control (according to ВСН 012-88), visual and measuring control 100% page 40 http://www.emis-kip.ru/prod/vt

DKS, DBS, DFK ORIFICE PLATES FOR FLOWMETERS DKS, DBS, DFK APPLICATION Orifice plates for differential pressure transmitters are used for differential pressure measurement of liquids, steam and gases. FEATURES AND BENEFITS Low cost No moving parts DN from 20mm to 400mm, depending on orifice plate type and version Process pressure up to 10 MPa High reliability Wireless verification in any regional center for standardization and metrology DKS orifice plates DKS chamber type orifice plate is a flat disk with a hole in the center, two chambers (positive and negative) with pipe nipples and sealing gasket. Standard orifice plates have one pair pipe nipples for pressure reducing, but it number can be increased up to 4 pairs on request. Standard orifice plate are available for pipeline DN=50 to DN=400mm (GOST 8.563.1, MI2638), with conical entrance, wear resistant (RD 50-411). Flange kit KF Flanges are used to install orifice plates on pipeline. Flanges are produced according to GOST 12820. Flange kit includes flanges, bolts, screw-nuts, washers and sealing gaskets. Flanged joint FS DKS orifice plates used with flanged joint provide lower measurement error. Flanges are produced according to GOST 12820, pipe nipples - according to GOST 8.563.1. Flanged joint includes flanges with nipples, bolts, screw-nuts, washers and sealing gaskets. Optional insert ring for installation and testing use is available on request. DBS orifice plates DBS chamberless orifice plate is flat disk with a hole in the center. Standard orifice plate are available for pipeline DN=300 to DN=400mm (GOST 8.563.1, MI2638), wear resistant (RD 50-411). DFK orifice plates DFK is flanged chamber type orifice plate are available for pipeline DN=20 to DN=40mm and nominal pressure up to 10 MPa. Chamber and flange are represented as a one component part. Orifice plate disk are produced according to RD 50-411, chamber disk according to GOST 8.563.1. Except standard DFK orifice plate, conical entrance type and wear resistant type are also available. DELIVERY KIT Item Amount, pcs 1 Orifice plate 1 2 3 Certificate (State verified passport) Orifice plate calculation signed and stamped by State Verification Officer 1 1!Attention! To make an order to produce an orifice plate, please send us following documents: EMIS questionnaire EMIS-DELTA «Base data for orifice plate calculation», available and requiring equipment list, straight pipe runs scheme. http://www.emis-kip.ru/prod/ed250 page 41

catalogue-2014 VESSELS SU, SR, SK LEVELING VESSELS, SEPARATION VESSELS AND CONDENSING VESSELS LEVELING VESSELS SU APPLICATION Leveling vessels are dedicated to maintain stable level of liquid in one of two connection lines during measuring level of liquid in tank using differential pressure sensors. SEPARATION VESSELS SR APPLICATION Separation vessels are used to protect inner parts of sensors from direct attack of corrosive fluids. It provide pressure impart through separation liquid. SPECIFICATIONS Materials...Alloy 20 stainless steel ( Steel 20) / 1218H10T Maximum pressure for SU... 6,3 / 25 / 40 MPa Maximum pressure for SR... 6,3 / 25 / 40 MPa Maximum pressure for SK... 4 / 10 / 40 MPa CONDENSING VESSELS SK APPLICATION Condensing vessels are used in steam flow measurements. It provide equal level of condensed steam in connection lines, which impart differential pressure from orifice plate to sensor. ORDERING INFORMATION The example of the order: 1 2 3 4 Levelling vessel SU - 6,3-2 - А 1 Vessel type SU SR SK Levelling vessel Separation vessel Condensing vessel 2 Process pressure 4 Pmax=4,0 MPa 6,3 Pmax=6,3 MPa 10 Pmax=10 MPa 25 Pmax=25 MPa 40 Pmax=40 MPa 3 Version 1 Version 1 (standard for SK) 2 Version 2 (standard for SR, SU) 4 Version 4 4 Material St Cast steel (steel 20) N Stainless steel (12Х18Н10Т GOST 5632) DELIVERY KIT Item Amount, pcs 1 Vessel according to the order 1 2 Certificate 1 3 Package 1 page 42 http://www.emis-kip.ru/prod/ev1120

EMIS-VEKTA 1100 VALVE BLOCKS FOR PRESSURE SENSORS EMIS-VEKTA 1100 EMIS-VEKTA 1100-1 APPLICATION Single-valve blocks are dedicated to be connected to control lines of gauge pressure sensors, absolute pressure sensors, vacuum-gauge pressure sensors or expansion pressure sensors. It provide sensor removal without process shutdown. EMIS-VEKTA 1100-2 APPLICATION 2-valve blocks except features of single-valve blocks provide extra features: pulse line drainage or connection to control gauge, pressure calibrator or other equipment. EMIS-VEKTA 1100-3 APPLICATION 3-valve blocks are dedicated to cut the pressure sensor off process fluid and for pressure leveling over sensor membrane during zero point adjustment. Special versions of 3-valve block also provide: 1. Measurement line drainage to protect sensor chambers from pollution. (pollution-proof) 2. Double pollution-protection during drainage. 3. Line drainage and control or backup sensor connection. EMIS-VEKTA 1100-5 APPLICATION 5-valve blocks provide 3-valve blocks features (pressure sensor cut off, pressure leveling during zero point adjustment, drainage) and additional control or backup sensor connection without main sensor shut off. SPECIFICATIONS Process fluid... Liquid, steam, gas, oxygen Process pressure... 40 MPa Process fluid temperature...-60 C to +150 C Material... 12Х18Н10Т Seals material... fluorine Warranty service... 36 months DELIVERY KIT Item Amount, pcs 1 EMIS-VEKTA 1100 valve assembly according to the order 1 2 Certificate 1 3 Package 1 http://www.emis-kip.ru/prod/ev1100 page 43

catalogue-2014 EMIS-VEKTA PRESSURE REDUCING VALVE EMIS-VEKTA 1120 APPLICATION Dedicated for manometers and pressure sensors mounting to pipelines or vessels. Are used to protect sensors from high temperature stress (overheating) and hydraulic impacts. SPECIFICATIONS Maximum process pressure... up to 25 MPa Maximum process temperature...up to 200 C Connection type... М20х1.5, G1/2, welded Base...Steel weldless pipe Nominal diameter... 14 mm Wall thickness... 2 mm WELDOLET EMIS-VEKTA 1130/1330 APPLICATION Weldolet is a part of pipeline dedicated for connection to thermometers, manometers, leveling or quality gauges, shut-off valves, pulse lines with process pressure up to 40 MPa. Weldolets are weld into pipe to be later connected to: 1130 valve blocks and valve systems, pressure reducing valves and different types of pressure sensors 1330 protection sleeves and different types of temperature sensors Indication Sizes Version Welding point M D D1 d L l1 l2 R M20x1,5 23,5 7 1130-29 7 40 16 K1/2 16 10 M20x1,5 29 23,5 18 40 20 7 - - M33x2 45 40 31 50 40 5 1330 K1/2 29 23,5 18,6 40 20 7 BR M33x2 45 40 31 55 40 10 29 PROTECTION SLEEVE EMIS-VEKTA 1300 APPLICATION Protection sleeves are dedicated to mount temperature sensors on pipelines, pressure vessels, steam boilers. They are used to protect sensors from process fluid impact and to provide sensors handling without process shutdown. Protection sleeves have two types specified by it structure features and nominal process pressure: Turned solid cylinder type protection sleeve; Conical protection sleeve. According to it mounting methods protection sleeves are divided into: Threaded; Welded. page 44 http://www.emis-kip.ru/prod/ev1100

EMIS-BRIZ 60 APPLICATION Pulse power supply units EMIS-BRIZ 60 are primary used in fiscal metering systems, automatic process control systems in district heating substations, heat supply stations, power stations, gasdistributing stations and public utilities providing 24 hour service. FEATURES AND BENEFITS Small sizes and mass Fault and short circuit alarming LED indication for each channel High-drain device supply Galvanic isolation of outputs PULSE POWER SUPPLY UNIT EMIS-BRIZ 60 DIN-rail mounted unit. SPECIFICATIONS Type...pulse Number of channels...1 Power supply... 90 to 246 VAC / 110 to 370 VDC Output voltage... 24V Mount... DIN-rail Ambient temperature... -20 to +50 C Water and dust ignition proof... IP20 ORDERING INFORMATION The example of the order: 1 2 3 4 5 6 EMIS-BRIZ 60-1 - 24-0,75-0,03 - S 1 изделия EMIS-BRIZ 60 Pulse power supply unit 2 Number of output channels 1 1 channel 3 Power supply 24 24V 4 Maximum output current 0,75 0,75A 5 Current limiting - Current limiting is not required 6 Fault alarming St Fault and short circuit alarming http://www.emis-kip.ru/prod/eb60_90 page 45

catalogue-2014 EMIS-BRIZ 90 TRANSFORMER POWER SUPPLY UNIT EMIS-BRIZ 90 APPLICATION Transformer power supply units EMIS-BRIZ 90 are primary used in different industries to supply non-explosion proof on-field sensors for general purposes in automatic process control systems, fiscal metering systems, different rigs and stands. FEATURES AND BENEFITS Channels are overcurrent-proofed and short-circuit-proofed Small size Power supply units don t create industrial noises Galvanic isolation of outputs LED indication for each channel High reliability DIN-rail mounted unit. ORDERING INFORMATION The example of the order: 1 2 3 4 5 EMIS-BRIZ 90-2 - 24-100 - DIN SPECIFICATIONS Type... tarnsformer Number of channels...2/4 Power supply...49 to 51Hz AC / 187 to 242 VDC Output voltage... 24V (±2%) Mount...DIN-rail Ambient temperature... -10 to +50 C Water and dust ignition proof... IP20 1 Наименование изделия EMIS-BRIZ 90 Transformer power supply unit 2 Number of output channels 2 2 channels 4 4 channels 3 Power supply 24 24V 4 Maximum output current 100 100 ma (50, 80, 120 ma) 5 Mount - DIN According to special order DIN NS35/7.5 is available. page 46 http://www.emis-kip.ru/prod/eb60_90

EMIS-SYSTEMA 750 RS-485 INTERFACE CONVERTER EMIS-SYSTEMA 750 APPLICATION EMIS-SYSTEMA 750 is dedicated for data communication between two gadgets, one of which uses RS-485, another one uses RS-232 or USB. FEATURES & ADVANTAGES Automatically calculate data transfer rate, format and direction Light indication of data transfer Galvanic isolation of input and output channels In-built reverse polarity protection and power and surge protection Gadgets with different data transfer rate and different formats can be connected to the same bus SPECIFICATIONS Type of network... half-duplex, two wire/two way Interface 1...RS-485 Interface 2... USB Transmission distance... 1,2 km Transfer rate... 115200 Kbps Power supply...through USB Channel isolation...1000 V Ambient temperature...-20 to +70 C Water and dust ignition proof... IP20 ORDERING INFORMATION Item EMIS-SYSTEMA 750-RS485-USB Description Конвертер физического уровня RS-485 и уровень USB. Питание от шины USB DELIVERY KIT Item Amount, pcs 1 Converter (according to the order) 1 2 Certificate 1 3 Drivers for USB on CD 1 4 USB cable or COM cable (according to the order) 1 INTRINSIC SAFETY BARRIERS BIS-A-111-E APPLICATION Provides intrinsic safe power supply according to Requirements for intrinsic safe circuit ib, pursuant to GOST R 51330.10 comply the requirements for IIB equipment. Matches with EMIS-VIHR 200 ExB version and other instruments with intrinsic safe circuit over 20 ma and 24 V. SPECIFICATIONS Open-circuit voltage...25,2 V Short circuit current...430ma Capacity C0... 0,93 μf (microfarad) Inductance L0...0,87 mh Ambient temperature...-10 to +50 C http://www.emis-kip.ru/prod/es750 page 47

catalogue-2014 SERVICES SELECTION, ENGINEERING, SUPERVISING INSTALLATION, INSTALLATION OF EMIS INSTRUMENTS EMIS Group has been providing engineering, installation, repair and maintenance services of metering skids for several years. All services are licensed and certificated. Engineering Our specialists prepare all the documents and provide approval of metering skids for natural gas and heat carriers, develop complex projects according to customer requirements and the operating conditions. Supervising installation Highly qualified specialist with long experience in installation of EMIS equipment will help you to choose an ideal point for installation, will consult on connection, setting up and operation of the whole skid. Supervising installation service will reduce considerably the time of process shut-down and will secure from wrong operation. SCADA Our specialists can create a data acquisition system based on Russian-made or foreign controllers with different SCADAsystems.!Attention! Warranty period will be doubled if order supervising installation service! Engineering and installation service Phone+7 (351) 729-99-12 (multichannel) Cellphone: +7 (919) 303-00-12 support@emis-kip.ru page 48 Flow measurement and automatization

SERVICES VERIFICATION OF LIQUID FLOWMETERS DESCRIPTION Automatic calibration rig for liquids provide calibration and verification of flowmeters with counter, electronic transmitter, frequency, pulse or analog output signals, using volumetric or mass measuring principle. SPECIFICATIONS Flow range...0,01 100 m 3 /h Process liquid... water according to GOST R51232-98 Process pressure...up to 0,4 MPa Flowmeter DN... 15 to 100 mm Verification methods...standard meter / mass Number of standard meters...3 Number of testing meters...up to 8 Metrological characteristics...see the table Metrological characteristics of verification facility Accuracy Pulse metering channel Analog metering channel Accuracy for volume (mass) flow measurements (mass method) ±0,05% ±0,07% Accuracy for volume (mass) flow measurements (standard meter verification method) ±0,25% ±0,26% Accuracy for temperature measurements ±0,05 о С Accuracy of automatic setup ±5% Root-mean-square deviation Not more than ±0,2% ORDERING PROCEDURE To order verification service, please provide following information: 1. Flowmeter type (vortex, magnetic (electromagnetic), chamber type etc.) 2. The name of flowmeter manufacturing company 3. Model of flowmeter 4. DN 5. Flow range 6. Accuracy class 7. Output signals 8. Verification procedure!issuing documents Verification is proceeding in presence of Chelyabinsk Center for Standardization, Metrology and Certification official representative. Metrology department +7 (351) 729-99-12 (multichannel) +7 (351) 729-99-13 (fax) +7 (912) 899-07-70 support@emis-kip.ru Flow measurement and automatization page 49